PERFORMANCE EVALUATION OF PV VENTILATED GLAZING

Similar documents
The effect of shading design and control on building cooling demand

MODELLING BUOYANCY INDUCED FLOWS OF PASSIVE COOLING SYSTEMS Pedro Correia da Silva 1, Vítor Leal 1 and J. Correia da Silva 2

An enhancement of the daylighting from side-window using two-section venetian blind

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Introduction to basics of energy efficient building design

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

caused by subjective factors such as oversimplified modeling for simulation, nonuniform calculation methods, casual input parameters and boundary cond

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

AN APPLICATION OF BUILDING SIMULATION TECHNIQUES TO THE ASSESSMENT OF NATURAL VENTILATION IN OFFICE WITH DOUBLE SKIN FACADE

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

DAYLIGHTING DESIGN IN A LOW ENERGY BUILDING

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

SOMFY - PHILIPS Light balancing Whitepaper

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

( ) [1] [2, 3] [6] [2] [7, 8] [9] [10, 11]

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

COMFORT DRIVEN ADAPTIVE WINDOW OPENING BEHAVIOR AND THE INFLUENCE OF BUILDING DESIGN

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

MODELING FENESTRATION WITH SHADING DEVICES IN BUILDING ENERGY SIMULATION: A PRACTICAL APPROACH

The optimization of the mechanical night cooling system in the office building

The use of Simulation Software to Evaluate the Thermal Performance of Buildings in Brazil

INACCURACIES OF INPUT DATA RELEVANT FOR PV YIELD PREDICTION

125BEPM - Building energy performance modeling. Lecture handouts

THERMAL ANALYSIS OF A FACADE-MOUNTED PV ARRAY

MODELLING THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING PERFORMANCE OF AN OFFICE BUILDING IN SINGAPORE USING ENERGYPLUS

STUDY ON SIMULATION MODELLING STRATEGY FOR PREDICTING THERMAL ENERGY DEMAND PROFILES OF RESIDENTIAL COMPLEX

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Chapter 5 Glazing Properties

MODELLING THE URBAN MICROCLIMATE AND ITS INFLUENCE ON BUILDING ENERGY DEMANDS OF AN URBAN NEIGHBOURHOOD

OPTIMIZATION OF WINDOW-WALL RATIO FOR DIFFERENT BUILDING TYPES

Sustainable Building Design and Renewable Applications

IEA Annex 58: Full-scale Empirical Validation of Detailed Thermal Simulation Programs

Daylight, Solar Gains and Overheating Studies in a Glazed Office Building

Teaching building performance simulation - some quality assurance issues and experiences

optimize daylighting Opportunities

Ventilative Cooling potential tool

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Experimental and Simulation Study on the Performance of Daylighting in an Industrial Building and its Energy Saving Potential

Facade Design for Super High- Rise Building in Subtropic Region in China

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Energy Consumption Measurement of Energy-saving Buildings and Analysis of Simulation Example

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Student Modeling Competition

Assessment of shading devices with integrated PV for efficient energy use

Energy System Design and Optimization of a Solar Decathlon House

MODELLING THE ENERGY PERFORMANCE OF NIGHT-TIME VENTILATION USING THE QUASI-STEADY STATE CALCULATION METHOD

Glazed photovoltaic-thermal component for building envelope structures

Any correspondence concerning this service should be sent to The Strathprints Administrator:

Introduction of Heat Insulation Solar Glass

Solar Shading System Based on Daylight Directing Glass Lamellas

Application of Heat Insulation Solar Glass for Glass Buildings

Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions

SOLAR ENGINEERING OF THERMAL PROCESSES

Ventilated facade design in hot and humid climate. Ventilated facade design in hot and humid climate

Analysis of Indoor Luminous Environment and Power Generation by Roll Screen and Venetian Blind with PV Modules

CLIMATE BASED SIMULATION OF DIFFERENT SHADING DEVICE SYSTEMS FOR COMFORT AND ENERGY DEMAND. 6952, Switzerland Canobbio

External Environment and Indoor Microclimate

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Energy Efficiency / Renewable Energy (EE/RE) Projects in Texas Public Schools

