COMMUNITY ANNUAL STORAGE ENERGY SYSTEM

Similar documents
PROPOSAL FOR THE PROMOTION OF GEOTHERMAL HEATING FOR THE TOWN OF MONO. June 2009 CONTENTS

EVALUATION OF A HIGH TEMPERATURE SOLAR THERMAL SEASONAL BOREHOLE STORAGE

White Paper. Geothermal Heating and Cooling

GEOTHERMAL HEAT PUMPS CONFIGURATIONS/INSTALLATION

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

Geothermal Heating & Cooling in Health Care Applications

Intelligent Process Cooling Technology Saves on Water and Energy, Improves Productivity

Ground-Coupled Heat Pump And Energy Storage

Energy Efficiency & Renewable Energy Resources

ACTIVE SOLAR SYSTEMS

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Chilled Water Plant Redesign

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Energy Savers: Air-Source Heat Pumps

Geothermal Comfort Systems

Chapter 9: Applications of the Laws of Thermodynamics

Project summary. 2 MW project Schalkwijk Haarlem Netherlands

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

LEED Commissioning and Actual Energy Use. John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering

Ground Source Heat Pump System Performance: Measuring the COP

Chapter 18 Renewable Energy

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

a.k.a. David N. Shaw, P. E.

Solar Energy Technologies

Chapter 8. Vapor Power Systems

SOLAR ENGINEERING OF THERMAL PROCESSES

Thermal Energy Storage

FLATE Hillsborough Community College - Brandon (813)

Value of Air Source Heat Pumps in Light of Variable Energy Prices. Jeff Haase. Energy Design Conference February 27, 2013

What type of radiation transmits heat energy? Complete this sentence. Hotter objects emit infrared radiation than cooler objects.

MSRE 517 SUSTAINABILITY PROPERTY REPORT STEPHEN JENSEN DANIEL REEVES WILLIAM SCOTT MSRE CLASS OF 2012 UNIVERSITY OF SAN DIEGO

Ground Source Heat Pumps in Cold Climates A REPORT FOR THE DENALI COMMISSION

Renewable Energy Today

2. Ground Source Heat Pumps Invitations to complete questionnaire Responses received... 7

WHAT IS DISTRICT ENERGY AND HOW DOES IT WORK?

Solar Thermal Radiant Heating at Pohakuloa Training Area

Rainwater Harvesting for Irrigation

MEMORANDUM. The general findings of the assessment are as follows:

Section 8 Energy and Energy Conservation

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Residential Swimming Pool Heating with Geothermal Heat Pump Systems

Thermal Analysis of Solar Flat Plate Collector

Cutting Peak Electrical Demand with Reflective Roof Coatings

The Integration of Large-Scale Solar Thermal and Heat Pumps in District Heating Systems

TECHNICAL EVALUATION OF OPTIONS FOR LONG-TERM AUGMENTATION OF THE COLORADO RIVER SYSTEM

This course provides an analysis of the effect of cool or highly reflective

Chapter Two. The Rankine cycle. Prepared by Dr. Shatha Ammourah

Research on Ground Source Heat Pump Design

Heat exchangers and thermal energy storage concepts for the off-gas heat of steelmaking devices

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Selecting Energy Efficient New Windows in Tennessee

Solar Thermal. [Strategy]

Selecting Energy Efficient New Windows in Nevada

Solar for Homeowners. Discover solar technologies for your home

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

A student investigated the efficiency of a motor using the equipment in Figure 1. Figure 1

HEat PumP technology FoR underfloor HEatINg comfortheat.com.au

INDUSTRIAL-RESIDENTIAL HEAT INTEGRATION BEST PRACTICE SOLUTIONS. Dr. Valter Mantelli. Technical Manager Iplom S.p.A. EFENIS Project Partner

Selecting Energy Efficient New Windows in Illinois

Green Movement Energizes Growth at ClimateMaster. Product Focus: Heating and Cooling. Company Profiles. plumbing heating cooling.

