Proven Capabilities. Features and Benefits. Watlow provides:

Similar documents
THERMOCOUPLE AND EXTENSION GRADE BARE WIRE

Thermocouple Wire and Cable Insulation THERMOCOUPLE AND EXTENSION GRADE WIRE Type J

International Thermocouple and Extension Grade Wire Color Codes

7. EXTENSION LEADS AND COMPENSATING CABLE

Temperature Sensing Thermocouple and Extension Wire. Thermocouple Wire and Thermocouple Extension Wire

WATLOW S HEATING SOLUTIONS

Thermocouples and Accessories Product Catalog

WATLOW A Trusted and Reliable Partner

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

KANTHAL Alloys. For Thermocouple, Extension and Compensating Cables

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

Metal Transitions HIGH TEMPERATURE

MGO INSULATED THERMOCOUPLES INDEX

Platinum Resistance Thermometer (PRT) Selection Guide

INDUSTRIAL TEMPERATURE SENSORS

Temperature Sensors. The Watlow Educational Series Book Four

SECTION 2: PROBES. Page 2-1

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

Thermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry

Thermocouple Accuracies Tolerance classes for thermocouples to IEC : 1982.

Thermal-Tab and Thermal-Ribbon Sensors

4 RESISTANCE THERMOMETRY

Low drift Type K and N Mineral Insulated thermocouples for high temperature applications. Dr. Michele Scervini Trevor D Ford. CCPI Europe Limited

Realization of ITS-90 from K through K: One Company s Approach

Temperature Measurement and Control

Thermocouple cable and assemblies ENCLAD

SURFACE TEMPERATURE SENSORS

Electrical Conductors

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

FROM HIDDEN DEPTHS COMES UNEXPECTED POWER

General Information, Industrial Thermocouple Section

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

Industrial Thermocouples

Resistance Temperature Detectors (RTD)

Heritage Quality Performance

YSI Precision Thermistors & Probes

The Company by Peter Bröckskes sen. an independent, middle sized company

Reference thermometer Model CTP5000

Keysight Technologies Laser Heated Tip and High Temperature Stage for G200 Nano Indenter. Data Sheet

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

AUTHENTIC. DuPont Vespel Polyimide Shapes THE SUCCESS OF YOUR APPLICATION DEMANDS IT.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

THE NEXT GENERATION OF THERMOCOUPLES FOR THE TURBINE ENGINE INDUSTRY

WHITE PAPER Flex Life vs Flexibility

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

ITS.90THERMOSENSORS. Booklet

SANDELIUS INSTRUMENTS, INC.

Thermocouples for Ultra High Temperature Technologies

Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE

Thermocouple Reference Table

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

Gage Series Stress Analysis Gages

AM1880 Standard Platinum Resistance Thermometer User s Guide

Uni-Seals Product Catalog

Thermocouple for Flue Gas Temperature Measurements,

Industrial Thermocouples

nicrom e l e c t r o n i c

SECTION INSULATED WIRE AND CABLE

AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide

De-Mystifying Calibration Accreditation 15 Jan 2013

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

Energy Division Insulators

SECTION GROUNDING AND BONDING

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Flow Through Toroidal Conductivity Sensor

*** Supercedes: BECO E and COM , , & ***

3M Electrical, Electronic and EMI Shielding Tapes Selection Guide

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

Glossary Of Terms M-1

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

DOW PuraGuard Propylene Glycol USP/EP. Your Security for Purity

LNG VACUUM INSULATED PIPE SOLUTIONS.

A-44 J. Magnetic ERIEZ. Pull Test Kits. Digital Calibrated Kit includes NIST traceable digital scale

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Our Mineral Insulated Thermocouple Assemblies

Platinum Temperature Sensors

Plasma Heat and Surface Treatment

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max


ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Bonded Neo Magnetization Guide

W I R E S a n d C A B L E S

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide

Engineering Data for Copper and Aluminum Conductor Electrical Cables

VERIS Accelabar. Superior Flow Measurement Accuracy

Tapes. Reliable. Solar Industry. for the. 3M Tapes for Solar Panel Fabrication

KNIFE GATE & SLURRY VALVE PRODUCT GUIDE

Vogt Valves The Connection Bulletin for Post Weld Heat Treatment of Socket Weld Valves CB 20

Transcription:

Proven Capabilities Since 1914, SERV-RITE thermocouple wire and thermocouple extension wire from Watlow have been known for premimum performance and reliability. All SERV-RITE wire is manufactured under rigid quality control. It is manufactured under ISO 9001 quality standards. Some wire can even be shipped next day for your convenience. All testing has National Institute of Standards Technology (NIST), formally National Bureau of Standards (NBS), traceability. Unless otherwise specified, all SERV-RITE thermocouple wire and extension wire are supplied to meet standard tolerances of ASTM E 230. Special tolerances are also available. Watlow provides: Same day shipment on hundreds of stock items Temperature range capability from -328 to 2200 F (-200 to 1205 C) Superior products and technical support delivered worldwide State-of-the-art, in-house laboratory services including; calibration, end-to-end uniformity testing, drift testing, base metal, platinum and standard platinum resistance thermometer (SPRT) standards with traceability to NIST NIST certifications of conformance and calibration Multitude of overbraids, wraps and insulations available, including electrical noise shields and wraps Full range of resistance temperature detector (RTD) wire (not listed in this publication) ASTM E 230 tolerances from ±0.9 F (±0.5 C) or ±0.4 percent ISO 17025 accredited lab Features and Benefits Type E, J, K, N and T thermocouple wire Fits virtually all applications Type EX, JX, KX, NX, TX extension wire Matches thermocouple type Compensation extension wire for Type R and S thermocouples Permits fine tuning of temperature measuring circuit Solid or stranded wire construction Meets specific application requirements Wide selection of insulation types Meets temperature, chemical, moisture and abrasion resistance objectives Color coding Allows compliance with United States, United Kingdom, Germany, Japan and IEC standards Select metallic overbraids and wraps Provides enhanced abrasion resistance Stock RTD lead wire Meets virtually all industrial RTD applications

SERV-RITE Wire and Cable Nominal Resistance for Thermocouple Alloys in Ohms per Double Feet at 68 F (20 C) B and S Gauge Diameter in. (mm) E J K N RX, SX T 2 0.258 (6.5) 0.011 0.006 0.009 0.012 4 0.204 (5.2) 0.017 0.009 0.014 0.019 6 0.162 (4.1) 0.028 0.014 0.023 0.030 8 0.129 (3.3) 0.044 0.023 0.036 0.048 10 0.102 (2.6) 0.070 0.036 0.058 0.077 12 0.081 (2.1) 0.111 0.057 0.092 0.123 0.006 0.048 14 0.064 (1.6) 0.177 0.091 0.147 0.195 0.010 0.076 16 0.051 (1.3) 0.281 0.145 0.233 0.310 0.016 0.120 18 0.040 (1.0) 0.453 0.234 0.376 0.500 0.025 0.194 20 0.032 (0.8) 0.709 0.367 0.589 0.783 0.040 0.304 22 0.025 (0.7) 1.129 0.584 0.937 1.245 0.063 0.483 24 0.020 (0.5) 1.795 0.928 1.490 1.980 0.100 0.768 26 0.016 (0.4) 2.853 1.476 2.369 3.148 0.159 1.221 28 0.013 (0.3) 4.537 2.347 3.767 5.006 0.253 1.942 30 0.010 (0.3) 7.214 3.731 5.990 7.960 0.402 3.088 32 0.008 (0.2) 11.470 5.933 9.524 12.656 0.639 4.910 34 0.006 (0.2) 18.239 9.434 15.145 20.126 1.016 7.808 36 0.005 (0.1) 29.000 15.000 24.080 32.000 1.615 12.415 14 Stranded 0.076 (1.9) 0.161 0.083 0.134 0.178 0.009 0.069 16 Stranded 0.060 (1.5) 0.256 0.133 0.213 0.283 0.014 0.110 18 Stranded 0.048 (1.2) 0.408 0.211 0.338 0.450 0.023 0.174 20 Stranded 0.038 (1.0) 0.648 0.335 0.538 0.715 0.036 0.277 22 Stranded 0.030 (0.8) 1.031 0.533 0.856 1.137 0.057 0.441 24 Stranded 0.024 (0.6) 1.639 0.848 1.361 1.808 0.091 0.701 Conductor Size B and S Gauge Solid Diameter in. (mm) 14 0.064 (1.6) 0.076 (1.9) 7 22 16 0.051 (1.3) 0.060 (1.5) 7 24 18 0.040 (1.0) 0.048 (1.2) 7 26 20 0.032 (0.8) 0.038 (1.0) 7 28 22 0.025 (0.6) 0.030 (0.8) 7 30 24 0.020 (0.5) 0.024 (0.6) 7 32 26 0.016 (0.4) 28 0.013 (0.3) 30 0.010 (0.3) 32 0.008 (0.2) 34 0.006 (0.2) 36 0.005 (0.1) Stranded Diameter in. (mm) Number of Strands Stranding Gauge 1

