Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Similar documents
Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Sliding Patio Doors Brickmould Vinyl

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

Maximize your security, protection and energy efficiency

Casement Windows Montecito New Construction Window

Awning Windows Montecito New Construction Window

VINYL SINGLE HUNG WINDOW

Veka Evolutions Commercial Window Program

Picture/Radius Windows Montecito New Construction Window

En e r g e x El i t e Window Systems

Glazing Performance. Industry Certification and Test Standards SECTION DIRECTORY

Vinyl Windows and Doors

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

Series x Thermal Triple Set Storefront Framing

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

THE ULTIMATE HIGH PERFORMANCE NEW CONSTRUCTION WINDOWS AND PATIO DOORS

6110 Horizontal Sliding Windows

Engineered Specifically for New Construction Applications

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

TheArtisanSeries. by AMSCO Windows. amscowindows.com

Masters Grande Series Windows with a Masterful Blend of Style, Design & Energy Efficiency

MikronWood Thermal Advantage Composite Window System Ideal for new construction and replacement applications in colder temperature climates

Encompass by PELLA COMPETITIVELY PRICED VINYL WINDOWS AND PATIO DOORS

Richlin 500 Casement. Hayfield Window & Door HAYFIELD, MN 55940

Series Heavy Commercial Projected Window

The Aluminum Framed Monumental Folding/Paired Panel System

Series 510-I Thermal Heavy Commercial Projected Window

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

PRODUCT DESCRIPTION Titan / Tritan 6500 Series

SERIES DESCRIPTION MODEL PAGE

TESTING DATA. Decades Of Proven Performance gerkin.com

7520 Casement Windows

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

Milgard Windows & Doors. Training Module Product Specification Protocol

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

HomeMaker3 Windows and Doors

Exceed Your Expectations Today And Well Into the Future.

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

Architectural Manual

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

FRENCH DOOR VINYL SERIES 455 / 555

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

opus I efficiency weather tightness durability er tightness durability energy efficiency royalplast.ca

Fusion Welded, Maintenance Free, All Vinyl Frame and Sash Construction Energy Efficient ¾ Insulated Glass Standard Available Sizes: (Tip to Tip Frame

opus II efficiency weather tightness durability lity energy efficiency weather tightness er tightness durability energy efficiency royalplast.

The Alternative to Storefront. Gerkin Model 58F

THERMALLY BROKEN ALUMINUM SERIES

Architectural Manual

Impact-Resistant Windows and Doors. impact-resistant package

VINYL CLASSICS NORTHERN CLASSICS

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

SLIDING PATIO DOOR DESIGNS REHAU SYSTEM Construction Automotive Industry

SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS)

SERIES 3000/4000/5000

Insulated Glass Units

Storm Window Low-E Exterior Interior. energy solutions. up to 60% savings *

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

TMS 114 XT TECHNICAL MANUAL

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: GAMCO CORPORATION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

W i n d o w & D o o r

fusion urabilityenergy efficiency urabilityenergy efficiency urabilityenergy efficiency urabilityenergy efficiency

energywall e windows + patio

GLASS WINDOWS & DOORS. Please submit/upload plans in PDF format

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

System WV410 Storefront Window System

A FOLDING DOOR SERIES BY ROYAL

Beauty and Elegance Without the Maintenance.

TMS 152 / 152T / 152XT TECHNICAL MANUAL

SECTION ALUMINUM WINDOWS

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

LIFT AND SLIDE SYSTEM

THERMALLY BROKEN STEEL WINDOWS STEEL WINDOW INSTITUTE A STANDARD OF EXCELLENCE

PREMIUM VINYL WINDOWS AND DOORS FOR REPLACEMENT

wood EUROPEAN ARCHITECTURAL SUPPLY FINE WINDOWS FOR ALL SEASONS products Makrowin MW88 G2 21 Makrowin MW88 23 Makrowin MW78 25 Makrowin MW AluClad 27

Repair Maintenance Hangar Phase II August 2010

Embrace the long shadows of the late afternoon. Embrace your sense of style. Embrace the compliments with just a touch of humility.

BAY, BOW AND GARDEN WINDOWS

Windows are the essence of the home.

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

E-Wall System 5800, 5800-I

SL70 The Monumental Thermally Broken Aluminum Framed Folding System

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

SunWave Prismatic Skylights

WESTECK WINDOWS and DOORS

MGM Industries SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. Series 8010 Picture Window NCTL

Vinyl Replacement Windows and Doors

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

Transcription:

ECTIN DIRECTRY ize and performance summary Glazing performance Grille profiles and patterns ize tables Design Data Detailed Product Description Cross sections The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-1

BRAND UMMARY Pella 350 eries Fixed Frame windows feature an extruded, rigid PVC (polyvinyl chloride) frame with heatfused mitered corners for a fully welded corner assembly. The mootheam welded corners on the interior of the frame are virtually invisible. Fixed Windows meet industry standards for water infiltration and wind resistance and meet ENERGY TAR guidelines with dual-pane or triple-pane insulated glass. BLCK FRAME DEIGN 4-1/ Block or 3-1/4" Block Pocket Install 3-1/4" Block Pocket Install Frame allows a perfect fit into a 3-1/4" pocket when installed into an existing Double-Hung or ingle-hung wood frame from the interior. 4-1/ block frame can be used in new construction block or concrete walls. They may also be used in replacement of old aluminum or steel frame windows or pocket replacement into wood frames from the exterior. The block frames include interior and exterior accessory grooves. Custom sizes are available in 1/8" increments for a perfect fit. DUBLE-WALL 4-1/ Block FLUH Frame FLANGE 3-1/4" Block Pocket Install Replacement Frame Design The flush flange frame allows for easy replacement of old aluminum or steel frame windows without removing the existing frame head or jambs typically used with stucco exteriors in southwest arid climates. The frame depth is 4-1/ (overall wall depth of 4-1/16") includes interior accessory groove. Custom sizes are available in 1/8" increments for a perfect fit. NAIL FIN FRAME DEIGN With or Without Integrated -Channel Continuous fin with welded corners adds a protective weather barrier and allows for hassle-free installation. The standard 4-1/ frame depth includes interior and exterior accessory grooves. Nailing fin has a 1-7/16" setback from exterior face of window frame. Custom sizes are available in 1/8" increments for a perfect fit. 4-9/16" and 6-9/16" factory applied primed or clear jamb extensions are available. INTEGRAL 5/8" FLANGE FRAME The integral 5/8" flange frame can be used in new construction block or concrete walls. Commonly used in Florida and often referred to as "Florida Flange" frame. The frame depth is 4-1/ (overall wall depth of 3-7/8") includes interior accessory groove. Custom sizes are available in 1/8" increments for a perfect fit. With -Channel Without -Channel Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-2

ize and Performance Data PRDUCT ELECTIN GUIDE ize and Performance Data Features and ptions Features and ptions IZE tandard izes pecial izes Available Built on 1/8" Increments FRAME Nail Fin nly Nail Fin with -Channel 4-1/ Block 3-1/4" Block Pocket Install / Replacement Double-Wall Flush Flange Integral 5/8" Flange PERFRMANCE 1 tandard Performance Meets or Exceeds AAMA/WDMA Ratings Air Infiltration (cfm / ft2 of frame @ 1.57 psf wind pressure) Design Pressure Water Penetration Resistance Performance Upgrade Meets or Exceeds AAMA/WDMA Ratings Air Infiltration (cfm / ft2 of frame @ 1.57 psf wind pressure) Design Pressure Water Penetration Resistance ther Performance Criteria R-PG30 to C-PG60.05 30-60 psf 4.5 to 9.0 psf R-PG30 to C-PG60.05 30-60 psf 4.5 to 9.0 psf Forced Entry Resistance (Minimum ecurity Grade) 2 40 GLAZING (INULATING GLA) Glazing Type Dual-pane insulating glass Triple-pane insulating glass Insulated ptions / Low-E Types Advanced Low-E Naturalun Low-E undefense Low-E 3 Gray Low-E 3 Bronze-tinted Advanced Low-E 3 Additional Glazing ptions Annealed glass Tempered glass bscure glass 4 Hurricaneshield Impact-Resistant Products with laminated dual-pane insulating glass 1 Noise reduction glass (TC 3mm / 5mm combination) 3 Noise reduction laminated glass (non-impact) 3 Gas Fill / High Altitude Argon High altitude High altitude with argon 3 INTERIR / EXTERIR CLR White Interior/White Exterior Almond Interior/Almond Exterior White Interior/Brown Exterior White Interior/Fossil Exterior White Interior/Black Exterior White Interior/Brick Red Exterior White Interior/Hartford Green Exterior White Interior/Morning ky Gray Exterior White Interior/Poplar White Exterior White Interior/Portobello Exterior White Interior/Tan Exterior GRILLE Grilles-Between-the- 3/4" Contour 1" Contour Grille Patterns: Traditional, Prairie, Top Row, Custom - Equally Divided imulated-divided-light Grilles 3 (without spacer) 7/8" contour profile Grille Patterns: Traditional, Prairie, Top Row, Custom - Equally Divided = tandard; = ptional (1) Published performance data is for single unit only. Combinations require reinforcing mullion between units. (2) The higher the level, the greater the product's ability to resist forced entry. (3) Not available with Triple-pane glazing. (4) Contact your local Pella sales representative for current offering. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-3

