CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

Similar documents
CERTIFICATE OF APPROVAL No CF 513 FSI LIMITED

CERTIFICATE OF APPROVAL No CF 816 BIP GMBH

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

CERTIFICATE OF APPROVAL No CF 5363 NULLIFIRE LIMITED

CERTIFICATE OF APPROVAL No CF 5403 ARC BUILDING SOLUTIONS LIMITED

CERTIFICATE OF APPROVAL No CF 5207 QATAR AERATED CONCRETE INDUSTRIES CO. W.W.L.

CERTIFICATE OF APPROVAL No CF 663 HILTI AG

CERTIFICATE OF APPROVAL No CF 5345 BERGER PAINTS EMIRATES LTD CO (LLC)

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2

Kent, DA1 4FT. appended hereto:

CERTIFICATE OF APPROVAL No CF 242 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 820 ZMR LTD TRADING AS MILLENNIUM DOOR SYSTEMS

CERTIFICATE OF APPROVAL No CF 154 J B KIND LIMITED & IRMADE- INDÚSTRIAS DE REVESTIMENTO DE MADEIRAS, S.A.

U L - E U C E R T I F I C A T E

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

CERTIFICATE OF APPROVAL No CF 355

Tehnical Data Sheet Pyrocoustic Sealant UIC of product-type: PYROC

CERTIFICATE OF APPROVAL No CF 5497 AL HUDA INTERIORS FACTORY LLC

CERTIFICATE OF APPROVAL No. CF 5102 ETERNIT AKTIENGESELLSCHAFT

CERTIFICATE OF APPROVAL No CF 339 EURO SPEC

CERTIFICATE OF APPROVAL No CF 5389 FINANCIERA MADERERA SA

HILTI CP 606 Flexible Firestop Sealant

REGULATORY INFORMATION REPORT

Technical Data Sheet. Hilti Firestop Foam CP 660. Firestop Solutions in Accordance with AS & AS BWA Report No

appended hereto: E119-10b 252: 2008

HILTI CP 657 Firestop Brick

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

This European technical approval

European Technical Assessment. ETA-11/0372 of Member of. General part

DECLARATION OF PERFORMANCE

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

June Residential Refurbishment Separating walls

FIRE STOP PRODUCTS. As innovative manufacturers, we are continuously adding to our range, meeting the needs of a highly demanding market.

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

DECLARATION OF PERFORMANCE

HP Partial Fill. Robust, long-lasting protection

3M CS-195+ Composite Sheet Product Description

HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems

K12 Framing Board. Insulation

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

GypLyner UNIVERSAL Metal framed wall lining system

European Technical Assessment ETA-17/0741 of 29/08/2017

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Firestop and Fire Protection Systems

HILTI CP 601S Elastomeric Firestop Sealant

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

K5 External Wall Board

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

The Passive Fire Protection Handbook

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

Assessment Number BTC 14254FA

European Technical Assessment. ETA-12/0101 of Member of. General part

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

The extra strong, extra durable, sound resistant system that you can direct fix to

HILTI CP 617 Intumescent acoustic putty pad

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

BDA Agrément BAW /01/C

Product Information Sheet

European technical approval

Fire Door Installation

RMF Intercell. NBS Specification 2013 K41

Technical Data Sheet. Hilti Firestop cable collar CFS-CC. European technical approval ETA N o 13 / Issue 10 / 2013

Thermal Laminate Board.

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

Staggered stud acoustic partition system

GypLyner UNIVERSAL Metal framed wall lining system

VENTILATED FIRE BARRIERS FOR EXTERNAL CLADDING AND RAINSCREEN SYSTEMS

SOUND INSULATION TESTING IN DWELLINGS

Page No 1 Introduction... 3

CERTIFICATE OF APPROVAL No ME 5084

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS FOR JOINTS AND PENETRATIONS

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

K5 External Wall Board

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

ÖSTERREICHISCHES INSTITUT FÜR BAUTECHNIK

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

HILTI CP 643N Firestop collar

Core. Thickness. Biological

June Non - Residential Refurbishment Internal lining walls

GypLyner (walls) Metal framed wall lining system. GypLyner.

C05. S03. P02 P08 FireWall

Smoke Control Damper ESAM Instructions for installation, operation and maintenance 10/2014

Property of Cooks Plumbing Supplies

Brick Veneer Walls. Insulation

Issue date: 1st May Key changes since original publication (July 2005):

Installation Guide and Safety Manual

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

European Technical Assessment. ETA-16/0320 of Member of. General part

Building Design Data

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

Hilti Firestop Coating CFS-CT. Hilti AG Feldkircherstrasse Schaan Liechtenstein

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Transcription:

CERTIFICATE OF APPROVAL No CF 517 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Westminster Industrial Estate, Tamworth Road, Measham, DE12 7DS Tel: 01530 515130 Fax: 01530 273564 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT BA120, Pyrocoustic & Pyropro LST Sealant in all colours TECHNICAL SCHEDULE TS03 Fire Resisting Penetration Seal Systems TS40 Linear Gap Sealing Systems Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Chairman - Management Council Page 1 of 13

