How German Energiewende s Renewables Integration Points the Way

Similar documents
The European Power System in 2030: Flexibility needs & integration benefits

The Flexibility Challenge in Global Power Sector Transformation: Monopoly vs. Liberalized Markets

WATER AND WIND QUÉBEC S CLEAN, RENEWABLE ENERGY RESOURCES

How to achieve Security of Energy Supply: The need for flexibility

Transformation of energy systems for high shares of vre

Insights from Germany s Energy Transition (Energiewende)

VIA ELECTRONIC FILING. August 29, 2014

LONG-TERM SOLUTIONS FOR NEW YORK S CLEAN ENERGY FUTURE

California Grid Operations: Current Conditions and Future Needs

The European Power System in 2030: Flexibility Challenges and Integration Benefits An analysis with a regional focus on the Pentalateral Energy Forum*

Terms of Reference AG 2017/01

Insights from Germany s Energiewende

Integrating variable renewables: Implications for energy resilience

Electricity Supply. Monthly Energy Grid Output by Fuel Type (MWh)

California ISO Preparing California for a Greener and Smarter Grid

Energiewende in Germany

RISK OF A CAPACITY SHORTAGE IN THE POLISH ELECTRICITY SYSTEM UP TO 2020

ASEAN s Energy Future: Challenges and Opportunities in the New Energy World

2016 Fall Reliability Conference MRO

PGE s 2013 Integrated Resource Plan

PJM Interconnection, L.L.C. ( PJM ) submits hereby submits its responses to the United

Electrification and its Implications for the California Electricity System

Portland General Electric 2016 Integrated Resource Plan. OPUC Public Meeting December 20, 2016

Energiewende: Going Green in Germany without going Red

Executive summary OECD/IEA Executive Summary

An Economic Assessment of the Benefits of Storage in South Africa. by Jeremy Hargreaves, Energy & Environmental Economics

The recent revision of Renewable Energy Act in Germany

Flexibility in Indian Power System

EPRI JOURNAL January/February 2018 No The Need for Large-Scale Energy Storage Grows, but the Business Case Remains Uncertain

The Transformation of the New England Electric Grid and the Importance of Situational Awareness Tools

Flexible energy for efficient and cost effective integration of renewables in power systems

Nuclear-renewable hybrid energy systems for non-electric applications

The Husker Power Plan: A New Energy Plan for Nebraska

Reduced Network Modeling of WECC as a Market Design Prototype

A New Market Design for the German Electricity Market Local and European Context

An Examination of National Grid s Future Energy Scenarios

Energy Storage Solutions Alstom Approach

Demand Response. US experiences, German challenges and market barriers

Smart energy systems and the role of Power-to-Gas

Integrating Variable Renewable Energy into the Grid: Sources of Flexibility Best Practices and Case Studies

Efficienza energetica, smart grid e fonti rinnovabili: la strada maestra per un Europa elettrica

THERMAL ENERGY STORAGE AS AN ENABLING TECHNOLOGY FOR RENEWABLE ENERGY

Principal Consultant Head of Infrastructure. Senior Consultant Quantitative Solutions

Gas-fired efficiency in part-load and pulse operation

Quantifying the capital requirement: 19% RE by 2030

Status and Challenges of the German Energiewende

The Commission's Energy Roadmap 2050

Consequences of the German Energy Transition on the operation regime and the availability of coal fired power plants

HIGH RESOLUTION RENEWABLE ENERGY SCENARIOS & KOMMOD MODEL APPLICATION

Report to the Texas Senate Committee on Business & Commerce

Innovation activities of renewable power generation technology providers in Germany

Power Perspectives 2030

Integrating Renewables in Power Systems: The clean energy corridors. IEC Affiliate Country Programme Forum Frankfurt, Germany 11 October 2016

Building the World's Largest Reciprocating Engine Power Plant in Jordan, 600MW

The Economic Impacts of the Energiewende (Energy Transition)

