Sampling Instructions for Active Sampling

Similar documents
INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

Guidelines for QualiTru Line Sampling

Industrial flue gas probes. Instruction manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

WBEA Standard Operating Procedure

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

Electron Microscopy Sciences

ZS880 Linear Shower Drain Installation Instructions

RUST TRAP TECHNICAL DATA SHEET

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

CROMAX PRO WB9908 SUPER JET BLACK BASECOAT

STANDARD OPERATING PROCEDURES

UHV Cleanliness Requirements: Cleaning/Baking and Contamination Control

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

SECTION RESILIENT SHEET FLOORING

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Closed Dispense Systems

MAINTENANCE MECHANIC TRAINING TRAINER S GUIDE

Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles

RUST TRAP TM TECHNICAL DATA SHEET

Agilent InfinityLab Preparative Flow Cells for MWD & DAD

SECTION HVAC INSULATION

ASI MODEL DM 100 SERIES DILUTING MODULES

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

Absolutely. Positively. Precise.

Liner Replacement Instructions:

Performance, Beauty & Long Life STAINLESS STEEL CARE & MAINTENANCE. Stainless Steel Performance. Stain less Steel

USER S MANUAL. Whole-House Hydro Z Energiser. Natural Water Filtration, Purification and Energisation

PUF (PolyUrethane Foam) Sampler. GPS-1 Volumetric Flow Controlled Part Number Jul2008

VOC-TD Application Manual

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Rev. 07 8/15 Please Read Disclaimers:

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

G Sep Size Exclusion Columns

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Wood Floor Bonding Systems

SpeedExtractor E-916 / E-914 Technical data sheet

2000 User/ Installer Guide

SX-FOSC-D-96 Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

2. Crystallization. A. Background

Field Tests of Chloroform Collection/Analysis Methods

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

TA Instruments Packing the DHR Instrument

Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC) B1-OPSP12D Installation Manual

Offering the best price-performance in the industry. 1 (800) Presto Tape is a proud USA Manufacturer.

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional)

Technical Bulletin No. MK3176. PREPARED: July, 2010

Q. sample preparation for FTIR & How to sample introduce in the system?

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

Section [ ] Storm Water Treatment Device

Semi-volatile Organic Compounds; Indoor Air; Dust; GC-MS; DEHP

IN-TANK TECHNOLOGY INSTRUCTIONS FOR USING FLO KING IN-TANK CARBON BAG

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

Fire & Smoke VOCs Sampling Plan & Collection

2000-SG STAINLESS STEEL SLIDE GATES

SEB Autoclave Training

ANSI/AWS D R An American National Standard. Recommended Practices for Root Pass Welding of Pipe Without Backing

CLASS I AND II ABATEMENT PROJECT SUBMITTALS

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Simplexa Spectral Calibration Panel

Table of Contents. C. Recommended Remediation Firms: upon request

The PCI K-Floor meets all the needs of modern filtration practice in a single design.

Series 3000 Pocket Doors

A-Series Aluminum Gantry Crane

C146-E096 TD-20. Shimadzu Thermal Desorption System

RailRider Pro. September Education and Training Center RailRider Date 9/15/2015. Page 1

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Recommendations for Physical Space for Decontamination Areas

Product Application Guidelines. Platform Scales

OPERATIONAL MEMO GEN-14 Revision 3. November, Volatile Organic Compound (VOC) Sediment Sampling Method 5035 Field Sampling Procedure

STAINLESS STEEL STORAGE SOLUTIONS

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Copyright 2017 Aegis Sciences Corporation All Rights Reserved

Aqua Swing Tub Door & EX/RT Panel

W ater T alk. Field Corrosion Testing using Coupons

Water Level Meter User Manual

FILTRATION & UV SYSTEM

VE Technology Sampling System for the (Manual) Measurement of Trace levels of Mercury in Natural Gas. The Background

