TITLE: SLAUGHTER HOUSE SEPTIC TANK. ITEM No. D E S C R I P T I O N UNIT QTY

Similar documents
Estimate FOR THE SEPTIC TANK

Development of the Urban Water and Sanitation Sector in South Sudan (DUWSS) Bill of Quantities. for LOCATED AT PRIMARY & SECONDARY SCHOOL.

Description Unit Quantity Rate Kshs. Amount Kshs.

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

PART A : CPVC PIPES AND FITTNGS (EXTERNAL WATERSUPPLY):

Concrete Slab-on-Ground

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

BILL OF QUANTITY ENGINEERING & MANAGEMENT CONSULTING CENTRE. "Beit Hanoun Emergency Water Supply Project"

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

REPUBLIC OF LEBANON MINISTRY OF ENERGY AND WATER UNITED NATIONS DEVELOPMENT

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

Appendix 4. Bills of Quantities

REPUBLIC OF LEBANON MINISTRY OF ENERGY AND WATER UNITED NATIONS DEVELOPMENT

BILL OF QUANTITIES. Construction and Rehabilitation of wadi Gaza Bridges PAL Funded by Government of Brazil

SECTION UTILITY MANHOLES AND STRUCTURES

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

Hepworth SuperSleve Drainage Specification

Construction Specification for Utility Adjustments

SECTION STORM DRAIN

A. BILL OF QUANTITIES FOR SANITARY SEWER

***************************************************************************************************************

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

(For compliance with the new sewers for adoption regulation or building regulations part H1)

RFP/GRC/LSV/ : RENOVATION (CIVIL WORKS) AT SKALA SYKAMNIAS CHILDRENS PLAYGROUND BILL OF QUANTITIES

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

SECTION FACILITY SANITARY SEWERS

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

ANNEX 3 DETAILED PRICE SCHEDULE RELATED TO THE BILL OF QUANTITIES 1. GENERAL DESCRIPTION OF ITEMS PRICES TO BE FULLY INCLUSIVE...

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

VILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER SS BID PROPOSAL

Improvements to the Distribution Pipe Lines in Zalengi, Central Darfur Please insert the currency Item Description

SECTION A1 EXCAVATION AND BACKFILL GENERAL

***************************************************************************************************************

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Rodding Eye Details. Inspection Chambers

SECTION CAST-IN-PLACE CONCRETE

Wavin: Range 600 Inspection Chambers

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

ARCHITECTURAL DRAWINGS

PRECAST RECTANGULAR CHAMBERS

Section Storm Sewers STORM SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Storm Sewers. B. Abandonment of Storm Sewers

TYPE "A" CATCH BASIN

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

CONSTRUCTION SPECIFICATION FOR CONCRETE CROSSWALK INDEX TS SCOPE...3

16. Design of Pipeline Structures.

DIVISION 31 EARTHWORK 2006 Edition, Published January 1, 2006; Division Revision Date: January 31, 2012

Section 2: Underground

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

D-1 THE CITY OF HARRISBURG 1 1/2" MIN. ID-2 WEARING COARSE EXISTING STREET SURFACE AC-20 SEALER (ALL AROUND) 1 1/2" MIN. ID-2 BINDER COARSE

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

PART A: JOB PROCDRE FOR PLASTERING

Residential Building Inspections

Retaining Walls. Made Easy

CLEVELAND DIVISION OF WATER CONSTRUCTION STANDARDS. Details Index

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

SEPTIC TANK CONSTRUCTION GUIDELINES

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

PARTICULAR SPECIFICATIONS PLUMBING AND SANITARY WORK

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

BOQ for Plumbing, Sanitary Works

TOWN OF MOUNT PLEASANT WESTCHESTER COUNTY, NEW YORK

SECTION PLUMBING PIPING SYSTEMS

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Daytona Beach Pier Building Renovation Jun 2010

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT

M I N N E S O T A D O T BID TABULATION SUMMARY JOB PAGE 1 ON 03/16/94 MINNESOTA PROJECT NO.S: STP 5822(002)

PUBLIC WORKS SKAGIT COUNTY SAMISH ISLAND ROAD SAMISH ISLAND ROAD SLIDE REPAIR

WATER 6.1 GUIDELINES

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

SECTION DUCTILE IRON FITTINGS. A. This section includes materials, installation, and testing of ductile iron fittings 48 inches and smaller.