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Energy saving through Building Envelope Innovation: Smart Skin Design

Great Ocean Rd Ice Creamery

Solar Home Design and Thermal Mass

Enhancing visual comfort in classrooms through daylight utilization

EFFECTS OF TREES ON THE ROOM TEMPERATURE AND HEAT LOAD OF RESIDENTIAL BUILDING. Tokyo, Japan

Available online at ScienceDirect. Energy Procedia 57 (2014 )

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Analysis 2: Alternative Thermal Window Design

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

INTEGRATING WHOLE BUILDING AIR LEAKAGE TEST DATA INTO ENERGYPLUS INFILTRATION MODELS

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

Influence Of Building Zoning On Annual Energy Demand

ESP-r: INTEGRATED SIMULATION TOOL FOR DESIGN OF BUILDINGS AND SYSTEMS

Design of Experiment for Solar Water Heater Performance Analysis

Design guidelines for direct ground cooling systems in different climates

Energy Efficient Museum Buildings

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

ResearcH JournaL 2011 / VOL

HEATING LOAD PREDICTIONS USING THE STATIC NEURAL NETWORKS METHOD. S.Sholahudin 1, Hwataik Han 2*

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

How to Design Zero Emission Buildings

An analysis of the contributions of lighting and climate to the architecture of Luis Barragán

DESIGN, MONITORING AND EVALUATION OF A LOW ENERGY OFFICE BUILDING WITH PASSIVE COOLING BY NIGHT VENTILATION

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

JGBFall06_b1Haase.qxd 12/29/06 4:33 PM Page 89 II RESEARCH ARTICLES

COMFORT-PRODUCTIVITY Building costs COMFORT-PERFORMANCE. Radiant Heating and Cooling Systems for Better Comfort and Energy Efficiency INDOOR - OUTDOOR

USE OF NET ZERO ENERGY SOLUTION SETS FOR THE REDESIGN OF THE NEW ZEALAND MERIDIAN NET ZEB BUILDING

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

AIC TECH 2015 Sustainability in Practice Turning Ideas into Reality Jan 16, 2015 FUTURE & NET ZERO BUILDINGS

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Using Radiant Cooled Floors to Condition Large Spaces and Maintain Comfort Conditions

Modelling Approaches for Displacement Ventilation in Offices

Transcription:

Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009 PERFORMANCE EVALUATION OF PV VENTILATED GLAZING Tin-tai Chow 1,*, Zhongzhu Qiu 2, and Chunying Li 1 1 Building Energy and Environmental Technology Research Unit, Division of Building Science and Technology, College of Science and Engineering, City University of Hong Kong, Hong Kong SAR, China 2 School of Energy and Environment Engineering, Shanghai University of Electric Power, Shanghai, China * Corresponding author: Tel: 852-27887622; Email address: bsttchow@cityu.edu.hk ABSTRACT This paper reports the simulation approach and prediction of annual energy performance of PV ventilated glazing systems with daylight saving as applying to typical office environment. Our computer model was developed via the ESP-r simulation platform in association with the RADIANCE lighting software. The new attempt of using indirect interaction between the two simulation programs through daylight coefficient, together with the coupled air-flow network and energy balance technique, has been proved very useful in tackling this kind of long period analysis. The simulation results show that for the range of climate regions from tropical to temperate, the PV natural-ventilated glazing system has advantages over the absorptive natural-ventilated glazing option as well as the single-pane glazing systems. INTRODUCTION With the growing interest in renewable energy applications in modern cities, the investigations into the potential use of photovoltaic (PV) products in buildings become popular. A PV glazing, for example, is composed of two layers of clear glass panes and in between, a number of opaque c-si solar cells connected in series. The electricity generation reduces the solar transmission through the window glass. Another advantage of the PV glazing is its natural light transmission since the spectrum of the transmitted light is almost identical to the incident light. The alternative use of semi-transparent solar cells in PV glazing can offer better scenery view and therefore more suitable for places where the people will stay longer. On the other hand, another approach to reduce solar transmission is the use of multi-pane window with airflow at the cavity, generally known as the ventilated window. Various combinations of glass sheets with top and bottom openings can be used. Compared with the single-paned window types, its distinct feature lies in the free or forced convection behaviour between the layers of glasses that form the cavity. A natural-ventilated semi-transparent solar cell incorporated glazing system (D-PV) is shown in Figure 1, with a PV glass sheet as the external pane (complete with intake and discharge louvers) and a clear glass sheet as the internal pane. In order to evaluate numerically its long-term energy performance as compared to the conventional window systems, a simulation method has been developed for the task. The following introduces our approach and the findings. outdoor PV glass incident solar radiation natural convection thermal radiation & convection To inverter & electric load air flow Figure 1 Cross-sectional view of natural ventilated PV glazing and energy flow paths. SIMULATION METHOD indoor clear glass thermal radiation & convection thermal radiation exchange solar transmission Simulation task The task was to predict the electricity consumptions of the air conditioning (AC) and lighting systems for different glazing configurations in the office environment. The annual performance of the following four glazing systems with and without daylight control were analyzed: (i) single-pane absorptive glazing (S-AB), (ii) single-pane PV glazing (S-PV), (iii) natural-ventilated double PV glazing (D-PV), and - 258 -

