B. Shop Drawings: Show fabrication and installation details for roof accessories.

Similar documents
B. Coordinate dimensions with rough-in information or Shop Drawings of equipment to be supported.

SECTION TURBINE VENTILATORS

A. Access doors and frames are part of an access door and frame allowance.

SECTION ROOF SPECIALTIES

SECTION HVAC GRAVITY VENTILATORS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION 07530CP EPDM MEMBRANE ROOFING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION EXPANSION CONTROL

Specifications for FL-100 Soffit Panel

Roof Accessories. Division Roof Hatches Roof Safety Rails Safety Posts. Division Smoke Vents

Metal Roof Panels

SECTION METAL ROOF PANELS

Light-Metal Roof Edge, Raised

CS-100 Guide Specifications

SPECIFICATIONS: Architectural Aluminum Railings

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

SECTION SECTIONAL OVERHEAD DOORS

Section PANEL SIGNAGE

SECTION ALUMINUM STORM WINDOWS

Wall Louvers (10200)

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

SECTION EXTERIOR GRILLS AND SCREENS

SECTION DIRECTORIES

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION ACCORDION FOLDING PARTITIONS

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

Corium Brick Rainscreen System Specifications

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

Section SECTIONAL INSULATED STEEL DOORS

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

SECTION CHAIN LINK FENCES AND GATES

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

Series - 1

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

Roof Hatches Smoke Vents. Complementary B u i l d i n g Products

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

A. Product Data: For each type of deck, accessory, and product indicated.

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

SECTION ALUMINUM WINDOWS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

SECTION HANGERS AND SUPPORTS FOR PLUMBING

SECTION DECORATIVE METAL FENCES AND GATES

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

SECTION LOUVERS AND VENTS

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

On-Call General Contractor Specifications University of Maryland College Park June 2013

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

B. Provide fire-rated access doors where indicated or scheduled.

ROOF ACCESS HATCHES LADDERS SMOKE VENTS FLOOR ACCESS SAFETY PRODUCTS. The Worldwide Source for Speciality Access Products

2049 S.W. Poma Drive Palm City, Fl Office (772) CGC Fax (772)

JL Fire Vents - Guide Submittal / Specifications


A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Aluminum-Framed Entrances and Storefronts

SWING DOOR SPECIFICATION

PIPE AND TUBE RAILINGS

PPG Guide Specification

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Daytona Beach Pier Building Renovation Jun 2010

Guide Specification SDP 200

Prestige Series Guide Specifications

Attachment A-Flagpole(s) Specifications

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION ALUMINUM RAILINGS

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Kodiak AWT Hangar, Kodiak Airport Alaska, Siding Specifications

SECTION METAL FABRICATIONS

TMS 114 XT TECHNICAL MANUAL

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Transcription:

SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Roof curbs. 2. Equipment supports. 3. Roof hatches. 4. Dropout-type heat and smoke vents. 5. Hatch-type heat and smoke vents. 6. Roof walkways. 1.2 SUBMITTALS A. Product Data: For each type of roof accessory indicated. B. Shop Drawings: Show fabrication and installation details for roof accessories. C. Samples: For each type of exposed factory-applied color finish required and for each type of roof accessory indicated, prepared on Samples of size to adequately show color. 1.3 QUALITY ASSURANCE A. Sheet Metal Standard: Comply with SMACNA's "Architectural Sheet Metal Manual" details for fabrication of units, including flanges and cap flashing to coordinate with type of roofing indicated. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, manufacturers listed in other Part 2 articles. 2.2 METAL MATERIALS A. Galvanized Steel Sheet: ASTM A 653/A 653M, G90 (Z275) coated and mill phosphatized for field painting. B. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, AZ50 (AZM150) coated. ROOF ACCESSORIES 077200-1