Ian Curry Managing Director BR Energy South Africa

2. 1 GOALS. Perceived goals of the Energiewende: environmental and climate protection + global competitiveness + political security of supply

Germany s energy system and the status of the energy transition

Zero Net Carbon Portfolio Analysis

Latest developments in Germany's -ongoing -Energiewende

Adapting to change. 17/08/2017 National Conference of State Legislatures Energy Policy Summit

THERMAL EFFICIENCY OF GAS FIRED GENERATION IN CALIFORNIA

Integrating Variable Renewable Electric Power Generators and the Natural Gas Infrastructure November 2011

Some Doubts about Oxford s Argument on Stranding Thermal Coal in Japan

Generation in Germany under Decarbonisation: The German Energiewende Bangkok, November 2013

The cost of renewable energy:

Southern California Edison Approach to Renewable Integration June 7, 2011

EMS of the Future. EMS Users Conference Chicago, Illinois. John McDaniel September 20, Proprietary 1 Experience you can trust.

Electricity Grid of the Future. Program Director: Dr. Sonja Glavaski

Integration of renewables and reliable power supply in Alaska

VIBRANT CLEAN ENERGY, LLC

Tucson Electric Power 2017 Integrated Resource Plan. Southern Arizona Regional Solar Partnership Jeff Yockey, PE

Europe s Coming Challenges in Meeting Decarbonisation Objectives

Politique et sécurité énergétique dans le contexte des nouvelles énergies

1. Executive Summary Ameren Missouri

PAGE 38 THOMAS KUSTERER THE GERMAN ENERGY TRANSITION

Energiewende braucht keine Speicher? Restricted Siemens AG All rights reserved

The transformation of distribution grids in the context of the European Energy Transformation

Energy Imbalance Market Overview

Promote new diplomacy on energy through leading global efforts against climate change

Las Vegas, NV Modeling of Clean Energy Policies and Electrification in New York and New England

THE CONTRIBUTION OF THE COAL FLEET TO AMERICA S ELECTRICITY GRID. Prepared for the American Coalition for Clean Coal Electricity August 2017

Integrating High Penetrations of Variable Renewable Generation Lori Bird and Debra Lew, NREL NCSL Webinar March 28, 2012

GLOBALE ENERGIEWENDE WUNSCHDENKEN ODER REALITÄT? Christine Lins Executive Secretary

EXECUTIVE SUMMARY. In accordance with New Mexico Administrative Code, Integrated Resource Plan for Electric Utilities.

2 November Project Manager Queensland Renewable Energy Expert Panel PO Box 15456, City East Queensland Online:

Power-to-Gas energy storage is key to Germany s energy transition

Zero Net Carbon Portfolio Analysis

Elia s view on Belgium s Energy Vision for Our contribution to the energy debate in Belgium

Competitiveness and System Value of Electricity Generation Technologies The Brazilian Case LUCIANO LOSEKANN DIOGO LISBONA EDMAR DE ALMEIDA

b u i l d i n g a sustainable energy future s t r at e g i c plan

Nuclear Power Plants Closures: A Crisis in America

1.818J/2.65J/3.564J/10.391J/11.371J/22.811J/ESD166J SUSTAINABLE ENERGY. Prof. Michael W. Golay Nuclear Engineering Dept.

The Role of the ISO/RTO in Today s. Robert B. Burke Principal Analyst ISO New England Inc.

Update on FERC, NERC, DOE & Congress John P. Hughes President & CEO Electricity Consumers Resource Council Washington DC

New power bridges between Germany and Scandinavia

Challenges and opportunities for Clean Coal Technologies in Europe and Germany

Ancillary Services Market Organization in Germany

Solar Integration into the PJM Grid

Gas-Electric Coordination in PJM: Trends, Issues, Interactions, and Looking Ahead

Transcription:

How German Energiewende s Renewables Integration Points the Way Reliability Increased BY MICHAEL HOGAN, CAMILLE KADOCH, CARL LINVILL AND MEGAN O REILLY 48 PUBLIC UTILITIES FORTNIGHTLY FEBRUARY 218

