Pulaski County, Virginia

Similar documents
4 EXTREME FOUNDATION PANELS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

RETAINING WALL LEVEL BACKFILL

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

10 EXTREME BASEMENT PANELS

POST FRAME BUILDING STANDARDS

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

SECTION MASONRY ACCESSORIES

LANDSCAPE RETAINING WALLS

SPECIFICATION GUIDELINE

STAY-FORM TRANSFORMING MATERIALS. into products that make a better world

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATION GUIDELINE

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

BUILDING CODES Presented by CORUM ENGINEERING

DIVISION 03 CONCRETE SPECIFICATION : FORMS AND FORMWORK

DESIGN CONSIDERATIONS FOR NSWS NATURAL STONE RETAINING AND FREE-STANDING WALL SYSTEMS

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

1. Section , Concrete Reinforcement and Embedded Assemblies. B. ACI 530/ASCE 5 - Building Code Requirements for Masonry Structures

STRUCTURAL MASONRY SPECIAL INSPECTOR. Study Guide

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

SECTION UTILITY MANHOLES AND STRUCTURES

Proposed Modification to the Florida Building Code

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

Anchorplex retaining wall construction guide. Building. Anchorplex. Retaining Wall Systems

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

SECTION CAST-IN-PLACE CONCRETE

MANUFACTURER S SPECIFICATIONS Section LIME CONCRETE. A. This section describes the requirements for floors and slabs on grade.

4 EXTREME FOUNDATION PANELS

Appendix J: Storm Conveyance Design Parameters

GABIONS AND REVET MATTRESSES

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Lintel Tables Design Notes and Limitations

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

1. Cast-in-place concrete is specified in Section

Concrete Slab-on-Ground

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

SECTION BRICK MASONRY ASSEMBLIES

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

MADISON WATER UTILITY MADISON, WISCONSIN UNIT WELL 26 GENERATOR ADDITION AND MCC UPGRADES

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year.

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION REINFORCING STEEL

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

BULLETIN FROM THE FIRST COAST CHAPTER ICC~BOAF

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

PLATON FOUNDATION WRAP

CTP STITCH-TIE AGAIN! Quick and easy way to re-anchor existing veneers to back-up structures.

AUGUST 2017 HASTINGS. retaining walls installation guide

Table of Contents. Page Title

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

A Design Review of Waterproofing Codes

SECTION ROOF SPECIALTIES

Composite / Veneer Units. Precision...1. Split Face... 2

TYPE "A" CATCH BASIN

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

INSULATED CONCRETE MASONRY UNITS Section 04220

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08

SECTION PERMANENT FORMS Insulating Concrete Forms Rev

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Redi Rock Specification and Installation Manual

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

SECTION NON-STRUCTURAL METAL FRAMING

FOUNDATIONS CHAPTER 4

SECTION UNIT MASONRY SYSTEM

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

SOILS AND FOUNDATIONS

SECTION INTERLOCKING CONCRETE PAVERS

Inlets & Catch Basins

Tasman Retaining Wall System

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Introducing a complete line of Limestone Classics TM Building Veneers from Indiana Limestone Company. Genuine Indiana Limestone the natural and

Fabrication and Installation Table of Contents

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

CONSTRUCTION SUMMARY REPORT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

PREPRUFE SCS Blindside waterproofing system for shotcrete foundation walls

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

Aluminum Component Pipe Railings

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CAST-IN-PLACE CONCRETE

Transcription:

Pulaski County, Virginia Typical Retaining Wall Details Based on the 2009 International Residential Code CONTENTS Timber Retaining Wall... 2 General Requirements... 2 Wall Construction... 2 Deadmen... 3 Connections... 3 Masonry Retaining Wall... 4 General Requirements... 4 Wall Construction... 4 Bond Beam and Reinforcement Details... 4 Dowels and Keyway... 5 Vertical Joints... 7 Backfill and Drainage... 7 Concrete Retaining Wall... 7 General Requirements... 7 Wall Construction... 7 Dowels and Keyway... 9 Vertical Joints... 9 Backfill and Drainage... 9 This design document applies to residential non-tiered, non-stacked retaining walls with level backfill and no surcharge loading retaining no more than 4 feet of earth. Retaining walls must be constructed in conformance with the details contained herein. Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 1 of 9

