G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

Similar documents
HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

SECTION SLUDGE HOLDING TANK DECANTER PUMP

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

SECTION PACKAGE BOOSTER PUMP STATIONS

SUGGESTED SPECIFICATIONS

Series Sump and Sewage Systems

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

SECTION INFLUENT EQUALIZATION TANK PUMPS

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SUGGESTED SPECIFICATIONS Pump Frames through 64132

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

Series description Wilo-Drain STS 40

Weir Specialty Pumps. WEMCO Torque-Flow

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

BUILT FOR WORK THREE-PHASE PUMPS

Goulds Two Stage, Horizontally Split Case Pump

AUGUST 2017 Tulpehocken Station Utility Improvements ADDENDUM 3 SECTION SEWAGE EJECTOR PUMPING STATION

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

Pump Division MSX Solids-Handling, Submersible Pumps

SECTION VI Duplex Lift Station with Above Grade Valve Pit

Simplex Fiberglass Lift Station: Hard Piped

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMP UNITS

MINOR. Electrical submersible drainage pump. Tel Fax Hz. No: PD603-EN. Revision

NUCLEAR POWER CORPORATION OF INDIA LTD TECHNICAL SPECIFICATION ON SUBMERSIBLE PUMPS PAGE NO: 1 OF 4 REV NO : 0 DATA SHEET A

COMMERCIAL ITEM DESCRIPTION PUMP ASSEMBLIES, DEEP-WELL, ELECTRIC-MOTOR-DRIVEN

N-pump, Standard Motor

Experience In Motion MPT. Self-Priming, Solids-Handling Pump

Technical specification. Flygt N 3301, 50 Hz

MODELS PH PH PH

INSTALLATION INSTRUCTIONS

D-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

TECHNICAL HANDBOOK. ASME B73.1 Process Pump. Wilfley Sealing Technology. No Flush Water Required

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011.

Introduction. Ultra Reliable

Close Coupled Sump Pumps Type ETLB

PNI RESIN MADE PUMPS

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

EC medium pressure axial fans.

Experience In Motion. TKL Primo-Titan Self-Priming, Solids-Handling Pump

Experience In Motion. MPT Self-Priming, Solids-Handling Pump

TYPE 37FS Fully Split Seal

Flygt 3171, 50Hz. Technical Specification

Submersible Pump Fulfills Quarry Stone Washing Requirements. By Mike Bjorkman, Vice President and Director of Marketing, BJM Corp.

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

Dredging Mining Industry. Sand and Gravel Dredging equipments and Industrial Pumps

Flygt 3057, 50Hz. Technical Specification

Autogas Series. Regenerative Turbine Coro-Flo Pumps For High Differential Pressure Applications Using LPG and Other Liquefied Gases.

Technical specification. Flygt N 3127, 50 Hz

Autogas Series. Regenerative Turbine Coro-Flo Pumps. For LPG High Differential Pressure Applications

SECTION COOLING TOWER

Module 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations

Model EVMS Vertical Multistage Pumps for the Global Market

Submittal for Aquatherm Piping System

In-line Twin Pump. Type Series Booklet. Omega DSL

FYBROC SERIES 5500 FIBERGLASS CONSTRUCTION FOR CORROSIVE APPLICATIONS. Fybroc Vertical Fiberglass Sump Pumps B U L L E T I N 5 5 B 1

SECTION SANITARY WASTE INTERCEPTORS

VOGEL - Submersible Pumps in Stainless Steel Design TVS

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Introduction. Disclaimer. Table of contents

Pioneer Forced Draft Cooling Tower Specifications

Experior as an Energy Savings Solution for Wastewater Lift Stations. Lisa Riles NA Marketing and Business Development Manager Xylem

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Amarex KRT. Waste Water. Waste Water Submersible Motor Pump. Submersible Motor Pump. 4 Amarex KRT

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

Introduction. Ultra Reliable

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

BRUSHES WITH SHANK 62 63

Flygt 3057, 50Hz. Technical Specification

CIVIL/INDUSTRIAL. water solutions. Grey. series SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE, CIVIL AND INDUSTRIAL LIFTING SYSTEMS. zenit.

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

Flygt C-pumps Submersible waste and raw water pumps

Wet & Dry Size Reduction

ISSUE DATE JANUARY 1st, 2008 SECTION 5G FIBERGLASS PACKAGE LIFT STATION

INSTALLATION INSTRUCTIONS. MODEL Version W SUBMERSIBLE SUMP PUMP

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

Town of Fortville Utility Street Standards

Engineering Data Pack HD Industrial Duty Pumps

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Fiberglass Cooling Towers

ERPN Overhung, End-Suction Process Pump ISO 13709/API 610 (OH2)

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.

