Code Compliance Research Report CCRR-0228

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

Code Compliance Research Report CCRR-0266

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

Code Compliance Research Report CCRR-0137

Code Compliance Research Report CCRR-0213

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

Alply CLASSIC WALL Architectural Insulated Panel Wall System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Code Compliance Research Report CCRR-0185

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Code Compliance Research Report CCRR-0194

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

Combustible Exterior Wall Cladding Systems: An ICC Perspective

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

Specifications for FL-100 Soffit Panel

Code Compliance Research Report CCRR-0101

Advantage ICF System Product Information Bulletin

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION PRE-ENGINEERED BUILDING INSULATION

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

CS-100 Guide Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

Guide Specification SDP 200

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

Product Data Sheet. Product: Benchmark Wall Liner System

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

Page 1 of 5

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS, INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

SECTION METAL ROOF PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

ATI Evaluation Service A Division of Architectural Testing Certification Services

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

TRIAD CORRUGATED METAL, INC.

ATI Evaluation Service A Division of Architectural Testing Certification Services

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: TEKNION LIMITED

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

Joint Evaluation Report ICC-ES (800) (562)

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

ELEVATION FOR DETAIL REFERENCE ONLY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

ATI Evaluation Service A Division of Architectural Testing Certification Services

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Transcription:

Code Compliance Research Report CCRR-0228 Issue Date: 05-09-2017 Renewal Date: 05-11-2018 Revision Date: 06-23-2017 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 40 00 Roofing and Siding Panels KINGSPAN INSULATED PANELS, INC. 726 SUMMERHILL DRIVE DELAND, FLORIDA 32724 www.kingspanpanels.com REPORT SUBJECT: Kingspan Foam Core Panels (200/300) Series 1.0 SCOPE OF EVALUATION This research report addresses compliance with the following Codes: 2012 International Building Code (IBC) Kingspan Foam Core Panels have been evaluated for the following properties: Structural Fire Resistance 2.0 USES Kingspan Foam Core Panels are intended for use as exterior non-load bearing wall cladding. The panels are used in locations where combustible, non-fire resistance rated building construction is permitted by the IBC and buildings of Type I, II, III or IV construction as further identified in Section 5.5. 3.0 DESCRIPTION 3.1. General Kingspan Foam Core Panels are sandwich panels with metal facings and a foamed-inplace Polyurethane foam plastic core. The panels are 42 inches wide and up to 50 feet in length and are available in thicknesses of 2 to 6 inches. Panels are formed with straight ends and double tongue-in-groove interlocking edges along the length of the panels. See Figures 1 and 2. 3.2. Panel Core The Polyurethane core is Kingspan Self-blend KSUSSB-01 produced by Kingspan and is continuously formed in the core of the panel. The core of the panel has a minimum density of 2.1 pcf. 3.3. Panel Facings Panel facings are 26, 24, or 22 gage steel conforming to: ASTM A653 SS Grade 33 with a G90 galvanized coating, ASTM A792 SS Grade 33 with class AZ-50 Galvalume coating or ASTM A240 304-series stainless steel with a minimum yield strength of 35 ksi. The panel facings are finished with Kynar ceramic polyester or Plastixol XL applied over a primer of epoxy. Panel facings are available in Flat, Striate, Fluted, and Minor Rib profiles. 4.0 PERFORMANCE CHARACTERISTICS 4.1. Allowable Load Capacity Allowable positive and negative out of plane panel transverse loads installed over a single span are based on panel thickness, stiffness, strength and fastener capacity as set forth in Table 2. 4.2. The foam plastic has a flame spread index and a smoke developed index not exceeding 25 and 450 respectively when tested in accordance with ASTM E84. 4.3. Panel finishes have a Class A flame spread and smoke density rating in accordance with IBC Section 803.1. 4.4. Wall assemblies constructed with Kingspan Foam Core Panels in accordance with Section 5.4 meet the conditions of acceptance of NFPA 285 in accordance with IBC Section 2603.5.5 for walls of any height in Type I, II, III or IV construction. 5.0 INSTALLATION 5.1. General Installation Panels are installed in either a vertical or horizontal orientation. The panels are fastened to steel framing support members with clips and fasteners as described in Section 5.2. Structural