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Case study : RIO VENA (Seasonal Storage Solar DH Study)

SorTech package solution description

Low-Temperature District Heating and Earth Energy Systems By: Frank Lenarduzzi and Robert Mancini

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station

Selecting Energy Efficient Replacement Windows in Arizona

SIMULATION AND MODEL CALIBRATION OF A LARGE-SCALE SOLAR SEASONAL STORAGE SYSTEM

September Hybrid Air, Solar, and Ground Source Heat Pump Designs. Gaylord Olson, Yao Yu

DISTRICT HEAT DRIVEN ABSORPTION COOLING OF DISTRICT COOLING PLANTS IN TRONDHEIM, NORWAY

RETScreen ICE AND CURLING RINKS Model

A DIRECT SOLAR WATER HEATING SYSTEM FOR THE HEALTH CLINIC IN THE TOWN OF SANTA ISABEL CHOLULA, STATE OF PUEBLA, MEXICO

The desire for fossil fuel alternatives and environmentally friendly energy has

PureCycle 200 Heat-to-Electricity Power System

Unit 7 Overview of Solar Thermal Applications

Overview of Biogas Technology

INCREASE OF THE EFFICIENCY OF THE NEUBRANDENBURG GEOTHERMAL HEATING PLANT THROUGH SURPLUS HEAT STORAGE IN SUMMER

TransPacific Energy Advantage: Case Studies

Closed Greenhouse: a Starting Point for Sustainable Entrepreneurship in Horticulture

GEO-HEAT CENTER EXECUTIVE SUMMARY

Reading Utility Bills

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

Reducing Peak Energy Demand: The Hidden Benefit of Cool Roofs

3/6/2017 Past president & currently on the board of directors for the Wisconsin Geothermal Association

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

FEASIBILITY OF RENEWABLE ENERGY BASED DISTRIBUTED GENERATIONS IN YANBU, SAUDI ARABIA

Dry Flexicycle power plants a closed loop combined cycle with unique operational flexibility

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

Neil Eccles June SBED TSC Technology

Potential Reduction in Energy and Environmental Pollutants by Solar Assisted Ground Coupled Heat Pump Systems

Solar Powered Air Conditioning System

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

2. Is there anything I can do to prevent my water service lateral from freezing?

2. TECHNICAL DESCRIPTION OF THE PROJECT

7. Electrical Facility Ratings

Performance Testing of Cold Climate Air Source Heat Pumps

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

ALASKA PIPELINE PROJECT

Installing a Solar Power System on a Residential House Engineering and Financial Analysis Amal Kabalan, LEED A.P. Consulting Engineer

Transcription:

W. RICHARD POWELL COMMUNITY ANNUAL STORAGE ENERGY SYSTEM A new form of heating and cooling uses buildings instead of expensive devices to collect solar heat, which is then removed during the cooling process in summer, stored, and used as a primary source of heating in winter. Approximately a fourth of the energy demand in the United States is for heating and cooling buildings. Traditionally, we regard heating and cooling as two unrelated problems. In summer we consume electric power to run air conditioners that cool by pumping heat out of buildings and into the surroundings. In winter we consume precious and irreplaceable fossil fuels to generate about the same amount of heat as was thrown away during the previous summer. This is illustrated in Fig. 1, a typical seasonal pattern of heating and cooling in a moderate climate (Washington, D.C.). This wasteful procedure is left over from the era of cheap energy and can no longer be afforded. CASES CONCEPT The Community Annual Storage Energy System (CASES) is a new form of heating and cooling using solar energy. Instead of expensive solar collectors, the buildings themselves are used to collect solar heat, giving CASES a tremendous economic advantage over conventional solar energy systems. CASES stores the surplus heat removed from buildings during the cooling process in summer for use as a primary source of heat for winter. CASES also collects the excess heat that is produced in some community buildings even in winter and distributes it to the community to further reduce overall fuel consumption. At times, CASES obtains a portion of the heat required by the community directly from the winter environment. By using that heat, the stored summer heat, excess building heat, and heat released when water changes from the liquid to the solid phase instead of conventional heating fuels, the consumption of scarce fuel resources can be greatly reduced. Water is used to transfer excess building heat to storage. In order to collect heat from the building, the water must enter and leave the building at a temperature lower than the temperature desired in the building. Likewise, when this heat is returned to warm the building in winter, the fluid used must be hotter than the building. Thus, a heat pump is required to elevate the temperature of the water. CASES uses water as both the heat transfer fluid and the storage medium. Figure 2 illustrates how CASES works, using a 108... c Q.) g eo a. eo ~ -400 "0. ~ -800 ::J C" ~ -1200 Total cooling = 5.5 MWh (1.9 x 10 7 Btu) 1973 1974 CD o 4... x Fig. 1-Seasonal pattern of heating and cooling. Note that total annual space heating and space cooling demands are nearly equal. The actual thermal demand is based on a 406 unit apartment complex in Washington, D.C. Detached houses require more heating and less cooling. specific example. Because buildings are heated by water-source heat pumps and cooled by cold water, furnaces, air conditioners, flue pipes, and fires are not needed. Every building in the community has continuous access to a warm water and a cold water distribution line. In principle, a building could draw warm water to heat its north face and, at the same time, use cold water to cool its southern exposure. Aquifer Storage Generally, we cannot immediately use the waste heat and waste cold that are available in summer and winter, respectively. Figure 3 shows one of the most desirable ways to store excess warm and cold water. If natural underground water supplies (aquifers) are available, we inject the excess cold water produced in winter into the ground so that it will be available the following summer for cooling. Note also that we may collect additional cold water using natural cooling in winter and inject it along with the cold water produced by the heat pumps in the community. This ensures that there will be enough cold water for nonelectrical air conditioning even if the current winter happens to be a mild one and the succeeding summer is unusually hot.... c Q.) E t eo a. eo Juhns Hupkins A PL Technical Di1!esl