XT he power system in the United States, like that in numerous other countries throughout the world, is in a period of transition. Overall, generation is shifting away from large, inflexible thermal generation, that is, traditional baseload generation, and toward smaller, more dispersed, variable renewable resources. This transition is occurring both because citizens are calling for less carbon-intensive resources, and simply because wind and solar have become among the least expensive resources. U.S. natural gas prices have declined and the cost of renewables has come down dramatically. A recent report from the R Street Institute, Embracing Baseload Power Retirements, noted that Historically, conventional baseload resources were integral to achieving portfolio reliability at least cost, but some of these resources no longer provide the most economical means to meet reliability needs. This shift has triggered a debate among some U.S. policymakers about reliability and the continued need for baseload power plants such as coal and nuclear. Scott Pruitt, head of the Environmental Protection Agency, has said that coal-fired power plants are key to preserving electricity reliability. This thinking is likewise reflected in the U.S. Department of Energy s recent proposal to allow special cost recovery for generators that can store ninety days of fuel on site. However, numerous studies sponsored by utilities, system operators, the national labs, and others show that a large share of variable renewable energy production can be integrated while keeping the lights on, without any valuable role for traditional baseload. No study, not even by the Department of Energy, which examined this issue in an August 217 Staff Report on Electricity Markets and Reliability, has found evidence that baseload generation is required for reliability. Most studies have found that reliability and least cost are best served by reducing the share of inflexible baseload generation. To the extent that reliability is a concern, it is not one driven by a lack of available generating capacity. A recent report from Rhodium Group found that a mere.865 percent of all customer service hours lost from 212 to 216 were due to either fuel supply emergencies or other concerns about the availability of generation. American policymakers who are still skeptical can look across the Atlantic for a concrete example of a successful transition away from traditional baseload. Germany traditionally relied on a significant share of inflexible thermal generation such as coal and nuclear to supply the grid. Resources were dispatched to Michael Hogan is a senior advisor to the Regulatory Assistance Project (RAP), working on issues related to power market design, integration of low-carbon supply, system planning, and demand response in the United States and Europe. Camille Kadoch is RAP s general counsel and publications manager. Dr. Carl Linvill is a RAP principal, leading the organization s efforts on renewable energy integration and transmission planning in the Western United States. Megan O Reilly is an environmental lawyer and principal and owner of Arc Research and Analysis; she worked with RAP and Agora Energiewende as a Robert Bosch Fellow in 216-217. In spite of the fact that Germany is meeting nearly a fifth of its electricity requirements with VREs while retiring inflexible thermal generation, the nation has not experienced reliability problems. meet load, and variable resources were few. Now, Germany is a leader in the early adoption of variable renewable energy resources (VREs). The country has shown leadership by pursuing what it calls the Energiewende or energy transition, which has set a national goal of eighty percent decarbonization by 25. Government statistics show that VREs now make up eighteen percent of the German electricity mix, and all renewables, including hydro, account for twenty-nine percent. At the same time, Germany is phasing out baseload nuclear plants and is also working on decarbonizing its remaining energy mix by phasing out inflexible baseload coal-fired generation. In spite of the fact that Germany is meeting nearly a fifth of its electricity requirements with VREs while retiring inflexible thermal generation, the nation has not experienced reliability problems on either the distribution or bulk electric system. If anything, government data show that the reliability of the German system has increased. About the Energiewende The German Energiewende is one facet of the government s commitment to an aggressive, economy-wide reduction in greenhouse gas emissions. The Energiewende has set ambitious targets for renewable energy. FEBRUARY 218 PUBLIC UTILITIES FORTNIGHTLY 49