(iv) natural-ventilated double absorptive glazing (D- AB). (a) Bangkok (b) Hong Kong (c) Shanghai Figure 2 Variation of TMY ambient temperature ( o C) in Bangkok, Hong Kong and Shanghai. Their integrative energy performance at three different modern Asian cities, i.e. Bangkok, Hong Kong and Shanghai were evaluated in turn. Bangkok (at 13 o N latitude) represents the tropical climate, Hong Kong (at 22 o N latitude) the subtropical climate, and Shanghai (at 31 o N latitude) the temperate climate regions. Their Typical Meteorological Year (TMY) weather files from the EnergyPlus website were adopted, and the simulations were performed over the 8760-hour period. Figure 2 shows the annual variations of ambient temperature of these three cities. In Bangkok, the temperature variation is relatively stable and the yearly average temperature is 28.5 o C. This is different from Hong Kong and Shanghai, where show distinct summer and winter periods. Amongst the three, Shanghai is the only city having ambient temperature occasionally lower than the ice point. The yearly average temperatures for Hong Kong and Shanghai are 23.1 o C and 16.3 o C respectively. Simulation tools In a ventilated glazing model, it is required to predict the airflow in the air cavity. This can be achieved by either one of the following two methods: (i) CFD simulation, or (ii) coupled air flow network and energy balance simulation. The CFD approach is impracticable to run whole-building simulations for an extended period of 8760 hourly steps. The coupled air-flow network and energy balance technique was therefore employed. Three simulation programs were used in this study, namely WINDOW, ESP-r and RADIANCE. A brief description of their applications is given below. (i) WINDOW Developed at the Lawrence Berkeley National Laboratory (LBNL), WINDOW (2003) can be used for determining the thermal and solar optical properties of window systems. It is composed of a series of libraries that almost cover the whole range of glazing properties. In particular, the Glass Library holds the thermal and optical properties of glazing materials, in that the total solar, visible and thermal infrared optical properties of a glazing system, as well as the thickness and thermal conductivity, are displayed. The glazing properties in the present work were obtained from this library. (ii) ESP-r ESP-r (ESRU 2002) is capable of simulating the building thermophysical processes within thermal zones, surface heat transfer regimes within rooms and with outside surfaces, 3D conduction within and between surfaces, and long/short wave radiation exchange between surfaces in rooms and with the outside environment. Apart from the above mentioned, the treatment of airflows between thermal zones based on nodal network airflow modelling is allowable (Clarke 2001). In the present study, the ventilated glazing system was divided into six thermal zones, as shown in Figure 3, in order to examine the airflow condition. The upper and lower openings were set as specific airflow openings, and the six thermal zones were set as constant-volumeflow components. In ESP-r, the airflow network method is to solve for the steady fluid flows within a network of connected pressure points (nodes) when subjected to successive sets of boundary conditions. In other words, the problem reduces to the calculation of mass flows through each connection when the nodes represent internal (unknown) and external (known) pressure conditions. Thermal zones are taken as internal nodes and the openings set as - 259 -