CONSTRUCTION AND REHABILITATION OF FENCE AT GPL'S VERSAILLES COMPOUND

HomeGuard DPC Termite Moisture Barrier

SECTION MEASUREMENT AND PAYMENT

DIVISION 3 PAVEMENT (FLEXIBLE AND RIGID) CONSTRUCTION SPECIFICATIONS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

INDEX FOR SPECIFICATIONS FOR JACKING CULVERTS THROUGH EMBANKMENTS SCOPE... 2

Facility Sanitary Sewers

D R A F T. NBS Domestic sample NBS. A9 General requirements. D2 Site preparation. E1 Concrete foundations and floors. F1 Masonry walling

UNOPS UNITED NATIONS OFFICE FOR PROJECT SERVICES PROJECT BOQ. Original Issue Bamyan MAC Site Services - Phase 1 Bamyan, Bamyan, Afghanistan

CONSTRUCTION STANDARDS SECTION CS 3 TRENCH FOUNDATION, BEDDING AND BACKFILL

Method of Measurement for Road Works Series MM Structural Concrete

JUST THE FACTS CONCRETE PIPE VS. HDPE

Construction Specification for Concrete Unit Pavers

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

SPECIFICATION FOR REINFORCED SOIL WALL

Specifications for Electrical Underground Residential Distribution Systems

South Waikato District Council Code of Practice for Subdivision and Development PART 4. Drainage. Part 4: Drainage 56

Appendix J: Storm Conveyance Design Parameters

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

UNIT III Earthwork Estimation & Reinforcement Estimation

Schedule T5. Tender Documents. This tender is for: Tender Documents: The documents issued for this tender include the following: Tender Schedules

CITY OF EDMOND STANDARD SPECIFICATIONS FOR CONSTRUCTION Edition

Transcription:

D DEMOLITION & SITE CLEARANCE D1 GENERAL CLEARANCE 6-D152 Open bush and thicket in and around ha 0.02 the ponds. Locally disposed. D2 REMOVAL OF TREES AND STUMPS 6-D212 Trees of girth: 150 mm - 500 mm nr 2.00 locally disposed. (Provisional) 6-D262 Stumps of diameter: 500 mm - 1 m nr 2.00 locally disposed. (Provisional) D4 DEMOLITION OF OTHER STRUCTURES, DISPOSAL, LOCAL 6-D464 No predominant material sum 1.00 volume: 250-500 m 3. (Provisional) D5 CLEARANCE OF PIPELINE WAYLEAVES, DISPOSAL LOCAL 6-D521 Nominal bore: 100-300 mm., m 200.00 Pipeline only (Provisional) D6 REMOVAL OF ANT AND TERMITE HILLS AND NESTS 6-D622 Along pipeline routes, excess m 3 5.00 material - locally disposed. (Provisional) E EARTHWORKS E4 GENERAL EXCAVATIONS Septic tank construction 6-E425.2 In class I material max. depth m 3 10.00 0.0-0.3 m. 6-E435.2 In class II material max. depth m 3 35.00 0.3-1.3 m. 6-E445.2 In class III material max. depth m 3 30.00 1.3-2.1m. D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 1 of 7

E6 FILLING AND COMPACTION In free draining material 6-E611.4 To structures using selected m 3 15.00 excavated class III material. 6-E612.2 To structures using imported m 3 6.00 class I material. F IN-SITU CONCRETE F1 PROVIDE CEMENT FOR CONCRETE 6-F111.1 Ordinary Portland cement to ton 7.30 SSRN 103. In 50 Kg bags. F3 DESIGNED MIX FOR ORDINARY STRUCTURAL CONCRETE FOR CLASS B EXPOSURE USING ORDINARY PORTLAND CEMENT 6-F326 Provide concrete grade 15. m 3 1.50 All in aggregate 40 mm max. in blinding and as mass concrete. 6-F346 Provide concrete grade 25. m 3 9.00 All in aggregate size range 40 mm max. for slabs and suspended beams. F7 PLACE MASS CONCRETE 6-F712 As blinding m 3 1.50 thickness: 50-100 mm. 6-F722 In bases footings and ground m 3 0.85 slabs thickness: 50-100 mm. F8 PLACE REINFORCED CONCRETE 6-F823 In bases, footings and ground slabs m 3 4.20 thickness 100-150 mm. 6-F823 In suspended slabs m 3 3.85 thickness 100-150 mm. 6-F862 In beams cross-sectional area 0.03-0.1m 2. m 3 0.25 D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 2 of 7

G CONCRETE ANCILLARIES G1 FORMWORK : ROUGH FINISH 6-G143 Plane vertical, Width 0.2-0.4 m m 2 3.50 G2 FORMWORK : FAIR FINISH 6-G2143 Plane horizontal: width exc. 1.22 m. m 2 30.00 G5 REINFORCEMENT 6-G523 High yield steel bars to SSRN 127, diameter 10 mm t 0.50 G8 CONCRETE ACCESSORIES 6-G811 Finishing of top surfaces using wood float. m 2 55.00 6-G812 Finishing of top surfaces using steel trowel. m 2 38.00 (Apply a uniform cement mortar screed to all internal walls) I PIPEWORK - PIPES, SEWERS & FITTINGS SUPPLY I1 PIPES AND SEWERS upvc to SSRN 300 6-I162.4i S&S standard joints with rubber m 100.00 o - ring seal PN 9/10, dia. 110 mm. (Provisional) I5 FITTINGS IN u PVC TO u PVC PIPES Bends Double socketed 6-I523.4i 110 mm dia. NP 9/10 (Provisional) nr 10 Junctions and branches Plain Tee Socketed Branch 6-I544.4i 110/110 mm dia. NP 9/10 nr 2.00 Wye Socketed Branch 6-I549.4i 110/110 mm dia NP9/10 (provisional) nr 1.25 End Caps 6-I898.4 150mm dia. Inspection cap nr 2.00 on top end of Tee on inlet/outlet Ref Drg YEI-SAN-ST-1.0 D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 3 of 7