PRDUCT ELECTIN GUIDE ound and Transmission Class ound Transmission Class and utdoor-indoor Transmission Class Frame ize Tested1 verall Glazing Thickness Exterior Thickness Glazing ystem Interior Thickness Third Pane Thickness TC Rating ITC Rating FIXED WINDW DUAL PANE INULATING GLA 48" x 60" 11/16" 3mm 3mm 26 22 48" x 60" 11/16" 3mm 5mm 30 25 FIXED WINDW NN-IMPACT LAMINATED INULATING GLA 48" x 60" 1" 5mm 10mm PVB 36 30 FIXED WINDW HURRICANEHIELD IMPACT-REITANT LAMINATED INULATING GLA 48" x 60" 1" 5 mm 11.7mm GP 2 35 31 48" x 60" 1" 5mm 11.7mm PVB 36 31 FIXED WINDW TRIPLE-PANE INULATING GLA 48" x 60" 1-1/4" 3mm 3mm 3mm 27 22 NTE: The presence of Low-E or argon have negligible effect on sound attenuation characteristics. (P) = Pending (1) ATM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are representative of all sizes of the same configuration. (2) GP used on units with frame area > 18 ft 2. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-4

GLAZING PERFRMANCE - TTAL UNIT 11/16" Insulating with 3mm 1" Insulating with 5mm Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone FIXED 11/16" IG N NC C 1 2 3 11/16" Advanced Low-E IG PEL-N-185-00563-00001 3 3 air 0.30 0.32 0.60 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00566-00001 0.30 0.29 0.54 57 with 7/8" imulated Divided Light grilles PEL-N-185-00569-00001 0.30 0.29 0.54 57 11/16" Advanced Low-E IG PEL-N-185-00554-00001 3 3 argon 0.25 0.31 0.60 61 27 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00557-00001 0.25 0.29 0.54 61 26 with 7/8" imulated Divided Light grilles PEL-N-185-00560-00001 0.25 0.29 0.54 61 26 11/16" Naturalun Low-E IG PEL-N-185-00509-00001 3 3 air 0.30 0.58 0.67 56 36 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00512-00001 0.30 0.52 0.60 56 33 with 7/8" imulated Divided Light grilles PEL-N-185-00515-00001 0.30 0.52 0.60 56 33 11/16" Naturalun Low-E IG PEL-N-185-00500-00001 3 3 argon 0.26 0.58 0.67 60 41 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00503-00001 0.26 0.53 0.60 60 38 with 7/8" imulated Divided Light grilles PEL-N-185-00506-00001 0.26 0.53 0.60 60 38 11/16" undefense Low-E IG PEL-N-185-00581-00001 3 3 air 0.29 0.24 0.55 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00584-00001 0.29 0.22 0.49 57 with 7/8" imulated Divided Light grilles PEL-N-185-00587-00001 0.29 0.22 0.49 57 11/16" undefense Low-E IG PEL-N-185-00572-00001 3 3 argon 0.25 0.23 0.55 61 22 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00575-00001 0.25 0.21 0.49 61 21 with 7/8" imulated Divided Light grilles PEL-N-185-00578-00001 0.25 0.21 0.49 61 21 FIXED 11/16" IG WITH 3MM/5MM GLA 11/16" Advanced Low-E IG PEL-N-185-00564-00001 3 5 air 0.31 0.32 0.59 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00567-00001 0.33 0.29 0.53 56 with 7/8" imulated Divided Light grilles PEL-N-185-00570-00001 0.31 0.29 0.53 56 11/16" Advanced Low-E IG PEL-N-185-00555-00001 3 5 argon 0.26 0.31 0.59 60 25 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00558-00001 0.28 0.28 0.53 60 21 with 7/8" imulated Divided Light grilles PEL-N-185-00561-00001 0.26 0.28 0.53 60 24 11/16" Naturalun Low-E IG PEL-N-185-00510-00001 3 5 air 0.32 0.56 0.67 55 32 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00513-00001 0.34 0.51 0.60 55 27 with 7/8" imulated Divided Light grilles PEL-N-185-00516-00001 0.32 0.51 0.60 55 30 11/16" Naturalun Low-E IG PEL-N-185-00501-00001 3 5 argon 0.27 0.56 0.67 59 39 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00504-00001 0.29 0.51 0.60 59 33 with 7/8" imulated Divided Light grilles PEL-N-185-00507-00001 0.27 0.51 0.60 59 36 11/16" undefense Low-E IG PEL-N-185-00582-00001 3 5 air 0.31 0.24 0.55 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00585-00001 0.33 0.22 0.49 56 with 7/8" imulated Divided Light grilles PEL-N-185-00588-00001 0.31 0.22 0.49 56 11/16" undefense Low-E IG PEL-N-185-00573-00001 3 5 argon 0.26 0.24 0.55 60 21 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00576-00001 0.28 0.21 0.49 60 17 with 7/8" imulated Divided Light grilles PEL-N-185-00579-00001 0.26 0.21 0.49 60 20 FIXED 1" IG 1" Advanced Low-E IG PEL-N-185-00622-00001 5 5 air 0.30 0.31 0.59 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00623-00001 0.30 0.28 0.52 57 with 7/8" imulated Divided Light grilles PEL-N-185-00624-00001 0.30 0.28 0.52 57 1" Advanced Low-E IG PEL-N-185-00619-00001 5 5 argon 0.26 0.31 0.59 61 25 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00620-00001 0.26 0.28 0.52 61 24 with 7/8" imulated Divided Light grilles PEL-N-185-00621-00001 0.26 0.28 0.52 61 24 1" Naturalun Low-E IG PEL-N-185-00604-00001 5 5 air 0.31 0.56 0.66 57 34 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00605-00001 0.31 0.51 0.59 57 31 with 7/8" imulated Divided Light grilles PEL-N-185-00606-00001 0.31 0.51 0.59 57 31 1" Naturalun Low-E IG PEL-N-185-00601-00001 5 5 argon 0.27 0.56 0.66 60 39 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00602-00001 0.27 0.51 0.59 60 36 with 7/8" imulated Divided Light grilles PEL-N-185-00603-00001 0.27 0.51 0.59 60 36 1" undefense Low-E IG PEL-N-185-00628-00001 5 5 air 0.29 0.24 0.54 58 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00629-00001 0.29 0.21 0.49 58 with 7/8" imulated Divided Light grilles PEL-N-185-00630-00001 0.29 0.21 0.49 58 1" undefense Low-E IG PEL-N-185-00625-00001 5 5 argon 0.25 0.23 0.54 61 22 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00626-00001 0.25 0.21 0.49 61 21 with 7/8" imulated Divided Light grilles PEL-N-185-00627-00001 0.25 0.21 0.49 61 21 Notes on following page Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-5

GLAZING PERFRMANCE - TTAL UNIT Triple-Pane Insulating 11/16" Insulating with 3mm/5mm Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Mid. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone TRIPLE-PANE N NC C 1 2 3 1-1/4" Advanced Low-E Triple-pane IG PEL-N-185-00689-00001 3 3 3 air 0.18 0.27 0.46 72 33 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00690-00001 0.18 0.24 0.42 72 32 1-1/4" Advanced Low-E Triple-pane IG PEL-N-185-00687-00001 3 3 3 argon 0.15 0.27 0.46 76 37 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00688-00001 0.15 0.24 0.42 76 35 1-1/4" Naturalun Low-E Triple-pane IG PEL-N-185-00673-00001 3 3 3 air 0.23 0.53 0.62 65 42 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00674-00001 0.23 0.47 0.55 65 38 1-1/4" Naturalun Low-E Triple-pane IG PEL-N-185-00671-00001 3 3 3 argon 0.20 0.52 0.62 69 45 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00672-00001 0.20 0.47 0.55 69 42 1-7/16" Advanced Low-E Triple-pane IG PEL-N-185-00701-00001 5 5 5 air 0.18 0.26 0.45 70 33 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00702-00001 0.18 0.24 0.40 70 32 1-7/16" Advanced Low-E Triple-pane IG PEL-N-185-00699-00001 5 5 5 argon 0.15 0.26 0.45 74 36 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00700-00001 0.15 0.24 0.40 74 35 1-7/16" Naturalun Low-E Triple-pane IG PEL-N-185-00693-00001 5 5 5 air 0.23 0.50 0.60 65 40 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00694-00001 0.23 0.45 0.54 65 37 1-7/16" Naturalun Low-E Triple-pane IG PEL-N-185-00691-00001 5 5 5 argon 0.20 0.49 0.60 67 43 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00692-00001 0.20 0.45 0.54 67 41 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-6

