FIRESTOPPING. The Hidden Solution that Compartmentalizes. Vic Wootton A/T Firestop and Fireproofing Solutions

Similar documents
Fire Protection Product Applications by Contractor Trades Through Penetrations & Joints

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

FIRESTOP SYSTEMS NOTES: Tony Crimi, P.Eng. A.C. Consulting Solutions Inc. Canadian Code Requirements

FIRESTOPPING Products for Life Safety and Code Compliance

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

Firestop Systems. Superior Firestop Solutions

Protecting Penetrations in Fire Rated Construction

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

DECEMBER Phone: Fax:

FIRESTOP SUBMITTAL PACKAGE

Pre & Post Occupancy Fire Barrier Management

HILTI CP 606 Flexible Firestop Sealant

Common Firestop Code Violations

Fire Protection Products

Hong Kong Industrial Safety Association

Unique Fire Stop Online Certification Test

3M CS-195+ Composite Sheet Product Description

PASSIVE FIRE PROTECTION PRODUCTS

3M Fire Protection Products. Confidence. Even Under Fire. Principal Products Ltd I Ph: I

CANADA SPECIFIC FIRESTOPPING REQUIREMENTS

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

Fire Barrier Duct Wrap 615+

Technical Data Sheet. Hilti Firestop cable collar CFS-CC. European technical approval ETA N o 13 / Issue 10 / 2013

HILTI CP 657 Firestop Brick

CERTIFICATE OF APPROVAL No CF 5363 NULLIFIRE LIMITED

UNIFIED FACILITIES GUIDE SPECIFICATIONS

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems

FIREPRO FIRESTOP PIPE COLLARS. Firestop solution for plastic pipework penetrations

FIRE-HALT SEALANT/SETTING COMPOUND

METACAULK PRODUCT CATALOG

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

HILTI CP 601S Elastomeric Firestop Sealant

SECTION HVAC INSULATION

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

A. Source Limitations: Obtain each type of building insulation through one source.

E. Manufacturers Standardization Society of the Valve and Fittings Industry:

HILTI CP 643N Firestop collar

CERTIFICATE OF APPROVAL No CF 816 BIP GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

International Fireproof Technology Inc.

UL Catalogue I en. Innovative Fire Protection Systems

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

upvc PIPE FIRE COLLARS HISTORY

DECLARATION OF PERFORMANCE

European Technical Assessment. ETA-11/0372 of Member of. General part

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

European Technical Assessment. ETA-12/0101 of Member of. General part

Marine Fire Wrap General Installation Instructions Cable Penetrations through A0-A60 and B0-B30 Bulkheads and Decks

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

HILTI CP 617 Intumescent acoustic putty pad

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

Installation in ceilings

AIPHONE Installation Specifications. Addendum I. December 12, 2014

SECTION Domestic Water Piping. A. American National Standards Institute (ANSI)/American Water Works Association (AWWA)

University of Delaware

CHECKLIST Inspecting a Garage

European Technical Assessment. ETA-16/0320 of Member of. General part

SECTION F -- FIRE STOPPING

The M ark o f Q uality C ast in Iron. BR-CISPI (515)

DETAILS GUIDE STRATASHIELD STANDARD FLOORING TABLE OF CONTENTS

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

Firestopping Submittal Package

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Protecting penetrations: Tips to maintain your fire and smoke barriers

FIRESTOP SUBMITTAL PACKAGE

WATERPROOFING CONSTRUCTION JOINTS

Pyroscat Duct Wrap XL

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

Nu-Wool U382 2 Hour Firewall Guide Please note that this firewall can only be installed by approved Nu-Wool U382 installers

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS FOR JOINTS AND PENETRATIONS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Installation instructions

Property of Cooks Plumbing Supplies

Submittal for Aquatherm Piping System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Cavity ShAftwall System

I-STUD Shaftwall System

FireMaster FastWrap XL

Kent, DA1 4FT. appended hereto:

2005 Seismic Bracing System. Kindorf Modular Metal Framing

Duct Wrap 2x2 Duct Wrap 2x2+ Commercial Kitchen Grease Duct

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct

walraven.com BIS Pacifyre AWM III Fire Collar BIS Pacifyre IWM III Fire Strip

Document Title: Doc No: FRM B4-59 Rev No: Page: Of: Thermal Insulation Program Certification Report

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

Transcription:

FIRESTOPPING The Hidden Solution that Compartmentalizes Vic Wootton A/T Firestop and Fireproofing Solutions

Firestop What is Firestop Where Required Why Important Who Installs Type of Products How to Install 2

A/T Firestop and Fireproofing SOLUTIONS Inc. PERSONAL PROFILE: Victor Wootton 5 years with A/D Fire Protection Systems Manufacture rep and Product Manager 10 years managing A/T Firestop

A/T Firestop and Fireproofing SOLUTIONS Inc. COMPANY PROFILE Specialty Firestop Contractor Over 15 years Experience In Process of becoming ULC Accredited

What is Firestop? A firestop, is a fire protection system made of various components used to seal openings and joints in fireresistance rated wall and/or floor assemblies.

This hotel has fire rated walls and floors Maintain Fire Separations Each unit is firestopped to contain the fire (and smoke) from spreading Compartmentalize

Definitions Rating criteria are derived from the standard CAN/ULC-S115. Intumescent is a substance which swells as a result of heat exposure, thus increasing in volume NBCC Ratings: o F (Fire) Ratings are the standard ratings required by the NBCC for the vast majority of situations o FT (Transmission of Heat) Ratings are required at firewalls and at floors above basements.

Definitions Annular Space - the opening around the penetrating item. Penetrating item building services; cables, cable trays, conduits, ducts, etc. that pass through a F.R. wall or floor. Firestop System Firestop material tested in specific assembly

Where is Firestop Required? All new construction & retrofit projects. Industrial, Institutional & Commercial Apartment Buildings Hospitals Schools Nursing Homes Office Buildings

Where is Firestop Required? Where fire rated assemblies are being penetrated o o o o o Fire Command Centers Stairwells Mechanical rooms I.T. Rooms Etc.

Why is Firestop Important? Life Safety Building Code Requirement o Occupancy Liability Water Seal Limit Losses o Production

Who Installs Firetop? Specialty Firestop Contractors Trades o Drywall o I.T. o Plumber o Electrician o Mason o Etc.

Firestop Products Mineral Wool Intumescent Sealant Silicone Silicone SL Acrylic Sealant Spray Mortar Foam Collars Wrap Strip Putty Pads Inserts Putty Pillows/Blocks Sleeves Composite Sheets

Mineral Wool Firestop Backer Rock Fiber Pre-cut to required width & depth Size: 2 wide X 4 deep X 48 long 3 wide X 4 deep X 48 long 4 wide X 4 deep X 48 long

Intumescent Sealant Premium Sealant Expand with heat Listed in majority of Tested Systems Cables Small Plastic Pipes

Silicone (non-sag and self- leveling) Water resistant Usable at any temperature

SILICONE (self-leveling)

Acrylic Sealant Water Based Economical

Firestop Spray Fast Less Material Economical

Mortar Light Weight Large Openings

Large Opening Solution

Can remedy an opening as big as 24 sq. ft. in one day

Collar Device for Plastic Pipes Expand to close melting pipe

WRAP STRIP Plastic Pipes (Similar to Collars) Make Collars on Site Economical One Size

Putty Pads Installed around back of electrical box Allows for closer placement of boxes in Fire Separations

Inserts Installed inside at back of electrical box Allows for closer placement of boxes in Fire Separations Ideal for retrofit where back of box is not accessible

PUTTY For Moderate Active Openings Stays pliable Reusable No sealant required

Pillows For Active Openings Reusable No sealant required

How to Install Material Select Systems that are Project Specific (submittal) What is the rating required? What is penetrating floor or wall? What is floor or wall made of? What is the Annular Space?

2 hour rated concrete floor 2 Copper pipe penetration 0 to 1 Annular Space

cul Fire Test Design No. C-AJ-1497

Thank you Questions?