Waste cold recovery Waste heat recovery -- ~?_~--Warm-sou rce-- heat pump Heated air to living space Cold air return ~ Cold water main (40-45 F) Fig. 2-Synergistic interactions between buildings in a CASES community save energy and cost. By the end of winter, there is an ample supply of cold water in storage, while the supply of warm water is diminished. Ice Storage If local factors do not permit seasonal storage by means of an underground aquifer, it is necessary to provide an artificial method of storing the surplus summer heat and winter cold until they are needed. It does not appear economically feasible to store all of the cold water that is produced in winter as a by-product of heating with "water-source" heat pumps. Instead, the cold water flowing back to the central CASES facility is heated and returned to the community in a closed-loop flow pattern. The heat required can be extracted from water Warm water pipeline _ I Community buildings Env ironmental energy exchanger Co ld water pipeline Fig. 3-Aquifer flow patterns. Cold water for summer use accumulates in winter; warm water for winter use accumulates in summer. Volume I, Number 2, 1980 by an ice-making machine. For each cubic foot of cold water converted into ice by a machine, more than 10,000 Btu are made available for reheating the water circulating in the community distribution pipelines. Ice-making machines that take heat out of a cold pond will deliver more heat to the circulating water than could be obtained directly from the same pond if it were full of boiling water! Ice machines are simply heat pumps that also produce ice. The ice produced during winter is saved for nonelectrical "energy-free" cooling the following summer (Fig. 4). It is stored under a floating insulated roof in the same pond from which the ice machines remove heat in winter. As the winter progresses, more and more of the pond is converted into ice. During summer, this ice is melted while cooling the community. The size of the pond is chosen to be large enough to store all of the ice produced in winter and required for summer cooling. System Components Environmental Energy Exchanger - Part of the heat used to reheat the water circulating in the community when CASES employs ice machines and a pond for annual storage can be collected energyfree directly from the environment with an environmental energy exchanger (EEE). This exchanger is more economical than most solar heaters because it has no cover glass and, operating at a lower temperature, it is more efficient than most solar collectors. It can also be used after sunset to collect heat from the air any time the air temperature is significantly higher than the cold water temperature. In northern communities, the EEE can collect heat to melt ice in the pond any time the air 109

