PE/PH. Product Data Parking Pallet. longitudinally shifting. Parking Pallet PE/PH

Similar documents
Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Data Sheet Wöhr Combilift 552-2,0

Data Sheet Wöhr Combilift 552-2,6

Product Data TrendVario

QUADROPARKER SERIES QUADROPARKER N4904 THE IDEAL SOLUTION FOR THE EXTERIORS; ON 4 LEVELS CAR STACKERS

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Tender specification KLAUS Multiparking TrendVario 4300

PARKLINE SERIES UNIPARKER N5202 THE SEMI-AUTOMATIC PARKING SYSTEM WITH PIT AND WITHOUT COLUMNS AT THE ENTRY SEMI AUTOMATICS

Access Chambers Systems

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Section 1 OBC FADS /13 Access to Parking Areas

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S

We store: high. wide. deep. safe. Shelving racks. System C 50 single-tier multi-tier

CITY OF FORTUNA, CALIFORNIA

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

VPL-3200B Residential Vertical Platform Lift Technical Specifications

Cavity Design and U-Channel Relationship

ELVORON LU/LA ELEVATOR

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS

Conergy SolarFamulus II

Freight Elevator Series GFM-T

Introduction. Disclaimer. Table of contents

ASSEMBLY INSTRUCTIONS

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

A. Product Data shall be provided for each type of product indicated.

TECHNICAL SPECIFICATION

Series - 1

SECTION OUTLET, PULL, AND JUNCTION BOXES

Planning and installation instructions

REQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS

Trench Duct Class Catalog 5230CT9601R10/08

TI-LINE TILUX DURABASE. Borderless Shower Areas

Instructions for installation and use PFEIFER LSV Lifting Loop

Electrically operated, roof retractable basketball goals Information pack

Glass Reinforced Concrete DRAINAGE CHANNELS

Economical paving of 4.0-m to 12.0-m wide concrete slabs Slipform Paver SP 1200

DICTATOR Lift Shaft System

General Symbols, Ducts and Cables

h Installation Manual

PLYWOOD FLOATING FLOOR

ELEVATORS, LULAS AND PLATFORM LIFTS

Locrete Building System: the Technology Handbook

Protective Capony RTC-16

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

Z5043 MAX Horizontal bracket Mounting instructions

Pre-installation Manual CONCEPT 301 D/401 D/501 D

Product Application. Prestige Power Post in White Epoxy Coated Aluminium Finish

HORIZONTAL CONCRETE MIXING PLANTS. Horizontal Concrete Mixing Plants HN 1.5 HN 4.0 H 5 H 6

Die changing station, electrically driven Dies up to a weight of 200 kn

Modular Protection Systems

Rack Guard Safety. Industrial. InCord incord.com

ENGINEERING DESIGN & IMPROVEMENT STANDARDS

Fully Automated Storage. System

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Mobile Racking Systems Storage systems for more products on less surface area

HALFEN HLB LOOP BOX Z-HLB-M50 13-E CONCRETE

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

Thousands produced. GEBHARDT ConVer Goods Lifts modular and customised

2600SEG135 SAFETY STANDARD FOR INDUSTRIAL LADDERS AND STAIRCASES IN BUILDINGS

ProShell Support Profile for AS/RS and Transfer Cars. An Option for Conductix-Wampfler Conductor Rail Systems

Installation Guide. Floor heating. Vodoley CO

Non-rigit-PVC. Soft PVC strips

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

TYPICAL INSTALLATION INSTRUCTIONS

Solar Powered TS1000 Installation Pictures. (Trench and Fill Method) City of Vallejo, CA

ifix INSTALLATION MANUAL PV flat roof installation system Version

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

StormTech Construction Guide

SECTION NON-STRUCTURAL METAL FRAMING

CER.F.F. Test certification for a partition model MOBILE PARTIONING MOBILE WALLS. Technical specifications

MDS TL5 Minimum Deflection Systems

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

SpaVault TM Installation Guide for Bullfrog Spas (7-10 x 7-10 x 38 )

Electric Service Standards

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Design Standard Conduit for Electrical Systems