Code Compliance Research Report CCRR-0228 Page 2 of 7 support members shall provide a minimum panel bearing width of 2-1/2 inches. 5.2. Fasteners Panels are attached to the steel supports with 1/4-4 TEK 3 HWH corrosion-resistant screws, 1 to 6 inches long and panel clips fabricated from 14 gage, galvanized steel. See Figure 3. 5.3. Sealant - Panel joints and trim are sealed with non-skinning butyl sealant. The sealant is applied at temperatures ranging from 40ºF to 120ºF. All surfaces must be clean and dry. A 1/4 inch bead of butyl sealant may be applied either in the factory or the field into one or both of the grooves of the panel side joints. Sealant is applied to side joints of adjacent panels before panel engagement. The panels are interlocked to make continuous sealant contact. Installation proceeds along the wall elevation with successive panels being in accordance with the manufacturer s installation instructions. 5.4. Flashing Metal flashing shall be installed in accordance with Section 1405.4 of the IBC including, but not limited to, panel ends, eaves, openings and corners. The flashing and trim are attached to the panels with 14 TEK 1 HWH or No. 10 by 3/4 inch Philips pan-head, self-tapping, self-drilling screws. Pop rivets may also be used in accordance with the manufacturer s installation instructions. 5.5. Stack Joint - Vertical panels shall be installed in accordance with the stack joint detail, see Figure 7. 5.6. Use on Exterior Walls of Type I, II, III or IV Construction - Panels may be used on exterior walls of buildings of Type I, II, III or IV construction of any height, when the construction conforms with the NFPA 285 Design Assembly described in Figure 8. 6.0 SUPPORTING EVIDENCE 6.1. ICC-ES Evaluation Report ESR-1143 in accordance with ICC-ES Acceptance Criteria for Sandwich Panels AC04, Acceptance Criteria for Sandwich Panel Adhesives AC05, and Acceptance Criteria for Foam Plastic Insulation AC12. 6.2. Documentation of an Intertek approved quality control system. 6.3. FM Approval - FM Approvals Standard for Exterior Wall Systems, Class Number 4881 including FM Approval Standard 4880. 6.4. Test reports in conformance with ASTM E84, NFPA 259 and NFPA 285. 7.0 CONDITIONS OF USE The Kingspan Foam Core Panels (200/300) Series described in this Research Report comply with the codes listed in Section 1.0 of this report, subject to the following conditions: 7.1. Installation must comply with this Research Report, the manufacturer s published installation instructions, and the applicable code. In the event of a conflict between the manufacturer s instructions and this report, this report governs. 7.2. Wall panel installation shall be limited to nonload bearing walls. 7.3. The foam core panels may be installed without the thermal barrier specified in 2603.4 of the IBC. 7.4. Panels may be installed in buildings of Type I, II, II and IV Construction as follows: 7.4.1. One-Story Buildings: Panels up to 4 inches thick in buildings equipped throughout with automatic sprinkler system in accordance with 903.3.1.1 of the IBC. 7.4.2. Buildings Of Any Height: Wall assemblies meeting the requirements of NFPA 285, described in Figure 8. 7.5. Details on wall framing must be approved prior to installation by the building code official. 7.6. Wind design loads determined from nominal design wind speeds (V asd) in accordance with Section 1609.3.1 of the IBC shall not exceed the maximum allowable design pressure given in Table 2. 7.7. All construction plans and calculations for load conditions must be submitted to the code official for approval. 7.8. Kingspan Foam Core Panels (200/300) Series are manufactured by Kingspan Insulated Panels manufacturing facility in Deland, Florida with inspections by Intertek.

