Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

Similar documents
WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

Issue date: 1st May Key changes since original publication (July 2005):

June Residential Refurbishment Separating walls

Selecting partitions

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system

Loadbearing timber joist floors

Tiling Tiling Finishes C08

Staggered stud acoustic partition system

Tiling Tiling

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

CasoLine MF Concealed grid MF suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system

Staggered stud acoustic partition system

GypLyner (walls) Metal framed wall lining system. GypLyner.

The extra strong, extra durable, sound resistant system that you can direct fix to

C05. S03. P02 P08 FireWall

ShaftWall. Shaft and duct encasement system. ShaftWall.

Isover Installation Guide

Product Information Sheet

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

SOUND INSULATION TESTING IN DWELLINGS

Part E robustdetails. robustdetails. April 2017 Update Pack. Dear Colleague,

Quantity take-off details

Boards. Products - Boards.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

C06. S02. P02 P22 CasoLine mf

CI/SfB. November Design Guide Concrete block masonry

C05. S02. P02 P30 ShaftWall

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Part E robustdetails. robustdetails. September 2017 Update Pack. Dear Colleague,

URSA MINERAL WOOL URSA Acoustic Roll

June Non - Residential Refurbishment Internal lining walls

CO9. Sound absorbing solutions C09

The ecological choice. Besblock STAR PERFORMER. The multi-purpose energy saving block JULY 2014 UNIVERSAL, COST EFFECTIVE, DELIVERABLE

Multi-layer Insulation Blanket for Walls

December 2011 OFF-SITE. Off-site solutions

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

F L O O R S A N D C E I L I N G S

Acoustic Detailing For Steel Construction

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

PITCHED ROOF SOLUTIONS

Ceiling Attenuation Class Systems SYSTEMS 280

THE FRAME RESIDENTIAL DEVELOPMENT, SPORTCITY, MANCHESTER THE CONCRETE CENTRE LTD 1.0 INTRODUCTION...2

Metal Solutions.

URSA MINERAL WOOL URSA Cavity Batts

Multi-layer Insulation Blanket for Walls

June Residential New Build Render and cladding walls

Thermal Laminate Board.

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

BISON PRECAST FLOORING SPECIFICATION

Product Application Guide

Aircrete blocks product guide

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

CHAPTER 3: Modern Methods of Construction (MMC)

HP Partial Fill. Robust, long-lasting protection


SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.


RAINSCREEN DUO SLAB. Non-combustible thermal insulation

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

Multi-layer Insulation Blanket for Walls

Benefits.

appended hereto: E119-10b 252: 2008

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

Acoustic Cradle Levelling System

Knauf MF Suspended Ceilings

The Passive Fire Protection Handbook

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

ACOUSTIC SUPPLIES. For Acoustic Solutions you can SHOUT about

BUILDING INSULATION PRODUCT AND DELIVERY GUIDE

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

Multi-layer Insulation Blanket for use in Walls

Specialists in Acoustic Flooring and House to Flat Conversions

URSA 20 Plus and URSA 20

URSA MINERAL WOOL URSA HOMETEC Cladding Roll

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Plasterboard accessories - Products

September Saddle Flooring Systems

Building Design Data

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

AUGUST AUSTRALITE fire, acoustics & thermal technical manual

GIB Quiet Clip GIB CBI March Features and Benefits

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Insulation options. Calculating U-Values

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

3.1 Noise Overlay District

Transcription:

Separating walls Countryside Properties, ock 8, Stoke-on-Trent

Separating Masonry walls Walls Separating Masonry wallswalls Approved Document E 200 Clause E Approved Document 200 - Requirements Walls >> Separating Walls >> Separating Masonry Walls walls Separating wall constructions must be built to comply with Building Regulations Approved Document E clause E and are subject to Pre-Completion Testing unless a Robust Detail construction is used. Clause E of Approved Document E stipulates the following: Dwelling-houses, flats and rooms for residential purposes shall be designed and constructed in such a way that they provide reasonable resistance to sound from other parts of the same building and from adjoining buildings. Approved Document E 200 Performance standards The following table is adapted from Approved Document E and highlights the minimum performance standards required for separating walls. Please note that the requirement is for airborne sound insulation only. Contrary to previous assumptions, Approved Document will no longer treat separating cavity walls as a zero heat loss element, due to the thermal bypass effect The heat loss can be reduced by measures that restrict air movement through the cavity, either by means of fully-filling the cavity and/or by providing effective sealing around the perimeter. Table - U-values for party walls Party wall construction U-value (W/m 2 K) Solid 0.0 Unfilled cavity with no effective edge sealing 0.5 Unfilled cavity with effective edge sealing around all exposed edges and in line with insulation layers in abutting elements 0.2 A fully filled cavity with effective sealing at all exposed edges and in line with insulation layers in abutting elements 0.0 Walls >> Separating Masonry walls Walls Dwelling-houses and flats - performance standards for separating walls that have a separating function Airborne sound insulation D ntw + Ctr db Inpact sound insulation nt, w db New build separating walls 45 - Rooms for residential purposes - performance standards for separating walls that have a separating function Airborne sound insulation D ntw + Ctr db Inpact sound insulation nt, w db New build separating walls 4 - Roof oft Space oft Insulation Roof oft Space oft Insulation What is the thermal bypass effect? Where outside air is able to flow into the separating wall cavity a cold zone is created which results in heat flux through the wall sections on either side. The extent of air flow and heat flux will depend on external conditions such as wind and temperature and also on the setting up of a ventilation stack effect caused by warmed air rising in the cavity to be replaced by cooler air drawn in from outside. The air movements involved can be significant and, if no steps are taken to restrict flows, the resulting heat losses can be large. How to comply Robust Details - All Robust Details have been approved as capable of meeting or exceeding the E performance criteria, providing they are built correctly. Following these specifications means the construction can be exempt from undertaking Pre Completion Testing. The Robust Details scheme applies to new-build houses and apartments only. Plots must be registered with Robust Details imited prior to construction. NB It is important to check the compatibility of the Robust Detail separating walls with the Robust Detail separating floors. Please refer to www.robustdetails.com for more information. Manufacturers Proprietary Systems - These constructions are British Gypsum Approved Systems, which, provided they are built correctly, have the potential to achieve E performance criteria required for new-build houses and apartments separating floor constructions and new-build rooms for residential purposes. Pre-Completion Testing must be executed on a 0% sample (by type) to demonstrate compliance. st Floor Ground Floor st Floor Ground Floor Isover Party Wall Roll Isover Party Wall Roll is a full-fill glass mineral roll for use in 75mm, 00mm, 25mm and mm separating wall cavities. The product meets the full-fill requirement to deliver a zero U-value for separating party walls as defined in Building Regulations (Approved Document A, Table ). See page 56 for Separating Wall Solutions 29 and 0 and also page 97 for further product information The Within category 7 of the, Health and Wellbeing, section states that up to four credits are available for achieving higher standards of sound insulation than those given in Building Regulations Approved Document E and demonstrating it by using either Pre-Completion Testing or Robust Details. This stamp highlights construction details which have the potential to achieve the number of credits stated, provided they are built correctly. Section 5 - Scotland Section 5 (Scotland) stipulates a minimum airbourne sound performance for separating walls of 56 D ntw db. Please be aware that Scottish Regulations do not recognise a correction factor for low frequency sound. Airbourne sound insulation D ntw db Zero U-values Can be used as part of a solution to achieve Zero U-value solutions This stamp highlights construction details which have potential to achieve a zero U-value, provided they are built correctly. Scotland Scottish regulations also recognise that separating walls should no longer be treated as zero heat loss. Section 6 stipulates the following: To limit heat loss, a separating wall cavity should have effective perimeter sealing around all exposed edges and in line with insulation layers in abutting elements which separate the dwelling from another building or from an unheated space. Further reduction in heat loss can be achieved where the cavity separating wall is also fully filled with a material that limits air movement. Separating walls 56 48 www.isover.co.uk Isover Technical Advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 49