Underground pump and ice machine complex Ice Water Short-term warm-water storage ----+- 39 F water for cooling or ice (snow) collection Spray pump is shared: ice collected if air < 32 F, heat collected if air> 60 F Fig. 4-Pond annual storage system with ice or heat collection via spray type environmental energy exchanger. temperature is above freezing. By melting excess ice, it is possible to freeze the water in the pond several times during one winter and obtain as much heat as if the pond were several times larger. Thus in locations where more heat is needed for heating buildings during winter than is removed from buildings during summer cooling, the exchanger can be used both to substitute cost-free environmental heat for ice-machine heat and to reduce the size and cost of the pond. In southern locations, the heat removed from buildings in summer exceeds the heat required in winter. The design of the EEE would correspondingly differ from that used in a northern location. The exchanger might be a water spray cooling pond. The exchanger can be used to discharge the seasonally excess heat in winter without using electrically driven air conditioners if aquifer storage is feasible (Fig. 3). However, if a pond is used for annual storage, the exchanger can be designed to produce and collect ice in winter, using a water spray and natural cooling, to supplement the ice produced as a by-product of winter heating. Thus the EEE is used to achieve an annual balance in the heating and cooling loads and to reduce both energy consumption and costs. An exchanger used for both ice and heat collection is part of the central CASES facility illustrated in Fig. 4 and schematically represented in Fig. 5. "Water-Source" Heat Pumps - The watersource heat pumps used in CASES buildings remain highly efficient even in cold weather because warm water from the pipeline is always available to them as a source of heat. By contrast, "air-source" heat pumps tend to condense water vapor from the air and freeze up in cold weather so that periodic defrost cycles are required. Also they become less efficient as the weather becomes colder. In subfreezing weather, most air-source heat pumps deliver no more heat than simple resistance heaters, whereas the water-source heat pumps used in CASES typically give 3.5 times more heat than electric resistance heaters or air-source heat pumps at the time of peak demand. It should be noted 110 that some energy is consumed at the central CASES facilities to keep warm water continuously available, but much of it is produced cost-free or is recovered as excess heat from buildings with cooling needs. The water-source heat pumps are similar in design to air-source heat pumps except that their input heat exchanger is smaller and no outside fancoil unit is required. They should be more economical than air-source heat pumps when produced in the same volume. The absence of outside fan-coil units reduces installation costs and lessens the chance for fluorocarbon leaks to the environment. Water-source heat pumps can be hermetically sealed at the factory, but air-source heat pumps typically require field connections for fluorocarbon lines between the inside and outside units. Short- Term Storage Facilities - Even when aquifers are available, short-term warm and cold water storage facilities at ground level may be desirable to buffer the flow of warm and cold water into the aquifers. Typically, their volume is large enough to permit a major portion of the demand for heating water during the hours of peak electric usage on cold winter days to be satisfied directly from stored warm water with minimal use of electric power. The well pump and well-field borehole costs can be reduced if part of the peak Warm water storage Warm pipe Environmental energy exchanger Fig. 5-Heat and fluid flow diagram for CASES central plant with ice machine heat pump. Juhns Hupkins APL Technical Diges/

