Collection of Samples for Analysis of Volatile Organic Compounds (VOCs) in Indoor Air Using Sorbent Tubes. BAA Guide October 1, 2007

Similar documents
C146-E096 TD-20. Shimadzu Thermal Desorption System

Using the PPM2 Portable Trace Moisture Transmitter

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

Guidelines for QualiTru Line Sampling

VOC-TD Application Manual

EMSL Cryptosporidium and Giardia (EPA 1623/1623.1) Sampling and Shipping Instructions. Instructions for Field Filtered Samples (10 or 50 Liters)

Method Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. EPA/600/R-10/181 December 2010

W ater T alk. Field Corrosion Testing using Coupons

MATERIALS OF CONSTRUCTION

STANDARD OPERATING PROCEDURES

ASI MODEL DM 100 SERIES DILUTING MODULES

STANDARD OPERATING PROCEDURES SOP: 2040 PAGE: 1 of 10 REV: 0.0 DATE: 05/17/02

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

Product data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN

Field Tests of Chloroform Collection/Analysis Methods

Extreme Sealing Tape

WBEA Standard Operating Procedure

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Steps in Conducting Structural Vapor Intrusion Potential Evaluations Under the Inactive Hazardous Sites Branch 13 February 2017

Protein-Pak Hi Res HIC Column and HIC Protein Standard

VELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d

VOC TEST REPORT French VOC Regulation

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

Clean coating of lithium with parylene-n. Abstract

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes

Sampling guide for determination of dissolved organic carbon and total dissolved nitrogen in seawater

These conditions must be maintained during transport to the laboratory.

Electron Microscopy Sciences

STANDARD OPERATING PROCEDURES

Capillary GC Troubleshooting: a Practical Approach

ANSI/AWS D R An American National Standard. Recommended Practices for Root Pass Welding of Pipe Without Backing

Performance and Application of an Inexpensive Method for Measurement of Nitrogen Dioxide

TECHNICAL DATA. ThreeBond Cyanoacrylate Adhesive. Features. Applications. Directions for Use

Super Clean Gas Filters Simply the best

Fire & Smoke VOCs Sampling Plan & Collection

Military Specifications

BromMax 7.1 CONCENTRATED LIQUID BROMINE BIOCIDE

Industrial flue gas probes. Instruction manual

PS-101 Preparing for Your Success

3M Plastic Bonding Adhesive 2665B, Black

Effect of the Relative Humidity on Formaldehyde Emission from Tackifier- Coated HVAC Filters

3SP_CO_1000 Package

Bonding to different materials possible (multi-purpose). Sealing, molding and potting purpose. Items Units Results Testing Method Remarks

ATT-42/95 SAMPLING, Asphalt

High Temperature Vacuum Tube Furnace GSL Operational Manual

SPECIFICATION Insulated Steam Injection Tubing Revision 6, dated 24 July 2011

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Topview 5630 Red SMD LED

Runoff Sampler Construction, Field Date:1l Sample Collection, and Handling of Surface Page: I of 16 Runoff Water Samples

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Lab 6 Measurement of Ozone

Part Numbers. Kinetico Drinking Water Systems. Revised: 07/2016 Drinking Water Systems Parts Pages Section 7 Page 1

On-Line Gas Analysis In Air Separation Plants

ANALYSIS OF INDOOR AIR QUALITY IN HIGH-SPEED TRAIN PASSENGER CABIN IN KOREA

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Copyright 2017 Aegis Sciences Corporation All Rights Reserved

Construction Indoor Air Quality (IAQ) Management Plan

SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

BOXCAR PRESS PHOTOPOLYMER PLATES DATA SHEET: KM73

3M Fast Tack Water Based Adhesive 1000NF

Pioneering ALD experience since The ALD Powerhouse PRODUCT CATALOGUE FOR SUNALE P-SERIES ALD SYSTEMS

onlinecomponents.com Prototyping : The Process

Dynatex Anti-Seize & Lubricating Compound. Phone Emergency Phone Fax (270) (800) (270) CHEMTREC

R442A (RS-50) Features and uses of the R442A (RS-50) Lubricants TECHNICAL DATA SHEET. Barcelona Girona Madrid Zaragoza

