application instructions

Similar documents
General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

LP SmartSide Perfection Shingle

Gold Bond BRAND Gypsum Sheathing

Joint Evaluation Report ICC-ES (800) (562)

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Siding and Soffit Installation Guidelines

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

SPECIFICATION GUIDELINE

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Pacific Tile Counter Batten and Batten

DuPont RainVent Batten Installation Guidelines

Vertigo Cladding Board

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

DuPont. Tyvek Sheathing Membrane Installation Guidelines. Version 2. Canadian Version

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

HPW Protocol Reference Manual

INSTALLATION GUIDE.

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

SPECIFICATION GUIDELINE

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

The GlasRoc Shaftliner Type X advantage...

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

A. Source Limitations: Obtain each type of building insulation through one source.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Senturion TM III Wall System

WATERPROOFING TAMKOWATERPROOFING.COM

ELEVATION FOR DETAIL REFERENCE ONLY

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

STORAGE AND TRANSPORTION

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

ALLMET CONTINENTAL INSTALLATION GUIDE

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

Vertical Siding. With a Minimum 12-inch Eave Overhang. Vertical Joints formed by Expressed Seam Joints

for New Construction Applications

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

STUCCO FAILURES and REMEDIATION Roger G. Morse AIA

PLYWOOD FLOATING FLOOR

BUILDING SUCCESSFULLY WITH DRYVIT RESIDENTIAL SYSTEMS.

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

ELEVATION FOR DETAIL REFERENCE ONLY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Rainscreen Gaps in Exterior Walls

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

LUX Specifications. Section S - Preformed Steel Siding

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

Henry Blueskin VP160 Air Barrier System Installation Manual

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

138 H-STUD AREA SEPARATION WALL SYSTEM

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

Exterior Siding System Installation Guidelines

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

BEARING METAL STUD FRAMING

NEXT GENERATION HIGH PERFORMANCE WALLS

Common Applications: FRT plywood Type X Gypsum wall board

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

Installation Guide Wall Panels

LP OSB Sheathing & Structural 1 Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

(Project Location) (your firm's name)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

Exterior Stucco and Siding Installation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

SECTION GYPSUM BOARD ASSEMBLIES

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION PRE-ENGINEERED BUILDING INSULATION

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

Floor Insulation Underlayment Section Sound Control Matting

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

ELEVATION FOR DETAIL REFERENCE ONLY

Introducing TJ Insulated Structural Framing Components

2006 INTERNATIONAL ENERGY CONSERVATION CODE

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: AMERICAN EAGLE MATERIALS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

A Simple Solution for Meeting

ENKASONIC FLOOR UNDERLAYMENT 9110

Transcription:

application instructions FOUNDATIONS 76 & 120 SERIES PRIMED PANEL SIDING ARCHITECTURAL COLLECTION REVERSE BOARD & BATTEN AND STUCCO PANEL SIDING General At the time of manufacture, siding meets or exceeds the performance standards set forth in Composite Panel Association ANSI 135.6 and has achieved code recognition under Legacy National Evaluation Report NER-626 and CCMC 12353. For copies of these reports, call LP Customer Support at 1-800-648-6893. Minimum 6 in. clearance must be maintained between siding and finish grade. Siding applied adjacent to porches, patios, walks, etc. must have a clearance of at least 1 in. above any surface. Minimum 1" clearance at intersection with roof line Apply siding in a manner that prevents moisture intrusion and water buildup. All exposed wood substrate must be sealed in a manner that prevents moisture intrusion and water buildup. In non-traditional ICF and SIP assemblies, the ICF or SIP manufacturer must prescribe the fastening specifications. Note: LP does not recommend LP SmartSide for use in these non-traditional assemblies. If used, LP will not warrant for Buckling and Shrinkage. However, balance of warranty does remain intact. DO NOT USE STAPLES SIDING MUST NOT BE IN DIRECT CONTACT WITH MASONRY, CONCRETE, BRICK, STONE, STUCCO OR MORTAR. Storage Store off the ground well supported, on a flat surface, under a roof or separate waterproof covering Keep siding clean and dry. Inspect prior to application. Stud Spacing Foundations 76 Series soffit may be installed as panel siding ONLY if the LP Product Description includes Foundations Soffit. Please verify any soffit product selection for use as a siding with your local supplier before purchase or installation. Do not exceed 16 in. O.C. framing spans and fasten with maximum 6 in. perimeter spacing and 12 in. spacing in the field of the panel. Apply the panel per the complete specifications of this document. A minimum 3/16 in. gap is required at all vertical joints of square edged panel siding. If square edged panel siding is installed with battens over vertical seams, caulking is NOT required at vertical seams. If square edged panel siding is installed without battens, the vertical joint must be caulked with a minimum ASTM C920 Class 25 sealant. Siding may be applied over sheathed walls or, where building codes permit, directly to studs spaced no greater than 16 in. O.C. that have adequate corner bracing. In all installations over masonry or concrete walls, the wall shall be furred out and open at the top and bottom of the wall to allow for convective ventilation between framing spaced 16 in. O.C. The framing shall be of adequate thickness to accept 1-1/2 inches of nail penetration. A properly installed breathable water-resistant barrier is required between the siding and masonry or concrete walls. Foundations 76 Series and Architectural Collection 76 series reverse board & batten and stucco panel siding is not warranted against buckling in Alaska, Hawaii, Northern California or west of the Cascades in Washington, Oregon and California. Moisture Moisture control and water vapor control are critical elements of proper housing design. Check your local building codes for application procedures for handling moisture and water vapor in your area. When using wet blown cellulose insulation, the insulation must not be in direct contact with the siding and it must be allowed to dry a minimum of 24 hours or longer if specified by the insulation manufacturer. As with all wood products, do not apply engineered wood siding to a structure having excessive moisture conditions such as drying concrete, plaster or wet blown cellulose insulation. If such conditions exist, the building should be well ventilated to allow it to dry prior to the application of the siding. Siding must not be applied to green or crooked structural framing members. Do not apply siding over rain-soaked or buckled sheathing materials. Gutters are recommended for control of roof water run off. Secondary Water -Resistant Barrier A properly installed breathable water-resistive barrier is required behind the siding. Consult your local building code for details. LP will assume no responsibility for water penetration. Gaps & Sealants Seal all gaps with a high-quality, non-hardening, paintable sealant. Follow the sealant manufacturer s instructions for application. Use a high-quality exterior sealant meeting the ASTM C920, minimum Class 25 sealant. Flashing, Windows, Doors & Openings All openings must be properly sealed or flashed in a manner that prevents moisture intrusion or buildup. Several examples that accomplish this are shown on the following pages.

Application instructions (cont.) Kick-Out Flashing Install kick-out flashing to direct the water into the gutter Install step flashing with minimum 4 in. upper leg Properly integrate flashing with the secondary water-resistive barrier. Use housewrap, flashing tape, z-flashing, or other items as needed to maintain the counterflashing principle. DO NOT extend the siding or trim into the kick-out flashing or gutter Maintain a clearance between the end of the gutter and the adjoining wall to allow for proper maintenance of the siding Prime and paint ALL exposed cut edges LP Siding Minimum 1" clearance between trim and roofing Finishing Instructions DO Prime and paint all exposed surfaces including all drip edges or where water will hang. Apply finish coat as soon as possible or within 180 days of application. High-quality acrylic latex paint, specially formulated for use on wood and engineered wood substrates, is highly recommended. Semi-gloss or satin finish oil or alkyd paints are acceptable. For flat alkyd paint, please check with the coating manufacturer for their recommendations for use on composite wood siding. Follow the coating manufacturer s application and maintenance instructions. DO NOT USE Semi-transparent and transparent stains. Shake and shingle paints. Vinyl-based resin formulas such as vinyl acetate, PVA, vinyl acetate/acrylic copolymer paints. HANDLE PREFINISHED LP SMARTSIDE PRODUCTS WITH EXTREME CARE DURING STORAGE AND APPLICATION. TOUCH UP ANY DAMAGE TO THE FINISH THAT MAY OCCUR DURING APPLICATION PER PREFINISHERS SPECIFICATIONS. Nailing Instructions Apply siding over framing with a maximum stud spacing of 16 in. O.C. Clean rain gutter Do not run trim or siding inside of the kick out flashing All siding must be installed over framing members no less than 2 in. x 4 in. Shiplap edges must fall on studs. Position underlap shiplap flange at center of stud. Horizontal joints must be supported by framing. Leave a 3/8 in. gap and flash joints with a noncorrosive Z flashing. Where panels butt against window and door trim and at inside and outside corners, leave a 3/16 in. gap and caulk. Trim Penetrate structural framing or wood structural panels and structural framing a minimum of 1-1/2 in. Trim should be thick enough so the siding does not extend beyond the face of the trim. Trim and fascia must be applied in a manner that will not allow moisture intrusion or water buildup. LP SmartSide siding is not designed and/or manufactured to be used as trim or fascia. LP SmartSide trim and fascia are available in a variety of dimensions. CONDITION Snug Flush Visible fiber Countersunk 1 /16 1 /8 in. Countersunk more than 1 /8 in. CORRECTION OK OK Paint Apply sealant Apply sealant and re-nail