boundary/excitation nodes, which are dictated by the input thermal properties and weather file. Solution for any unknown internal node is obtained by an iterative approach in which the unknown nodal pressures are repeatedly adjusted considering wind and buoyant effects, until the nodal mass imbalances are within the tolerance limit. Ambient environment (a) Direct method Ambient environment Figure 3 Simulation airflow network of D-PV window. (iii) RADIANCE The lighting simulation engine of RADIANCE (1994) uses a hybrid approach of Monte Carlo and deterministic ray tracing to achieve a reasonably accurate solution within affordable time. The computation starts at a measurement point (usually a viewpoint) and traces rays of light backwards to the sources (i.e. emitters). The calculation procedures can be divided into three main parts: the direct component, the specular indirect component, and the diffuse indirect component. In addition, a secondary light source calculation may be performed for windows, skylights or other illumination "portholes". This is important when the focus is on indoor luminance condition with daylight transmitting through windows. Interactive use of ESP-r and RADIANCE In order to realize the daylight control function, and at the same time, to take the lighting load reduction to the space thermal load into account, ESP-r and RADIANCE were used interactively, in that RADIANCE calculated the luminance distribution while ESP-r exercised the artificial lighting electricity consumption control according to the indoor luminance distribution. There can be two methods for the integration: (i) direct, and (ii) indirect. The processes of these two methods are illustrated in Figure 4. (b) Indirect method Figure 4 Interaction of ESP-r and RADIANCE. (i) Direct method In the direct interaction approach, ESP-r acts as the simulation controller and integrator. At each simulation time step (when the lighting control is active and daylight is available) the ESP-r parent process initiates a child lighting simulation RADIANCE process in the foreground. This causes the parent process to stop and wait until the child process finishes (Janak 1997). With this method, each time step will accomplish with a lengthy computation period. When studying the daylight - 260 -

condition for a year-long period, the extremely heavy computation load makes the simulation an almost impossible task. (ii) Indirect method The conception of daylight coefficients (DC), which has brought into consideration the changes in the luminance of the sky elements, offers an effective way of computing indoor daylight luminance under various sky conditions and solar positions (Tregenza and Waters 1983). The DC approach is able to give more accurate results than the traditional daylight factor (DF) method, especially for internal spaces (Reinhart and Herkel 2000). This, together with the coupled air-flow network and energy balance, has the potential to simulate lengthy period, as in our case. So in our study, the indirect coupling method was adopted. Figure 5 Perspective view of the office model. ANNUAL ENERGY EVALUATION Building description The length and width of the typical office flat in a multi-storey building were both 40.8m, with a floorto-floor height of 3.6m. The 1665 m 2 floor area was divided into five zones, i.e. South, East, North, West and Central. A perspective view of the flat is given in Figure 5. Adiabatic ceiling and floor slabs were assumed. The key building parameters are listed below. (i) Building envelope Absorptance of wall = 0.7 Window-to-wall ratio = 0.6 U-value of opaque external wall = 2.43 W/m 2 C U-value of internal partitions = 4.02 W/m 2 C (ii) Space load conditions Space air temperature settings: 24 C (summer) 21 C (winter) Equipment load = 10 W/m 2 Lighting load = 20 W/m 2 (maximum) Occupant density = 13 m 2 /person Infiltration rate = 0.2 ACH Daylight control Daylight control was applied at the perimeter zones (within 4-meter distance from the external wall). These zones represented 48% of the total usable area. The daylight control was assumed operating for 24- hour a day. As shown in Figure 6, the sensors were located at a 4m distance to the external wall and on the working plane level. Whenever the luminance level was above 882 lux at the sensor, the artificial lighting would be 100% switched off. If the luminance was between 630 and 882 lux, 90% lights would be switched off. In case the luminance was below 630 lux, then the percentage of lights switched off would vary linearly and inversely with the luminance level, until it reached 100% on at 0 lux. Figure 6 Locations of the luminance sensors. 90000 80000 70000 S-AB; D-AB; S- PV; D-PV Yearly electricity consumption for lighting (kwh) S-AB-d S-PV-d D-PV-d D-AB-d SIMULATION RESULTS Electricity consumption on lighting Without daylight control, electricity consumptions on artificial lighting were the same in all four window cases (S-AB, D-AB, S-PV and D-PV) for different cities, because of the same design illumination and operation schedule (see Figure 7). For the cases with daylight control (marked with suffix d ), the energy saving potentials were all different - the highest was found in Bangkok and the lowest in Shanghai. This reflects that the lower the latitude, the more solar irradiance can be used as natural light source and more electricity on artificial lighting can be saved. Within the same city, the cases of S-AB-d and D- HK Bangkok Shanghai Figure 7 Annual electricity consumption (kwh) for lighting. - 261 -