Code Compliance Research Report CCRR-0228 Page 3 of 7 8.0 IDENTIFICATION The Kingspan Foam Core Panels described in this Research Report are identified by a marking bearing the following: 8.1. Report holder s name (Kingspan Insulated Panels Inc.). 8.2. Intertek Mark, and Code Compliance Research Report number (CCRR-0228). 8.4. Foam plastic insulation type. 8.5. Facing gage, flame spread and smoke developed rating. 8.6. Sealant manufacturer, product name, type, and expiration. 9.0 CODE COMPLIANCE RESEARCH REPORT USE 9.1. Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 9.2. Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 8.3. Approval Mark of FM Approvals. Reference to the Intertek website address: whdirectory.intertek.com is recommended to ascertain the current version and status of this report. This Code Compliance Research Report ( Report ) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.

Code Compliance Research Report CCRR-0228 Page 4 of 7 TABLE 1 (200/300) Series Panel Profiles Profile Panel Designation Exterior Interior 200 Inverted Rib (Fluted) Minor Rib 300 Minor Rib, Striated, Flat Minor Rib TABLE 2 (200/300) Series Allowable Positive and Negative Transverse Loads ( L / 180) (psf) 1,2,3,4,5 Fascia/Liner Steel Thickness 26/26 Gage Panel Thickness Span (feet) (Inches) 5 8 10 12 14 16 18 20 2 29 18 15 12 NP NP NP NP 2-1/2 29 18 15 12 10 NP NP NP 3 29 18 15 12 10 NP NP NP 4 29 18 15 12 10 NP NP NP 5 29 18 15 12 10 NP NP NP 6 29 18 15 12 10 NP NP NP 1 Wind pressure values are based on panels having No. 26 gage steel facing liners on both faces 2 Wind pressure is based on a single-span condition and L / 180 deflection limitation 3 The allowable loads are based on the lesser of deflection, and panel strength, with consideration of the effects of fastener location and fastener-to-panel connection on the allowable negative loads. 4 See Figures 1 and 2 for panel profiles and fastening details 5 NP=Not Permitted Figure 1 200 Series Figure 2 300 Series

Code Compliance Research Report CCRR-0228 Page 5 of 7 Figure 3 Galvanized Hidden Clip Figure 4 Clip Usage Detail Figure 5 Fastening Detail Figure 6 Installed 200/300 Profiles

Code Compliance Research Report CCRR-0228 Page 6 of 7 Figure 7 Vertical Panel Installation Stack Joint

Code Compliance Research Report CCRR-0228 Page 7 of 7 Figure 8 NFPA 285 Wall Assembly Kingspan Insulated Panels, Inc. Insulated Metal Wall Panels Kingspan Foam Core Panels (200/300) Series NFPA 285 (2012) Rating: Meets Requirements 1. CERTIFIED MANUFACTURER: Kingspan Insulated Panels Inc. CERTIFIED PRODUCT: Wall Panels Insulated Metal CERTIFIED MODEL: Kingspan Foam Core Panels (200/300) Series Panels Vertically oriented, 42 wide x 6 thick insulated metal panels installed to the exterior side of steel framing and attach at each panel joint to wall framing members using manufacturer s hidden fastener clips. Follow manufacturer s installation instructions. A. Panel Facings Min 26 GA G90 zinc or AZ50 zinc/aluminum alloy coated steel. B. Polyurethane Foam Core Cavity completely filled with Kingspan Selfblend KSUSSB-01 at a minimum density of 2.1 pcf. 2. SEALANT: Apply nominal 1/4 bead of Kingspan non-skinning butyl sealant in the female panel joints. Exterior joint sealant is optional. 3. FASTENER: Attach panels to each steel framing member with two #14-18x8 HWHSDS zinc coated self-tapping screws. 4. JOINTS AND SEAMS: Vertically oriented 42 in. wide panels when installed over openings will be positioned with the joints a minimum of 21 inches away from the centerline of the opening. Horizontal joints or seams are not within the scope of this evaluation. 5. FLASHING (Not Shown): The inside perimeter of wall panel openings (cutouts) shall be wrapped with 26 Ga C shaped steel flashing.