General Specifications COMPLETE PRODUCT LINE SINGLE HUNG LMI, SMI HORIZONTAL ROLLER LMI - SMI FIXED WINDOW LMI, SMI ARCHITECTURAL WINDOWS LMI FRENCH DOOR LMI SLIDING GLASS DOOR LMI MULL BARS AND MULL CLIPS HEAVY SLIDING GLASS DOOR SMI CASEMENT LMI STOREFRONT SYSTEM LMI PERFORMANCE TESTING Miami-Dade Protocols PA/TAS 201, 202, 203 Large and Small impact Tests ASTM E547/E331 Water penetration ASTM E283 for air leakage Windows AAMA 1302.5 and door AAMA forced entry resistance Deglazing test (ASTM E987) Uniform Design and Structural load test (ASTM E330) FRAMES Extruded aluminum with electrostatic wet paint (PPG Polycron and Duranar ) and anodized finishes in a wide variaty of colors. Flange-type for masonry or wood construction or flush frames for concrete opennings Corrosion-resistant hardware and fasteners with stainless steel options Windows and doors members are extruded from a minimum of 6063-T5 and/or 6063-T6 and 6005-T5 aluminum alloy. GLAZING All LMI products are silicone-glazed for greater strength and seal DuPont Butacite and DuPont SentryGlas available Heat strengthen or annealed glass configuration available, Heat strengthen glass as a standard WEATHERSTRIPPING Fully weather-stripped with plastic fin, Q-LON and/or vinyl bulb SCREENS Window and door screens are fitted at time of assembly to ensure a complete unit Aluminum frame, fiber glass mesh NOA S AND TEST All products are Dade County Approved Dade County NOA # subjets to change as renewals occur Test data available upon request All products are FBC Approved OPTIONS Applied Muntins (Flat or OG Interior and Exterior) Popular Glass tints Sizes: Standard, modular and costum sizes will take the same delivery time Finish: white, bronze, anodized. Ask your distributor for more PPG colors Blue Max protection available (one side or both) Flush frame adapter available for buckless instalation *Version 03 June 2008
Typical jamb Typical head and sill Flush frame adapter
SPECIFICATIONS: Large Missile Impact: Glass on glass: (1/8 HS+0.090 DuPont Butacite + 1/8 HS) Another glass options tested Dade County Notice of Acceptance 06-0316.02 Design load (ASTM E330) + 80.0 psf; -90 psf Water infiltration 10.5 psf Maximum size approved in NOA: 42 x 74 1/4 (equal lites) Frame has a depth of 2.33 Pending on the sizes, glass configurations and loads may vary Testing by FTL (Fenestration Testing Laboratory Inc., Hialeah Fl.) Unequal lites (oriel) approved Block & Tackle and Ultra lift Balances Side view detail Small Missile Impact: Glass on glass: (5/32 HS + 0.090 DuPont Butacite + 5/32 HS) Dade County Notice of Acceptance 06-0316.03 Design load (ASTM E330) + 80.0 psf; -120 Water infiltration 12 psf Block & Tackle and Ultra lift Balances Frame has a depth of 2.33 Testing by HETI (Hurricane Engineering & Testing Inc., Miami Fl) Maximum size approved in NOA: 53 1/8 x 74 1/4 (equal lites) Unequal lites (oriel) approved Vent latch Top view detail
74 1/4 75 1/4 76 3/4 74 1/2 16 H36 26 2064 2864 3464 LMI Minimum width to meet egress (standard sill) = 32 13/16 x 74 1/4 LMI Minimum height to meet egress (standard sill) = 40 1/4 x 61 LMI Minimum width to meet egress (hi-rise sill) = 33 1/16 x 74 1/4 LMI Minimum height to meet egress (hi-rise sill) = 40 1/4 x 61 5/8 SMI Minimum width to meet egress = 33 1/16 x 74 1/4 SMI Minimum height to meet egress = 40 1/4 x 61 5/8 * Openings calculated using 1/4 shim space