AB-d were found able to utilize more sunlight than the cases of S-PV-d and D-PV-d. The percentages of light-energy saving through daylight control in the absorptive glazing configurations are thus higher than the PV glazing configurations. Also, the single glazing configurations can save more light-energy than double glazing configurations. This is owing to their higher transmissivity characteristics. 500 400 300 200 (a) Hong Kong load patterns are similar. In winter, the cooling load of Bangkok was found to be almost the same as in summer. The cooling load of Hong Kong in winter was about half of that in summer, while in Shanghai, this percentage was found only around 10% to 20%. One merit of using daylight control is the save in cooling energy through the cut in lighting load. From Figure 9, it can be seen that for the three cities, the effect of glazing configuration on cooling load saving is similar. The cooling loads for all PV glazing configurations were substantially reduced, no matter there was daylight control or not. The base case S- AB has the highest annual cooling load demand, the D-PV glazing requires the least, whereas those of the D-AB and S-PV glazing configurations are between these extremes. 100 0 S-AB S-AB-d S-PV S-PV-d D-PV D-PV-d D-AB D-AB-d Heating load with different glazing constructions (HK;kWh) 390000 340000 290000 HK Shanghai Bangkok 240000 13000 190000 12500 12000 11500 (b) Shanghai 140000 S-AB S-ABd S-PV S-PVd D-PV D-PVd D-AB D-ABd Cooling load with different glazing constructions (kwh) 11000 Figure 9 Annual space cooling load (kwh). 10500 10000 S-AB S-AB-d S-PV S-PV-d D-PV D-PV-d D-AB D-AB-d Heating load with different glazing constructions (Shanghai; kwh) Figure 8 Annual space heating load (kwh) for Hong Kong and Shanghai. 220000 200000 180000 160000 HK Shanghai Bangkok Electricity consumption on space heating In the subtropical Hong Kong, space heating was required in some winter morning hours, due to the lower air temperature overnight. As for Shanghai, the air temperature of the whole January was below 10 o C, and the heating demand was therefore high. The space heating load of Bangkok was found zero throughout the typical year. Comparatively, the heating period of Shanghai was found longer than Hong Kong. There were heating loads in five months for Hong Kong: from November to March next year. The office in Shanghai required for space heating one month earlier, i.e. from October onwards. From Figure 8, it can be seen that the D-AB configuration was able to provide best heat preservation and consumed the least heating energy for both Hong Kong and Shanghai. Space cooling load In summer, the ambient temperature is the highest in August for all three cities. As a result their cooling 140000 120000 S-AB S-ABd S-PV S-PVd D-AB D-PV D-PVd D-ABd Cooling load with different glazing constructions (kwh) Figure 10 Annual electricity consumption (kwh) for AC and lighting systems. PV electricity output The annual electricity generation performance for S- PV glazing is summarized in Table 1. The results were based on the algorithm developed from the JOULE project PV-HYBRID-PAS (Clarke et al. 1998) funded by the European Commission. It can be seen that the PV-glazing has the best electricity output in Bangkok. Hong Kong and Shanghai have the similar reduced levels of output at around 70%. The D-PV cases had very similar performance to the S-PV cases with the difference in outputs less than 1%. - 262 -