SECTION DOWNSTREAM DEFENDER

PDF / 75 HP SUBMERSIBLE PUMP DOCUMENT

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

Industrial/Commercial Sump Pumps

SKF Agri Solutions Adding value at every stage of the crop cycle

ABRASION resistant ACID resistant

Transcription:

100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the Best Efficiency Point. Operating at the outer limits of the curve is not recommended. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH: 0 10 20 30 40 50 60 Flow Rate (GPM) 70 80 90 G2D Series Performance Data Wholesale Products Page: JP10075SSD-1 Section: Performance Data

B A C D F E Model A B C D E F Weight mm in mm in mm in mm in mm in mm in kg lb G2D-01 4.84 417 16.42 247 9.72 123 G2D-21 4.84 254.5 10.02 141 5.55 387 15.24 38.1 84 G2D-03 G2D-23 378.4 14.9 221.9 8.73 103 4.06 217.1 8.55 136.5 5.37 349.5 13.76 29 64 G2D-43 Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purposes unless certified. Dimensions and weights are approximate. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice. G2D Series Dimensional Data Wholesale Products Page: JP10075SSD-2 Section: Dimensional Data

MODEL: G2D Series Grinder Pumps Model Units G2D-01 G2D-03 G2D-21 G2D-23 G2D-43 Motor type E 90-2/110 H D 71-2/105 G E 90-2/110 H D 71-2/105 I D 71-2/105 H Frequency Hz 60 Voltage / tolerance V 1ø ~200V 3ø ~200V 1ø ~230V 3ø ~230V F.L.A. A 13.8 8.6 12 7.3 3.7 R.P.M. 1/min 3330 3150 3330 3150 3200 cos phi 0.98 0.87 0.98 0.89 0.88 cos phi-start 0.85 0.81 0.85 0.81 Maximum ON/OFF cycles per hour 1/h 60 Start Amp. (at H=3 ft and rated voltage) 35 34 40 26 17.4 ISO-class Enclosure IP 68 Winding protection / control unit required Ext. motor protection required F 150 C Therm. / Yes Winding resistance Ohm 1.4 2.7 1.4 4.4 Service Factor 1.43 1.05 1.43 1.05 Standard Cable 25 ft SOOW 12/6 AWG 12 Yes 3ø ~460V G2D Series Electrical Data Wholesale Products Page: JP10075SSD-3 Section: Electrical Data

MODEL: G2D Series Grinder Pumps Units G2D-01 G2D-03 G2D-21 G2D-23 G2D-43 Max. head ft 82 85 82 85 Max. flow rate GPM 75 79 75 79 Torque LRT/FLT/POT lb/ft 2.4 / 4.8 / 7.7 10.8 / 3.5 / 11.1 2.7 / 5.5 / 8.7 10.8 / 3.5 / 11.1 Bearing n.d.e. 6204 2Z ball 6202 2Z ball 6204 2Z ball 6202 2Z ball Bearing d.e. 3205 2rhg. angular contact ball 3203 2rhg. angular contact ball 3205 2rhg. angular contact ball O-rings NBR 70 DIN 3771 Shaft seal motor side mm 2 x 25 x 38 x 7 lip seal Shaft seal medium side mm 25 x 24 SiC mech. seal Volute type / material Discharge connection 2 x 16 x 28 x 7 lip seal 16 x 18.8 SiC mech. seal 2 x 25 x 38 x 7 lip seal 25 x 24 SiC mech. seal M / GG-25 cast iron Thread 1-1/4 NPT Cutter Plate Inlets x diameter in 8 x Ø.315 Impeller type / material open radial / GG-25 cast iron 3203 2rhg. angular contact ball 2 x 16 x 28 x 7 lip seal 16 x 18.8 SiC mech. seal Impeller diameter in Ø 5.118 Ø 5.315 Ø 5.118 Ø 5.315 Vane qty / height in 5 / 0.236 Free passage in 0.276 Total inertia lb ft 2 0.095 0.071 0.095 0.071 Oil chamber qty / SAE 5W-15W in 3 (ISO 22-44) Mineral oil 45.8 23.2 45.8 23.2 Materials of Construction Coating 2K Epoxy, 80 μm, black Motor casing GG-20 cast iron Bearing chamber GG-25 cast iron GG-20 cast iron GG-25 cast iron GG-20 cast iron Pump shaft C 45 K covered 42CrMoS 4 covered C 45 K covered 42CrMoS 4 covered Cutter 440, 57 HRC SS Cutter plate G2D Series Technical Data Wholesale Products Page: JP10075SSD-4 Section: Technical Data