C. Pre-painted, Metallic-Coated Steel Sheet: Steel sheet metallic coated by hot-dip process and pre-painted by coil-coating process to comply with ASTM A 755/A 755M. 1. Galvanized Steel Sheet: ASTM A 653/A 653M, G90 (Z275) coated. 2. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, Class AZ50 (Class AZM150) coated. 3. Exposed Finishes: Manufacturer's standard 2-coat, thermocured system consisting of specially formulated inhibitive primer and fluoropolymer color topcoat containing not less than 70 percent polyvinylidene fluoride resin by weight. D. Aluminum Sheet: ASTM B 209 (ASTM B 209M), alloy and temper recommended by manufacturer for type of use and mill finish. Coil-coat finish as follows: 1. Factory-Prime Coating: Where painting after installation is indicated, provide pretreatment and white or light-colored, factory-applied, baked-on epoxy primer coat; with a minimum dry film thickness of 0.2 mil (0.005 mm). 2. Anodic Finish: Architectural Class II, complying with AAMA 611. a. Color: As selected by Architect/Engineer from manufacturer's full range. 3. Baked-Enamel Finish: Organic Coating: Thermosetting, modified-acrylic enamel primer/topcoat system complying with AAMA 2603 except with a minimum dry film thickness of 1.5 mils (0.04 mm), medium gloss. a. Color and Gloss: As selected by Architect/Engineer from manufacturer's full range. 4. High-Performance Organic Finish: Manufacturer's standard 2-coat, thermocured system consisting of specially formulated inhibitive primer and fluoropolymer color topcoat containing not less than 70 percent polyvinylidene fluoride resin by weight. a. Color and Gloss: As selected by Architect/Engineer from manufacturer's full range. 5. Powder-Coat Finish: Immediately after cleaning and pretreating, electrostatically apply manufacturer's standard baked-polymer thermosetting powder finish. a. Color and Gloss: As selected by Architect/Engineer from manufacturer's full range. E. Stainless-Steel Shapes or Sheet: ASTM A 240/A 240M or ASTM A 666, Type 304 or Type 316, No. 2D finish. 2.3 MISCELLANEOUS MATERIALS A. Acrylic Glazing: ASTM D 4802, thermoformable, monolithic sheet, category as standard with manufacturer, Type UVA (formulated with UV absorber), Finish 1 (smooth or polished). ROOF ACCESSORIES 077200-2

B. Polycarbonate Glazing: Thermoformable, monolithic polycarbonate sheets manufactured by extrusion process, burglar-resistance rated per UL 972 with an average impact strength of 12 to 16 ft-lbf/in. (640 to 854 J/m) of width when tested according to ASTM D 256, Method A (Izod). C. Security Grilles: 3/4-inch- (19-mm-) diameter, ASTM A 1011/A 1011M steel bars spaced [6 inches (150 mm) o.c. in 1 direction and 12 inches (300 mm) o.c. in the other; factory primed. 2.4 ROOF CURBS A. Roof Curbs: Provide metal roof curbs, internally reinforced and capable of supporting superimposed live and dead loads, including equipment loads and other construction to be supported on roof curbs. Fabricate with welded or sealed mechanical corner joints, with integral metal cant, or stepped integral metal cant raised the thickness of roof insulation and integral formed mounting flange at perimeter bottom. Coordinate dimensions with rough-in information or Shop Drawings of equipment to be supported. 1. Manufacturers, as indicated in Drawings or approved equal by: a. Colony Custom Curbs. b. LM Curbs. c. Loren Cook Company. d. Metallic Products Corporation. e. Pate Company (The). f. Roof Products & Systems Corporation. g. Roof Products, Inc. h. Thaler Metal Industries Ltd. i. ThyCurb; Div. of Thybar Corporation. j. Uni-Curb, Inc. k. Vent Products Company, Inc. 2. Load Requirements: As required by local codes, and UBC-1997. 3. Material: Galvanized, or Aluminum-zinc alloy-coated steel sheet, 0.079 inch (2.0 mm) thick. 4. Material: Aluminum sheet, 0.090 inch (2.28 mm) thick. 5. Material: Stainless-steel sheet, 0.078 inch (1.98 mm) thick. a. Finish: Prime painted, Baked enamel, High-performance organic coating, or Powder coat. b. Finish: As selected by Architect/Engineer from manufacturer's full range. 6. Liner: Same material as curb, of manufacturer's standard thickness and finish. 7. Factory install wood nailers at tops of curbs. 8. On ribbed or fluted metal roofs, form flange at perimeter bottom to conform to roof profile. 9. Factory insulate curbs with 1-1/2-inch- (38-mm-) thick, glass-fiber board insulation. 10. Curb height may be determined by adding thickness of roof insulation and minimum base flashing height recommended by roofing membrane manufacturer. Fabricate units to minimum height of 12 inches (300 mm), unless otherwise indicated. 11. Sloping Roofs: Where slope of roof deck exceeds 1:48, fabricate curb units with water diverter or cricket and with height tapered to match slope to level tops of units. ROOF ACCESSORIES 077200-3