FIG. 1 KEY GERMAN ENERGIEWENDE TARGETS Status quo 22 225 23 235 24 25 Greenhouse gas emissions Nuclear phase-out Renewable energies Energy efficiency Reduction of CO 2 emissions in all sectors compared to 199 levels Gradual shutdown of all nuclear power plants by 222 Share in final energy consumption Share in gross electricity consumption Reduction of primary energy consumption compared to 28 levels Reduction of gross electricity consumption compared to 28 levels -26.4% 11 units shut down (215) 12.4% (213) 27.3% -9.1% -4.8% -4% -55% -7% Gradual shutdown of remaining eight reactors 18% 3% 45% 4 45% 55 6% -8 to -95% min. 6% min. 8% -2% -5% -1% -25% Renewables should make up at least fifty percent of the power generation mix by 23, sixty percent by 24, and eighty percent by 25. Germany has significantly diversified its electricity mix toward renewables, which grew from just four percent in 199 to the current twenty-nine percent. Germany s goal of eighty percent renewable energy by 25 now has to be met at the same time as the country retires its nuclear fleet. After the nuclear accident at Japan s Fukushima Daiichi plant in March 211, the German government set a nuclear phase-out deadline of 222. As part of this move, the seven oldest nuclear reactors were immediately shut down. To meet these goals, the country is anticipating a future with large amounts of variable renewables, no nuclear power, and very small amounts of fossil fuels. In this context, dispatching large thermal power plants in baseload service to meet demand is increasingly outmoded. Germany already produces hours of nearly a hundred percent renewable electricity on the system. As a spokeswoman for the Federal Ministry of Economics and Energy has put it, baseload is no longer needed, otherwise it could block the grid. This has consequences for the inflexible thermal generation that remains on the system. See Figure One. During hours of low VRE production, baseload plants that were displacing cheaper energy sources leading up to these hours have little or no capacity in reserve, requiring investment in additional, peaking generation capacity that sits idle most of the time. By contrast, more flexible, dispatchable generation that can As a spokeswoman for the Federal Ministry of Economics and Energy has put it, baseload is no longer needed, otherwise it could block the grid. ramp down during periods of high VRE production can maximize the use of cheap energy, while at the same time inherently providing the reserve capacity needed for other hours. Germany eventually envisions moving to an electricity market 2. where the focus shifts to balancing net load. Inflexible baseload generation will be used infrequently because it is not competitive with more flexible supply-side and demand-side resources in many hours. Wind and solar would provide the bulk of energy over a regional grid, with smart demand-side flexibility and more flexible load-following thermal generation helping to balance out the system. What Has This Meant in Practice? With the share of renewable production now close to a third of the total electricity mix, and with nuclear plants retiring, how is the reliability of the German electricity system faring? The chart below tracks the trends in the country s energy mix as well as System Average Interruption Duration Index (SAIDI), a measure of the annual average duration of interruption in customer service from all causes, indicated in minutes per year. 5 PUBLIC UTILITIES FORTNIGHTLY FEBRUARY 218

The chart also shows Loss of Load Expectation (LOLE) numbers, a widely used measure of resource adequacy that assesses how many minutes a year, on average, the available generation capacity in a given control area is likely to fall short of total demand. Both the SAIDI and LOLE numbers show that increasing amounts of VREs and decreasing baseload production have not negatively affected reliability in Germany to date. See Figure Two. Both the SAIDI and LOLE data indicate that reliability has followed historic trends. The potential uptick in LOLE numbers for 225 reflects the fact that LOLE nearly always shows an increase that far into the future, because LOLE only reflects committed generation investments and commitments to new resources that are normally made within a five year time frame. Even the projected uptick should be put into perspective: it projects an LOLE of less than twenty minutes per year, well below the prevailing U.S. standard of a hundred and forty four minutes per year. A more granular analysis of SAIDI numbers over the past decade indicates that the reliability of the medium- and low-voltage system has in fact improved over this period. The next chart tracks the duration of disruptions attributable to distribution system events between 26 and 215 showing a clear decline over that period. The Bundesnetzagentur Monitoring Report 216, from which this data is drawn, noted that the energy transition and the associated increase in embedded generation does not appear to have had a discernible impact on the quality of supply in 215. See Figure Three. System adequacy in Germany is based on a national power balance, but given that electricity is traded cross-border in the European interconnected system, the SAIDI and LOLE numbers in this FIG. 2 GERMANY: RESOURCE MIX VS. GRID RELIABILITY % of total energy production Voltage level (electricity) minutes Variable RES Baseload SAIDI LOLE 8 16 7 14 6 12 5 1 4 8 3 6 2 4 1 2 26 7 8 9 21 11 12 13 14 15 16 17 18 19 22 225 FIG. 3 SUPPLY DISRUPTIONS UNDER SECTION 52 ENWG BY VOLTAGE LEVEL 21.53 19.25 Mean 15.872 16.89 14.63 14.9 15.31 15.91 15.32 12.28 12.7 26 27 28 29 21 211 212 213 214 215 FIG. 4 CHALLENGING WEEK: WESTERN INTERCONNECTION WIND AND SOLAR 4, Net demand Wind CSP PV Total demand 35, 3, 25, MW 2, 15, 1, 5, 5, April 11 April 12 April 13 April 14 April 15 April 16 Minutes per year FEBRUARY 218 PUBLIC UTILITIES FORTNIGHTLY 51