p y Limits of Error ANSI Popular Generic Maximum Useful (whichever is greater) Code Conductor and Trade Names Temperature Ranges* Standard Special Thermocouple Calibration Typesp E EP EN Chromel Constantan -328 to 1652 F (-200 to 900 C) Above 32 F (0 C) ±3.0 F (1.7 C) or 0.5% Below 32 F (0 C) ±3.0 F (1.7 C) or 1.0% ±1.8 F (1.0 C) or 0.4% J JP JN Iron Constantan 32 to 1382 F (0 to 750 C) ±4.0 F (2.2 C) or 0.75% ±2.0 F (1.1 C) or 0.4% K KP KN Chromel Alumel -328 to 2282 F (-200 to 1250 C) Above 32 F (0 C) ±4.0 F (2.2 C) or 0.75% Below 32 F (0 C) ±4.0 F (2.2 C) or 2.0% ±2.0 F (1.1 C) or 0.4% N NP NN Nicrosil Nisil 32 to 2282 F (0 to 1250 C) Above 32 F (0 C) ±4.0 F (2.2 C) or 0.75% ±2.0 F (1.1 C) or 0.4% R** RP RN Copper #11 Alloy ±9.0 F (±5.0 C) ±1.1 F (0.6 C) or 0.1% S** SP SN Copper #11 Alloy ±9.0 F (±5.0 C) ±1.1 F (0.6 C) or 0.1% T TP TN Copper Constantan -328 to 662 F (-200 to 350 C) 32 to 212 F (0 to 100 C) Above 32 F (0 C) ±1.8 F (1.0 C) or 0.75% Below 32 F (0 C) ±1.8 F (1.0 C) or 1.5% ±1.1 F (0.6 C) or 0.4% * Note: Conductor gauge size may limit upper temperature ranges. Contact a Watlow representative for additional information. **Note: Compensating alloys used for extension wire applications. 2

International Color Codes BS DIN JIS IEC ANSI/ASTM ANSI/ASTM 1843 43710 C1610-1981 584-3 Common T/C Exten. (Britian) (Germany) (Japan) (Europe) Uses Suitable for use in oxidizing or inert atmosphere. Limited use in vacuum or reducing atmosphere. Suitable for sub zero. Reducing vacuum, inert. Limited use in oxidizing above 1004 F (540 C). Not recommended for sub zero. Suitable for use in oxidizing or inert atmosphere. Limited use in vacuum or reducing. Suitable for sub zero. Alternative to Type K. More stable at high temperatures. Suitable for use in oxidizing or inert atmosphere. Do not insert in metal tubes. Beware of contamination at high temperatures. Suitable for use in oxidizing or inert atmosphere. Do not insert in metal tubes. Beware of contamination at high temperatures. Mild oxidizing, reducing vacuum or inert. Good where moisture is present. Low temperature and cryogenic applications. 3

Braided Insulations Insulation Series Number Primary Insulations Secondary Temperature Range Continuous Single Reading F ( C) F ( C) Abrasion Moisture Chemical 301 Vitreous Silica Vitreous Silica 1800 (982) 2000 (1093) F F G 302 Double Glass Glass 900 (482) 1000 (538) G G G 303 Enamel Glass 900 (482) 1000 (538) F G G 304 Glass Glass 900 (482) 1000 (538) F G G 305 Double Glass Wrap Glass 900 (482) 1000 (538) F G G 306 Glass Glass (no impregnation) 900 (482) 1000 (538) F F G 307 TFE Glass 900 (482) 1000 (538) G E E 309 Glass Glass 1300 (704) 1600 (871) G F G 311 Glass Glass (low temp. impregnation) 1300 (704) 1600 (871) F F G 313 Heavy Glass Heavy Glass 900 (482) 1000 (538) G G G 314 Glass Twisted 1300 (704) 1600 (871) G G G 315 Glass Twisted 900 (482) 1000 (538) G G G 321 Glass Glass 1300 (704) 1600 (871) G G G 350 Ceramic Fiber Ceramic Fiber 2200 (1204) 2600 (1427) G F G 355 Ceramic Fiber Ceramic Fiber 2200 (1204) 2600 (1427) G F G 365 Vitreous Silica Vitreous Silica 1800 (982) 2000 (1093) F F G Tape and Extruded Insulations Insulation Construction Temperature Range Insulation Continuous Single Reading Series Number Single Shield Jacket F ( C) F ( C) Abrasion Moisture Chemical 502 PVC PVC 221 (105) 221 (105) G E G 505 PVC Ripcord 221 (105) 221 (105) G E G 506 FEP FEP (<26 AWG) 400 (204) 500 (260) E E E 507 FEP FEP 400 (204) 500 (260) E E E 508 TFE Tape TFE Tape 500 (260) 600 (316) G E E 509 FEP Shield FEP 400 (204) 500 (260) E E E 510 PVC Shield PVC 221 (105) 221 (105) G E G 511 Polyimide Tape Twisted 600 (316) 800 (427) E E E 512 Polyimide Tape Polyimide Tape 600 (316) 800 (427) E E E 514 Tefzel Tefzel 302 (150) 392 (200) E E E 515 Tefzel Shield Tefzel 302 (150) 392 (200) E E E 516 PFA PFA 500 (260) 550 (288) G E E 517 PFA Shield PFA 500 (260) 550 (288) G E E F = Fair, G = Good, E = Excellent 4