BA120, Pyrocoustic & Pyropro LST Sealant 1. This approval relates to the use of BA120, Pyrocoustic & Pyropro LST Sealant for the fire protection of movement joints within walls and floors and for the sealing of gaps around various pipes and cables penetrating flexible and rigid walls. The detailed scope is given in the Approval Matrix included in this Certificate. This shows the thickness and acceptable services for BA120, Pyrocoustic & Pyropro LST Sealant required to provide fire resistance periods in accordance with BS 476: Part 20: 1987, EN1366-3: 2009 and EN1366-4: 2006 of up to 240 minutes for wall/floor constructions. The scope of certification complies with the guidelines stated in the ASFP Red Book: 3 rd Edition for 3 rd party certification schemes. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section 2 of the Technical Standards (Scotland),Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account. 3. The product is approved on the basis of: i) Initial type testing ii) Audit testing at the frequency specified in TS03, TS40 iii) A design appraisal against TS03, TS40 iv) Inspection and surveillance of factory production control 4. The concrete walls and drywall shall be at least 100mm thick (see individual tables) and the floors at least 250mm thick (see individual tables) and have at least the same fire rating as that required for the penetration seal. 5. Masonry and concrete gap faces will be within the density range of 450 to 2300kg/m 3, (see individual tables) and gap faces will be free from loose or flaking material. 6. Backing or support materials may be polyethylene, Ethafoam or mineral fibre insulation depending upon the system. 7. The approval relates to on-going production. Product and/or its immediate packaging is identified with the manufacturers name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. Further information regarding the details contained in this data sheet may be obtained from FSi Limited (Tel: 01530 515130). Further information regarding the CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777). Page 2 of 13 Signed

BA120, Pyrocoustic & Pyropro LST Sealant BS 476 Approval Matrix Wall and Floor Installations:- Double Sided Seals Max. Joint Width Material Wall Constructions (min 250mm thick) Floor Constructions (min250mm thick) Brick/Autoclaved Brick/autoclaved Steel/ aerated blockwork Steel/ aerated blockwork Hardwood/ aerated blockwork Softwood/ aerated blockwork Aerated concrete/ Aerated concrete/ Aerated concrete/ Aerated concrete/ Softwood/ Hardwood/ Steel/ 20 10 Polyethylene 30 15 Polyethylene 40 20 Polyethylene 60 mm diameter 300 300 300 210 300 210 300 210 15 10 Polyethylene 240 0 25 10 Polyethylene 240 30 30 15 Polyethylene 300 90 50 25 Ethafoam 60 30 50 25 Ethafoam 60 60 25 12 Ethafoam 30 30 20 10 Polyethylene 300 120 30 15 Polyethylene 300 60 40 20 Polyethylene 300 60 300 210 60 mm diameter 25 12 Ethafoam 30 30 50 25 Ethafoam 30 30 50 25 Ethafoam 60 60 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 3 of 13 Signed

BS 476 Approval Matrix Floor Installations:- Single Sided Seals Max. Joint Width Floor Constructions (min 150mm thick) Material 40 20 Polyethylene 30 15 Polyethylene 20 10 Polyethylene 240 90 240 45 240 45 240 45 45 45 40 20 Polyethylene 30 30 30 15 Polyethylene 30 30 20 10 Polyethylene 30 30 240 90 40 20 Polyethylene 240 30 30 15 Polyethylene 240 30 20 10 Polyethylene 240 30 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 4 of 13 Signed

EN1366-4 Approval Matrix Wall Installations:- Single Sided Seals- Sealant installed to either side of wall Max. Joint Width Material Wall Constructions (min 100mm thick) 20 10 Polyethylene 120 60 120 45 50 50 Polyethylene 45 45 20 10 Polyethylene 30 20 50 50 Polyethylene 45 30 20 10 Polyethylene 120 20 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 5 of 13 Signed

EN1366-4 Approval Matrix Wall Installations:- Single Sided Seals Max. Joint Width Wall Constructions (min 100mm thick) Material 40 20 Polyethylene 30 15 Polyethylene 20 10 Polyethylene 120 60 120 30 120 30 120 30 45 30 40 20 Polyethylene 30 15 30 15 Polyethylene 30 15 20 10 Polyethylene 30 15 45 30 40 20 Polyethylene 45 30 30 15 Polyethylene 45 30 20 10 Polyethylene 120 15 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 6 of 13 Signed

EN 1366-4 Approval Matrix Floor Installations: Single Sided Seals Seal installed flush with upper face of the floor Max. Joint Width Material Floor Constructions (min 150mm thick) 20 10 Polyethylene 240 90 240 45 50 50 Polyethylene 45 45 20 10 Polyethylene 30 30 50 50 Polyethylene 240 90 20 10 Polyethylene 120 120 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 7 of 13 Signed

