ROCKFON SYSTEM T24 X

Similar documents
ROCKFON SYSTEM ULTRALINE E

ROCKFON SYSTEM T24 A/E ECR

ROCKFON SYSTEM T24 A/E

Installation guide System X

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0)

Gyptone edge D1 system Installation manual

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Basic Suspension Systems

SECTION NON-STRUCTURAL METAL FRAMING

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

QUICK-LOCK QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems. QUICK-LOCK Ceiling systems. QUICK-LOCK Cross-Lock.

(Suited for seismic categories A, B, C, D, E, F)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

STANDARD PRODUCTS - CUSTOM LOOK

Ecophon Advantage E. covered with glass tissue. The edges are painted.

SECTION ACOUSTICAL PANEL CEILINGS

Knauf MF Suspended Ceilings

Ecophon Advantage A. and accessories. The Connect grid is manufactured from galvanized steel.

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE

Ecophon Focus Dg. System range. XL 1200x x x600. Size, mm. XL 1800x600. XL 2000x x600 T24 Thickness Inst. Diagr.

SECTION GYPSUM BOARD ASSEMBLIES

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

BORTOLOTTO ADDENDUM #2

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

Nouvelles Cliniques Nantaises, France, Visona Tangent Architect: A.I.A Architectes ingenieurs associes

Ecophon Focus E. Connect grid and accessories. The grid is manufactured from galvanized steel.

Integrated LIGHTING. Solutions

Optima Vector Plank. Installation Instructions. Ceiling

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

The Passive Fire Protection Handbook

OPTIMA Vector Plank Installation Instructions

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

EI 30 barriere Self contained fire protection EI 30 from above and below smoke impervious EN

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Integrated. Solutions

SECTION GYPSUM BOARD

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED

Post Style with ABS Real Tuff

All panels can be supplied in a range of styles, to suit the applications pictured below.

ECONO 200 INPLANT OFFICE

The extra strong, extra durable, sound resistant system that you can direct fix to

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03

SCHEDULE OF QUANTITIES INTERIOR WORKS FOR RACC,GADAG Description Qty. Unit Rate Amount

70S - 132S SUN LOUVRE. Sun Control Systems

Heavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

General technical terms and conditions of TAIM e.v. for. M e t a l c e i l i n g s

Ecophon Hygiene Meditec A

Technical Services Information Bureau

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

I-STUD Shaftwall System

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Click on image to enlarge.

Section GYPSUM DRYWALL

elevate your flexibility

Optima Vector Ultima Vector

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

Exterior. Flexible durability

A. Submit the following in addition to the standard requirements.

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

Noetop is a versatile, robust integrated formwork panel system. The basic panels incorporate the strongbacks and

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION

DICTATOR Lift Shaft System

Ecophon s level changes. allow creative solutions for acoustic ceilings

SECTION ACCORDION FOLDING PARTITIONS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION ACOUSTICAL PANEL CEILINGS. A. Section includes acoustical panels and exposed suspension systems for ceilings.

BoSS Climalite Camera and lighting tower

PARK HILL SCHOOL DISTRICT REQUEST FOR PROPOSAL Acoustic Ceiling Tiles

SHORTSPAN. Features. Components

About Everite and Nutec 2. Nutec Suspended Ceiling Board Features 4. Safety, Handling and Storage 5. General Design Criteria 6

1. Nonload-bearing steel framing members for gypsum board assemblies. 2. Gypsum board assemblies attached to steel framing.

Benefits.

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Axiom Building Perimeter System

duo installation guide DUO Exposed Grid Ceiling System

C05. S03. P02 P08 FireWall

Suspended ceiling. Lauder INEA. Process Bois

CEILING & WALL SYSTEMS

Staggered stud acoustic partition system

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

Section 10. Rendering, Plasterboard & Fibre Cement Sheeting

Ramps Vip Aldime WHAT DO VIP ALDIME RAMPS HAVE THAT OTHERS DO NOT?

Cold Rooms Kide

Gyptone BIG system Installation manual

ALBLItZ 70 S INSTRUCTION FOR ERECTION AND USE

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION RESILIENT SHEET FLOORING

Pittsburgh Corning ProVantage Glass Block Installation System Assembly Instructions

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES


Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

RMF Intercell. NBS Specification 2013 K41

Transcription:

System description ROCKFON SYSTEM T24 X Concealed ceiling system Continuous expression GRP SYSTE E asy integration of services X EDGE WAR YEARS IT LIM ED Quick and easy to install M NT Y L ow installation height and full demountability RA E legant, continuous ceiling expression