flow is into and out of water storage basins on the surface. Excessive flow rates result in greater pumping power requirements and can damage the aquifer if the pressure rise ruptures a natural clay seal. An ice-collecting EEE can be useful even with aquifer storage if it is coupled to these short-term storage facilities. On the coldest winter nights, ice can be collected rapidly and then can be converted into cold water for injection into the aquifer at lower flow rates. The savings in peak power or "demand" charges possible with short-term storage facilities are most important when the ice machines can be operated at night or at other times when electric power is cheap. Many electric utility companies have recognized that the cost of thermal storage can be less than the cost of expanding peak generation and transmission facilities. Central energy storage can reduce the cost further because the large scale results in a more economical surface-to-volume ratio. The cost of separate electric meters for off-peak electric power is reduced, and only one meter for each rate period is required for the entire community. The short-term storage facilities available at the central CASES plant could be operated to produce a more cost-effective form of load control for the electric utility. The ability to take all ice-machine heat pumps off line for a few hours in power emergencies could prevent a blackout in the community. During this period, all of the central plant thermal output would be drawn from the shortterm storage facilities. Water Distribution Pipelines. - The principal disadvantage of CASES is its requirement for a water distribution system. Because the warm and cold water circulating in these lines is only a few degrees different from ground temperatures, insulating the pipelines does not appear cost effective. Although the lines would be essentially identical in construction with potable water lines, they would be cheaper because the water used in CASES pipelines is not consumed nor is it processed to potable water standards. The heat lost (or gained) during distribution in the uninsulated pipes is estimated to be less than 10% of the delivered resource. Long- Term Storage Facilities - Electric utility companies usually have a seasonal imbalance in the demand for electric power as well as daily peaks in the electric demand curves. The fact that CASES provides air conditioning nonelectrically (either by cold water from an aquifer or by melting ice stored from winter) can reduce the chance of blackouts or the need for expansion in generating capacity to service peak loads. The fact that CASES would replace present gas and oil furnaces with electrically powered heat pumps is also attractive by adding electric demand in winter for summer peaking utilities. Volume I, N umber 2, 1980 For an electric utility with a wintertime peak demand, the surplus heat collected in summer is the attractive long-term storage feature. Together with proper use of short-term storage facilities for diurnal load management, this permits the peak electric heating demand to be about 3.5 times less than if air-source heat pumps were employed. Ice Machines - The ice machines used in CASES are designed to produce flake ice because heat transport through thick ice would make the machines less efficient and more costly. Flake ice can be pumped as an ice/water slurry to the storage pond. The slurry would be discharged into the storage pond at the bottom to keep the discharge pipe clear of ice. Because ice machines are not needed for heating in summer, they could be used to manufacture ice for sale to defray part of their costs, if a local industrial customer (e.g., a food processor) is available. ANALYSIS Evaluation of any annual storage energy system requires data for a full year. The costs and performance characteristics of CASES have been determined using a simulation model that consists of 8760 hours (one year) of sequential steady states. The simulation model assumes that a pond rather than aquifers is used for annual storage. It thus sets an upper limit on costs and a lower limit on efficiency, because ice machines are more expensive and less efficient than pumping warm and cold water into and out of the ground. Cases Model The first program module in the simulation is called HCLOAD. It produces a file of hourly heating and cooling loads (Btu/h) for each of nine building types and two core zones. In addition, certain monthly and annual peak and total loads are recorded that are used in subsequent program modules to determine efficiently the size of heating and cooling equipment required in each building and the size of various energy storage facilities needed at the central CASES plant. The second module (CDIST) requires as input the distribution water temperatures in addition to the files written by HCLOAD. It calculates the size and cost of the heating and cooling equipment needed for each building. It produces an hourly record of the electric power required to operate the heating and cooling equipment. It also converts the load data into a demand (pounds of water per hour) data file, which depends on the water temperatures and the efficiency of the equipment selected for each building. CDIST uses the water-demand file and data on the pipeline route to each terminal building to determine the size and capital cost of all pipes and trenches in the distribution system. More refined editions also calculate pumping and thermal losses III