ELECTRO-FENCE. Fence Protection System. System Manual. EF_System_V1.1

DRIVE-IN PALLET RACKING

LUX ELEMENTS -TUB-BOL shower base elements

Natrona County Development Department 200 North Center Street, Room 205 Casper, WY Phone: Fax:

SPECIFICATIONS FOR THE CONSTRUCTION OF NEW PASSENGER EQUIPMENT CARS PREFACE

SMART FIXING SYSTEMS

Technical specification Slipform Paver SP 1600

Z5033 E3 Ball joint adapter Mounting instructions

Hollow Core Slabs Applications

Movibloc Mobile Shelving / Mobile Lockers

Ladders and scaffold systems

Table of Contents. Installation 2-10 Leveler legs... 2 Controller... 4 Dip-switch Configurations. 5 Wire Harness Installation.. 7

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers

Design strategies for the future

Product Manual Release 05/17

Reinforced concrete slot channel

MOBILE ROBOTS - A NEW GENERATION OF PRODUCTION TASKS FOR ROBOTS. Emil - Figge - Stral 3e 75 D-4600 Dortmund 50 West Germany ABSTRACT

Transcription:

of 5 Car Parking Pallet PE/PH Warning light or support Product Data Parking Pallet PE/PH longitudinally shifting CONFORMITY DH 9.5 B Direction of movement 32 : All space requirements are minimum finished dimensions. Tolerances for space +3 requirements 0. in cm. Top edge finished floor: Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 182, table 3, line 3! Type No. of vehicles DH PE 1 PH 2 acc. to local requirements acc. to local requirements Standard type Type W L Shift. length Wheel-location recess PE 215 500 470 PH 215 1000 970 Exclusive type axis Type W L Shift. length PE 245 530 500 Travel path 15 L PH 245 1060 1030 Suitable for: Standard passenger car and station wagon. Parking Pallet PE Building law requirements Parking Pallet PH According to the German Building Code parking spaces on longitudinally shifting parking pallets are only permitted if the following requirements are met: Next to the parking pallets a remaining driving lane width of 275 cm minimum must be maintained. Parking pallets must not be installed before power-driven parking systems. In case of two-way traffic in the driving lane no through traffic is permitted. The parking pallets must be traversable on all sides. Walkable areas must provide headroom of 0 cm. Make sure to observe the ventilation systems, bearers or other installations. The parking pallets have a height of 10 cm. Length Width Height Weight Wheel load Weight Wheel load Car dimensions max. 5.00 m max. 1.90 m 10cm less than DH Standard type max. 00 kg max. 500 kg Exclusive type max. 2300 kg max. 575 kg Standard passenger cars are vehicles without any sports design such as spoilers, low-profile tyres etc. Klaus Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Phone +-75 65-5 08-0 Fax +-75 65-5 08-88 E-Mail info@multiparking.com Internet www.multiparking.com Parking Pallet PE/PH Code number 584.16.990-001 Version 01.07

Parking Pallet PE/PH Code number 584.16.990-001 Version 01.07 of 5 Car : Longitudinal Pallets with Above-Floor ( S) 1 x PE 1 x PH 515 500 500 500 1015 1000 1000 1000 2 x PE 650* 650* ** ** acc. to local requirements 2 x PH 1015 1015 ** ** acc. to local requirements 650* 500 650* 1015 1000 1015 3 x PE 3 x PH 650* 500 500 650* 1015 1000 1000 1015 * = Recommendation Combination: At a length of 40 m up to 5 pallets can be arranged as group should their shifting path overlap. In this case the operating elements must be within a distance of 10 m of a possible point of contact between two pallets. Above-Floor ( S) or support Cover marked with yellow/black stripes Cable mounted to support 85 dowelled to floor Guide rail 33 If distance to support >, cable cover is required! 30 and Tolerances (Abstract from DIN 18 2, Table 3) The safety distance between the lower flange of the platforms and the garage ground must therefore not exceed 2 cm. To adhere to the safety regulations and VdTÜV/CEOC recommendations and to get the necessary even ground, the tolerances of evenness according to DIN 182, table 3, line 3, must not be exceeded. Therefore exact levelling of the ground client is essential. Column 1 2 3 4 5 6 Line 2 Reference Unfinished to surface of covers, subconcrete and subsoils for higher demands, e.g. as foundation for cast plaster floor, industrial soils, paving tiles and slabstone paving, compund floor paving. Finished surfaces for minor purposes, e.g. warehouses, cellar. Vertical measurement as limits in mm with measuring points distances in m to* 0,1 1 4 10 15 5 8 12 15 3 Finished grounds, e.g. floor pavement serving as foundation for coverings. 2 4 10 12 15 Coverings, tile coverings, PVC flooring and glued coverings. * = Intermediate values are to be taken out the diagram and must be rounded-off to mm Tolerances in mm 15 10 5 Line 2 Line 3 0 8 9 10 18 19 22 23 24 25 26 27 28 29 30 Distance between measuring points in m