Table.1 Annual electricity production (kwh) of S-PV glazing configuration for different zones and cities South East North West Total Percentage (%) Bangkok 3,894 3,061 1,732 4,389 13,080 100 Hong Kong 2,977 1,981 1,034 3,186 9,178 70 Shanghai 3,464 2,067 9,10 2,988 9,428 72 Table 2 Yearly AC system and lighting electricity consumption (kwh) with different glazing configurations S-AB S-AB-d S-PV S-PV-d D-PV D-PV-d D-AB D-AB-d Bangkok 220,200 200,500 188,700 179,700 180,700 174,100 207,600 190,100 Percentage (%) 100.0 91.0 85.7 81.6 82.0 79.1 94.3 86.3 Hong Kong 179,400 163,600 159,100 152,700 154,300 148,900 172,400 158,700 Percentage (%) 100.0 91.2 88.7 85.1 86.0 83.0 96.1 88.4 Shanghai 155,500 141,300 137,000 131,100 133,800 128,800 150,600 138,000 Percentage (%) 100.0 90.8 88.1 84.3 86.0 82.8 96.8 88.8 Electricity consumption of AC and lighting systems Table 2 summarizes the overall annual electricity consumptions of the above glazing systems. The results were based on the AC system COP (coefficient of performance) of 3.0 for cooling and 4.0 for heating. The PV electricity generation was assumed fully consumed in the office building. The electricity consumption of AC and lighting systems in Bangkok was found relatively stable throughout the year. For Hong Kong and Shanghai, the electricity consumption in summer (especially in August) was found to be almost twice of those in winter. For all the three cities, the office flat had the least overall electricity consumption when the D-PVd glazing (natural ventilated double PV glazing with daylight control) system was used. Compared with the base case (S-AB glazing), the energy saving potentials were found 21.9%, 17.0% and 17.2% for Bangkok, Hong Kong and Shanghai respectively. CONCLUSION Using daylight control and novel glazing configurations such as PV ventilated glazing systems can improve significantly the electricity consumption in office buildings. These effects have been investigated through numerical simulation with ESPr software at three cities: Bangkok, Hong Kong and Shanghai. The simulation approach and the results have been discussed. The mixed use of indirect interaction between ESP-r and RADIANCE via daylight coefficient, together with the coupled airflow network and energy balance technique, was proved to be very useful in tackling this kind of annual analysis. The simulation results indicate that for the range of climate regions from tropical to temperate, the natural-ventilated double PV glazing system has the highest energy saving potential and thus this is worthy for further analysis. ACKNOWLEDGEMENT The work described in this article was fully supported by a grant from the Research Grants Council of the Hong Kong Special Administrative Region, China (Project No. CityU 112107).. REFERENCES Clarke, J. A. 2001. Energy Simulation in Building Design, 2 nd ed., Butterworth Heinemann, Oxford. Clarke, J.A., Hand, J.W., Janak, M., Johnstone, C.M., Strachan, P.A. 1998. PV-HYBRID-PAS Final report: Modelling Annex Report 6 on Simulation Case Study: Elsa Building, Ispra, Italy, JOULE III, PASLINK EEIG Contract JOR3-CT96-0092. ESRU. 2002. The ESP-r System for Building Energy Simulation User Guide Version 10 Series, ESRU manual U02/1, University of Strathclyde, Energy Systems Research Unit, Glasgow, Scotland. Janak, M. 1997. Coupling building energy and lighting simulation, Building Simulation 97, Proceedings of the 5th International IBPSA Conference, Prague, Czech Republic, pp. 313 319. RADIANCE. 1994. The RADIANCE lighting simulation software, http://caad.arch.ethz.ch/ CAAD/ray. Reinhart, C.F., Herkel, S. 2000. The simulation of annual daylight illuminance distributions a state-of-the-art comparison of six RADIANCE based methods, Energy and Buildings, 32(2):167 87. Tregenza, P.R., Waters, I.M. 1983. Daylight Coefficients, Lighting Research and Technology, 15(2):65 71. Window. 2003. Window 5.2 Knowledge Base, http:// windows.lbl.gov/software/window/window.html. - 263 -