MARMOCRYL SILICONE Fine

AC : MICROWAVE PLASMA CLEANER DESIGN FOR SEMI- CONDUCTOR FABRICATION AND MATERIALS PROCESSING LABO- RATORY USE

SAFETY DATA SHEET Product #: See Section 1

SURFACE WATER SAMPLING

Group Stormwater Compliance Program Sampling Instructions

Safety Data Sheet HEATSINK COMPOUND NS-PCTC8 1 PRODUCT IDENTIFICATION 9 PHYSICAL & CHEMICAL PROPERTIES 2 COMPOSITION/INFORMATION ON INGREDIENTS

Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

Adhesive Transfer Tapes with

B. Protection of concrete mosaic, metals, stone, and other adjacent materials during all other work activities in related sections, below.

Kingspan Day-Lite Klick

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Military Specifications

myo-inositol Section 1 - Chemical Product and Company Identification

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

Oxygen Sensor Probes. Options for a Wide Range of Sensing Environments. Sensors

Kerotest/Marsh Needle Valves Series N

Compressed Air Filters Sample Filters

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT COMPLIANCE DEPARTMENT COM 1180

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

Pipe Protection Tape System

NDIA 6TH ANNUAL DISRUPTIVE TECHNOLOGIES CONFERENCE Washington DC October 14 15, 2009

Leak Detectors, Lubricants, and Sealants

SECTION HVAC INSULATION

STANDARD OPERATING PROCEDURES

DOWTHERM and SYLTHERM Heat Transfer Fluids in Sub-Zero Systems

Extreme Sealing Tape 4412N

Best/Worst Practices for Soil VOC Sampling Webinar VOLATILE ORGANIC COMPOUND ANALYSIS

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

DOW CORNING CORPORATION Material Safety Data Sheet

Parylene: what is it?

Transcription:

BERKELEY ANALYTICAL ASSOCIATES 815 Harbour Way South, Unit 6 Richmond, CA 94804-3612 Tel: 510-236-2325 Fax: 510-236-2335 Email: baalab@berkeleyanalytical.com www.berkeleyanalytical.com Collection of Samples for Analysis of Volatile Organic Compounds (VOCs) in Indoor Air Using Sorbent Tubes BAA Guide 07-01 October 1, 2007 Introduction This guide is intended for indoor air quality (IAQ) investigations involving the sampling of volatile organic compounds (VOCs) onto sorbent tubes for subsequent laboratory analysis of individual and total VOCs (TVOC) by thermal desorption GC/MS. Determining the appropriate sampling strategy is a critical first step to achieving the study s objectives. Additionally, field air samples must be collected properly to obtain meaningful results. Specific procedures covered in this guide include selection of sample volumes, control and monitoring of the sampling process, reducing sources of VOC contamination, and sampler storage and transport. Multisorbent samplers containing Tenax TA backed up by a carbon molecular sieve are recommended for most IAQ projects. The use of multisorbent samplers for air sampling of VOCs is covered in U.S. EPA Method TO-17 (see BAA website for a link to this method). Sampling Strategy 1. For many typical building investigations, it is recommended that samples be collected from several indoor locations and one outdoor location. As an example, if you are investigating a complaint building, you may consider collecting samples from the areas in the building with the highest complaint levels and at least one sample from an area in the building with a low complaint level to serve as a control. An outdoor sample may be collected to serve as a background reference. The outdoor location should be carefully selected to be representative of the ventilation air entering the building. For example, avoid hanging samplers immediately outside of open windows since air may be flowing out of the building at the windows. 2. It is recommended that two samples be collected at each location. These duplicate samples ideally should be co-located and collected simultaneously. This strategy provides backup samples in case there is a problem during analysis; and if both samples from a location are analyzed, a measure of sampling and analysis precision is obtained. 1