GLAZING PERFRMANCE - TTAL UNIT Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone TINTED GLAZING 11/16" IG N NC C 1 2 3 11/16" Bronze Advanced Low-E IG PEL-N-185-00595-00001 3 3 air 0.29 0.31 0.44 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00597-00001 0.29 0.28 0.40 57 with 7/8" imulated Divided Light grilles PEL-N-185-00599-00001 0.29 0.28 0.40 57 11/16" Bronze Advanced Low-E IG PEL-N-185-00589-00001 3 3 argon 0.25 0.31 0.44 61 27 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00591-00001 0.25 0.28 0.40 61 25 with 7/8" imulated Divided Light grilles PEL-N-185-00593-00001 0.25 0.28 0.40 61 25 11/16" Gray Low-E IG PEL-N-185-00545-00001 3 3 air 0.30 0.22 0.34 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00548-00001 0.30 0.20 0.31 57 with 7/8" imulated Divided Light grilles PEL-N-185-00551-00001 0.30 0.20 0.31 57 11/16" Gray Low-E IG PEL-N-185-00536-00001 3 3 argon 0.26 0.22 0.34 60 20 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00539-00001 0.26 0.20 0.31 60 19 with 7/8" imulated Divided Light grilles PEL-N-185-00542-00001 0.26 0.20 0.31 60 19 TINTED GLAZING 1" IG 1" Bronze Advanced Low-E IG PEL-N-185-00634-00001 5 5 air 0.30 0.28 0.38 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00635-00001 0.30 0.25 0.34 57 with 7/8" imulated Divided Light grilles PEL-N-185-00636-00001 0.30 0.25 0.34 57 1" Bronze Advanced Low-E IG PEL-N-185-00631-00001 5 5 argon 0.26 0.28 0.38 61 24 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00632-00001 0.26 0.25 0.34 61 22 with 7/8" imulated Divided Light grilles PEL-N-185-00633-00001 0.26 0.25 0.34 61 22 1" Gray Low-E IG PEL-N-185-00616-00001 5 5 air 0.30 0.21 0.33 57 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00617-00001 0.30 0.19 0.30 57 with 7/8" imulated Divided Light grilles PEL-N-185-00618-00001 0.30 0.19 0.30 57 1" Gray Low-E IG PEL-N-185-00613-00001 5 5 argon 0.27 0.21 0.33 60 19 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00614-00001 0.27 0.19 0.30 60 17 with 7/8" imulated Divided Light grilles PEL-N-185-00615-00001 0.27 0.19 0.30 60 17 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-7

GLAZING PERFRMANCE - TTAL UNIT Non-Impact Laminate Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone FIXED NN-IMPACT LAMINATE N NC C 1 2 3 1" Advanced Low-E PVB IG PEL-N-185-00652-00001 5 10 air 0.29 0.31 0.57 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00653-00001 0.29 0.28 0.51 56 with 7/8" imulated Divided Light grilles PEL-N-185-00654-00001 0.29 0.28 0.51 56 1" Advanced Low-E PVB IG PEL-N-185-00649-00001 5 10 argon 0.25 0.30 0.57 60 26 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00650-00001 0.25 0.28 0.51 60 25 with 7/8" imulated Divided Light grilles PEL-N-185-00651-00001 0.25 0.28 0.51 60 25 1" Naturalun Low-E PVB IG PEL-N-185-00640-00001 5 10 air 0.30 0.52 0.64 56 33 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00641-00001 0.30 0.47 0.58 56 30 with 7/8" imulated Divided Light grilles PEL-N-185-00642-00001 0.30 0.47 0.58 56 30 1" Naturalun Low-E PVB IG PEL-N-185-00637-00001 5 10 argon 0.26 0.52 0.64 59 38 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00638-00001 0.26 0.47 0.58 59 35 with 7/8" imulated Divided Light grilles PEL-N-185-00639-00001 0.26 0.47 0.58 59 35 1" undefense Low-E PVB IG PEL-N-185-00664-00001 5 10 air 0.28 0.24 0.53 57 19 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00665-00001 0.28 0.21 0.47 57 17 with 7/8" imulated Divided Light grilles PEL-N-185-00666-00001 0.28 0.21 0.47 57 17 1" undefense Low-E PVB IG PEL-N-185-00661-00001 5 10 argon 0.24 0.23 0.53 60 24 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00662-00001 0.24 0.21 0.47 60 22 with 7/8" imulated Divided Light grilles PEL-N-185-00663-00001 0.24 0.21 0.47 60 22 FIXED NN-IMPACT LAMINATE TINTED GLA 1" Bronze Advanced Low-E PVB IG PEL-N-185-00658-00001 5 10 air 0.29 0.29 0.33 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00659-00001 0.29 0.26 0.30 56 with 7/8" imulated Divided Light grilles PEL-N-185-00660-00001 0.29 0.26 0.30 56 1" Bronze Advanced Low-E PVB IG PEL-N-185-00655-00001 5 10 argon 0.25 0.29 0.33 60 26 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00656-00001 0.25 0.27 0.30 60 24 with 7/8" imulated Divided Light grilles PEL-N-185-00657-00001 0.25 0.27 0.30 60 24 1" Gray Advanced Low-E PVB IG PEL-N-185-00646-00001 5 10 air 0.29 0.21 0.32 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00647-00001 0.29 0.20 0.29 56 with 7/8" imulated Divided Light grilles PEL-N-185-00648-00001 0.29 0.20 0.29 56 1" Gray Advanced Low-E PVB IG PEL-N-185-00643-00001 5 10 argon 0.25 0.21 0.32 59 21 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00644-00001 0.25 0.19 0.29 59 20 with 7/8" imulated Divided Light grilles PEL-N-185-00645-00001 0.25 0.19 0.29 59 20 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-8