2.5 EQUIPMENT SUPPORTS A. Equipment Supports: Provide metal equipment supports, internally reinforced and capable of supporting superimposed live and dead loads, including equipment loads and other construction to be supported. Fabricate with welded or sealed mechanical corner joints, with integral metal cant, or stepped integral metal cant raised the thickness of roof insulation and integral formed mounting flange at perimeter bottom. Coordinate dimensions with rough-in information or Shop Drawings of equipment to be supported. 1. Manufacturers, as indicated in Drawings or approved equal by: a. Colony Custom Curbs. b. LM Curbs. c. Loren Cook Company. d. Metallic Products Corporation. e. Pate Company (The). f. Roof Products & Systems Corporation. g. Roof Products, Inc. h. Thaler Metal Industries Ltd. i. ThyCurb; Div. of Thybar Corporation. j. Uni-Curb, Inc. k. Vent Products Company, Inc. 2. Load Requirements: As per local codes, and UBC-1997. 3. Material: Galvanized, or Aluminum-zinc alloy-coated steel sheet, 0.079 inch (2.0 mm) thick. 4. Material: Aluminum sheet, 0.090 inch (2.28 mm) thick. 5. Material: Stainless-steel sheet, 0.078 inch (1.98 mm) thick. a. Finish: Prime painted, Baked enamel, High-performance organic coating, or Powder coat. b. Finish: As selected by Architect/Engineer from manufacturer's full range. 6. Factory-install continuous wood nailers 3-1/2 inches (90 mm), or 5-1/2 inches (140 mm) wide at tops of equipment supports. 7. Metal Counterflashing: Manufacturer's standard removable counterflashing, fabricated of same metal and finish as equipment support. 8. On ribbed or fluted metal roofs, form flange at perimeter bottom to conform to roof profile. 9. Fabricate units to minimum height of 12 inches (300 mm), unless otherwise indicated. 10. Sloping Roofs: Where slope of roof deck exceeds 1:48, fabricate curb units with water diverter or cricket and with height tapered to match slope to level tops of units. 2.6 ROOF HATCHES A. Roof Hatches: Fabricate roof hatches with insulated double-wall lids and insulated double-wall curb frame with integral deck mounting flange and lid frame counterflashing. Fabricate with welded or mechanically fastened and sealed corner joints. Provide continuous weather-tight perimeter gasketing and equip with corrosion-resistant or hot-dip galvanized hardware. ROOF ACCESSORIES 077200-4