Nailing Instructions (cont.) DOUBLE NAILING AT VERTICAL JOINTS IS REQUIRED. (See Figure 2E) Space nails 6 in. O.C. on all siding edges and 12 in. O.C. at intermediate framing members. Nails spaced 6 in. O.C. on underlap flange will be covered by overlap flange. Nails spaced 6 in. O.C. on overlap flange should be 1 in. in from edge of panel. Climb cut the surface of the siding such that the rotation of the blade cuts downward on the primed or prefinished surface. Where siding butts window trim, door casings and masonry, etc. leave a 3/16 in. gap and seal. For information on fastening LP SmartSide products in high wind speed areas, refer to ICC-ES Report ESR-1301 or APA Product Report PR-N124. Insulated Sheathings LP SmartSide Sidings may be installed over low-compression rigid foam or exterior gypsum. The following precautions must be followed: Adequate bracing of the wall in accordance with the International Codes or other ruling building code is required. For rigid foam sheathing up to 1 in. (25.4 mm) thick, siding may be nailed directly to the foam sheathing unless a drainage plane is required by the local building code. Nail length must be in-creased to ensure a minimum 1-1/2 in. (38.1 mm) fastener penetration into the structural framing. LP panel sidings are accepted by the State of California as category 8140- Exterior wall siding and sheathing for Wildland Urban Interface (WUI) applications. For WUI compliance, install LP panel sidings in accordance with Louisiana-Pacific s printed installation instructions with the addition of fire retardant seal (UL Listed fire caulk, nominal ¼ bead) in the vertical joint and nailing pattern of 3 OC perimeter nailing/8 OC field nailing. Look for the California State Fire Marshal Office label on our siding. The Louisiana-Pacific Corporation ( LP ) LP SmartSide Siding (the Products ) limited warranty (the Warranty ) applies only to structures on which the Products have been applied, finished and maintained in accordance with the published application, finishing and maintenance instructions in effect at the time of application. The failure to follow such application, finishing or maintenance instructions will void the Warranty as to the portion of the Products affected by the variance (the Affected Products ). LP assumes no liability for any loss or damage sustained by the Affected Products and is expressly released by the purchaser or owner from any such loss or liability. Any modification of the Warranty s application, finishing or maintenance requirements is void and unenforceable unless approved in writing prior to application by the Siding General Manager or his designee and a member of the LP Legal Department. For a copy of the warranty or for installation and technical support, visit the LP SmartSide product support Web site at: www.lpsmartside.com or for additional support call 800-450-6106. WARRANTY REMEDIES ARE NOT AVAILABLE IF REQUIREMENTS ARE NOT FOLLOWED. For rigid foam sheathing greater than 1 in. (25.4 mm), a minimum 1-1/2 in. (38.1 mm) thick by 3-1/2 in. (88.9 mm) wide vertical strapping or furring strip must be installed over the sheathing to provide a solid, level nailing base for the siding. The strapping must be securely fastened to structural framing spaced no greater than 16 in. O.C. (406 mm) with a minimum nail penetration of 1-1/2 in. (38.1 mm) and a maximum nail spacing no greater than the width of the siding. Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of rigid foam or exterior gypsum. Cal. Prop 65 Warning: Use of this product may result in exposure to wood dust, known to the State of California to cause cancer. 2014 Louisiana-Pacific Corporation. All rights reserved. LP and SmartSide are registered trademarks of Louisiana-Pacific Corporation. Printed in U.S.A. NOTE: Louisiana-Pacific Corporation periodically updates and revises its product information. To verify that this version is current, call 800-450-6106. LPZB0511 1/14

over openings alternate panel stacking details ensure complete paint coverage of the drip edge ensure complete paint coverage of the drip edge ensure complete paint coverage of the drip edge Figure 1A Figure 1B Figure 1C Figure 1 Shiplap Panel Siding gap 3/16 in. and seal gap 3/16 in. Figure 1E outside corner details Figure 1D

Roof Flashing Detail Trim Gap 3/ 16 in. and seal Gap 3/ 16 in. and seal 4 in. min. vertical flashing 1 in. min. clearance from roofing Paint bottom edges Figure 2A Figure 2B Figure 2C vapor retarder if required by code Breathable water-resistant barrier 6 in. 12 in. Figure 1 Shiplap Edge Panel Figure 2F Figure 2E Figure 2D 1 in. 3/8 in. 6 in. minimum Bottom Course Detail Panel Joint Ground Clearance