GLAZING PERFRMANCE - TTAL UNIT 3-1/4" Block Pocket Replacement Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone FIXED 11/16" IG N NC C 1 2 3 11/16" Advanced Low-E IG PEL-N-193-00301-00001 3 3 air 0.29 0.32 0.60 57 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00304-00001 0.29 0.29 0.54 57 with 7/8" imulated Divided Light grilles PEL-N-193-00307-00001 0.29 0.29 0.54 57 11/16" Advanced Low-E IG PEL-N-193-00292-00001 3 3 argon 0.25 0.32 0.60 62 27 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00295-00001 0.25 0.29 0.54 62 26 with 7/8" imulated Divided Light grilles PEL-N-193-00298-00001 0.25 0.29 0.54 62 26 11/16" Naturalun Low-E IG PEL-N-193-00247-00001 3 3 air 0.30 0.58 0.67 57 36 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00250-00001 0.30 0.53 0.60 57 33 with 7/8" imulated Divided Light grilles PEL-N-193-00253-00001 0.30 0.53 0.60 57 33 11/16" Naturalun Low-E IG PEL-N-193-00238-00001 3 3 argon 0.26 0.58 0.67 61 41 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00241-00001 0.26 0.53 0.60 61 38 with 7/8" imulated Divided Light grilles PEL-N-193-00244-00001 0.26 0.53 0.60 61 38 11/16" undefense Low-E IG PEL-N-193-00319-00001 3 3 air 0.29 0.24 0.55 58 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00322-00001 0.29 0.22 0.49 58 with 7/8" imulated Divided Light grilles PEL-N-193-00325-00001 0.29 0.22 0.49 58 11/16" undefense Low-E IG PEL-N-193-00310-00001 3 3 argon 0.24 0.23 0.55 62 24 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00313-00001 0.24 0.21 0.49 62 22 with 7/8" imulated Divided Light grilles PEL-N-193-00316-00001 0.24 0.21 0.49 62 22 FIXED 11/16" IG WITH 3MM/5MM GLA 11/16" Advanced Low-E IG PEL-N-193-00302-00001 3 5 air 0.31 0.32 0.59 56 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00305-00001 0.33 0.29 0.53 56 with 7/8" imulated Divided Light grilles PEL-N-193-00308-00001 0.31 0.29 0.53 56 11/16" Advanced Low-E IG PEL-N-193-00293-00001 3 5 argon 0.26 0.31 0.59 60 25 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00296-00001 0.28 0.28 0.53 60 21 with 7/8" imulated Divided Light grilles PEL-N-193-00299-00001 0.26 0.28 0.53 60 24 11/16" Naturalun Low-E IG PEL-N-193-00248-00001 3 5 air 0.32 0.56 0.67 55 32 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00251-00001 0.34 0.51 0.60 55 27 with 7/8" imulated Divided Light grilles PEL-N-193-00254-00001 0.32 0.51 0.60 55 30 11/16" Naturalun Low-E IG PEL-N-193-00239-00001 3 5 argon 0.27 0.56 0.67 60 39 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00242-00001 0.29 0.51 0.60 60 33 with 7/8" imulated Divided Light grilles PEL-N-193-00245-00001 0.27 0.51 0.60 60 36 11/16" undefense Low-E IG PEL-N-193-00320-00001 3 5 air 0.30 0.24 0.55 56 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00323-00001 0.33 0.22 0.49 56 with 7/8" imulated Divided Light grilles PEL-N-193-00326-00001 0.30 0.22 0.49 56 11/16" undefense Low-E IG PEL-N-193-00311-00001 3 5 argon 0.25 0.24 0.55 61 23 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00314-00001 0.27 0.22 0.49 61 19 with 7/8" imulated Divided Light grilles PEL-N-193-00317-00001 0.25 0.22 0.49 61 22 FIXED 1" IG 1" Advanced Low-E IG PEL-N-193-00360-00001 5 5 air 0.30 0.31 0.59 58 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00361-00001 0.30 0.28 0.52 58 with 7/8" imulated Divided Light grilles PEL-N-193-00362-00001 0.30 0.28 0.52 58 1" Advanced Low-E IG PEL-N-193-00357-00001 5 5 argon 0.26 0.31 0.59 61 25 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00358-00001 0.26 0.28 0.52 61 24 with 7/8" imulated Divided Light grilles PEL-N-193-00359-00001 0.26 0.28 0.52 61 24 1" Naturalun Low-E IG PEL-N-193-00342-00001 5 5 air 0.30 0.56 0.66 57 35 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00343-00001 0.30 0.51 0.59 57 32 with 7/8" imulated Divided Light grilles PEL-N-193-00344-00001 0.30 0.51 0.59 57 32 1" Naturalun Low-E IG PEL-N-193-00339-00001 5 5 argon 0.27 0.56 0.66 61 39 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00340-00001 0.27 0.51 0.59 61 36 with 7/8" imulated Divided Light grilles PEL-N-193-00341-00001 0.27 0.51 0.59 61 36 1" undefense Low-E IG PEL-N-193-00366-00001 5 5 air 0.29 0.24 0.54 58 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00367-00001 0.29 0.21 0.49 58 with 7/8" imulated Divided Light grilles PEL-N-193-00368-00001 0.29 0.21 0.49 58 1" undefense Low-E IG PEL-N-193-00363-00001 5 5 argon 0.25 0.23 0.54 62 22 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00364-00001 0.25 0.21 0.49 62 21 with 7/8" imulated Divided Light grilles PEL-N-193-00365-00001 0.25 0.21 0.49 62 21 Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-9

GLAZING PERFRMANCE - TTAL UNIT 3-1/4" Block Pocket Replacement Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Mid. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone TRIPLE-PANE N NC C 1 2 3 1-1/4" Advanced Low-E Triple-pane IG PEL-N-193-00397-00001 3 3 3 air 0.18 0.27 0.46 72 33 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00398-00001 0.18 0.24 0.42 72 32 1-1/4" Advanced Low-E Triple-pane IG PEL-N-193-00395-00001 3 3 3 argon 0.15 0.27 0.46 77 37 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00396-00001 0.15 0.24 0.42 77 35 1-1/4" Naturalun Low-E Triple-pane IG PEL-N-193-00381-00001 3 3 3 air 0.23 0.53 0.62 66 42 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00382-00001 0.23 0.47 0.55 66 38 1-1/4" Naturalun Low-E Triple-pane IG PEL-N-193-00379-00001 3 3 3 argon 0.20 0.53 0.62 69 46 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00380-00001 0.20 0.47 0.55 69 42 1-7/16" Advanced Low-E Triple-pane IG PEL-N-193-00409-00001 5 5 5 air 0.18 0.26 0.45 71 33 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00410-00001 0.18 0.24 0.40 71 32 1-7/16" Advanced Low-E Triple-pane IG PEL-N-193-00407-00001 5 5 5 argon 0.14 0.26 0.45 75 38 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00408-00001 0.14 0.24 0.40 75 37 1-7/16" Naturalun Low-E Triple-pane IG PEL-N-193-00401-00001 5 5 5 air 0.22 0.50 0.60 65 42 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00402-00001 0.22 0.45 0.54 65 39 1-7/16" Naturalun Low-E Triple-pane IG PEL-N-193-00399-00001 5 5 5 argon 0.19 0.49 0.60 68 45 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00400-00001 0.19 0.45 0.54 68 42 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-10

GLAZING PERFRMANCE - TTAL UNIT 3-1/4" Block Pocket Replacement Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone TINTED GLAZING 11/16" IG N NC C 1 2 3 11/16" Bronze Advanced Low-E IG PEL-N-193-00333-00001 3 3 air 0.29 0.31 0.44 58 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00335-00001 0.29 0.28 0.40 58 with 7/8" imulated Divided Light grilles PEL-N-193-00337-00001 0.29 0.28 0.40 58 11/16" Bronze Advanced Low-E IG PEL-N-193-00327-00001 3 3 argon 0.25 0.31 0.44 62 27 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00329-00001 0.25 0.28 0.40 62 25 with 7/8" imulated Divided Light grilles PEL-N-193-00331-00001 0.25 0.28 0.40 62 25 11/16" Gray Low-E IG PEL-N-193-00283-00001 3 3 air 0.30 0.22 0.34 57 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00286-00001 0.30 0.20 0.31 57 with 7/8" imulated Divided Light grilles PEL-N-193-00289-00001 0.30 0.20 0.31 57 11/16" Gray Low-E IG PEL-N-193-00274-00001 3 3 argon 0.26 0.22 0.34 61 20 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00277-00001 0.26 0.20 0.31 61 19 with 7/8" imulated Divided Light grilles PEL-N-193-00280-00001 0.26 0.20 0.31 61 19 TINTED GLAZING 1" IG 1" Bronze Advanced Low-E IG PEL-N-193-00372-00001 5 5 air 0.30 0.28 0.38 58 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00373-00001 0.30 0.25 0.34 58 with 7/8" imulated Divided Light grilles PEL-N-193-00374-00001 0.30 0.25 0.34 58 1" Bronze Advanced Low-E IG PEL-N-193-00369-00001 5 5 argon 0.26 0.28 0.38 62 24 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00370-00001 0.26 0.25 0.34 62 22 with 7/8" imulated Divided Light grilles PEL-N-193-00371-00001 0.26 0.25 0.34 62 22 1" Gray Low-E IG PEL-N-193-00354-00001 5 5 air 0.30 0.21 0.33 57 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00355-00001 0.30 0.20 0.30 57 with 7/8" imulated Divided Light grilles PEL-N-193-00356-00001 0.30 0.20 0.30 57 1" Gray Low-E IG PEL-N-193-00351-00001 5 5 argon 0.26 0.21 0.33 61 20 with 3/4" or 1" grilles-between-the-glass PEL-N-193-00352-00001 0.26 0.19 0.30 61 19 with 7/8" imulated Divided Light grilles PEL-N-193-00353-00001 0.26 0.19 0.30 61 19 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-11

