Air Infiltration & the Knauf Insulation EcoSeal

Similar documents
Air Infiltration & Insulation

Knauf Insulation & Sealing System Q&A

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Knauf Makes It Easy to Insulate

2013 COMMERCIAL PRODUCTS

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Cellulose Insulation Products. Date: Submitted to: Submitted by: Job Reference: Job Name

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Inspection of New One- and Two- Family Dwellings

Low-cost Construction for High-energy Savings. Brian J. Wimmer Construction Manager Rochester Area Habitat for Humanity

2

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Prescriptive Checklist for the 2015 Washington State Energy Code

HOW TO BUILD AN ENVIRONMENTALLY RESPONSIBLE HOME

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES;

Feature Zone IECC 2009 IECC

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

EcoTouch Insulation with PureFiber Technology

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Michigan Energy Code Training and Implementation Program

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Air Sealing Opportunities in New Construction

Continuous Insulation Systems for Exterior Walls

Chapter 2: Foundation

Guidelines for Measures & Strategies Wall Air Sealing & Insulation Methods in Existing Homes

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Michigan Energy Code Training and Implementation Program

Integrated Air & Water Barrier Systems

Energy equivalent R-value

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

This page has been left blank intentionally.

Attic Insulation. Student Guide

2015 IECC Whole Building Air Leakage Compliance

RETROFIT INSULATION in WOOD ROOFS

COLD CLIMATE HOUSING RESEARCH CENTER CCHRC. Whole Wall R-Values

Construction Report NYSERDA Residential Performance Challenge

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Crawl Space Moisture Control

2006 INTERNATIONAL ENERGY CONSERVATION CODE

HPW Protocol Reference Manual

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

ASHRAE 62.2: What s New in 2016

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

QCI HEP Pre Exam Quiz

Residential Building Inspections

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Energy Conservation & Building Envelope. Objectives. Introduction. Determine the Building Envelope of a House Calculate Heat Loss of a Building

Boulder City NV Prepared by (Print Name) Signature Date

Questar ThermWise Duct Technical Specifications

A home isn t complete until it s

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Plan Check & Field Inspection Guide

Energy-efficient weatherization

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

The REMOTE Wall System

Eclipse Air Duct Board

Container Installation Guide

Thermal Bridging in Residential Construction

2010 National Building Code Adoption and Associated Process Changes

WINE CELLAR PROPOSAL WINE RACKS AMERICA

Hardin County Planning and Development Commission

Moisture Considerations for Insulated Building Assemblies

L77 INSULATION THAT WORKS AS HARD AS YOU DO PRO PROPINK INTRODUCING

10 Steps to Save Energy in Your House

Residential Product Selector Guide

When R-Value Doesn t Measure Up

Top plates. Stud. Pre cut stud. 8 ft, 1 1/8 inch. 4 inch brick veneer ½ inch plywood sheathing. Insulation placed between the studs

Closed-Cell Spray Foam Insulation. Performance in Residential and Commercial Buildings During Adverse Weather

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

2012 CLEAResult All rights reserved. Residential Energy Efficiency

REPORT ON COMPARATIVE AIR LEAKAGE PERFORMANCE:

How do you install yours?

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

United States Army Corp of Engineers Requirements for Air Barrier Systems in Buildings

Panelize Your Dreams. With Enercept, The Better Way To Build. Structural Insulated Panels The Builders Choice

Retrofit Installer / Shell

Open and Closed Cell Spray Foam Insulation

2012 IECC Residential with State Adopted Changes

CertainTeed OPTIMA. Installation Instruction Manual

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Slab edge insulation is one of

Cathedral Ceiling Applications

California Building Envelope Solutions

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Transcription:

White Paper BI-WP-04 10-12 Air Infiltration & the Knauf Insulation EcoSeal System EcoSeal & Knauf Insulation Glasswool Products AN WHITE PAPER

THE IMPACT OF OTHER BUILDING ELEMENTS ON AIR INFILTRATION Consider the following example: Good quality windows could have an air leakage of 0.25 cfm/ square foot of window area. Doors with weatherstripping will typically leak 0.18 cfm/sf. If you assume a fenestration percentage of 20% and a door area of 10% for a wall, the resultants leakage would be:.00225 *.7 = 0.0016 cfm for the wall,.25 x.2 = 0.05 cfm for the windows and.1 x.18 = 0.018 cfm for the door. Therefore, the leakage contribution of the wall with Ecoseal is 0.0016/ (0.0016+.05+.018) = 0.023. This means that the sealed wall is only contributing 2.3% of the total leakage of this wall. In reality, walls and ceilings ususally have many other penetrations and construction complexities. Most of these can also be sealed effectively with EcoSeal. These results show that the combination of EcoSeal with Knauf Insulation fiber glass products can provide air leakage numbers essentially the same as those achieved by spray applied foams. The advantage of the EcoSeal system is that it can provide higher R-values than either light density foam or cellulose and outstanding leakage resistance. When combined with Knauf Insulation fiber glass insulations, it offers a very cost competitive solution for energy efficiency. It is important to account for the indoor air quality affects that might come with tight envelope sealing. Traditionally, U.S. homes have relied on natural air leakage to provide sufficient fresh air to dilute pollutants within the living space. Older homes have been measured to have typical ventilation rates of 0.5 to 1.0 air changes per hour (ach); some homes have been measured as high as 2 ach. Tightly sealed homes may achieve leak rates as low as 0.1 air changes per hour, with 0.25 ACH being typical. The proper use of EcoSeal can easily provide structures with air infiltration rates of 0.25 ACH or less. While this can represent significant energy cost savings to the homeowner, the lack of fresh air could cause health issues to the occupants. For these tightly sealed homes, mechanical ventilation must be designed into the home to introduce fresh air in the most energy efficient manner. ASHRAE Standard 62.2 and the BPI Standards both provide guidance on minimum fresh air requirements for residential buildings. Knauf Insulation highly recommends that these Standards be followed whenever energy efficient new home designs or existing home retrofits are contemplated.