context are being considered in a vacuum. Weighing the availability of resources across the wider European system would presumably increase reliability even further. What Does the Energiewende Teach Us About What Resources Are Needed? The Energiewende also demonstrates the types of resources that are needed on a system with large amounts of VREs. The figure below illustrates this. Prior to integration of VREs, system operators needed to meet fairly predictable total demand (top line in purple) with dispatchable generation sources, with a substantial amount of non-fluctuating demand. However, in a system where variable resources are integrated fully, dispatchable resources now need to follow changes in the residual net demand (blue line) not already served by free energy from variable renewables, and very little of the net demand is non-fluctuating. See Figure Four. Baseload resources, traditionally nuclear and coal plants, are not technically or economically well suited to this new paradigm. It will be more volatile and costly to balance the system if the dispatchable resource base continues to be dominated by inflexible baseload generation. To the extent there is a demand for generation to be operated round the clock, more flexible plants are fully capable of meeting this need. This is good news for consumers. Currently, grid operators dispatch wind and solar fi rst because they have the lowest operating costs. The weather-dependent nature of the resources creates a need for other resources to adjust their dispatch more frequently and extensively to balance system supply and demand. Continuing to rely on inflexible baseload would require curtailment of less costly energy. The alternative is an economic mix of VREs and load-following plants that displaces baseload operations. By removing inflexible baseload in favor of more flexible load-following plants, consumers realize the full benefit of the lowest-cost resources while receiving the same quality of service. Germany is now debating how increasing shares of VRE can be integrated cost-effectively. In the spring of 217, the country s national regulatory authority published a report that analyzed five events in 215 where a high share of VREs on the grid coincided with negative market prices. The report closes by recommending further ways to decrease costs of VRE integration while decreasing inflexible thermal generation. Recommendations included better forecasting (of load, and of renewable energy supply), support for infrastructure investments, better use of spinning reserves, and other system improvements. Resource Capabilities, Not Baseload Resources The experience of the Energiewende shows that increasing amounts of renewable energy on the power system, while at the same time reducing By removing inflexible baseload in favor of more flexible loadfollowing plants, consumers realize the full benefit of the lowest-cost resources while receiving the same quality of service. inflexible baseload generation, does not harm reliability and can lower the cost of VRE integration. Indeed, the German data suggest that reliability has actually improved under these conditions. What the Energiewende does demonstrate is a need for greater system flexibility. Germany s energy transformation envisions a grid where conventional thermal generation would follow net load, meeting shortterm energy demand in some hours and the demand for flexible reserves in other hours, and variable renewable energy such as wind and solar energy would provide the bulk of energy over a regional grid. The Energiewende provides evidence that this type of system can be reliable and is attainable. For regulators and policymakers in the U.S. deliberating whether and how to respond to federal officials and others who insist that inflexible baseload is essential for reliability, the German experience offers important evidence to the contrary. PUF 52 PUBLIC UTILITIES FORTNIGHTLY FEBRUARY 218