HURRICANEHIELD IMPACT-REITANT GLAZING GLAZING PERFRMANCE - TTAL UNIT Thickness Type of Glazing NFRC Certified Product # (mm) Ext. Int. Gap Fill U-Factor Performance Values 1 HGC VLT CR haded Areas Meet ENERGY TAR Performance Criteria in Zones hown U.. Canada 2 Zone ER Zone 1" Advanced Low-E IG PVB PEL-N-185-00712-00001 5 12 air 0.30 0.31 0.57 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00713-00001 0.32 0.28 0.51 56 with 7/8" imulated Divided Light grilles PEL-N-185-00714-00001 0.30 0.28 0.51 56 N NC C 1 2 3 1" Advanced Low-E IG PVB PEL-N-185-00709-00001 5 12 argon 0.25 0.31 0.57 60 27 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00710-00001 0.27 0.28 0.51 60 23 with 7/8" imulated Divided Light grilles PEL-N-185-00711-00001 0.25 0.28 0.51 60 25 1" undefense Low-E IG PVB PEL-N-185-00730-00001 5 12 air 0.30 0.24 0.53 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00731-00001 0.31 0.22 0.47 56 with 7/8" imulated Divided Light grilles PEL-N-185-00732-00001 0.30 0.22 0.47 56 1" undefense Low-E IG PVB PEL-N-185-00727-00001 5 12 argon 0.25 0.23 0.53 60 22 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00728-00001 0.27 0.21 0.47 60 19 with 7/8" imulated Divided Light grilles PEL-N-185-00729-00001 0.25 0.21 0.47 60 21 BCURE GLAZING 1" Advanced Low-E IG PVB PEL-N-185-00724-00001 5 12 air 0.30 0.28 0.20 55 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00725-00001 0.32 0.25 0.18 55 with 7/8" imulated Divided Light grilles PEL-N-185-00726-00001 0.30 0.25 0.18 55 1" Advanced Low-E IG PVB PEL-N-185-00721-00001 5 12 argon 0.25 0.28 0.20 59 25 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00722-00001 0.27 0.26 0.18 59 22 with 7/8" imulated Divided Light grilles PEL-N-185-00723-00001 0.25 0.26 0.18 59 24 1" undefense Low-E IG PVB PEL-N-185-00736-00001 5 12 air 0.30 0.21 0.18 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00737-00001 0.32 0.20 0.17 56 with 7/8" imulated Divided Light grilles PEL-N-185-00738-00001 0.30 0.20 0.17 56 1" undefense Low-E IG PVB PEL-N-185-00733-00001 5 12 argon 0.25 0.22 0.18 60 22 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00734-00001 0.27 0.20 0.17 60 18 with 7/8" imulated Divided Light grilles PEL-N-185-00735-00001 0.25 0.20 0.17 60 20 TINTED GLAZING 1" Bronze Advanced Low-E IG PVB PEL-N-185-00718-00001 5 12 air 0.30 0.27 0.12 56 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00719-00001 0.32 0.25 0.10 56 with 7/8" imulated Divided Light grilles PEL-N-185-00720-00001 0.30 0.25 0.10 56 1" Bronze Advanced Low-E IG PVB PEL-N-185-00715-00001 5 12 argon 0.25 0.28 0.12 60 25 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00716-00001 0.27 0.25 0.10 60 21 with 7/8" imulated Divided Light grilles PEL-N-185-00717-00001 0.25 0.25 0.10 60 23 1" Gray Advanced Low-E IG PVB PEL-N-185-00706-00001 5 12 air 0.30 0.22 0.32 55 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00707-00001 0.32 0.20 0.29 55 with 7/8" imulated Divided Light grilles PEL-N-185-00708-00001 0.30 0.20 0.29 55 1" Gray Advanced Low-E IG PVB PEL-N-185-00703-00001 5 12 argon 0.26 0.21 0.32 59 20 with 3/4" or 1" grilles-between-the-glass PEL-N-185-00704-00001 0.28 0.19 0.29 59 16 with 7/8" imulated Divided Light grilles PEL-N-185-00705-00001 0.26 0.19 0.29 59 19 R-Value = 1/U-Factor HGC = olar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones (1) Glazing performance values are calculated based on NFRC 100, NFRC 200 and NFRC 500. ENERGY TAR values are updated to 2016 (Version 6) criteria. (2) The values shown are based on Canada's updated ENERGY TAR 2015 initiative. Based on unit size, some products will use 2.5mm glass that may have improved glazing performance from what is shown. ee the Product Performance section for more detailed information or visit www.energystar.gov for Energy tar guidelines. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-12

HURRICANEHIELD IMPACT-REITANT Fixed Window For a complete list of the Hurricanehield Impact-Resistant Glazing ratings, refer to the Coastal and High Winds section. Certification Results 1 Product Design Pressure Large Missile Rating D Minimum Maximum Hallmark Certified Miami-Dade County Approved (NA) Florida Product Approval ystem (FPA) Texas Department of Insurance (TDI) FIXED UNIT 1" Insulated PVB + 60 / - 65 + 60 / - 65 411-H-1408 12-0924.02 FL15939 WIN-1739 1" Insulated GP + 60 / - 65 + 60 / - 65 411-H-1408 12-0924.02 FL15939 WIN-1739 UNIT ECTIN H 4 1/ AW [114] 3 3/16" [82] H HEAD 2 3/8" [60] ILL 1 5/16" [33] 1 15/16" [49] FRAME HEIGHT 3 3/16" [82] 1 7/8" [48] 1 5/16" [33] 4 1/ AW [114] 2 3/8" [60] AMB FRAME WIDTH (1) Published performance data is for single unit only. ee Design Data pages for specific product performance class and grade values. All sizes and glass types are tested for air/water/structural and impact-resistance, and are certified for wind zone 4, large missile rating D. Florida Product Approval ystem number not needed if Miami-Dade County approved. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-13

GRILLE TYPE Grille Profiles GRILLE-BETWEEN-THE-GLA Grilles-Between-the- IMULATED-DIVIDED-LIGHT imulated Divided Light GRILLE 3/4" 1" 3/4" 1" 7/8" 3/4" Contour GBG 1" Contour GBG 3/4" Contour GBG 1" Contour GBG 7/8" DL Grille Patterns PRAIRIE LITE PATTERN Prairie - Approximately 4" from edge of sash to center of bar - Minimum actual glass is 13" 9-Lite Prairie THER AVAILABLE PATTERN Traditional - pecify number of lites. - Grilles must be equally divided on visible glass. - Minimum 6" x 6". Top Row - tandard visible glass to separator bar must be 1/2 upper actual glass Traditional Top Row Custom Equally Divided For traditional patterns, see size tables. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-14

PECIAL IZE FRAME DIMENIN Composite Assemblies Miscellaneous Formulas RECTANGLE 2-WIDE CMPITE WITH INTEGRAL MULLIN 3-WIDE CMPITE WITH INTEGRAL MULLIN MINIMUM 11-1/ W x 11-1/ H (292 x 292) MAXIMUM 11 W x 96" H (2 845 x 2 438) MINIMUM 12-1/ W x 11-1/ H (597 x 292) MAXIMUM 11 W x 73-1/ H (2 845 x 1 867) MINIMUM 35-1/ W x 11-1/ H (902 x 292) MAXIMUM 11 W x 73-1/ H (2 845 x 1 867) General Notes: To convert areas to square meters (m 2 ), multiply square feet by 0.0929. Rough pening Frame Dimension + 1/. Keep frame di men sions to the near est 1/4" increment Tempered glass must measure > 18-1/2 diagonally. Performance Class and Grade for 2-wide and 3-wide composite varies based on size. LC-PG25 to LC-PG60. Bronze limited to 22 ft 2. Miscellaneous Formulas VIIBLE GLA Width = Frame 3-15/16" Height = Frame 3-15/16" ACTUAL GLA Width = Frame 2-13/16" Height = Frame 2-13/16" Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-15

IZE TABLE (462) (457) (610) (711) (762) (813) (914) (1 219) (343) (445) (597) (699) (749) (800) (902) (1 207) pening 1' 1' 6" 2' 0" 2' 4" 2' 6" 2' 8" 3' 0" 4' 0" Frame 13 17 23 27 29 31 35 47 1-2/1-2 1-6/1-2 2-0/1-2 2-4/1-2 2-6/1-2 2-8/1-2 3-0/1-2 4-0/1-2 1-2/1-6 1-2/2-0 1-2/3-0 1-6/1-6 1-6/2-0 1-6/3-0 2-0/1-6 2-0/2-0 2-0/3-0 2-4/1-6 2-4/2-0 2-4/3-0 2-6/1-6 2-6/2-0 2-8/1-6 2-8/2-0 3-0/1-6 3-0/2-0 2-6/3-0 2-8/3-0 3-0/3-0 4-0/1-6 4-0/2-0 4-0/3-0 1-2/3-2 1-6/3-2 2-0/3-2 2-4/3-2 2-6/3-2 2-8/3-2 3-0/3-2 4-0/3-2 1-2/3-6 1-6/3-6 2-0/3-6 2-4/3-6 2-6/3-6 2-8/3-6 3-0/3-6 4-0/3-6 1-2/3-10 1-6/3-10 2-0/3-10 2-4/3-10 2-6/3-10 2-8/3-10 3-0/3-10 4-0/3-10 1-2/4-0 1-6/4-0 2-0/4-0 2-4/4-0 2-6/4-0 2-8/4-0 3-0/4-0 4-0/4-0 1-2/4-4 1-6/4-4 2-0/4-4 2-4/4-4 2-6/4-4 2-8/4-4 3-0/4-4 4-0/4-4 1-2/4-6 1-6/4-6 2-0/4-6 2-4/4-6 2-6/4-6 2-8/4-6 3-0/4-6 4-0/4-6 1-2/5-0 1-6/5-0 2-0/5-0 2-4/5-0 2-6/5-0 2-8/5-0 3-0/5-0 4-0/5-0 1-2/5-2 1-6/5-2 2-0/5-2 2-4/5-2 2-6/5-2 2-8/5-2 3-0/5-2 4-0/5-2 1-2/5-6 1-6/5-6 2-0/5-6 2-4/5-6 2-6/5-6 2-8/5-6 3-0/5-6 4-0/5-6 (1 829) (1 816) 6' 0" 71 (462) (343) (1 676) (1 664) 5' 6" 65 (1 575) (1 562) 5' 61 (457) (445) (610) (597) (914) (902) (965) (953) (1 067) (1 054) (1 168) (1 156) (1 219) (1 207) (1 321) (1 308) (1 372) (1 359) (1 524) (1 511) 1' 1' 6" 2' 0" 3' 0" 3' 3' 6" 3' 10" 4' 0" 4' 4" 4' 6" 5' 0" 1 / 53 1 / 2 " 51 1 / 2 " 47 1 / 2 " 45 1 / 2 " 41 1 / 2 " 37 1 / 2 " 35 1 / 2 " 23 1 / 2 " 17 1 / 2 " 13 1/ 2 " 59 1-2/6-0 1-6/6-0 2-0/6-0 2-4/6-0 2-6/6-0 2-8/6-0 3-0/6-0 4-0/6-0 Not to scale. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-16