3. It may desirable to have a field blank in addition to an outdoor reference sample. Often only one blank sample is needed per building. The blank sampler should be handled, transported and stored identically to the other samplers. Description of the Sampler 1. The multisorbent sampler (Custom order, Supelco) for VOCs consists of a 3.5-in (90-mm) long by ¼-in (6.4-mm) passivated stainless steel tube packed with two sorbent materials (Figure 1). At the inlet, there is a section of Tenax TA (60/80 mesh), ~125 mg; this is backed up with a section of Carbosieve S-III (60/80 mesh), ~100 mg. There are two engraved rings at the inlet end. The sampler is installed so that the air being sampled enters the end of the tube closest to these rings. Each sampler has a unique identification number (alpha-numeric) engraved on the body of the sampler. This number should be used to identify the sampler in logs and on the chain-of-custody (COC) form. 2. The sampler is contained in a transparent acrylic tube with white plastic end caps fitted with Teflon-lined septa (Figure 1). The tube is slightly shorter than the length of the sorbent tube so the caps form positive seals at the inlet and outlet of the sampler. The caps should be hand tightened so the caps make firm seals but not over tightened to the point of damaging the septa. Do not use a wrench to tighten the caps. Handling, Storage and Transport 1. Samplers typically can be handled with ungloved hands. However, care must be taken to avoid contamination. For example, if your hands are dirty, oily or treated with hand lotion, wash them and/or use gloves. Clean white cotton or nylon gloves are recommended. Hold the samplers by the middle and try to minimize touching the ends near the openings. 2. Do not attach labels directly to the samplers as these labels are a source of contamination. Also, do not write on the acrylic tubes with marking pens as these tubes are reused. If it is necessary to put labels on the outside of the acrylic tubes, please be sure these are easy to remove and do not leave an adhesive residue. 3. Store, transport and ship samplers tightly enclosed in their storage containers. Avoid subjecting the samplers to elevated temperatures such as might occur in closed vehicles parked in the sun. It is recommended that samplers be transported and shipped in an ice chest using ice packs to keep the samplers cool. Prior to use of the samplers in the field, store them in a freezer or a refrigerator that is not used for the storage of chemicals. Under these conditions, the maximum recommended storage time for unused samplers is approximately three weeks. Return the samplers to BAA for analysis as soon as possible after the collection of samples. If used samplers must be stored prior to shipment to BAA, keep them in a clean refrigerator or freezer. 4. When storing, transporting and shipping multisorbent samplers, make sure that they are well isolated from any DNPH samplers that have been used for the collection of formaldehyde and other carbonyl compounds. These DNPH samplers can be a source of acetonitrile contamination. At a minimum, it is recommended that capped and enclosed multisorbent samplers and used DNPH samplers be contained in separate, sealed polyethylene bags. 2

5. When submitting samplers to BAA for analysis, be sure to clearly indicate what services are desired. An IAQ services COC form is available for download on the BAA website if you do not already have an appropriate form. Sampling Apparatus 1. If possible, draw air directly into a sampler so as to avoid connecting tubing to the inlet of the sampler. The only types of tubing that are acceptable for use upstream of the sampler are Teflon and stainless steel. Prior to use, any inlet tubing should be cleaned by flushing it with methanol and then thoroughly dried. Use a clean Swagelok ¼-in stainless-steel or Teflon union with ¼-in Teflon ferrules to join the inlet tubing to the sampler. Please do not use metal ferrules. 2. The sampling pump must be an oil-less type. There are a variety of AC or DC voltage diaphragm and peristaltic pumps that are suitable. It is advisable to check the compatibility of your pump using a spare sampler(s) prior to the collection of field samples. Fixed-speed peristaltic pumps are available on a rental basis from BAA. 3. The sampler must always be connected upstream of the sample pump. In some cases, the sampler can be connected directly to the inlet of the pump. Often it is desirable to locate the sampler away from the pump and connect the sampler to the pump with tubing. Inexpensive and easy-to-handle sample tubing is 1/4" O.D. polyethylene tubing. Other acceptable types of tubing are Teflon, Viton, silicon rubber, food-grade rubber, stainless steel and copper. Tubing composed of soft polymeric materials, such as Tygon, should be avoided. Use a clean Swagelok ¼-in union fitted with ¼-in Teflon ferrules to join the tubing to the outlet of the sampler. Please do not use metal ferrules. Alternately, flexible tubing (e.g., Viton and silicon rubber) sized appropriately to create a good seal can be slipped over the outlet of the sampler. 4. Aluminum, U-shaped brackets for mounting samplers may be available from BAA or can be easily fabricated. In office buildings, these brackets can be mounted to metal surfaces such as the tops or sides of filing cabinets and bookshelves with blue masking tape (avoid using tape on easily damaged surfaces). Sample Volume and Flow Rate 1. It is imperative to know the flow rate of air through the sampler and the sampling interval elapsed time in order to calculate the sample volume. For highest precision, the flow rate through the sampler should be maintained at a constant rate and monitored continuously, or at least frequently, during sampling. These objectives are best accomplished using electronic mass flow controllers in combination with a vacuum pump. Alternately, a pump with integrated flow control or a separate needle valve may be used to maintain constant flow rate. Electronic flow sensors, positive displacement flow sensors, bubble flow meters, or a rotameter may be used to monitor the flow rate. 2. The correct sample volume depends upon the concentrations of VOCs in the space being sampled. The analytical system has exceptional sensitivity, but limited range. Therefore, it is important to avoid collecting a sample volume that is too large and that may result in 3