1. Manufacturers, as indicated in Drawings or approved equal by: a. Bilco Company (The). 2. Loads: Fabricate roof hatches to withstand 40-lbf/sq. ft. (1.9-kPa) external and 20-lbf/sq. ft. (0.95-kPa) internal loads. 3. Type and Size: Single-leaf lid, 30 by 54 inches (750 by 1370 mm). 4. Curb and Lid Material: Galvanized, or Aluminum-zinc alloy-coated steel sheet, 0.079 inch (2.0 mm) thick. 5. Curb and Lid Material: Aluminum sheet, 0.090 inch (2.28 mm) thick. 6. Curb and Lid Material: Stainless-steel sheet, 0.078 inch (1.98 mm) thick. a. Finish: Prime painted, Baked enamel, High-performance organic coating, or Powder coat. As selected by Architect/Engineer from manufacturer's full range. b. Finish: Mill, Clear anodic, or Color anodic. As selected by Architect/Engineer from manufacturer's full range. 7. Insulation: Glass-fiber or Polyisocyanurate board. 8. Interior Lid Liner: Manufacturer's standard metal liner of same material and finish as outer metal lid. 9. Exterior Curb Liner: Manufacturer's standard metal liner of same material and finish as metal curb. 10. On ribbed or fluted metal roofs, form flange at perimeter bottom to conform to roof profile. 11. Fabricate units to minimum height of 12 inches (300 mm), unless otherwise indicated. 12. Sloping Roofs: Where slope or roof deck exceeds 1:48, fabricate hatch curbs with height tapered to match slope to level tops of units. 13. Hardware: Galvanized steel, or Stainless-steel spring latch with turn handles, butt- or pintle-type hinge system, and padlock hasps inside and outside. a. Provide 2-point latch on covers larger than 84 inches (2130 mm). b. Provide remote-control operation. 14. Ladder Safety Post: Manufacturer's standard ladder safety post. Post to lock in place on full extension. Provide release mechanism to return post to closed position. 15. Safety Railing System: Manufacturer's standard complete system including rails, clamps, fasteners, safety barrier at railing opening, and all accessories required for a complete installation. 2.7 HEAT AND SMOKE VENTS A. Dropout-Type Heat and Smoke Vents: Manufacturer's standard gravity-operated, automatic smoke and heat vents with integral double-wall insulated curbs and frame with welded or sealed mechanical corner joints, integral condensation gutter, cap flashing, and heat-sensitive dome glazing that will deform and drop out of vent opening within 5 minutes of exposure to a simulated fire represented by a time-temperature gradient that reaches an air temperature of 500 deg F (260 deg C) within 5 minutes. 1. Manufacturers, as indicated in Drawings or approved equal by: ROOF ACCESSORIES 077200-5

a. C/S Group. b. Custom Curb, Inc. c. Dur-Red Products. d. Hi Pro International, Inc. e. Milcor Inc.; a Gibraltar Company. f. Naturalite Skylight Systems. g. O'Keeffe's Inc. h. Pate Company (The). i. Plasteco, Inc. j. Wasco Products, Inc. 2. Loads: Fabricate heat and smoke vents to withstand a minimum 40-lbf/sq. ft. (1.9-kPa) external live load and 30-lbf/sq. ft. (1.4-kPa) uplift. 3. Regulatory Requirements: Comply with UL 793 and NFPA 204. 4. Heat and Smoke Vent Compliance: Provide units that have been tested and UL listed, FMG approved. 5. Integral Curb and Framing Material: Galvanized, or Aluminum-zinc alloy-coated steel sheet, 0.079 inch (2.0 mm) thick. 6. Integral Curb and Framing Material: Aluminum sheet, 0.090 inch (2.28 mm) thick. 7. Integral Curb and Framing Material: Stainless-steel sheet, 0.078 inch (1.98 mm) thick. a. Finish: Prime painted, Baked enamel, High-performance organic coating, Powder coat. As selected by Architect/Engineer from manufacturer's full range. b. Finish: Mill, Clear anodic, Color anodic. As selected by Architect/Engineer from manufacturer's full range. 8. Insulation: Glass-fiber, or Polyisocyanurate board. 9. Exterior Curb Liner: Manufacturer's standard metal liner of same material and finish as metal curb. 10. Fabricate integral curbs to minimum height of 12 inches (300 mm), unless otherwise indicated. 11. Sloping Roofs: Where slope of roof deck exceeds 1:48, fabricate curbs with height tapered to match slope to level tops of units. B. Hatch-Type Heat and Smoke Vents: Manufacturer's standard single-leaf, hatch-type heat and smoke vents with integral double-wall insulated curbs and frame, with welded or sealed mechanical corner joints, integral condensation gutter, and cap flashing. Fabricate with insulated double-wall lid, continuous weather-tight perimeter lid gaskets, and equip with automatic self-lifting mechanisms, UL-listed fusible links rated at 165 deg F (74 deg C), firesuppression system, or smoke-detection system, and corrosion-resistant or hot-dip galvanized hardware including hinges, hold-open devices, and independent manual-release devices for inside and outside operation of lids. 1. Manufacturers: a. Babcock-Davis; a Cierra Products Inc. Company. b. Bilco Company (The). 2. Loads: Fabricate heat and smoke vent to withstand a minimum 40-lbf/sq. ft. (1.9-kPa) external live load and 30-lbf/sq. ft. (1.4-kPa) uplift. ROOF ACCESSORIES 077200-6

