MDC Ceramic Eggshell Ceramic Coating for Walls

Similar documents
MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

Refer to Substrates & Surface Preparation.

Copyright 2018, The Sherwin-Williams Company ISSUED MAY CARB FLUID APPLIED FLOORING FOR CONCRETE THE SHERWIN-WILLIAMS COMPANY

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Aliphatic Acrylic-Polyester Polyurethane

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Refer to Substrates & Surface Preparation.

Technical Data Sheet

SIDER-POOL. Product Data. Features and Uses

Measured in accordance with ASTM D 2697.

Section COATING RESTORATION

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Rust-Oleum Industrial Brands Specification

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

DAP ALEX FAST DRY Acrylic Latex Caulk Plus Silicone

Associated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS

CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Ash Brook Golf Course Scotch Plains, New Jersey

TECHNICAL DATA SHEET

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

Lluminations complies with all federal air pollution regulations for volatile organic compounds.

Sample Specification

REFLECTIT. Reflectit Application Instructions Spray and Roller DS % Acrylic Coating Providing a Pearlescent Appearance

BEP Blue Barrier Installation and Application Guide

Corlar LV PR 178 Series Epoxy Primer

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

BEP Blue Barrier Installation and Application Guide

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SAMPLE SPECIFICATION

Corlar 2.8 HG High Solids Epoxy

TECHNICAL DATA SHEET

Signature Seal 100 Medium-to-High Sheen Sealer VOC Characteristics and Applications

F.S.P.M.A. PAINT SPECIFICATION DIVISION 9 FINISHES SECTION INTERIOR MP-47.2 MOLD AND MILDEW PROOF ACRYLIC PAINT

SECTION CONCRETE AND MASONRY COATINGS

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

SILASEC DESCRIPTION FEATURES AND BENEFITS SURFACE PREPARATION

TECHNICAL DATA SHEET

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

3910 E. McKinney Denton, TX P.O. Box Dallas, TX EZ WALL CONCENTRATE, INC

Technical Bulletin Boston Street, Suite 200, Baltimore, Maryland Phone: or

DULUX WEATHERGUARD FINE TEXTURED

THE BRITE THING TO DO

Metallic Color Coat. Factory-mixed, 100% acrylic polymer coating

CROMAX PRO WB9908 SUPER JET BLACK BASECOAT

Approx. 12 m² per litre depending on surface porosity, profile. Application methods

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

3M Fast Tack Water Based Adhesive 1000NF

LIQUID WATERPROOFING Technical Data

Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

FUSION X Wall Base Adhesive

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

SECONDARY CONTAINMENT COATING SPECIFICATION

TOPCOAT Restoration Specifications Structural Concrete

Application Instructions for Keystone Kool Deck on Existing Concrete

White, a range of ready-mixed colours, and colours from the Dulux Colour System

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

Ready-to-use structural plaster for interior use

YEARS WATER PROOFING AND PERFORMANCE WARRANTY*

Coronado Industrial Coatings Old County Road Edgewater, Florida FAX Line. Min Recoat:

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

There are many surface contaminants that can interfere with coating adhesion. The following are the most common:

the SureCoat Roof System.

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

HVAC Antimicrobial Protected Coatings

Data Sheet Eco-Smart Epoxy Series WS 101

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

BR 252 Water Based Bonding Primer

Soft Grip. WATERBASED Anti-Slip Coatings

Fiber Reinforced Tile and Stone Mortar

Paint to Protect TM International Fireproof Technology, Inc Von Karman Ave. Irvine, CA 92614

VB fluid-applied air & water-resistive barrier and water vapor barrier

SURFACE PREPARATION INSTRUCTIONS: CONCRETE

A. Submit product data sheets and literature verifying physical properties of materials.

VB fluid-applied air & water-resistive barrier and water vapor barrier

Commercial Resilient Sheet Flooring

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

POWERBASE ICF / SIDER PROOF FF-PR

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

MDC Paints & Finishes LEED COMPLIANCE

Senerflex Finishes. Product Bulletin

RUST TRAP TM TECHNICAL DATA SHEET

Education Facility Guide Specification

Blue Barrier Liquid Wrap 2300

Color Stain 5100 System APPLICATION INSTRUCTIONS

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

DOWSIL ALLGUARD Silicone Elastomeric Coating

TOPCOAT System Specifications Corrugated Transite Panels

Application. Fuselage Fuselage Fuselage. Decoration Decoration

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

SU2845 MEXICAN TILE SEALER HIGH GLOSS FINISH

Product Information. DiamondCoat Polyurethane Concrete Floor Finish Clear, high build, high abrasion resistant, decorative concrete floor coating

FLOORING INSTALLATION SYSTEMS. Product Catalog

Transcription:

Distributed By: MDC Wallcoverings 400 High Grove Blvd. Glendale Heights, IL 60139 Phone: 847-437-4000 Fax: 847-437-4017 Toll Free: 800-621-4006 www.mdcwallfinishes.com Product Description MDC Ceramic is a subtle durable finish in a water-based, ceramic enhanced formula. It contains ceramic micro-spheres which are the newest innovation in paint technology. It is designed to be used in virtually any commercial setting that paint is used including corporate, education, healthcare, hospitality, as well as retail spaces and other public areas that must be cleaned often. Environmentally safe, MDC Ceramic is fully compliant with all Volatile Organic Compounds (V.O.C.) regulations. Water-based Formula Ceramic Enhanced Budget Sensitive Custom Color Capabilities Convenient Spray Application Quantities and Colors Container Sizes: 1 gallon and 5 gallon pails. Colors: Range of standard colors; custom colors available. Environmentally friendly, low-odor application Micro-spheres add superior durability and scrubability. Offers a decorative alternative to paint for pennies more Adapts to virtually any color scheme Quick and easy installation using standard equipment Microban Product Protection MDC Ceramic contains Microban antimicrobial product protection. This unique additive will inhibit the growth of stain and odor causing bacteria, mold, mildew, and other fungal growth on the dried paint film. Microban protection provides an added level of protection between cleanings, but does not take the place of normal cleaning and disinfecting procedures and will not protect users or others against food-borne illness. Microban additives are E.P.A. registered for use in paint. For more information on Microban, please visit www.microban.com. Technical Information and Test Results Solids by Volume: 47-48% Solids by Weight: 33-34% Max. VOC: less than 50 g/l Scrub Resistance: ASTM D-2486: More than 3000 scrub cycles Stain Resistance: Washability: ASTM D-1308: Excellent ASTM D-3450: Excellent Finish: Eggshell (10-15% gloss @ 60 F) Coverage Rate: Approximately 350 sq. ft. per gallon at 4 mils wet on smooth surface Application Temperature: 50-90 F, RH < 50% Dry Time: To touch 30minutes, 4 hours to re-coat Shelf Life: 12 months Room Temperature Touch-up: Excellent Burnish, Dry: (Sheen 85 Difference) 1.4 Avg. of 13 (National Avg. = 3.3) (lower number = better rating) 1

Substrate New Gypsum Board Cured New Plaster Painted Surfaces (Non-Gloss) Painted Surfaces (Gloss/Semi-Gloss) Ceramic Tile/Block Plastic Laminate Fiberglass Interior Metals Cured Concrete/Masonry Concrete Block Wood Surface Preparation/Primers Recommended Primer (To extend coverage and provide uniform sealed surface) (To extend coverage and provide uniform sealed surface) High quality, commercial grade 100% acrylic block filler Spot prime knots and prime surface with 1 coat of a high quality commercial grade suitable stain blocking primer Surface Preparation All surfaces to receive the finish should be prepared as if to receive a typical paint application; free from wax, oil, grease and water soluble materials. All cracks, holes or voids should be filled with an appropriate patching compound, allowed to cure and spot primed. All markings should be removed and/or sealed with a stain blocking primer to prevent bleed through. Mildew must be neutralized and a stain blocking primer should be applied to the affected area. Glossy areas should be dulled. New Drywall: Repair holes/cracks by patching with joint compound and sanding smooth. Wipe with a clean damp rag to remove all sanding dust and construction debris. Masonry/Concrete: Must cure for 30 days before coating. Remove curing and form-release agents. Wood: Sand exposed areas to a fresh surface. Fill nail holes and other surface damage with wood filler or putty. Sand smooth. Wipe with a clean damp rag to remove all sanding dust and construction debris. Plaster: Allow new plaster to cure a minimum of 28 days prior to coating. Hard Shiny Surfaces: Clean thoroughly to remove wax, grease and/or oil residue. Scuff-sand with fine silicon carbide sand paper. Wipe with a clean damp rag to remove all sanding dust and construction debris. Previously Painted Surfaces: Remove all loose paint, dirt, chalk and damaged substrate. Clean thoroughly to remove wax, grease and/or oil residue. Scuff-sand glossy surfaces. Wipe with a clean damp rag to remove all sanding dust and construction debris. Stains from water, smoke, grease, ink, etc. must be sealed with a suitable stain-blocking primer. Mildew: Mildew must be neutralized and removed before coating. Scrub affected areas with a 3:1 solution of warm water to household bleach. Rinse thoroughly with clean water and allow surface to dry completely before coating. Spot prime area with a stain blocking primer. Wear protective eyewear and waterproof gloves. Quickly wash skin that comes into contact with solution. Do not add ammonia or detergents to bleach/water solution. Applicators should carefully inspect the wall surface prior to beginning an application and be sure to prepare a test area for approval prior to proceeding. 2