MODEL: G2D Series Grinder Pumps 1.01 General Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal grinder sewage pump(s) as specified herein. The pump models covered in this specification are the G2D Series pumps. The pump furnished for this application shall be MODEL as manufactured by Jung Pumpen of Delavan, Wisconsin (800-642-5930). 2.01 Design Conditions Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. The pump shall deliver U.S. GPM/LPS at feet/meters TDH., and pass a inch solid. The reserve service factor shall be a minimum of. The specification submitted for approval shall state, in addition to flow and head capacity performance, solids handling capability, amp rating, and design impeller diameter. 3.01 Construction Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the heavy duty industrial or municipal markets. These features include: 3.02 The castings shall be constructed of epoxy coated cast iron. 3.03 The seal housing for the pump is cast iron. 3.04 The pump inlet shall be open and clear, without screening to provide access for sewage and solids. 3.05 All external mating parts shall be machined and Buna N, O-Ring sealed. 3.06 All fasteners exposed to the pumped liquid shall be 300 series stainless steel. As an optional feature include seal leak probes in the seal chamber. 4.01 Electrical Power Cord All power cords shall be SO-type water resistant UL or CSA approved, with double insulation, and sized as a function of Full Amp. draw. 5.01 Motor The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be split phase or capacitor start with centrifugal switch. Three phase motors shall be Polyphase. Full Load and Locked Rotor Amps. as well as Start and Run winding resistance shall be tabulated for each pump. 6.01 Bearings, Shaft And Mechanical Seal An upper radial ball bearing and a lower double row angular contact ball bearing shall be required. The motor shaft shall be stainless steel and sealed from the pumped liquid with a silicone carbide mechanical seal and two lip seals. 7.01 Impeller The impeller shall be a high capacity five vane design with pump out vanes on the back side. These vanes wash out grit and stringy material that will damage the shaft and mechanical seal. G2D Series Specification Data Wholesale Products Page: JP10075SSD-5 Section: Specification Data

8.01 Control All single phase pumps should be capable of automatic operation. 8.02 Pressure Switch - The Single Phase pumps are furnished with a pressure diaphragm switch that features a piggy-back plug that allows the pump to be operated manually without removal from the sump. 8.03 Float Switch - The Single Phase pump is supplied with a tilt-sensitive wide-angle float switch is sealed in a non-corrosive PVC enclosure. The unit is UL listed for water and sewage and CSA certified. The float switch shall also be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 8.04 Manual Control - The Single Phase pumps are not supplied with any type of automatic control. A super or double wide angle piggy-back float switch can be supplied and fitted to these pumps. 9.01 Cutter Mechanism The cutter and cutter plate shall consist of 440 stainless steel with a Rockwell C hardness of 55-60. The cutter plate shall have 8 oval holes that allow for the slurry to flow into the pump. The cutter shall have 3 blades designed to closely pass over the holes in the cutter plate to cut up the material into a fine slurry. The design shall not be considered equal to ring or radial cutters. 10.01 Painting All cast iron parts shall be painted before assembly with a black high solids epoxy mastic and applied in one coat with a minimum thickness of 8 mils. 11.01 Serviceability Components required for the repair of the pump shall be readily available within 24 hours. Components such as mechanical seals and bearings shall not be of a proprietary design and be available from local industrial supply houses. Special tools shall not be required to service the pump. A network of service stations shall be available nationwide in those cases where service requirements are beyond the scope of in-house service mechanics. 12.0 Support Optional support legs are available, enabling pump to be a freestanding unit. The legs will be high enough to allow passage of solid matter below the housing. 13.01 Testing All pumps shall be individually tested to include the following: 13.02 The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 13.03 The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects. 13.04 The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 13.05 Oil is added by the tester and the pump is run. Voltage and current are monitored visually and electronically while the tester listens for any noise or malfunction. 14.01 Warranty Standard warranty shall be 12 months from date of installation or 18 months from date of manufacture. Warranty repairs shall be provided by an authorized service station. G2D Series Specification Data Wholesale Products Page: JP10075SSD-6 Section: Specification Data