Car Parking Pallet PE/PH Code number 584.16.990-001 Version 01.07 Longitudinal Pallets with Underfloor ( U) If the drive axis cannot be placed in front of a support the drive will be designed as underfloor drive. Precondition: axis located in parking space axis; recess in floor. For arrangement of longitudinal pallets, see example: 2 x PE Conduit EN 40 (M40) with taut wire to nearest support or to wall of 5 1015 1000 1015 Underfloor ( U) Box for drive 25 8 Conduit EN 40 (M40) Guide rail 37 75 50 Box cast in concrete after installation Rail System Prior to using poured asphalt it is essential to consult Klaus! PE und PH Prior to floor pavement 176 (6) Top edge finished floor Projection of the guide rail above top edge of finished floor is mandatory on both sides of the rail including the level for the drive! ca. 4 filled up with rails packed up max. 5 In recess (RR = running rail; GR = guide rail) RR GR ca. 4 250 (280) ( ) = in brackets for Exclusive type On finished floor 0,5 +0,5 The rails are dowelled directly onto the top edge of the finished floor. Drill hole depth: approx. 9 cm. Tolerances for the evenness must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 182, table 3, line 3! PE und PH in this area the same level is necessary 260 (290) max. 1 % max. 1 % ( ) = in brackets for Exclusive type

Parking Pallet PE/PH Code number 584.16.990-001 Version 01.07 of 5 Car ing Standard Parking Spaces (for example No. 6) ing the Pallet Parking Spaces If pallet is empty: passing of pallet possible Operating element for pallet 21 Operating element for pallet If pallet is occupied: press corresponding pushbutton for no. 21 on operating element. Pallets and 21 are moved together automatically, and parking spaces 6 (and 7) become free. Note: PE at End of Driving Lane To access parking space no. both pallet and 21 are moved in a way that the required driving lane is created. Direction of driving Exit to driving lane Solution: Dislocate support or drive Solution: Use of PH 515 500 500 750 500 500 515 500 500 Unfavourable!! Parking spaces 1, 2, 11, 12 can only be accessed unfavourably since both driving and turning range are strongly restricted. Driving and turning range for parking spaces 1, 2, 11, 12 are improved! Note: Dislocated Parking Spaces Makeshift: One-sided pallet extension Makeshift: Travelling drive (drive D) Not possible!! Parking space 12 cannot be accessed if parking space is occupied. Reason: Axes of opposite parking spaces are offset. Extension (max. 1 m) Travelling drive: D on the pallet allows longer travel path. Power supply via trailing cable. Special guide rail. Warning: Pallet not accessible within range of drive! al installation al supply/control system The must provide a supply of 5 x 2.5 mm 2 (3 PH+N+PE) to the electric cabinet (larger systems may require larger cross sections). Proposals for position of control box and operating element are specified in the floor plans provided by Klaus Multiparking. Operation Operation via operating element with automatic reset function (two pushbuttons for left/right movement). Range of application Generally, this parking system is not suited for short-time parkers (temporary parkers). Please do not hesitate to contact your local KLAUS agency for further assistance. Available documents maintenance offer/contract declaration of conformity Corrosion protection See separate sheet regarding corrosion protection. Noise emission Ball bearing of the rollers provide a low sound level. Environmental conditions Environmental conditions for the area of multiparking systems: Temperature range 10 to +40 C. Relative humidity 50 % at a maximum outside temperature of +40 C. On block opration Parking pallets must only be operated on block if the operator s stand is not more than 10 m from the platform edges that are to be operated on block, and if it is installed at least 1.60 m above garage floor.