E-WM-24 E-WM-24 Separating walls Separating walls Walls >> Separating walls Separating wall solutions The separating wall solutions detailed in this section of the guide are Robust Detail or British Gypsum Approved Systems. These constructions have been tested and proved to meet or exceed the sound insulation values given in the table on page 49. Please note that for British Gypsum Approved Systems Pre-Completion Testing must take place to demonstrate compliance. Separating wall solutions (Robust Details) 2 24 25 26 27 28 29 0 E-WM-8: Masonry ightweight aggregate blockwork (5mm Isover 5 and Gyproc plasterboard) E-WM-4: Masonry ightweight aggregate blockwork with 00mm cavity (5mm Isover 5 and Gyproc plasterboard) E-WM-5: Masonry aircrete blockwork (5mm Isover 5 and Gyproc plasterboard) E-WM-7: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WM-20: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WM-24: Masonry Masonry aircrete aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) E-WT-: Twin Timber without sheathing board E-WT-2: Twin Timber with sheathing board Airborne sound db (D ntw + Ctr) - site test result 45 46 47 48 49 5 52 5 54 55 56 57 58 59 60 48 48 48 6 7 8 9 40 4 42 4 44 Separating wall solutions (British Gypsum Approved) GypWall classic With Gypframe 46 AS AcouStuds GypWall classic With Gypframe 46 AS AcouStuds GypWall quiet GypWall quiet with additional service zone created with Gypyner universal Airbourne sound transmission (R w + Ctr db) - lab test result 5 52 5 54 55 56 57 58 59 60 6 62 6 64 65 56 57 5 57 54 54 5 58 62 Walls >> Separating 2 E-WS-: Twin Steel E-WS-2: Steel (Non-loadbearing) 47 47 Isover Products Isover separating wall solutions incorporate the following Isover products Isover Party Wall Roll Isover 5 Isover Acoustic Partition Roll E-WS-: Twin Steel Modular build steel frame 4 E-WS-4: Twin Steel Isover Acoustic Slab Isover Timber Batt Isover Timber Party Wall Roll 5 Masonry Walls Gypyner universal lining 59 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 5

Separating Masonry masonry Walls walls Separating Masonry masonry Walls walls Walls Walls >> Separating >> Separating Masonry masonry Walls 2 E-WM-8: Masonry ightweight aggregate blockwork (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 20mm ightweight aggregate cavity block wall, minimum 00mm blocks (density - 600kg/m³) Minimum 75mm cavity between leaves Isover 5 in the cavity Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus C 25 E-WM-5: Masonry Aircrete blockwork (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 20mm Aircrete cavity block wall, minimum 00mm blocks (density 600 800kg/m³) Minimum 75mm cavity between leaves Isover 5 in the cavity Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) B Walls >> Separating Masonry masonry Walls Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) 24 E-WM-4: Masonry ightweight aggregate blockwork with 00mm cavity (5mm Isover 5 and Gyproc plasterboard) Overall construction nominal width 45mm ightweight aggregate cavity block wall, minimum 00mm blocks (density - 600kg/m³) Minimum 00mm cavity between leaves Isover 5 in the cavity Drylined with 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc dot and dabbed (Driyner basic system) C s 26 E-WM-7: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Overall construction nominal width 20mm ightweight aggregate cavity block wall, minimum 00mm blocks (density 600kg/m³) or Plasmor Aglite Ultima 0 kg/m cavity block wall Minimum 75mm cavity between leaves Minimum 75mm Isover Party Wall Roll in the cavity Drylined with dot and dabbed 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc B Zero U-values Can be used as part of a solution to achieve 52 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 5