DESCRIPTION Rockfon System T24 X is a concealed ceiling system that provides an elegant, continuous ceiling expression and is used with X edge tiles. The system can either be installed as a suspended ceiling at the desired height using the Chicago Metallic T24 Click 2890 grid or installed directly to the soffit by using direct fixing brackets. In Rockfon System T24 X the Chicago Metallic T24 Click 2890 grid has a click connection provides quick and easy installation and demounting. The T profiles have a width of 24 mm, and all components are made of galvanised steel with a smooth, white surface concealed by Rockfon X edge tiles. The system includes main runners, cross tees, hangers and other necessary components. The main runners and cross tees have a uniform height of 38 mm, ensuring stability and easier integration of services. A number of accessories, lighting and ventilation solutions have been developed for Rockfon System T24 X. The system enables full demountability of the installed tiles. The system is characterised by symmetrical, fully independent tiles. Rockfon X edge tiles are available in different module sizes (see overview on page 3). The grid layout to be used depends on the choice of the module size (see layout possibilities on page 5). 5 7 3 6 max. 450 mm 2 1 1200 mm 1200 mm X1 22 22 X2 1.8 17 7.5 38 mm full height main runners and cross tees for stability and easy service integration. Click system providing quick and easy mounting and de-mounting. Concealed grid system with the symmetrical X edge tile ensuring quick installations in both directions. 2

SYSTEM COMPONENTS AND CONSUMPTION GUIDE TILE DIMENSION (MM) TILE CHICAGO METALLIC T24 CLICK 2890 WALL ANGLES ACCESSORIES 1 2 3 4 5 6 7 8 9 10 11 - Main runner T24 Click Cross tee T24 Click 600 Cross tee T24 Click 1200 Cross tee T24 Click 1800 W Shadow moulding wall angle CONSUMPTION/M² Perimeter wall angle trim Rigid angle hanger Wire suspension hanger Direct suspension clip Edge spring Edge wedge 600 x 600 2.78 pcs/m² 0.83 lm/m² 0.83 lm/m² 1.67 lm/m² - 1) 1) 0.70 pcs/m² 0.70 pcs/m² 2) 2) 1200 x 600 1.39 pcs/m² 0.83 lm/m² - 1.67 lm/m² - 1) 1) 0.70 pcs/m² 0.70 pcs/m² 2) 2) 1800 x 600 0.93 pcs/m² 0.55 lm/m² - - 1.67 lm/m² 1) 1) 0.70 pcs/m² 0.70 pcs/m² 2) 2) 1) Consumption depends on room size. 2) Edge springs and wedges are used to block the tile against the wall. When edge springs are used, make sure there is enough space between the tile and the wall to insert the spring. Use one spring per tile. TILE - X EDGE CHICAGO METALLIC T24 CLICK 2890 1. MAIN RUNNER T24 CLICK 3600 MM WALL ANGLES 2. CROSS TEE T24 CLICK 600 MM 5. W SHADOW MOULDING WALL ANGLE 3. CROSS TEE T24 CLICK 1200 MM 4. CROSS TEE T24 CLICK 1800 MM 6. PERIMETER WALL ANGLE TRIM ACCESSORIES 7. RIGID ANGLE HANGER 8. WIRE SUSPENSION HANGER 9. DIRECT SUSPENSION CLIP 10. EDGE SPRING 11. EDGE WEDGE 3

PERFORMANCE System load bearing capacity MAX. LOAD (KG/M²) HANGER DISTANCE (MM) MODULE SIZE (MM) MAX. 2.5MM DEFLECTION MAX. 4.0MM DEFLECTION 1200 600 x 600 9.9 16.5 1200 1200 x 600 10.9 17.9 1200 1800 x 600 3.3 5.7 For 1800 x 600 mm tiles the use of stabilising profiles is recommended in case extra load is applied on the system. Contact Rockfon for more info. The system s load capacity is determined from a max. deflection of the individual components corresponding to 1/500 of the span or the cumulative deflection of all structural components which does not exceed 2.5 or 4 mm. The load bearing capacity is given as regularly distributed load in kg / m 2, the weight of the tile is not included. Corrosion resistance Class B (EN13964) Demountability Tiles mounted in Rockfon System T24 X are fully demountable. Fire resistance Some Rockfon ceiling systems have been tested and classified in accordance with European norm EN 13501-2 and/or national norms. Please contact ROCKFON. 30 YEARS System warranty All Rockfon ceiling systems have a 30 year limited system warranty. Contact Rockfon for more information and conditions. COMPATIBLE TILES OVERVIEW Rockfon System T24 X is available with the following Rockfon tiles: DIMENSION (MM) TILES THICKNESS (MM) 600 X 600 1200 X 600 1800 X 600 Rockfon Blanka TM 22 Rockfon MediCare Plus 22 Rockfon Color-all 22 Rockfon Color-all Special 22 Other dimensions can be installed in Rockfon System T24 X. Please contact Rockfon. 4