Car Parking Pallet PE/PH Code number 584.16.990-001 Version 01.07 Numbering of parking spaces Consecutive numbering of pallet parking spaces Building services Lighting, ventilation, fire extinguishing and fire alarm systems. al supply to the control box al supply 5 x 2.5 mm 2 (3 PH+N+PE) with lockable main switch to control box. Main fuse: 3 x fuse 10 A (slow) or circuit breaker 3 x 10 A (trigger characteristic K, G or C). 5 or more pallets: 3 x fuse 16 A (slow) or circuit breaker 3 x 16 A (trigger characteristic K, G or C). al supply to the control box must be provided during installation. The functionality can be checked on site by our fitters together with the electrician. If this cannot be done during installation for some reason for which the is responsible, the must commission an electrician at his own expense and risk. Marking Any additional yellow-black markings on the platform edges according to ISO 3864. If the following are not included in the quotation, they will also have to be provided / paid for : Costs for final technical approval by an authorized body of 5 Main switch Lockable main switch per electric cabinet. The lockable main switch is to be mounted directly next to the control cabinet. Floor Flooring structure in accordance with our instructions, please see page 2 (recesses, tolerances for the evenness of the driving lane must adhere to DIN 182, sheet 3, line 3. Packing up of rail system (and box for drive U) with cement floo for the whole length. Conduit EN 40 (M40) with taut wire to underfloor drive. General description Multiparking system for parking 1 or 2 vehicles. are in accordance with the respective underlying height and width dimensions. Parking pallets, which can be moved lengthwise are installed in the driving lane of underground garages. These parking pallets make it possible to achieve additional parking spaces in the driving lane, which is generally only used for maneuvering vehicles. The parking pallets can be driven on if vacant, or moved if occupied by a car when accessing parking spaces located in the back. This operation uses dead man s control safety mechanism. Therefore, the operating elements are generally mounted to the opposite supports and the parking pallets and parking spaces arranged by the controller can be seen. Operating instructions are permanently mounted to each operating station in a clearly visible location. These parking pallets are available in the following designs: Type PE: 1 passenger car Type PH: 2 passenger cars in a row Parking pallet consisting of: Sloped steel frames with supported low-noise track and guide rollers Crossbeams Platform profiles (cover plate) Positioning aids Small parts, etc. Pallet height: approximately 10 cm above finished floor Floor-mounted drive: Base plate mounted to the ground with geared motor Limit switch and housing The housing also serves as safety mechanism. The load transmission is carried out via a high-tension chain located in a U-profile which is open facing outwards. This chain is looped around two chain wheels and driven motor. Below-floor drive: This drive unit is mounted in a floor recess which must be built. This drive consists of: 1 geared motor Chain wheels Limit switch Fully mounted in a stable below-floor housing with cover The load transmission is carried out identically to the "floor-mounted drive" Moving drive (special): unit mounted to the parking pallet Power is supplied via a drag-line cable (or via contact lines in exceptional cases) The load transmission is carried out using a chain, which is inlaid in a special rail (double rail) Rail system consisting of: Profiles mounted to the floor, which must be embedded in concrete based on our specifications The guide rails protrude mm above finished floor, thus ensuring safe guiding when shifting the pallets The rail system can be fastened to the finished floor in exceptional cases and in the event of adequate evenness of the driving lane in the movement area of the parking pallets (see Floor in the chapter ) al equipment consisting of: Operating device with 2 buttons (right/left) Emergency Stop Control box Blinking lights Various cables with accessories Control system: The parking pallets are operated using a push-button with corresponding direction definition in dead man s control Limit switches stop the parking pallets when the maximum movement distance has been reached Warning lights blink during movement The electrical wiring originates in the control box We reserve the right to change this specification without further notice The Klaus company reserves the right in the course of technical progress to use newer or other technologies, systems, processes, procedures or standards in the fulfillment of their obligations other than those originally offered provided the derives no disadvantage from their so doing.