E-WM-24 E-WM-24 Separating masonry walls Separating masonry walls Walls >> Separating masonry 27 E-WM-20: Masonry ightweight aggregate blockwork (Isover Party Wall Roll and Gyproc plasterboard) Overall construction nominal width 45mm ightweight aggregate cavity block wall, minimum 00mm blocks (density 600kg/m³) Minimum 00mm cavity between leaves Minimum 00mm Isover Party Wall Roll in the cavity Drylined with dot and dabbed 2.5mm Gyproc WallBoard ten, 5mm Gyproc WallBoard or 2.5mm Gyproc SoundBloc Zero U-values Can be used as part of a solution to achieve B 29 Masonry walls Gypyner universal lining Core masonry element mass per unit area minimum 200Kg/m², e.g. 00mm high density aggregate blocks Gypyner universal wall lining to one side of wall with minimum 85mm cavity (framing at 600mm centres) ined with double layer of 2.5mm Gyproc SoundBloc, mm Isover Acoustic Partition Roll (APR 200) in the cavity Other side lined with either 2.5mm Gyproc WallBoard on the Driyner basic system or mm Thistle plaster finish Nominal width 22mm (drylined) or 22mm (plastered) 59dB R w + Ctr PSR B226005 Rw 66dB Walls >> Separating masonry 28 E-WM-24: Masonry Masonry aircrete blockwork (Isover Party Wall Roll and Gyproc plasterboard) B 0 E-WT-: Timber frame Without sheathing board 60mins BS A+ Aircrete cavity block wall, minimum 00mm blocks (density 600 800kg/m ) Minimum 00mm cavity between leaves Minimum 00mm Isover Party Wall Roll in the cavity Overall construction nominal width 00mm Cavity width minimum 240mm, gap of minimum mm between frames 90mm Isover Timber Batt 40 positioned between the studs in each timber frame Drylined with 2.5mm Gyproc WallBoard dot and dabbed (Driyner basic system) - Inner ayer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side Double layer of 5mm Gyproc SoundBloc each side, Zero U-values Can be used as part of a solution to achieve Double layer of 5mm Gyproc Fireine each side, Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc Fireine each side 54 55 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk

Separating timber frame walls Separating steel frame walls Walls >> Separating timber frame E-WT-2: Timber frame With sheathing board Overall construction nominal width 00mm Cavity width minimum 240mm, gap of minimum mm between frames Minimum mm gap between sheathing panels 90mm Isover Batt 40 positioned between the studs in each timber frame 60mins BS A+ or A- E-WS-2: Steel frame (non-loadbearing) Overall construction nominal width 2mm Minimum cavity width 90mm Gypframe I Studs minimum 60mm depth (no bracing between leaves) 00mm Isover Acoustic Partition Roll (APR 200) positioned between the frames D - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side, - Double layer of 5mm Gyproc Fireine each side, - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc Fireine each side Depending on sheathing board specified. Please refer to www.thegreenguide.org.uk for further information - Double layer of 5mm Gyproc SoundBloc each side (for 90 minutes BS and EN ) - Double layer of 5mm Gyproc SoundBloc each side overboard with one layer of 2.5mm Gyproc Fireine each side (for 20 minutes BS and EN fire resistance) NB: Fully-fill cavity with Isover Timber Party Wall Roll to help achieve a zero U-value wall 2 E-WS-: Steel frame 60mins BS A+ 4 E-WS-: Steel frame Modular build steel frame 60mins BS B or C 2 For use in lightweight steel frame housing or flats / apartments Only for use in lightweight steel frame housing or flats / apartments Minimum cavity width 200mm Overall construction nominal width 264mm oadbearing studs Minimum 72mm or 00mm loadbearing studs Overall construction nominal width 26mm Minimum 40mm gap between sheathing panels mm Isover Batt 2 positioned between the frames 25mm Isover Acoustic Partition Roll (APR 200) between the studs in each frame - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side Subject to manufacturers substantiation based on their loadbearing stud Minimum 75mm minimal Isover TS48 Slab (45Kg/m³) positioned between the studs - 72mm studs - double layer of 5mm Rigidur h - 00mm studs - double layer of 2.5mm Rigidur h Depending on sheathing board specified. Please refer to www.thegreenguide.org.uk for further information 56 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 57