IZE TABLE pening (1 372) (1 359 4' 6" (1 524) (1 511) 5' 0" (1 829) (1 816) 6' 0" (2 134) (2 121) Frame 53 59 71 83 95 7' 0" (2 438) (2 426) 8' 0" (462) (343) (457) (445) 4-6/1-2 4-6/1-6 4-6/2-0 4-6/3-0 4-6/3-2 4-6/3-6 4-6/3-10 4-6/4-0 4-6/4-4 4-6/4-6 5-0/1-2 5-0/1-6 5-0/2-0 5-0/3-0 5-0/3-2 5-0/3-6 5-0/3-10 5-0/4-0 5-0/4-4 5-0/4-6 6-0/1-2 6-0/1-6 6-0/2-0 6-0/3-0 6-0/3-2 6-0/3-6 6-0/3-10 6-0/4-0 6-0/4-4 6-0/4-6 7-0/1-2 7-0/1-6 7-0/2-0 7-0/3-0 7-0/3-2 7-0/3-6 7-0/3-10 7-0/4-0 7-0/4-4 7-0/4-6 8-0/1-2 8-0/1-6 8-0/2-0 8-0/3-0 8-0/3-2 8-0/3-6 8-0/3-10 8-0/4-0 8-0/4-4 8-0/4-6 4-6/5-0 5-0/5-0 6-0/5-0 7-0/5-0 8-0/5-0 4-6/5-2 5-0/5-2 6-0/5-2 7-0/5-2 4-6/5-6 5-0/5-6 6-0/5-6 7-0/5-6 (1 829) (1 816) 6' 0" 71 (1 676) (1 664) 5' 6" 65 (1 575) (1 562) 5' 61 (610) (597) (914) (902) (965) (953) (1 067) (1 054) (1 168) (1 156) (1 219) (1 207) (1 321) (1 308) (1 372) (1 359) (1 524) (1 511) 1' 1' 6" 2' 0" 3' 0" 3' 3' 6" 3' 10" 4' 0" 4' 4" 4' 6" 5' 0" 1 / 53 1 / 2 " 51 1 / 2 " 47 1 / 2 " 45 1 / 2 " 41 1 / 2 " 37 1 / 2 " 35 1 / 2 " 23 1 / 2 " 17 1 / 2 " 13 1/ 2 " 59 4-6/6-0 5-0/6-0 6-0/6-0 Not to scale. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-17

IZE TABLE 5/8" Integral Flange Call ize 1 H3 2 3 D2 Masonry 19 7/ 8" 27 1/ 4" 37 3/ 4" 53 7/ 8" 74 3/ 4" Buck 18 3/ 8" 25 3/ 4" 36 1/ 4" 52 3/ 8" 73 1/ 4" Frame 18 1/ 8" 25 36" 52 1/ 8" 73" Tip to Tip 19 1/ 8" 26 37" 53 1/ 8" 74" 3 2 26" 1/ 4" 25 25" 26" 3/ 8" 5/ 8" 3/ 8" 3/ 8" 350FL-12 350FL H32 350FL-22 350FL-32 350FL-D22 6 5 4 50 38 5/ 8" 76" 63" 37 37 38 7/ 8" 5/ 8" 5/ 8" 49 49 50 1/ 4" 62 1/ 4" 75 6 63" 75" 76" 350FL-13 350FL-14 350FL-15 350FL-H33 350FL-H34 350FL-H35 350FL-23 350FL-24 350FL-25 350FL-33 350FL-34 350FL-35 350FL-D23 350FL-D24 350FL-16 350FL-H36 350FL-26 350FL-36 Not to scale. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-18

DEIGN DATA ingle Units INGLE FIXED UNIT Call ut Width (Inches) Frame Height (Inches) Visible Ft2 tandard Thickness (mm) Performance Class & Grade 1 Annealed Tempered tandard Upgrade 2 1-2/1-2 13-1/2 13-1/2 0.6 2.5 3 CW40 CW60 / CW50 1-2/1-6 13-1/2 17-1/2 0.9 2.5 3 CW40 CW60 / CW50 1-2/2-0 13-1/2 23-1/2 1.3 2.5 3 CW40 CW60 / CW50 1-2/3-0 13-1/2 35-1/2 2.1 2.5 3 CW40 CW60 / CW50 1-2/3-2 13-1/2 37-1/2 2.2 2.5 3 CW40 CW60 / CW50 1-2/3-6 13-1/2 41-1/2 2.5 2.5 3 CW40 CW60 / CW50 1-2/3-10 13-1/2 45-1/2 2.8 2.5 3 CW40 CW60 / CW50 1-2/4-0 13-1/2 47-1/2 2.9 2.5 3 CW40 CW60 / CW50 1-2/4-4 13-1/2 51-1/2 3.2 2.5 3 CW40 CW60 / CW50 1-2/4-6 13-1/2 53-1/2 3.3 2.5 3 CW40 CW60 / CW50 1-2/5-0 13-1/2 59-1/2 3.7 3 3 CW40 CW60 / CW50 1-2/5-2 13-1/2 61-1/2 3.8 3 3 CW40 CW60 / CW50 1-2/5-6 13-1/2 65-1/2 4.1 3 3 CW40 CW60 / CW50 1-2/6-0 13-1/2 71-1/2 4.5 3 3 CW40 CW60 / CW50 1-6/1-2 17-1/2 13-1/2 0.9 2.5 3 CW40 CW60 / CW50 1-6/1-6 17-1/2 17-1/2 1.3 2.5 3 CW40 CW60 / CW50 1-6/2-0 17-1/2 23-1/2 1.8 2.5 3 CW40 CW60 / CW50 1-6/3-0 17-1/2 35-1/2 3.0 2.5 3 CW40 CW60 / CW50 1-6/3-2 17-1/2 37-1/2 3.2 2.5 3 CW40 CW60 / CW50 1-6/3-6 17-1/2 41-1/2 3.5 2.5 3 CW40 CW60 / CW50 1-6/3-10 17-1/2 45-1/2 3.9 2.5 3 CW40 CW60 / CW50 1-6/4-0 17-1/2 47-1/2 4.1 2.5 3 CW40 CW60 / CW50 1-6/4-4 17-1/2 51-1/2 4.5 2.5 3 CW40 CW60 / CW50 1-6/4-6 17-1/2 53-1/2 4.7 2.5 3 CW40 CW60 / CW50 1-6/5-0 17-1/2 59-1/2 5.2 2.5 3 CW40 CW60 / CW50 1-6/5-2 17-1/2 61-1/2 5.4 2.5 3 CW40 CW60 / CW50 1-6/5-6 17-1/2 65-1/2 5.8 3 3 CW40 CW60 / CW50 1-6/6-0 17-1/2 71-1/2 6.4 3 3 CW40 CW60 / CW50 2-0/1-2 23-1/2 13-1/2 1.3 2.5 3 CW40 CW60 / CW50 2-0/1-6 23-1/2 17-1/2 1.8 2.5 3 CW40 CW60 / CW50 2-0/2-0 23-1/2 23-1/2 2.7 2.5 3 CW40 CW60 / CW50 2-0/3-0 23-1/2 35-1/2 4.3 2.5 3 CW40 CW60 / CW50 2-0/3-2 23-1/2 37-1/2 4.6 2.5 3 CW40 CW60 / CW50 2-0/3-6 23-1/2 41-1/2 5.1 2.5 3 CW40 CW60 / CW50 2-0/3-10 23-1/2 45-1/2 5.6 3 3 CW40 CW60 / CW50 2-0/4-0 23-1/2 47-1/2 5.9 3 3 CW40 CW60 / CW50 2-0/4-4 23-1/2 51-1/2 6.5 3 3 CW40 CW60 / CW50 2-0/4-6 23-1/2 53-1/2 6.7 3 3 CW40 CW60 / CW50 2-0/5-0 23-1/2 59-1/2 7.5 3 3 CW40 CW60 / CW50 2-0/5-2 23-1/2 61-1/2 7.8 3 3 CW40 CW60 / CW50 2-0/5-6 23-1/2 65-1/2 8.4 3 3 CW40 CW60 / CW50 2-0/6-0 23-1/2 71-1/2 9.2 3 3 CW40 CW60 / CW50 2-4/1-2 27-1/2 13-1/2 1.6 2.5 3 CW40 CW60 / CW50 2-4/1-6 27-1/2 17-1/2 2.2 2.5 3 CW40 CW60 / CW50 2-4/2-0 27-1/2 23-1/2 3.2 2.5 3 CW40 CW60 / CW50 2-4/3-0 27-1/2 35-1/2 5.2 2.5 3 CW40 CW60 / CW50 2-4/3-2 27-1/2 37-1/2 5.5 2.5 3 CW40 CW60 / CW50 2-4/3-6 27-1/2 41-1/2 6.1 2.5 3 CW40 CW60 / CW50 2-4/3-10 27-1/2 45-1/2 6.8 2.5 3 CW40 CW60 / CW50 1 of 4 Miscellaneous Formulas VIIBLE GLA ACTUAL GLA Width = Frame 3-15/16" Height = Frame 3-15/16" Width = Frame 2-13/16" Height = Frame 2-13/16" (1) Maximum performance when glazed with the appropriate glass thickness. (2) econd value, where shown, is for single units with a nail frame. To convert areas to square meters (m²), multiply square feet by 0.0929. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-19