Air Infiltration & the Knauf Insulation EcoSeal System Most homes are ventilated by natural air leakage. This leakage may play an important role in determining the air quality of the home. However, uncontrolled air leakage can often carry a significant energy penalty due to excessively cold or warm and moist air and its impact on heating and cooling loads. Uncontrolled air leakage can also bring in excessively dusty or contaminated air depending on the surroundings for the home. Air leakage can account for as much as 40% of annual heating and cooling costs. Air leakage can also cause drafts within the living space or allow the ingress of excessive moisture into the building structure. Air leaks into and out of buildings through penetrations of all types. Some are clearly visible, some are not. Some are intentional, like exhaust vents, some are not. Air leakage most often occurs at joints between building materials. Irregularities in the building s exterior, such as protrusions and penetrations, are often leakage points because they often involve multiple joints. These areas pose air sealing difficulties and deserve special attention whether the project is an energy retrofit or new construction. In new construction, air leakage can be significantly reduced by the use of continuous air barriers, carefully installed and completely sealed on the exterior building shell. Most older homes do not have any air barrier installed. Testing has shown that a very well installed exterior air barrier material is sufficient for achieving air tight homes in new construction. However, in today s construction market, this careful installation is very seldom achieved. Additionally, other building trades often make penetrations to the exterior shell that often negate even the most careful installations of exterior air barriers. Once the exterior barrier has been compromised, it is up to the individual components of the construction to offer air flow resistance against leakage. This resistance is typically measured using a constant air pressure, 50 Pascals (0.2 water column) to determine air flow in cubic feet per minute (cfm). The following chart is based on research conducted by the Canada Mortage Housing Corporation. Air Leakage Through Construction Materials Material Air Leakage (cfm/100 ft 2 at 50 Pascals) ⅝" oriented strand board 0.09 ½" drywall 0.26 4-mil air barrier paper 0.26 ⅛" hardboard 0.37 1" EPS (dense) 1.50 15# perforated asphalt felt 5.30 Standard concrete felt 7.90 1" EPS (light) 170 ⅝" tongue and groove boards 300 6" glasswool batt 490 3" vermiculite 930 With reference to the chart above, materials with air leakage characteristics greater than 2 would not be considered effective air barriers. If one were to use the example of a 2048 square foot home with 8 foot ceiling (32 x 64 foot print), the volume within the conditioned space would be 16,384 cubic feet. If the home were sheathed with wood siding over 65% of its surface area (~1000 sf) and there was no other air barrier, the total leakage through the tongue and groove would be 1000 x 300 = 300,000 cfm or nearly 1100 air changes per hour at 50 Pascals! With a 4-mil air barrier paper and the same assumptions, the infiltration rate through the paper barrier would be ~1 air change per hour at 50 Pascals. There are some materials that test higher than others for absolute air flow resistance, but the differences between effective air barriers are generally insignificant when compared to other building elements such as doors and windows, chimneys and vents, clothes dryers and the need for makeup ventilation. When considering construction materials and techniques that would minimize uncontrolled leakage, it s also important to remember that some level of fresh air is required to maintain acceptable indoor air quality. Small uncontrolled leakage points are often difficult to find and generally not cost justified in the larger scope of an air sealing project.