J PIPEWORK PIPES & FITTINGS - INSTALL J1 METHOD OF MEASUREMENT TYPE A IN METRES u PVC pipes and fittings 6-J162.3 N.b. 100-200 mm., in m 100.00 trenches, depth: 1-1.5 m. J2 TESTING 6-J222 Test pressure not exc. 6 bar m 100.00 J4 METHOD OF MEASUREMENT TYPE B BY NUMBER: 6-J422.21 Plain ended tee N.b. 100-200 mm nr 2.00 Not in trenches. (incl.end cap) K PIPEWORK MANHOLE & PIPEWORK ANCILLARIES K1 MANHOLES AND OTHER CHAMBERS IN ACCORDANCE WITH STANDARD DRAWINGS Masonry or blockwork 6-K177.22 Sewer manhole, pipe nom. bore exc. 100 but nr 2.00 not exc. 200 mm., depth 1.5-2 m. (Provisional) 6-K187.22 Sewer manhole with back drop, pipe nom. bore nr 2.00 exc. 100 but not exc.200 mm.depth 1.5-2 m. (Provisional) K2 CONCRETE MANHOLE COVERS & SURROUNDS 6-K252 Precast concrete, area 0.5-1 m 2. (Provisional) nr 4.00 K4 FRENCH DRAINS, RUBBLE DRAINS & DITCHES Septic Tank Percolation trench 6-K41 Filling of trench and rubble m 3 72.00 drains with graded material. K7 REINSTATEMENT 6-K742 Breaking up, temporary and permanent reinstatement of m 50.00 dirt roads as specified by engineer. Pipe. Nom. bore n.e. 250mm (Provisional) D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 4 of 7

K8 OTHER PIPEWORK ANCILLARIES Marker posts for 6-K826.2 Sewer pipelines nr 5.00 K9 METAL COVERS Cast iron Septic Tank covers 6-K923.3 With heavy duty cover & frame nr 4.00 Area: exc. 0.5 but not exc 1 m2. L PIPEWORK-SUPPORTS & PROTECTION ANCILLARIES TO LAYING & EXCAV. L1 EXTRAS TO EXCAVATION AND BACKFILLING 6-L111 In pipe trenches excavation m 3 132.00 of rock class II material L5 SURROUNDS 6-L522 Selected excavated granular m 100.00 material,pipe nom.bore 100-200 mm. N MISCELLANEOUS METALWORK N1 MILD STEEL 6-N182 600mm by 800mm coarses screens, 30-50mm dia. m 2 0.50 6-N195 150mm by 500mm fixed mild steel channel plate m 1.40 U BRICKWORK, BLOCKWORK AND MASONRY U1 COMMON BRICKWORK 6-U131 Composite construction Thickness 150-250 mm m 2 38.00 in vertical straight walls 6-U692.1 225 mm wide approved quality 3-ply bituminous felt damp m 20.50 proof course under walls D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 5 of 7

PROVISIONAL ITEMS SLAUGHTER HOUSE SEWER 1 EARTHWORKS 1a GENERAL EXCAVATIONS a1 In class I material max. depth 2-5m m3 2.50 a2 In class II material max. depth 2-5m m3 8.75 a3 In class III material max. depth 2-5m m3 7.50 2 PIPEWORK-PIPES, SEWERS & FITTINGS ---SUPPLY 2 Upvc pipes a S & S standards joints PN3, dia. 160mm m 25.00 3 PIPEWORK PIPES & FITTINGS ---INSTALL 3a METHOD OF MEASUREMENT TYPE A IN METERS 3a1 upvc pipes N.b 100-200mm in trenchs, depth: 2-3m m 25.00 4 TESTING test pressure exc. 6 bar but not exc.12 bar, m 25.00 5 PIPEWORK MANHOLE & PIPEWORK ANCILLARIES 5a MANHOLES AND OTHER CHAMBERS IN ACCORDING WITH STANDARD DRAWING 4a1 Masonry or blockwork Sewer manhole, pipe nom. Bore exc. 100 but not exc. 200m, depth 1.5-2m nr 5.00 6 CONCRETE MANHOLE COVERS &SURROUDS 6a Precast concrete, area 0.5-1m2 nr 5.00 D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 6 of 7

COLLECTION SHEET PAGE NO. 1 2 3 4 5 6 TOTAL CARRIED TO GRAND SUMMARY D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxST Page 7 of 7

Detailed Design and Preparation of Tender Documents for Water and Sanitation Facilities, Yei Town - South Sudan SUMMARY YEI-GIZ Contract Description Bill Amount (Euro's) 6 Slaughter House Septic Tank BILL OF QUANTITIES SUB-TOTAL 10% for physical contingencies BILL OF QUANTITIES TOTAL (excl. TAXES and DUTIES) D:\HKendagor\Documents\YEI Water Project\Tender Documents\2_Bills of Quantities\BoQ - Rev B.xlsxSummary Page 1 of 1