DEIGN DATA ingle Units INGLE FIXED UNIT Call ut Width (Inches) Frame Height (Inches) Visible Ft2 tandard Thickness (mm) Performance Class & Grade 1 Annealed Tempered tandard Upgrade 2 2-4/4-0 27-1/2 47-1/2 7.1 2.5 3 CW40 CW60 / CW50 2-4/4-4 27-1/2 51-1/2 7.8 2.5 3 CW40 CW60 / CW50 2-4/4-6 27-1/2 53-1/2 8.1 3 3 CW40 CW60 / CW50 2-4/5-0 27-1/2 59-1/2 9.1 3 3 CW40 CW60 / CW50 2-4/5-2 27-1/2 61-1/2 9.4 3 3 CW40 CW60 / CW50 2-4/5-6 27-1/2 65-1/2 10.1 3 3 CW40 CW60 / CW50 2-4/6-0 27-1/2 71-1/2 11.1 3 3 CW40 CW60 / CW50 2-6/1-2 29-1/2 13-1/2 1.7 2.5 3 CW40 CW60 / CW50 2-6/1-6 29-1/2 17-1/2 2.4 2.5 3 CW40 CW60 / CW50 2-6/2-0 29-1/2 23-1/2 3.5 2.5 3 CW40 CW60 / CW50 2-6/3-0 29-1/2 35-1/2 5.6 2.5 3 CW40 CW60 / CW50 2-6/3-2 29-1/2 37-1/2 6.0 2.5 3 CW40 CW60 / CW50 2-6/3-6 29-1/2 41-1/2 6.7 2.5 3 CW40 CW60 / CW50 2-6/3-10 29-1/2 45-1/2 7.4 2.5 3 CW40 CW60 / CW50 2-6/4-0 29-1/2 47-1/2 7.7 2.5 3 CW40 CW60 / CW50 2-6/4-4 29-1/2 51-1/2 8.4 3 3 CW40 CW60 / CW50 2-6/4-6 29-1/2 53-1/2 8.8 3 3 CW40 CW60 / CW50 2-6/5-0 29-1/2 59-1/2 9.9 3 3 CW40 CW60 / CW50 2-6/5-2 29-1/2 61-1/2 10.2 3 3 CW40 CW60 / CW50 2-6/5-6 29-1/2 65-1/2 10.9 3 3 CW40 CW60 / CW50 2-6/6-0 29-1/2 71-1/2 12.0 3 3 CW40 CW60 / CW50 2-8/1-2 31-1/2 13-1/2 1.8 2.5 3 CW40 CW60 / CW50 2-8/1-6 31-1/2 17-1/2 2.6 2.5 3 CW40 CW60 / CW50 2-8/2-0 31-1/2 23-1/2 3.7 2.5 3 CW40 CW60 / CW50 2-8/3-0 31-1/2 35-1/2 6.0 2.5 3 CW40 CW60 / CW50 2-8/3-2 31-1/2 37-1/2 6.4 2.5 3 CW40 CW60 / CW50 2-8/3-6 31-1/2 41-1/2 7.2 2.5 3 CW40 CW60 / CW50 2-8/3-10 31-1/2 45-1/2 8.0 2.5 3 CW40 CW60 / CW50 2-8/4-0 31-1/2 47-1/2 8.3 2.5 3 CW40 CW60 / CW50 2-8/4-4 31-1/2 51-1/2 9.1 3 3 CW40 CW60 / CW50 2-8/4-6 31-1/2 53-1/2 9.5 3 3 CW40 CW60 / CW50 2-8/5-0 31-1/2 59-1/2 10.6 3 3 CW40 CW60 / CW50 2-8/5-2 31-1/2 61-1/2 11.0 3 3 CW40 CW60 / CW50 2-8/5-6 31-1/2 65-1/2 11.8 3 3 CW40 CW60 / CW50 2-8/6-0 31-1/2 71-1/2 12.9 3 3 CW40 CW60 / CW50 3-0/1-2 35-1/2 13-1/2 2.1 2.5 3 CW40 CW60 / CW50 3-0/1-6 35-1/2 17-1/2 3.0 2.5 3 CW40 CW60 / CW50 3-0/2-0 35-1/2 23-1/2 4.3 2.5 3 CW40 CW60 / CW50 3-0/3-0 35-1/2 35-1/2 6.9 2.5 3 CW40 CW60 / CW50 3-0/3-2 35-1/2 37-1/2 7.4 2.5 3 CW40 CW60 / CW50 3-0/3-6 35-1/2 41-1/2 8.2 2.5 3 CW40 CW60 / CW50 3-0/3-10 35-1/2 45-1/2 9.1 3 3 CW40 CW60 / CW50 3-0/4-0 35-1/2 47-1/2 9.5 3 3 CW40 CW60 / CW50 3-0/4-4 35-1/2 51-1/2 10.4 3 3 CW40 CW60 / CW50 3-0/4-6 35-1/2 53-1/2 10.9 3 3 CW40 CW60 / CW50 3-0/5-0 35-1/2 59-1/2 12.2 3 3 CW40 CW60 / CW50 3-0/5-2 35-1/2 61-1/2 12.6 3 3 CW40 CW60 / CW50 3-0/5-6 35-1/2 65-1/2 13.5 3 3 CW40 CW60 / CW50 3-0/6-0 35-1/2 71-1/2 14.8 5 3 CW40 CW60 / CW50 2 of 4 (1) Maximum performance when glazed with the appropriate glass thickness. (2) econd value, where shown, is for single units with a nail frame. To convert areas to square meters (m²), multiply square feet by 0.0929. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-20