EN1366-4 Approval Matrix Wall Installations: Double Sided Seals Max. Joint Width Material Wall Constructions (min 120mm thick) Drywall/ autoclaved 20 12.5 Polyethylene 120 120 Wall Constructions (min 100mm thick) 20 12.5 Polyethylene 120 120 grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Sealing of Drywall Head & Flexible Wall To Rigid Wall Double Sided Seals Max. Joint Seal Integrity Width Orientation Wall Constructions (min 120mm thick) Gypsum plasterboard + steel head track/rigid floor Gypsum plasterboard + steel vertical edged track/rigid floor 20 25 20 25 Horizontal 120 120 Vertical 120 120 grease and may need to be primed. On good clean surfaces no priming required. Page 8 of 13 Signed

EN1366-4 +A1 Approval Matrix Max. Joint Width Material Movement % Wall Constructions (min 150mm thick) autoclaved aerated concrete 60 * 20 60* 5 (either face) Polyethylene 20 mm & 50 mm diameter 75mm deep, compressed 15%, stonewool 60kg/m3 240 120 25 Shear 8.3 Lateral 240 60 25 Shear 12.5 Lateral *Pre movement Application Technique grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 9 of 13 Signed

EN1366-4 +A1 Approval Matrix Max. Joint Width Material Movement % Floor Constructions (min 150mm thick) autoclaved aerated concrete 60 * 20 60* 5 (upper face) Polyethylene 20 mm & 50 mm diameter 100mm deep, compressed 15%, stonewool 60kg/m3 180 60 16.6 Lateral 240 240 25 Lateral *Pre movement Application Technique grease and may need to be primed. On good clean, virgin concrete & masonry, no priming required. Page 10 of 13 Signed

EN1366-3 Approval Matrix Wall Installations: Double Sided Seals Pipe Size and Type Annular Seal Width Material Flexible or Rigid Wall Constructions (min 150mm thick) Copper/Steel pipe 15mm dia. & 0.8 7.4mm wall thickness Copper/Steel pipe 40mm dia. & 0.8 14.2mm wall thickness Copper/Steel pipe 40 159mm dia. & 1.8 14.2mm wall thickness Copper/Steel pipe 40mm dia. & 0.8 14.2mm wall thickness with Thermal Defense Wrap 30mm long to the unexposed face. Copper/Steel pipe 40mm dia. & 0.8 14.2mm wall thickness with Thermal Defense Wrap 30mm long to the unexposed face. Rigid Walls Flexible Walls 10 25 10 25 10 25 10 25 10 25 N/A 120 20 N/A 120 15 N/A 120 0 N/A 120 90 N/A 120 20 The hole to be cut to suit the required annular space and the service shall then be positioned centrally within the hole. The annular space shall then be filled to the minimum required depth with the sealant and the sealant smoothed to be flush with both faces. On good clean surfaces no priming is required The wall must have a minimum thickness of 150mm and comprise concrete, or masonry with a minimum deity of 450kg/m³ The walls must have a minimum thickness of 120mm and comprise timber or steel studs lined on both faces with a minimum of 2 layers of 12.5mm thick Type F Gypsum board according to EN 520. In timber stud walls no part of the penetration shall be closer than 100mm to a stud, the cavity must be closed between the penetration seal and the stud and a minimum of 100mm of insulation of Class A1 or A2 according to EN 13501-1 must be provided within the cavity between the penetration and the stud. Page 11 of 13 Signed

EN1366-3 Approval Matrix Wall Installations: Double Sided Seals Cable and Cable Tray Size Cut Out Material Flexible or Rigid Wall Constructions (min 150mm thick) Cables to 21mm Perforated Cable Tray 450mm x 50mm Cables > 21-50mm 490mm long x 100mm high 490mm long x 100mm high 200mm long x 100mm high 25 25 25 70mm x 80kg/m³ stone wool 70mm x 80kg/m³ stone wool 120 90 120 90 N/A 90 60 Rigid Walls Flexible Walls The hole to be cut to suit the required service and the service shall then be positioned centrally within the hole. The space shall then be filled to the minimum required depth with the sealant and the sealant smoothed to be flush with both faces. On good clean surfaces no priming is required. The wall must have a minimum thickness of 150mm and comprise concrete, or masonry with a minimum deity of 450kg/m³ The walls must have a minimum thickness of 120mm and comprise timber or steel studs lined on both faces with a minimum of 2 layers of 12.5mm thick Type F Gypsum board according to EN 520. In timber stud walls no part of the penetration shall be closer than 100mm to a stud, the cavity must be closed between the penetration seal and the stud and a minimum of 100mm of insulation of Class A1 or A2 according to EN 13501-1 must be provided within the cavity between the penetration and the stud. Page 12 of 13 Signed

Approval Matrix Air Permeability: EN1026 Pressure (Pa) Positive pressure (m 3 /h/m 2 ) 50 0 0 100 0 0 Negative pressure (m 3 /h/m 2 Weather Capability: Not evaluated by this approval Acoustic Rating: BS EN ISO 10140-3:1995 R w(c;c tr) :38(-2;-7) db Movement Capability: Movement parameters provided in the scope above Smoke Toxicity BS 6853: 1999 Annex B.1 Incorporating Amendment No.1 R value of 0.19 Smoke Density BS 6853 D.3: 1999 Incorporating Amendment No.1 Ao (max) value 0.004 Page 13 of 13 Signed