GRID INSTALLATION Grid layout and hanger location Rockfon X edge tiles can be installed in Rockfon System T24 X. Some layout options are shown below depending on the size of the tile. 1200 mm 600 600 1200 600 3 3 1800 600 1 Main runner Cross tee Hanger 1 1 1 4 1200 mm 1200 mm 1800 mm Installation requirements During and after grid installation, it is important to check that T profiles are perfectly aligned horizontally. A maximum level difference of +/- 1 mm is recommended between profiles and should not be added. This tolerance is valid for all directions. It is also important to check the squareness of the angles between the main runners and cross tees. This can be easily done by comparing the measurements of the two diagonals. See recommended tolerances on the drawings to the right. L mm MODULE SIZE (L X W) DIAGONAL (D) TOLERANCE W mm D mm MM 600 x 600 814.6 1200 x 600 1309.5 +/- 0.5 1800 x 600 1980.3 5

TILE INSTALLATION 1. Slide the X1 edge of the tile into the T profile 2. Lift the upper side of the opposite X1 edge of the tile above the T profile 3. Pull the tile back 4. Drop the tile carefully into position MINIMUM INSTALLATION DEPTH (MM) Tiles installed in Rockfon System T24 X are demountable. The system is characterised by symmetrical, fully independent tiles. The installation depth is defined as the distance from the underside of the tile to the underside of the substrate, where the hangers are fixed. D is the minimum installation depth for easy tile installation and demountability. Mounting method Direct fixing T profiles with adjustable fixing bracket T profiles with hangers D = Minimum installation depth 66 mm; 96 mm; 116 mm 101-136 mm 161 mm D 6

PERIMETER FINISH OPTIONS Below are examples of perimeter finishing. Further details can be found on www.rockfon.co.uk 1. Perimeter finish with wall angle trim 2. Perimeter finish with W shadow moulding wall angle 3. Perimeter finish with aluminium W shadow moulding wall angle 4. Perimeter finish with edge clip to create a floating edge 7

SERVICE INTEGRATION Rockfon ceiling tiles are easy to cut and therefore it is very easy to integrate services in our ceiling tiles. The cut-outs can be made with a simple utility knife. When the system is load bearing, Rockfon recommends using a yoke or extra support arms that spread the weight of the service installation. Please be aware that, when installing a yoke or support arms, the tile is supported by the grid on only two sides. The size of the yoke should not be bigger than module 600 x 600 mm and the use of extra hangers to overcome deflection in the ceiling system is strongly recommended. When using support arms to spread the weight of the installation, Rockfon recommends spanning maximum 600 mm. When integrating (recessed) modular luminaires please take note of the X edge tile design and its relationship to the grid. Please refer to drawing C below for general installation principles. Ideally, the type of luminaire should be chosen in order to create an aesthetically pleasing integration and level ceiling surface. The typical exposed face size of the light fitting should be the relevant module size minus 1mm or 2mm. Pull up type fittings, with four short support arms - two on opposite sides, are recommended. The face of the X edge tile sits approximately 16 mm below, and conceals half, the table of grid. Ideally the integrated light fitting should have a degree of adjustability to ensure the face of the fitting is level with the tiles. Planning A thorough project plan will result in less re-work and less ceiling tile damage. Rockfon recommends discussing the installation thoroughly and well in advance with other installers that have to work in or near the suspended ceiling. By doing so damaged ceiling tiles and dirty spots on the finished ceiling surface can be reduced, which reduces costs on site. Overview load bearing capacity MAX. LOAD (KG/M²) HANGER DISTANCE (MM) MODULE SIZE (MM) MAX. 2.5MM DEFLECTION MAX. 4.0MM DEFLECTION 1200 600 x 600 9.9 16.5 1200 1200 x 600 10.9 17.9 1200 1800 x 600 3.3 5.7 When installing services in Rockfon System T24 X you should always follow local building regulations if more strict than the load bearing capacity guidelines Rockfon recommends in the above table and in the table on page 4. Small service integration; Spot- or downlight, speaker, ventilation etc. Big service integration; Downlight, speaker, ventilation, etc. WEIGHT OF INSTALLATIONS < 0.25KG/PCS 0.25 3.0KG/PCS > 3.0KG/PCS Drawing A Drawing B Suspend separately Drawing A Drawing B Suspend separately Modular lighting- or ventilation fixture Drawing C; System load bearing capacity (if evenly distributed over grid in kg/m 2 ) Contact your local Rockfon technical service for more information on suitable lighting fixtures and accessories and availability of CAD drawings of the different services integrated in Rockfon system T24 X. Special solutions with integrated services are, if available, shown on page 12 of this document; in the Tools section. 8