min. 1 4'-0" maximum TIMBER RETAINING WALLS General Requirements 1. All lumber shall be 6x6, southern pine, grade #2 or better and pressure treated in accordance with American Wood-Preservers' Association standards for ground contact. 2. All spikes shall be 60d or equivalent, hot-dipped galvanized or stainless steel and driven into predrilled holes. Spikes shall be of sufficient length to penetrate the base member a minimum of 2 inches. 3. Member joints shall be staggered a minimum of 3.5 feet from the joints of the course above and below. Wall Construction The construction of a timber retaining wall shall conform to the requirements shown in FIGURE 1 through FIGURE 3. deadman tieback, typical stagger joints 3'-6" min. 8'-0" typical stagger deadmen between courses FIGURE 1: TYPICAL ELEVATION typical deadman gravel backfill to within 1'-0" of top of wall level backfill only 30" cross plate, typical place drain pipe on a minimum of 4" of gravel 6'-0" 24" 4" diameter rigid perforated drain pipe, full length; drain to daylight FIGURE 2: TYPICAL SECTION Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 2 of 9

Deadmen Deadmen shall be placed at 8 feet on center as shown in FIGURE 1. Deadmen and cross plates shall be constructed as shown in FIGURE 3. Deadmen are not required in the bottom course below grade. 60d spikes @ 24" o.c. staggered, each course 2-60d spikes each end 30" cross plate deadman drain pipe FIGURE 3: TYPICAL DEADMAN DETAIL Connections Each 6x6 member shall be secured at each end with 2-60d spikes driven vertically into the member below. The corners shall be secured with 2-60d spikes and driven horizontally as shown in FIGURE 4. 2-60d spikes at each end of timber, typical 2-60d spikes at corners, typical FIGURE 4: TYPICAL CORNER DETAIL Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 3 of 9

3" 1 24" min. H MASONRY RETAINING WALLS General Requirements 1. The minimum concrete compressive strength at 28 days shall be 3,500 PSI and shall comply with ACI 318. 2. Reinforcing steel shall comply with ASTM A615 and shall have a yield strength of 60,000 PSI. 3. Concrete masonry blocks shall comply with ASTM C90. 4. All joint reinforcement, ties and other accessories shall be resistant to corrosion. 5. All head and bed joints shall be 3 / 8 -inch thick. Bed joints of the starting course over the concrete foundation may be between 1 / 4 -inch and 3 / 4 -inch. Mortar shall conform to ASTM C270. Wall Construction The construction of a concrete masonry retaining wall shall conform to the dimensions and reinforcing steel requirements shown in FIGURE 5 and TABLE 1. O bars, or dowels, can be lapped above the footing in accordance with FIGURE 9. 8" cement mortar cap or other detail as desired level backfill only O bars top bond beam with 2 #4 bars intermediate bond beam every other course with 2 #4 bars, typical B 3" P bars 3" W #3 bars @ 1 o.c. FIGURE 5: TYPICAL MASONRY WALL SECTION TABLE 1: TYPICAL MASONRY WALL SPECIFICATIONS H B W O-bars (dowels) P-bars 24 12 39 #3@32 #3@27 36 12 39 #4@32 #3@27 48 12 63 #4@16 #4@30 Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 4 of 9

lap length Bond Beam And Reinforcement Details A bond beam shall be provided at the top course and at intermediate courses below as shown in FIGURE 5. Bond beams shall be constructed using the block types shown in FIGURE 6. Vertical and horizontal steel placement shall be per FIGURE 7 and FIGURE 8. During construction, install wire loop in bed joint; loosen wire before mortar sets. Using wire loop, position vertical reinf. prior to grouting core. unit with section removed slotted unit (slots may be cast into unit or cut with a masonry saw) FIGURE 6: BOND BEAM BLOCK TYPE wire loop FIGURE 7: VERTICAL REINFORCEMENT TIE HOLD DETAIL vertical steel in filled cores horizontal steel in filled bond beams metal lath or similar material may be placed over un-grouted cores to prevent cores from filling with grout FIGURE 8: TYPICAL WALL REINFORCEMENT DETAIL Dowels And Keyway O bars, or dowels, can be lapped as shown in FIGURE 9. The minimum lap length shall be 15 inches for a #3 bar, 20 inches for a #4 bar, 25 inches for a #5 bar and 30 inches for a #6 bar. A keyway or roughened concrete shall be placed on the footing surface below the block wall; see FIGURE 9. roughen top of footing under wall prior to placement of concrete OR provide 1" deep by 4" wide continuous keyway FIGURE 9: TYPICAL DOWEL AND KEYWAY DETAIL Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 5 of 9

Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 6 of 9

24" min. Vertical Joint Control joints, constructed per FIGURE 10, shall be placed no more than 20 feet on center. Expansion joints, constructed per FIGURE 11, shall be placed at every forth control joint. line one side of core with building paper prior to filling cores cover earth side of joint with a strip of membrane waterproofing to prevent seepage through joint grease portions of bars extending across joint to prevent movement caulking, each side alternate courses bond beam course caulking, each side compressible material FIGURE 10: CONTROL JOINT DETAIL standard course FIGURE 11: EXPANSION JOINT DETAIL Backfill And Drainage Backfilling against reinforced masonry retaining walls shall not be permitted until at least 7 days after placing concrete or grout in cores. Heavy equipment shall maintain a distance away from the wall equal to the wall's height. Care shall be taken to avoid exerting large impact forces on the wall. finished grade Denotes undistrubed natual soil Denotes backfill material Denotes crushed stone gravel backfill to within 1' from top of wall and a minimum of 4" below drain pipe filter fabric, wrapped around 1 of gravel finished grade 4" diameter min. rigid or flexible perforated drain pipe, full length of wall connected to outlets at each end or weep holes at 8' o.c. where soil under footing consists of soft clay, place 4" to 6" of crushed gravel FIGURE 12: TYPICAL BACKFILL AND DRAINAGE DETAIL Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 7 of 9

20" min. 3" 1 24" min. H CONCRETE RETAINING WALLS General Requirements 1. The minimum concrete compressive strength at 28 days shall be 3,500 PSI and shall comply with ACI 318. 2. Reinforcing steel shall comply with ASTM A615 and shall have a yield strength of 60,000 PSI. Wall Construction The construction of a concrete retaining wall shall conform to the dimensions and reinforcing steel requirements shown in FIGURE 13 and TABLE 2. Dowels, can be lapped above the footing in accordance with FIGURE 14. 8" level backfill only #4@18" o.c. #4@18" o.c. #4@1 o.c. #4@13" o.c. #4@13" o.c. C #5@13" o.c. TABLE 2:TYPICAL CONCRETE WALL DIMENSIONS 1 H C W 24 19 39 36 28 48 48 40 60 1 Reference: Concrete Reinforcing Steel Institute 3" 5#4 bars, locations as shown above W FIGURE 13: TYPICAL CONCRETE WALL SECTION Dowels And Keyway Dowels, #4@13" o.c., must be lapped a minimum of 20 inches. A keyway or roughened concrete shall be placed on the footing surface below the block wall. See FIGURE 14. roughen top of footing under wall prior to placement of concrete OR provide 1" deep by 4" wide continuous keyway FIGURE 14: TYPICAL DOWEL AND KEYWAY DETAIL Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 8 of 9

24" min. Vertical Joint Control joints, constructed per FIGURE 15, shall be placed no more than 20 feet on center. Expansion joints, constructed per FIGURE 16, shall be placed at every forth control joint. 1/ x 1/ wood strip to be removed with formwork; fill void with mastic caulking or 1/ rubber strip, full height 1/3 1/3 1/3 FIGURE 15: TYPICAL CONTROL JOINT 1/ filler material FIGURE 16: TYPICAL EXPANSION JOINT Backfill And Drainage Backfilling against reinforced concrete retaining walls shall not be permitted until the concrete has reached its 28-day strength. Heavy equipment shall maintain a distance away from the wall equal to the wall's height. Care shall be taken to avoid exerting large impact forces on the wall. finished grade Denotes undistrubed natual soil Denotes backfill material Denotes crushed stone gravel backfill to within 1' from top of wall and a minimum of 4" below drain pipe filter fabric, wrapped around 1 of gravel finished grade 4" diameter min. rigid or flexible perforated drain pipe, full length of wall connected to outlets at each end or weep holes at 8' o.c. where soil under footing consists of soft clay, place 4" to 6" of crushed gravel FIGURE 17: TYPICAL BACKFILL AND DRAINAGE DETAIL Revised: 03/05/2012 Pulaski County, Virginia - Typical Retaining Wall Details Sheet 9 of 9