DEIGN DATA ingle Units INGLE FIXED UNIT Call ut Width (Inches) Frame Height (Inches) Visible Ft2 tandard Thickness (mm) Performance Class & Grade 1 Annealed Tempered tandard Upgrade 2 4-0/1-2 47-1/2 13-1/2 2.9 2.5 3 CW40 CW60 / CW50 4-0/1-6 47-1/2 17-1/2 4.1 2.5 3 CW40 CW60 / CW50 4-0/2-0 47-1/2 23-1/2 5.9 3 3 CW40 CW60 / CW50 4-0/3-0 47-1/2 35-1/2 9.5 3 3 CW40 CW60 / CW50 4-0/3-2 47-1/2 37-1/2 10.2 3 3 CW40 CW60 / CW50 4-0/3-6 47-1/2 41-1/2 11.4 3 3 CW40 CW60 / CW50 4-0/3-10 47-1/2 45-1/2 12.6 3 3 CW40 CW60 / CW50 4-0/4-0 47-1/2 47-1/2 13.2 3 3 CW40 CW60 / CW50 4-0/4-4 47-1/2 51-1/2 14.4 5 3 CW40 CW60 / CW50 4-0/4-6 47-1/2 53-1/2 15.0 5 3 CW40 CW60 / CW50 4-0/5-0 47-1/2 59-1/2 16.8 5 3 CW40 CW60 / CW50 4-0/5-2 47-1/2 61-1/2 17.4 5 3 CW40 CW60 / CW50 4-0/5-6 47-1/2 65-1/2 18.6 5 3 CW40 CW60 / CW50 4-0/6-0 47-1/2 71-1/2 20.4 5 3 CW40 CW60 / CW50 4-6/1-2 53-1/2 13-1/2 3.3 2.5 3 CW40 CW60 / CW50 4-6/1-6 53-1/2 17-1/2 4.7 2.5 3 CW40 CW60 / CW50 4-6/2-0 53-1/2 23-1/2 6.7 3 3 CW40 CW60 / CW50 4-6/3-0 53-1/2 35-1/2 10.9 3 3 CW40 CW60 / CW50 4-6/3-2 53-1/2 37-1/2 11.6 3 3 CW40 CW60 / CW50 4-6/3-6 53-1/2 41-1/2 12.9 3 3 CW40 CW60 / CW50 4-6/3-10 53-1/2 45-1/2 14.3 5 3 CW40 CW60 / CW50 4-6/4-0 53-1/2 47-1/2 15.0 5 3 CW40 CW60 / CW50 4-6/4-4 53-1/2 51-1/2 16.4 5 5 CW40 CW60 / CW50 4-6/4-6 53-1/2 53-1/2 17.1 5 5 CW40 CW60 / CW50 4-6/5-0 53-1/2 59-1/2 19.1 5 5 CW40 CW60 / CW50 4-6/5-2 53-1/2 61-1/2 19.8 5 5 CW40 CW60 / CW50 4-6/5-6 53-1/2 65-1/2 21.2 5 5 CW40 CW60 / CW50 4-6/6-0 53-1/2 71-1/2 23.3 5 5 CW40 CW60 / CW50 5-0/1-2 59-1/2 13-1/2 3.7 2.5 3 CW40 CW60 / CW50 5-0/1-6 59-1/2 17-1/2 5.2 2.5 3 CW40 CW60 / CW50 5-0/2-0 59-1/2 23-1/2 7.5 3 3 CW40 CW60 / CW50 5-0/3-0 59-1/2 35-1/2 12.2 3 3 CW40 CW60 / CW50 5-0/3-2 59-1/2 37-1/2 13.0 3 3 CW40 CW60 / CW50 5-0/5-0 59-1/2 41-1/2 14.5 5 3 CW40 CW60 / CW50 5-0/3-10 59-1/2 45-1/2 16.0 5 3 CW40 CW60 / CW50 5-0/4-0 59-1/2 47-1/2 16.8 5 3 CW40 CW60 / CW50 5-0/4-4 59-1/2 51-1/2 18.4 5 5 CW40 CW60 / CW50 5-0/4-6 59-1/2 53-1/2 19.1 5 5 CW40 CW60 / CW50 5-0/5-0 59-1/2 59-1/2 21.4 5 5 CW40 CW60 / CW50 5-0/5-2 59-1/2 61-1/2 22.2 5 5 CW40 CW60 / CW50 5-0/5-6 59-1/2 65-1/2 23.8 5 5 CW40 CW60 / CW50 5-0/6-0 59-1/2 71-1/2 26.1 5 5 CW40 CW60 / CW50 3 of 4 (1) Maximum performance when glazed with the appropriate glass thickness. (2) econd value, where shown, is for single units with a nail frame. To convert areas to square meters (m²), multiply square feet by 0.0929. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-21

DEIGN DATA ingle Units INGLE FIXED UNIT Call ut Width (Inches) Frame Height (Inches) Visible Ft2 tandard Thickness (mm) Performance Class & Grade 1 Annealed Tempered tandard Upgrade 2 6-0/1-2 71-1/2 13-1/2 4.5 2.5 3 CW40 CW60 / CW50 6-0/1-6 71-1/2 17-1/2 6.4 3 3 CW40 CW60 / CW50 6-0/2-0 71-1/2 23-1/2 9.2 3 3 CW40 CW60 / CW50 6-0/3-0 71-1/2 35-1/2 14.8 5 3 CW40 CW60 / CW50 6-0/3-2 71-1/2 37-1/2 15.7 5 3 CW40 CW60 / CW50 6-0/5-0 71-1/2 41-1/2 17.6 5 3 CW40 CW60 / CW50 6-0/3-10 71-1/2 45-1/2 19.5 5 3 CW40 CW60 / CW50 6-0/4-0 71-1/2 47-1/2 20.4 5 3 CW40 CW60 / CW50 6-0/4-4 71-1/2 51-1/2 22.3 5 5 CW40 CW60 / CW50 6-0/4-6 71-1/2 53-1/2 23.3 5 5 CW40 CW60 / CW50 6-0/5-0 71-1/2 59-1/2 26.1 5 5 CW40 CW60 / CW50 6-0/5-2 71-1/2 61-1/2 27.0 5 5 CW40 CW60 / CW50 6-0/5-6 71-1/2 65-1/2 28.9 5 5 CW40 CW60 / CW50 6-0/6-0 71-1/2 71-1/2 31.7 5 5 CW40 CW60 / CW50 7-0/1-2 83-1/2 13-1/2 5.3 2.5 3 R40 / LC30 CW60 / LC30 7-0/1-6 83-1/2 17-1/2 7.5 3 3 R40 / LC30 CW60 / LC30 7-0/2-0 83-1/2 23-1/2 10.8 3 3 R40 / LC30 CW60 / LC30 7-0/3-0 83-1/2 35-1/2 17.4 5 3 R40 / LC30 CW60 / LC30 7-0/3-2 83-1/2 37-1/2 18.5 5 3 R40 / LC30 CW60 / LC30 7-0/5-0 83-1/2 41-1/2 20.8 5 3 R40 / LC30 CW60 / LC30 7-0/3-10 83-1/2 45-1/2 23.0 5 3 R40 / LC30 CW60 / LC30 7-0/4-0 83-1/2 47-1/2 24.1 5 3 R40 / LC30 CW60 / LC30 7-0/4-4 83-1/2 51-1/2 26.3 5 5 R40 / LC30 CW60 / LC30 7-0/4-6 83-1/2 53-1/2 27.4 5 5 R40 / LC30 CW60 / LC30 7-0/5-0 83-1/2 59-1/2 30.7 5 5 R40 / LC30 CW60 / LC30 7-0/5-2 83-1/2 61-1/2 31.8 5 5 R40 / LC30 CW60 / LC30 7-0/5-6 83-1/2 65-1/2 34.0 5 5 R40 / LC30 CW60 / LC30 8-0/1-2 96-1/2 13-1/2 6.1 3 3 R40 / LC30 CW60 / LC30 8-0/1-6 96-1/2 17-1/2 8.7 3 3 R40 / LC30 CW60 / LC30 8-0/2-0 96-1/2 23-1/2 12.6 3 3 R40 / LC30 CW60 / LC30 8-0/3-0 96-1/2 35-1/2 20.3 5 3 R40 / LC30 CW60 / LC30 8-0/3-2 96-1/2 37-1/2 21.6 5 3 R40 / LC30 CW60 / LC30 8-0/5-0 96-1/2 41-1/2 24.1 5 3 R40 / LC30 CW60 / LC30 8-0/3-10 96-1/2 45-1/2 26.7 5 3 R40 / LC30 CW60 / LC30 8-0/4-0 96-1/2 47-1/2 28.0 5 3 R40 / LC30 CW60 / LC30 8-0/4-4 96-1/2 51-1/2 30.6 5 5 R40 / LC30 CW60 / LC30 8-0/4-6 96-1/2 53-1/2 31.9 5 5 R40 / LC30 CW60 / LC30 8-0/5-0 96-1/2 59-1/2 35.7 5 5 R40 / LC30 CW60 / LC30 4 of 4 (1) Maximum performance when glazed with the appropriate glass thickness. (2) econd value, where shown, is for single units with a nail frame. To convert areas to square meters (m²), multiply square feet by 0.0929. Pella 2018 Architectural Design Manual Division 08 penings Windows and Doors www.pellaadm.com 350-FW-22