Drawing A The integration of a spotlight, smoke detector, speaker, etc. (weighing < 0.25kg/pcs). Metal yoke: Diameter = 2 x service diameter Thickness = 0.6 mm Drawing B The integration of a downlight, spotlight, smoke detector, loud speaker, etc. (weighing 0.25 3.0kg/pcs). Use of a plywood yoke to spread the load on the back of the tile (as shown in the detail) or use of support arms to spread the load to the grid system is strongly recommended. The use of additional hangers to reduce deflection is strongly recommended. Plywood yoke: Length = 594 mm (module size - 6 mm) Width = light diameter + 250 mm Thickness = 6-12 mm Drawing C The integration of a modular lighting fixture or air vent (evenly distributed over grid), weighing max. the system loading capacity. It is strongly recommended to suspend the service independently. 9

SPECIFIC SOLUTIONS DLC Clip A DLC clip can be used to connect profiles to one another without the use of cross tees to create multi-layer grid constructions. This is particularly useful to work around obstacles and services such as light fixtures, ventilation ducts and pipes when these interrupt the primary grid layer. For corridors or large tile dimensions, using a multi-layer grid layout will save on the amount of hangers and will lead to a quick and easy installation. 2 1 Making a two layer grid layout using DLC clips provides additional stiffening of the primary grid system. It is recommended to use such a layout without cross tees on the perimeter of concealed ceilings e.g. Rockfon System T24 X to ensure a perfectly concealed ceiling expression and fast installation. As shown on the drawing on the left, this construction facilitates the mounting of the last tile along the wall and in corridors. It ensures stability and thus perfect alignment of the tiles along the wall on the perimeter of the ceiling. In the example, the inner tile marked No.1 is mounted first and the tile marked No.2 is mounted subsequently. The example shows 600x600mm and 1200x600mm tiles. Hold down clip For maintaining tiles in place, Rockfon offers a range of hold-down clips. In smaller rooms, hallways, stairwells, etc. which can be exposed to air pressure differences between the ceiling void and room, it is recommended that ceiling tiles are clipped at the back. This is also recommended for cleaning purposes. 10

GENERAL INSTALLATION RECOMMENDATIONS Perimeter finishing Junction between ceiling and wall or other vertical surface The perimeter trim should be fastened to vertical surfaces at the required level using appropriate fixings replace at 300-450 mm centres. Ensure that butt joints between adjoining lengths of trim are neat and that the trim is free from kinks and remains true and level. For the best aesthetics, use as long a length of trim as possible. The minimum recommended cut length is 300 mm. Timber trims, timber shadow battens and metal Shadow mouldings should not be used with fire resisting/protecting ceilings. Junction between ceiling and curved vertical surface The use of a preformed curved perimeter trim is the most appropriate method. Rockfon can provide details of curved perimeter trims on request. Tiles We recommend the use of clean nitrile or PU coated gloves when installing Rockfon tiles in order to avoid fingerprint marking on the surface. Cutting is made easy with a sharp knife. For an optimum work environment, we recommend installers always observe common work practices and follow the installation advice as shown on our packaging. Installation of 1800 x 600 mm tiles is recommended to be carried out by two people. Note! Certain smooth matt surfaces are directional. To ensure consistency of the finished ceiling, it is important that all tiles are installed in one direction indicated by the arrow printed on the back of each tile. Corners Perimeter trims should be neatly mitred at all corner joints. Overlap mitres are acceptable on metal trims on internal corner joints unless specified otherwise. Suspension grid Unless specified otherwise, the ceiling should be set out symmetrically and where possible, perimeter tiles should be greater than 200 mm in width. The hangers should be fastened with appropriate top fixings and to the main runners at 1200 mm centres (or less with greater load). Main runners should be positioned at 1200 mm centres for 600 x 600 mm and 1200 x 600 mm module sizes. For 1800 x 600 mm module size, main runners are installed at 1800 mm centres. For proper grid installation, ensure the T profiles are perfectly aligned, horizontally and diagonals of modules are equal (see requirements and tolerances on page 5). Main runner joints should be staggered and there should be a hanger positioned within 150 mm of the fire expansion element/cut-out and within 450 mm of the end of the main runner where it terminates at a perimeter. Additional hangers may be necessary to support the weight of ceiling services. When using direct hangers, a fixing pin should be used to lock the hanger on to the bulb of the main runner. 11

TOOLS Rockfon has developed specific tools that are available on www.rockfon.co.uk For further information see the CAD library Generate specification texts for our products Explore our vast library of reference project 12

05.2017 All colour codes mentioned are based on the NCS - Natural Colour System property of and used on licence from NCS Colour AB, Stockholm 2010. Subject to alterations in range and product technology without prior notice. Rockfon accepts no responsibility for printing errors. Rockfon ROCKWOOL Limited T/A ROCKFON 14th Floor, Chiswick Tower, 389 Chiswick High Road, London, W4 4AL Tel: +44 (0) 208 222 7457 www.rockfon.co.uk