When providing energy efficient retrofits to existing buildings, it is generally neither feasible nor practical to install new exterior air infiltration barrier materials. The practitioner will seal the obvious and accessible penetrations in the attic and floors and then treat the less accessible leaks in the walls with a variety of methods. It is very common to let densely packed insulation provide both the thermal resistance as well as the air infiltration resistance. In energy retrofits of walls, dense packed cellulose with density of up to 4 pounds per cubic foot (pcf) has gained favor because it is perceived to provide superior air flow resistance when blown into walls. Many weatherization traditionalists believe that dense packed cellulose is the best solution to insulate and improve air infiltration resistance. On the contrary, densely packed glass fiber can provide superior air flow resistance with approximately half the weight. Cellulose and fiber glass are both fibrous materials. The ability of fibrous materials to resist air flow is directly related to the tortuosity of the path air must travel to pass through the fibrous matrix. Tortuosity is directly related to fiber diameter and number of fibers per given volume of insulation.the average fiber diameter of fibrous glass is many times smaller than the average diameter of random and coarse cellulosic fiber. This leads to a significantly more tortuous path for air flow at roughly equivalent installed densities. Knauf Insulation had tests conducted by Intertek Laboratories to measure the air flow resistance of the Knauf Insulation retrofit and weatherization product, EcoFill Wx, over a range of densities between 1.8 and 2.5 pcf. The typical density attained during sidewall retrofits installations of EcoFill Wx is 2.2 pcf. We also had 3 national brands of cellulose insulation tested over a range of installed densities ranging from 3.3 to 4.5 pcf. The following chart summarizes these results. Air Infiltration: Knauf Insulation Premium Blowing Wool vs. Cellulose Air Flow Resistance, (Pascal) seconds per cubic meter 4,500,000 4,000,000 3,500,000 3,000,000 2,500,000 2,000,000 1,500,000 1,000,000 500,000 EcoFill Wx Cellulose 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 2.2 Density, pounds per cubic foot Ecofill Wx Cellulose A Cellulose B Cellulose C The chart graphically illustrates that EcoFill Wx, when installed at a typical retrofit wall insulation density of 2.2 pcf, has as much air flow resistance as dense packed cellulose of densities ranging from 4.2 to 4.7 pcf. Many of the national weatherization training organizations state that cellulose is an effective barrier at installed densities of 3.5 pcf or greater. This testing shows that EcoFill Wx is approximately 2.5 times more effective than cellulose at this minimum performance level. The cellulose manufacturers continue to compare their dense pack against fiber glass batts for retrofit. This is clearly a misleading comparison when considering sidewalls.

Knauf Insulation recognizes that there is still a significant need for effective air sealing in both old and new construction. We also recognize that dense packed fiber glass by itself may not be sufficiently effective as a leakage barrier for highly efficient new construction, or cost effective as an air barrier for all retrofit applications. For this reason, Knauf Insulation has developed a sealant and insulation package known as EcoSeal System, which provides a very cost effective means to achieve highly energy efficient building envelope constructions. EcoSeal System combines a water based elastomeric sealant known as EcoSeal with our environmentally friendly EcoBatts or our premium blowing wool insulations, JetStream and EcoFill TM Wx. Knauf Insulation had the EcoSeal System tested for air sealing characteristics at the NAHB Research Center. Test walls were constructed using 2x4 framing at 16 on centers that measured 8 high by 10 long. There was a single bottom plate and a double top plate in the assemblies. One interior electrical box was included and the wiring was run through each stud for the entire length of the wall at the height of the box. The wall was insulated with inset stapled R-13 fiber glass kraft faced batt insulation. The interior side was covered with ½ drywall and the seams were taped with one coat of tape joint compound. The exterior was sheathed with 7/16 OSB with a horizontal gap running the length of the wall. Tests were run with a base wall containing neither air barrier or sealant, with air barrier taped and untaped, and with air barrier and Ecoseal. All tests were conducted per ASTM E283 and the results can be summarized in the table below. These results show that a picture frame application of EcoSeal without house wrap can reduce air leakage to the same level as taped house wrap. Using EcoSeal in combination with taped house wrap resulted in a leakage reduction of 98% as compare to the unsealed base wall case. A leakage of 0.18 cfm over 80 square feet yields an air leakage factor of 0.00225 cfm/sf. It is important to note that this was a wall construction with no windows or other typical construction elements but it does dramatically illustrate the ability of EcoSeal to yield very air tight structures. Leakage Testing at 50 Pascals CFM per 80 Square Feet of Wall Construction No EcoSeal EcoSeal on Horizontal Seams EcoSeal applied in "Picture Frame" Base Wall 9.73 CFM 5.17 CFM 1.20 CFM With House 1.78 CFM 2.17 CFM 0.60 CFM Wrap House Wrap Taped 1.22 CFM 0.85 CFM 0.18 CFM For more information call (800) 825-4434, ext. 8490 or visit us online at www.knaufinsulation.us

Knauf Insulation GmbH One Knauf Drive Shelbyville, IN 46176 Sales and Marketing 1-(800) 825-4434, ext. 8490 Technical Support 1-(800) 825-4434, ext. 8512 Fax 1-(317) 398-3675 Information info.us@knaufinsulation.com World Wide Web www.knaufinsulation.us 2012 Knauf Insulation GmbH. leed Eligible Product Use of this product may help building projects meet green building standards as set by the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. Credit 4.1-4.2 Recycled Content Credit 5.1-5.2 Regional Materials Knauf Insulation EcoSeal Sealant is certified for indoor air quality as a low emitting product by The GREENGUARD Environmental Institute to both the GREENGUARD Indoor Air Quality Certification Program SM and the more stringent GREENGUARD Children & Schools standard and is verified to be formaldehyde free. www.greenguard.org