and the associated costs. The current simulation model doubles costs of the pipe and trench to form a conservative estimate of pipeline and other cost details omitted from the distribution system. Finally, it reduces all the demand data to a single user or net demand file. The third module (CAPS) simulates hourly operation of the central CASES plant as it services the user under an assumed set of operating rules. It determines the size and cost of the various energy storage facilities and ice machines required at the central plant and also computes the hourly requirements for electrical power. The final module (COST) processes all the various cost and energy consumption files. Various financial rates and Btu prices are used to determine the total cost of CASES and the expected rate of return on invested capital. COST totals all energy consumption and compares it to the heating and cooling services supplied in order to evaluate the efficiency and annual energy savings. COST does not presently exist. Instead, hand calculations are used to combine the results of CDIST and CAPS. In lieu of detailed economic analysis, it is assumed that 15070 of the capital is recovered annually. Reference Community To obtain reliable information about costs, the community must be specified in considerable detail. The selected model community was similar to Wilde Lake Village in Columbia, Md. It has 8000 residents (2500 households) and 866 buildings in three neighborhoods that share a common village center, all on 1500 acres of land. Each neighborhood has its own elementary school and civic/commercial center. The community's middle school, high school, office buildings, factory, shops, and CASES facility are located in the village center. These buildings and clusters of residential units comprise the 43 zones (local load centers) shown in Fig. 6, which also illustrates the route of major distribution lines but not the connections to in- dividual buildings in each zone. Hourly weather records for 1967 were used. RESULTS The results predicted by the simulation model for the standard reference community are given in Table 1. The capital invested to provide heating and cooling services to both residential and non- Table 1 MONTHL Y SUMMARY FOR STANDARD COMMUNITY Efficiency, Services Provided (1967) Combined Heating Cooling Coefficient of Month (Btu x 10 6 ) (Btu X 10 6 ) Performance January 59,460 15,150 4.509 February 69,430 13,130 4.001 March 43,240 16,190 5.279 April 25,780 17,410 6.707 May 38,170 16,100 5.414 June 8,285 21,110 12.142 July 4,809 22,220 17.216 August 7,000 20,210 13.411 September 11,120 19,500 10.515 October 30,230 17,310 5.783 November 49,760 14,880 4.972 December 60,580 14,870 4.586 Total for year 407,864 208,290 5.524 Capital cost at central plant $5,097,000 Capital cost for pipelines 1,435,000 Capital cost in buildings 8,758,000 Total capital invested $15,290,000 (Electrical utility capital excluded) Total electric cost $1,047,000 15070 of capital total as annual cost 2,294,000 Total revenue required annually $3,341,000 SFD - Single family dwelling TH - Townhouse G - Garden apt. N - Neighborhood center 50 SFD 85 SFD 80 SFD 50SFD 50SFD 25 SFD E N 25 SFD E - Elementary school HS - High school MS - Middle school o - Office bu ilding 50 SFD 50 SFD 50SFD---,...-~ ~----~----85SFD Fig. 6-Layout of 866 buildings and pipeline route in standard reference community. 112 Johns Hopkins APL Technical Digest

residential buildings in the standard reference community is less than $6200 per resident household. Typically, conventional residential solar-electric hybrid systems costing this amount would require more electric energy for back-up heating on cloudy days and would not provide any cooling. Thus CASES provides more services to more buildings with less capital and lower energy consumption than does a conventional solar heating approach. The reference community requires a total investment of about $15 million. If an electric utility company with a wintertime peak load could produce an increment of new capacity at a cost of $700 per kilowatt, then $20 million of electric plant expansion would be needed to supply the increased peak demands of the community if it were electrically heated and cooled. The reference community requires twice as much total annual heating as cooling; however, four times as much is charged per unit of cooling than of heating, so that twothirds of the system's revenues come from cooling. (People currently pay about four times more to remove a Btu than to add one to their homes when equipment costs are properly included in the comparison.) In the model, electric power costs about $10 per million Btu if consumed at the central plant, where industrial rates and "off-peak" power rates are assumed to be available. The net effect of these and other factors is that our model predicts heat co'sts of $2.69 per million Btu. This is less than the cost of the fuel alone in most conventional systems. All costs are in 1978 dollars. Neither the standard reference community nor the design parameters and control strategy assumed has been selected to optimize the cost and performance characteristics of CASES. Work in this area is incomplete, but some preliminary results indicate that other communities and other designs may be more efficient and economical. The standard reference community model assumed that the temperature of cold water was 40 F but parametric studies indicate that 45 OF water may be more economical. (Ideally, the temperature of both the cold and warm water pipelines should vary with the weather for optimum results, but the computer code required to simulate this variation is not yet operational. ) CASES is most attractive in thermally diverse communities where the annual cooling requirements are about two-thirds of the annual heating requirements. There it can profitably deliver three units of heating and two units of cooling for every unit of electricity consumed. It is especially attractive in such applications if the local electric grid is summer peaking or if electric resistance heating makes it a winter peaking grid, because CASES can reduce peak electric demand in either case. It appears to be economically feasible in new suburban areas if large buildings or other winter cooling demands are present, provided that the gross population density is five people per acre or greater. Its technology is suitable for an urban retrofit site because heat pumps can be selected individually to match existing ducts or radiators. The thermal storage facilities can be placed under existing facilities such as athletic fields and parks, and public fountains can provide controlled heat exchange with the environment. Volume I, Number 2,1980 113