Ordering Information* Code Number 1 2 3 ANSI Calibration B and S Gauge 4 5 6 7 8 9 Metallic Overbraids (Optional) Insulation Series Conductor Type/ Tolerance 10 11 Color Codes 1 ANSI Calibration E = Type E J = Type J K = Type K N = Type N S = Type S T = Type T Note: Color coding will be to ANSI standards, unless specified. 2 3 14-36 B and S Gauge 4 Conductor Type/Tolerance 1 = Thermocouple grade, solid wire, standard tolerance 2 = Thermocouple grade, solid wire, special tolerance 3 = Thermocouple grade, stranded wire, standard tolerance 4 = Thermocouple grade, stranded wire, special tolerance 5 =, solid wire, standard tolerance 6 =, solid wire, special tolerance 7 =, stranded wire, standard tolerance 8 =, stranded wire, special tolerance Note: Stranded conductors will be seven strand constructions. Contact a Watlow representative for other configurations. 5 Metallic Overbraids (optional) S = Stainless steel N = Alloy 600 C = Tinned copper 6 7 8 Insulation Series Refer to insulation chart on page 4. 9 10 11 Color Codes Blank = ANSI/ASTM E230 (formally ANSI MC96.1) BSC = BS 1843 DIN = DIN 43710 JIS = JIS C 1610-1981 IEC = IEC 584-3 * Product normally shipped in 1,000 foot spools. Contact a Watlow representative for special packaging. Watlow and SERV-RITE are registered trademarks of Watlow Electric Manufacturing Company Teflon and Tefzel are registered trademarks of E.I. dupont de Nemours & Company. Chromel and Alumel are registered trademarks of Hoskins Manufacturing Company. 5

Find out more about Watlow and how we can provide thermal solutions for your company: Phone: 1-800-WATLOW2 (1-800-928-5692) E-mail: inquiry@watlow.com Web site: www.watlow.com Watlow Products and Technical Support Delivered Worldwide North American Technical Support & Sales Offices North America 1-800-WATLOW2 (1-800-928-5692) Asian Technical Support & Sales Offices Australia +61 3 9335 6449 China +86 21 3381 0188 Japan +81 3 3518 6630 Korea +82 2 2628 5770 Malaysia +60 3 8076 8745 Singapore +65 6773 9488 Taiwan +886 7 288 5168 European Technical Support & Sales Offices France +33 1 41 32 79 70 Germany +49 (0) 72 53 / 94 00-0 Italy +39 024588841 Spain +34 91 675 12 92 United Kingdom +44 (0) 115 964 0777 Latin American Technical Support & Sales Office Mexico +52 442 217 6235 About Watlow Watlow designs and manufactures industrial heaters, temperature sensors, controllers and system assemblies all of the components of a thermal system. Designing and manufacturing the complete thermal system allows Watlow to recommend, develop and deliver the optimum thermal solution for our customers equipment and process heat requirements. Watlow manufactures thermal systems for a broad range of industries including but not limited to: semiconductor processing, photovoltaics, diesel emmisions, aerospace, medical equipment and foodservice equipment. Watlow customers receive the highest level of technical engineering combined with exceptional customer service. Since 1922, Watlow has grown in product capability, market experience and global reach. We hold more than 200 patents and employ 2,000 employees working in 12 manufacturing facilities in the United States, Mexico, Europe and Asia. We also have sales offices in 15 countries around the world. Our company has grown at an exponential rate, but our commitment remains the same to provide our customers with superior products and services for their individual needs. Your Authorized Watlow Distributor is: 2009 2010 Watlow Electric Manufacturing Company RIC-WB-1110 RIC-