a. When release is actuated, lid shall open against 10-lbf/sq. ft. (0.5-kPa) wind load and lock in position. 3. Regulatory Requirements: UL 793 and NFPA 204. 4. Heat and Smoke Vent Compliance: Provide units that have been tested and UL listed, FMG approved. 5. Fire Resistance of Lids: UL Class A rating. 6. Integral Curb, Framing, and Lid Material: Galvanized, Aluminum-zinc alloy-coated steel sheet, 0.079 inch (2.0 mm) thick. 7. Integral Curb, Framing, and Lid Material: Aluminum sheet, 0.090 inch (2.28 mm) thick. 8. Integral Curb, Framing, and Lid Material: Stainless-steel sheet, 0.078 inch (1.98 mm) thick. a. Finish: Prime painted, Baked enamel, High-performance organic coating, Powder coat. As selected by Architect/Engineer from manufacturer's full range. b. Finish: Mill, Clear anodic, Color anodic. As selected by Architect/Engineer from manufacturer's full range. 9. Insulation: Glass-fiber, or Polyisocyanurate board. 10. Fabricate integral curbs to minimum height of 12 inches (300 mm), unless otherwise indicated. 11. Sloping Roofs: Where slope of roof deck exceeds 1:48, fabricate curbs with height tapered to match slope to level tops of units. 2.8 ROOF WALKWAYS AT ELEVATOR MECHANICAL ROOM LADDERS A. Roof Walkway: Multiple C-shaped-channel formed-metal planks, as follows, with upper surface punched in serrated diamond or rectangular shapes to produce raised slip-resistant surface and drainage holes. Provide support framing, brackets, connectors, nosings, and other accessories and components needed for complete installation. Include step units for changes in elevation. 1. Manufacturers: a. GS Metals Corp. b. Unistrut Corporation. 2. Plank Width: 24 inches (610 mm), or as indicated. 3. Walkway Width: As indicated. 4. Channel Depth: 3 inches (76 mm), or as indicated. 5. Metal Material: 0.108-inch- (2.8-mm-) thick, hot-dip galvanized steel sheet, or 0.078- inch- (1.98-mm-) thick, stainless-steel sheet, or 0.100-inch- (2.5-mm-) thick, millfinished aluminum sheet. 6. Provide isolation pads attached to supports so supports are completely isolated from roof membrane surface. ROOF ACCESSORIES 077200-7

PART 3 - EXECUTION 3.1 INSTALLATION A. General: Install roof accessories according to manufacturer's written instructions. Anchor roof accessories securely in place and capable of resisting forces specified. Use fasteners, separators, sealants, and other miscellaneous items as required for completing roof accessory installation. Install roof accessories to resist exposure to weather without failing, rattling, leaking, and fastener disengagement. B. Install roof accessories to fit substrates and to result in watertight performance. C. Metal Protection: Where dissimilar metals will contact each other or corrosive substrates, protect against galvanic action by painting contact surfaces with bituminous coating or by other permanent separation as recommended by manufacturer. 1. Coat concealed side of uncoated aluminum, or stainless-steel roof accessories with bituminous coating where in contact with wood, ferrous metal, or cementitious construction. 2. Underlayment: Where installing exposed-to-view components of roof accessories directly on cementitious or wood substrates, install a course of felt underlayment and cover with a slip sheet, or install a course of polyethylene underlayment. 3. Bed flanges in thick coat of asphalt roofing cement where required by roof accessory manufacturers for waterproof performance. D. Install roof accessories level, plumb, true to line and elevation, and without warping, jogs in alignment, excessive oil canning, buckling, or tool marks. E. Seal joints with elastomeric or butyl sealant as required by manufacturer of roof accessories. END OF SECTION 077200 ROOF ACCESSORIES 077200-8