USER S MANUAL 400W and 600W

BESTMOVE STANDING TRANSFER AID

DWARF 100x9 ON THE ROAD WITH NEW SENYA EQUIPMENT

Soil Volume Change Meter (PVC)

BINAR Quick-Lift System

International Platinum Group Metal Association (IPA) Harmonised Methodology for the Sampling of Platinum in Workplace Atmospheres

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

INDUSTRIAL THERMOMETERS

Calibration Factors And Time-and-Distance Guidelines For Use of Theatrical Haze Equipment

ADA APPROVED SURFACE APPLIED DETECTABLE WARNING SYSTEM

T-Series Gantry Crane

Guidance on a semi-field test method for materials that are treated with biocides

BR 252 Water Based Bonding Primer

Transcription:

Sampling Instructions for Active Sampling Please read carefully before sampling CASSEN CASSEN Testing Laboratories Telephone: 416 679 9663 Toll Free: 1 866 423 3001 www.cassen.ca CASSEN Testing Laboratories 1

Sampling Instructions 1) Immediately Before Sampling Prior to handling the sorbent tubes, wash hands thoroughly without fragrant soap or hand cream to ensure no fragrant personal products are used. (These sorbent tubes are extremely effective in picking up trace levels of airborne organics; please make every effort to minimize any contamination, i.e. use cotton gloves to handle the tubes if possible) 2) Sorbent Tube Identification All sorbent tubes have unique identification numbers (etched on the side of the stainless steel tube). Compare and match this tube number to the number labelled on the canister. Write down this number on the Air Sampling Data Sheet for the location being sampled. 3) Direction of Air Flow Look for the tube end that possesses one or two grooves that are indented in the tube (dependant on the manufacturer) - this is the sampling end that provides air entrance. A typical sampling configuration is shown below: Be careful not to mistaken the etch marks as the grooves. CASSEN Testing Laboratories 2

4) Recommended Sampling Volume A. Open Characterization Analysis (Semi-Quantitative Only) In general, collect 5-12 L of air at a flow rate of up to 50 ml/min. If a limited time is allotted for sampling, use a flow rate of up to 100 ml/min. Total air volumes relating to specific conditions are presented below: Non-Industrial Indoor Air Quality Evaluation and Odour Complaints: Industrial Environments Strong chemical odour (i.e. solvents, oil): Moderate Odour: No Odour: 10-12 L 1-2 L 4 L 8 L B. Target Compounds Analysis Non-Industrial Indoor Environments (i.e. offices, schools, hospitals) and Outdoor Air For Quantitative analysis of target analytes Collect 5 L of air at a flow rate of up to 50 ml/min. C. Target Compounds Analysis Industrial Environments (i.e. processes involving chemicals) Industrial process sampling Collect 1-5 L of air at a flow rate of 20-50 ml/min. Some suggested sampling volumes are: Strong Odour: Moderate Odour: No Odour: 1 L 2-3 L 5 L CASSEN Testing Laboratories 3

5) Humidity Record the relative humidity during sampling, if inaccessible record the conditions (i.e. dry, raining, indoor/outdoor, etc.) on the Air Sampling Data sheet provided. Do not expose the sampling tube to rain or snow. 6) Pump Calibration a) Use the tube labelled For Calibration Only for initial pump calibration; do not use this tube as a field blank or for sample collection. Using this calibration tube, adjust the pump to the desired flow rate. Record this flow rate on the Air Sampling Data Sheet prior to sampling. b) For quantitative analysis, use a calibrator (i.e. DryCal DC-Lite) between the pump and the tube to check the actual sampling rate. Important: Never place the calibrator in front of the sorbent tube Note: Multi-bed sorbent tubes must be oriented so that the air sample passes through the series of sorbents in order of increasing sorbent strength (i.e. weaker sorbent is first). Sampling end can easily be identified by the grooves (1 or 2) at one end of the tube. The grooves indicate the weaker sorbent bed thus the pump must be connected to the end opposite the grooves. Air flowing in through this end allows the less volatile compounds to be adsorbed on weaker adsorbents first and hence enable better desorption, whereas the more volatile components will be trapped by the stronger adsorbent. Reversing this sequence will result in incomplete desorption. CASSEN Testing Laboratories 4