Project Conditions and Preparation Application Equipment HVLP Sprayer: Commercial grade 4 stage HVLP equipment equivalent to a CapSpray 9100 with a #3 nozzle or a Graco 4900 with a #3 nozzle OR EQUIVALENT Conventional Sprayer: BINKS 2001-63 PB External Mix Air Cap, 66 SS Fluid Nozzle and 565 Needle, 2 Gallon Pressure Pot OR EQUIVALENT Airless Sprayer: Commercial grade sprayer equivalent to a Graco 395 or larger with a minimum tip size of.015 -.017 and minimum pressure of 2000 psi. Roller: 1/4-3/8 inch nap synthetic roller Brush: Synthetic fiber brush CAUTION! When spraying, wear goggles and a high-efficiency particulate respirator. Before spraying, caution-off the immediate application area to prevent others from coming into contact with spray mist. Project Conditions Apply MDC Ceramic only when surface and ambient air temperatures are 50 F - 90 F and relative humidity is less than 50% for 48 hours before, during and after the coating application. Substrate should be dry and free of moisture. Application area should be free from airborne containments prior to and during the coating application, and until the coating has fully cured. Coatings should be applied under adequate lighting. Do not apply in direct sunlight. If spraying in an enclosed area, mist ventilation is important. Use portable industrial air filtration units with disposable filters. Ensure adequate supplies of replacement filters are available. Good lighting conditions and a good system for ventilating spray mist - visibility to the wall surface while spraying is critical to achieving best results. Field Mock Ups Prepare Field Mock Up sample for Architect s, Designer s and/or Owner s review for each color and finish specified and for each substrate using actual substrate material. Correct areas not accepted; modify methods of application to comply with specified requirements. Do not proceed with work until field samples have been accepted. Product Preparation Mixing Material will settle during shipping and storage. Mix material thoroughly! Check bottom of pail to ensure thorough mixing with no fall-out. Box all containers of same color. Insufficient mixing may result in unacceptable color variation. Thinning For spraying, it may be desirable to thin product with up to four ounces of water per gallon to achieve appropriate consistency for atomization. o o DO NOT LET PRODUCT FREEZE! 3

APPLICATION Apply MDC Ceramic over a properly primed surface in a continuous, uniform, pin-hole free film at a minimum of 4 mils wet. The approximate coverage rate is 350 sq. ft. per gallon on smooth surfaces. Good lighting and visibility are essential while spraying. Take caution not to apply too heavily in a single pass material will sag. Position the gun approximately 12 inches from the surface being sprayed. Trigger the gun just before spraying on wall. While triggered, the gun should remain fully triggered and moving continuously in a vertical motion. Apply MDC Ceramic in a continuous vertical motion with a 50% overlap of the previous spray stroke. Overlapping by less than 50% will result in striping, and more than a 50% overlap will apply the material too heavily resulting in sags. When the end of the surface is reached, release the trigger, shutting off the material flow, but continue with the spray stroke for a few inches until the motion is reversed for the return stroke. Wait until MDC Ceramic is dry to touch approximately 60 minutes in good drying conditions before applying optional PearlProtector for added durability. When rolling, be sure to do a mock-up for approval before proceeding as slight variation from sprayed sample may occur. Cleaning Instructions Allow product to cure for at least seven days following application (allow 28 days on hard, nonabsorbent substrates) before applying cleaning chemicals. Most common stains can be easily removed using a sponge, rag or nylon bristle brush with water and mild soap or a general purpose cleaner. Before using a new cleaner for the first time, test its effect on the finish by applying in an inconspicuous area. Care should be taken not to rub the surface too aggressively to prevent burnishing. Safety Information Some persons may experience an allergic reaction to paint products if exposed to spray mist. Because spray application of this finish may create a fine mist of product in the immediate application area, a high-efficiency particulate respirator and protective glasses or goggles must be worn by the applicator. The immediate application area should be cautioned-off to prevent persons without safety equipment from coming into contact with mist. Ensure good ventilation. Review product MSDS sheets prior to application. First Aid Ingestion Induce vomiting, consult a physician. Skin Contact Wash with soap and water. Eye Contact Immediately flush eyes for 15 minutes occasionally lifting eyelids. If contact lenses are worn, remove lenses and continue rinsing. Dispose of contaminated lenses. Inhalation Move to fresh air. Obtain medical attention if necessary. Refer to product MSDS. In case of emergency, MSDS information may be obtained by calling 800-535-5053. 4

Five Year Limited Warranty Master Coating Technologies warrants the MDC Paint components of this finish system against manufacturing defect for a period of five years from the date of application when applied to a wall surface according to manufacturer s printed instructions. Manufacturing defect is defined to be a failure of the coating system to adhere to a wall surface when applied according to manufacturer s printed instructions, and does not include subsequent failure or damage caused by exogenous factors such as substrate failure or defect, sharp objects, persons, or acts of God. In the event of a failure resulting from the manufacturing defect, the product will be replaced. Master Coating Technologies shall have no obligation to or otherwise participate in labor or other costs associated with replacing the product. This warranty supersedes all previous warranties. The fact and figures represented in the specification manual are accurate to the best of our knowledge, and are the results of testing in our laboratory. We do not express, warrant or guarantee the accuracy, completeness, or reliability of same. Since constant improvements are ongoing, future technical data may vary somewhat from what was available when this bulletin was printed 5