overloading of the GC/MS system and in the loss of data for the sample. For most investigations conducted in office buildings or homes, the optimal sample volume is 5-6 L, or less. The same volume can be used for outdoor samples. This volume produces limits of detection for many individual VOCs that are typically about 1 µg m -3, or <0.5 ppb. If there is reason to suspect that the concentration exceeds several mg m -3 as TVOC, then a correspondingly smaller sample volume should be used. Examples are sampling locations with recent use of solvent-containing products or with strong odors. In situations in which there is uncertainty about the concentration, at least two samples of different volumes should be collected. For example, volumes of 1 and 5 L typically would cover the situation in which the concentration of TVOC could range up to about 10 mg m -3. In specialized cases, a much lower volume may be most appropriate. Please consult with BAA if you have any questions regarding the selection of a sample volume. 3. Every effort should be made to select the correct sample volume. However, an advantage of collecting duplicate samples is that the analytical split ratio can be changed if the analysis of the first sample overloads the GC/MS system. The standard split ratio used for analysis is 2:1. This ratio can be changed to 5:1, or higher if needed; but, large split ratios may introduce more uncertainty into the quantitative results for the sample. 4. The sample flow rate can range from a low of about 10 cm 3 min-1 up to about 200 cm 3 min-1. If it is desired to measure the integrated concentration of VOCs over an eight-hour work day, a sample flow rate of 10 cm3 min-1 results in a 4.8-L sample volume. A sample collected at 100 cm3 min-1 for 60 min results in 6-L sample volume, also in the acceptable range for typical building investigations. The maximum flow rate is limited by the pressure drop across the sampler and the capacity of the sampling pump. 5. The sampling system should be leak checked prior to use, preferably with the sampler in place. With some types of pumps, this can be accomplished by capping the inlet of the sampler and checking that the flow rate at the outlet of the pump drops to zero. 6. The air flow rate through the sampler must be determined. For flow regulation schemes other than those using electronic mass-flow controllers, it is necessary to directly measure the flow rate. At a minimum, this measurement should be made both near the beginning and end of the sampling interval. If possible, the measurement should be made downstream of the sampler, preferably at the outlet of the pump. A bubble flow meter, calibrated rotameter or other flow measurement device may be used. Record the measurement data including the air temperature and the atmospheric pressure so that the flow rate can be converted to standard indoor conditions (i.e., 25 C, 1 atm). If the measurement must be made upstream of the sampler, briefly use a calibrated rotameter following the precautions described above. Do not, under any circumstance, attach a bubble flow meter upstream of the sampler. This will contaminate the sampler. Also note that BIOS International DryCal Flow Calibrator systems are a potential source of methyl methacrylate contamination when used upstream of a sampler. 4

Other Sampling Precautions 1. Do not expose samplers used outdoors to direct sunlight. Aluminum foil can be used to make a simple sun shield. 2. If possible, avoid collecting samples in the rain or in very high humidity situations. The sampler will collect excess water vapor, which may result in the loss of the sample during GC/MS analysis. If such a sampling situation is unavoidable, be sure to indicate the humidity conditions on the sample COC form as excess humidity can be removed in the laboratory by purging with dry helium prior to an analysis. 3. If possible, avoid collecting samples at locations with high ozone concentrations as ozone may oxidize some sample components and can degrade the Tenax sorbent material resulting in the production of artifacts. The use of an ozone scrubber generally is not recommended as sample components can be lost by sorption to the scrubber. Figure 1. Multisorbent Sampler for VOCs 5