7) Tube Deployment a) Remove a tube from its canister; identify the two ends of the tube as previously mentioned. Keep the caps on until ready to begin sampling. b) Using the CapLok tool (see Appendix A) or wrenches, remove the hexagonal caps from the tube and promptly connect the appropriate end of the tube to the sampling pump using a clean, non-outgassing, flexible tubing. c) Keep the caps in the canister to prevent contamination. d) Position the pump on top of a tripod about 4-5 ft above the floor at a suitable location. Do not position the pump against a painted wall or partition in order to prevent any bias in measured concentration (paint chemicals may have higher concentrations). e) Orient the tube as required ensuring that the air is passing through the end with the groove(s). f) While sampling, the sampling tubes must be protected from extreme weather conditions and must not be allowed to come in contact with aerosol or particulate material without appropriate filters. Sampling outside during rainy or snowy conditions is not recommended unless measures are taken to completely protect the tubes. g) For accurate quantitative analysis, the exact flow rate of each tube must be checked with a calibrator in sequence in the field (see note on Pump Calibration). h) Record start time, pump flow rate, and other data on the Air Sampling Data Sheet. Flow rate must be verified after each sampling period. If there is a difference of 5% or less, the averaged value can be used. CASSEN Testing Laboratories 5

8) Field Blank At the sampling site, uncap the tube designated as the field blank and immediately reseal it. The field blank should be transported to and from the monitoring site in a similar manner to that of the sampling tubes. 9) After Sampling a) Record the Sampling Time b) Disconnect the tube from the pumps c) Recap the tube with the original hexagonal caps and tighten them using the CapLok tool or wrench. Do not overtighten. d) Wrap the tube with the provided aluminum foil and immediately place it into the original storage container, ensure the number on the tube matches with the number on the canister. The lab will record the canister number as the sample number if they do not match. e) Fill in the Chain-of-Custody form provided with the samples. Use the comment field to record any additional important information about the samples. Include an additional comment sheet if necessary so as to detail problems or deviations from the sampling plan. 10) Sample Storage Once sealed with the hexagonal caps, store the tubes at a 4 C temperature. The tubes should not be removed from the canister until they are in the laboratory and ready for analysis. Please return the Calibration Tube and CapLok tool/ Wrenches with the samples. CASSEN Testing Laboratories 6

Appendix A CapLok Tool/Wrenches Instructions Enclosed is a two-piece de-capping tool. Each piece has a groove into which the cap fits (see figure below). Placement of CapLok Tool: The sorbent tube is inserted into the slot of Part 1 so that the bottom of the cap fits snug in the groove. The cap should lock in place. The top of the tube cap is then slid into the groove of Part 2. Cap Removal: Holding Part 1 stationary, turn Part 2 counter-clockwise to loosen the twopiece cap. The cap can now be removed manually. Cap Replacement: Ensure the tube is seated properly in cap and seal finger tight. Then place the CapLok tool on the cap and turn Part 2 a ¼ turn clockwise. Visit our YouTube channel for tutorials! http://www.youtube.com/cassenlabs CASSEN Testing Laboratories

Appendix B Replacement Cost The sampling tubes and accessories have been designed and engineered to allow for high precision sampling, analysis, and storage. Please handle these items with care to ensure analytical accuracy. The replacement costs for damaged or lost items are: Stainless Steel Sorbent Tube: $115 each Hexagonal Cap: $15 each CapLok Tool: $70 Please call CASSEN Testing Laboratories at 1-866-423-3001 if you need assistance in assembling the sampling equipment. CASSEN Testing Laboratories

Field Notes CASSEN Testing Laboratories