Separating steel frame walls Separating steel frame walls 5 E-WS-4: Steel frame Only for use in lightweight steel frame housing or flats / apartments Minimum cavity width 2mm Overall construction nominal width mm Minimum 75mm loadbearing C studs 60mins BS A s 7 GypWall classic With Gypframe 46 AS AcouStuds Pre-Completion Testing - British Gypsum Approved System Overall construction nominal width 208mm Gypframe 46 AS AcouStuds at 600mm centres mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side 57dB 90mm Isover Timber Batt 2 positioned between the frames - Inner layer of 9mm Gyproc Plank, outer layer of 2.5mm Gyproc WallBoard each side - Double layer of 5mm Gyproc SoundBloc each side Subject to manufacturers substantiation based on their loadbearing stud ined with a double l ayer of 5mm Gyproc Duraine for 20 minutes PSR A206A255 6 GypWall classic With Gypframe 46 AS AcouStuds 8 GypWall quiet 56dB 5dB Overall construction nominal width 208mm Overall construction nominal width 200mm Gypframe 46 AS AcouStud at 600mm centres mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side Two frames of 48mm Gypframe C Stud at 600mm centres, cross braced at 200mm centres Cavity width of 40mm mm Isover Acoustic Partition Roll (APR 200) positioned between the frames ined with a double layer of 5mm Gyproc Duraine for 20 minutes PSR A206A24 ined with a double layer of 5mm Gyproc SoundBloc each side ined with a double layer of 5mm Gyproc Fireine for 20 minutes PSR A26009/0 58 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 59

Separating steel frame walls Separating steel frame walls 9 GypWall quiet Pre-Completion Testing - British Gypsum Approved System Overall construction nominal width 2mm Two frames of 48mm Gypframe C Stud at 600mm centres, cross braced at 200mm centres Cavity width of 90mm 75mm Isover Acoustic Slab positioned between the frames ined with a double layer of 5mm Gyproc SoundBloc each side ined with a double layer of 5mm Gyproc Duraine for 20 minutes 57dB PSR A260 R w 6dB 4 With additional service zone created with Gypyner universal 54dB Base separating wall, A wall lining with: Minimum 70mm cavity Minimum mm Isover Acoustic Partition Roll (APR 200) in the cavity Single layer of 5mm Gyproc SoundBloc installed on one or both sides of the base construction (for base construction refer to ) This solution can be used without lowering the acoustic performance of 40 42 54dB 5dB 20mins BS Overall construction nominal width 48mm Overall construction nominal width 48mm 70mm Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres fixed to one side of the studs 70mm Gypframe C Studs at 600mm centres with Gypframe RB Resilient Bar at 600mm centres fixed to one side of the studs mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side ined with a inner layer of 5mm Gyproc Fireine and an outer layer of 5mm Gyproc Duraine ined with a double layer of 5mm Gyproc Duraine for 20 minutes PSR A6009 PSR Q606040 60 www.isover.co.uk Isover technical advice - Tel: 05 945 4 Isover technical advice: isover.enquiries@saint-gobain.com www.isover.co.uk 6

Separating steel frame walls 4 Pre-Completion Testing - British Gypsum Approved System ( 45 db D ntw + Ctr) Overall construction nominal width 200mm Two frames of Gypframe 48 I I Studs at 600mm centres Cavity width of 40mm wide mm Isover Acoustic Partition Roll (APR 200) positioned in the cavity 58dB R w 66dB ined with a double layer of 5mm Gyproc SoundBloc each side A26D4 44 Pre-Completion Testing - British Gypsum Approved System 62dB R w 70dB Overall construction nominal width 2mm Two frameworks of Gypframe 60 I I Stud Cavity width of 90mm wide 00mm Isover Acoustic Partition Roll (APR 200) in the cavity ined with a double layer of 5mm Gyproc SoundBloc each side A260 62 www.isover.co.uk Isover technical advice - Tel: 05 945 4