SPECIFICATIONS: Side view detail Large Missile Impact: Glass on glass : 3/16 HS + 0.090 DuPont Butacite + 3/16 HS Another glass options tested Dade County Notice of Acceptance 06-0308.05 Design load (ASTM E330) + 70 psf; - 80 psf Water infiltration 15 psf Maximum size approved 36 x 120 Frame has a depth of 2.33 Pending on the sizes, glass configurations and loads may vary Testing by FTL (Fenestration Testing Laboratory Inc. Hialeah Fl). Architectural available Minimum curving radius for architectural systems is 9 Minimum curving radius for applied muntins is 7 Small Missile Impact: Glass on glass: 3/16 TEMP + 0.090 DuPont Butacite + 3/16 HS Another glass options tested Dade County Notice of Acceptance 05-1213.01 Design load (ASTM E330) + 90 psf; - 90 psf Water infiltration 15 psf Maximum size approved 36 x 120 Frame has a depth of 2.33 Testing by HETI (Hurricane Engineering & Testing Inc., Miami Fl). Pending on the sizes, glass configurations and loads may vary. Top view detail
SPECIFICATIONS: Large Missile Impact: Glass on glass : (1/8 HS + 0.090 DuPont Butacite - 1/8 HS) Another glass option tested Dade County Notice of Acceptance 06-0316.05 Design load (ASTM E330) + 70 psf; - 90 psf Water infiltration 10.5 psf Maximum size tested 108 x 60 XOX Configurations: XO or OX, XOX XOX Configurations are 1/3-1/3-1/3 or 1/2-1/4-1/2 Pending on the configuration sizes, glass options and loads may vary Frame has a depth of 2.33 Testing by FTL (Fenestration Testing Laboratory Inc., Hialeah Fl). Vent latch Small Missile Impact: Glass on glass: (5/32 HS + 0.060 DuPont Butacite + 5/32 HS) Dade County Acceptance 06-0316.04 Design load (ASTM E330) + 82 psf; - 82 psf Water infiltration Low standard 11 psf; High sill 12.3 psf Maximum size tested 111 x 63 XOX Configurations: XO or OX, XOX XOX Configurations are 1/3-1/3-1/3 or 1/2-1/4-1/2 Frame has a depth of 2.33 Testing by HETI (Hurricane Engineering & Testing Inc., Miami Fl). Side view detail Top view detail
Top view detail Side view detail
74 75 76 1/2 73 3/4 63 64 64 63 1/4 LMI Minimum width to meet egress = 49 1/8 x 47 7/8 LMI Minimum height to meet egress = 74 x 32 1/8 SMI Minimum width to meet egress = 49 1/8 x 48 5/16 SMI Minimum height to meet egress = 74 x 32 9/16 * Openings calculated using 1/4 shim space
72 73 74 1/2 72 1/4 60 61 62 1/2 60 1/4 LMI Minimum width to meet egress = 49 1/8 x 47 7/8 LMI Minimum height to meet egress = 74 x 32 1/8 SMI Minimum width to meet egress = 49 1/8 x 48 5/16 SMI Minimum height to meet egress = 74 x 32 9/16 * Openings calculated using 1/4 shim space
106 3/8 107 3/8 108 7/8 106 5/8 LMI Minimum width to meet egress = 94 7/8 x 47 7/8 LMI Minimum height to meet egress = 108 x 42 SMI Minimum width to meet egress = 94 7/8 x 48 5/16 SMI Minimum height to meet egress = 108 x 42 7/16 LMI Minimum width to meet egress = 75 x 47 7/8 LMI Minimum height to meet egress = 108 x 33 5/16 SMI Minimum width to meet egress = 75 x 48 5/16 SMI Minimum height to meet egress = 108 x 33 3/4 * Openings calculated using 1/4 shim space
Side view detail Hardware optional Flush bolt Top view detail
Side view detail Top view detail Side view detail Top view detail
Minimum width for 32 clearance X = 36 1/2 XX = 67 Structural mullion required when installing transom over French door with side lites. OG/Flat muntins available
Outside pull Inside handle Retainer clip Fixed panel clip and bumper Side view detail
XO - OX - OXO Sliding Glass Door ES 4000 Top view detail Top view detail
Top view detail *Steel reinforcements Top view detail
Minimum width for 32 clearance 2 panels = 72 3 panels = 108 3/4 4 panels = 142 3/4
Typical Typical head and sill Typical jamb
Locking cam
Storefront System ES8000 SPECIFICATIONS: Large Missile Impact: Glass on glass: (1/4 HS+ 0.09 DuPont SentryGlas + 1/4 HS) Dade County Notice of Acceptance 08-0204.06 Design loads (ASTM E330) WITHOUT INTERMEDIATE HORIZONTALS NOMINAL DIMS 32" 36" 42" 48" 120 EXT(+) -INT(-) 130 130 117.5 104.1 WITH INTERMEDIATE HORIZONTALS NOMINAL DIMS 32" 36" 42" 48" 120 EXT(+) -INT(-) 130 130 112.8 98.7 Water infiltration 19.5 psf Maximum size approved 48 X 120 Frame has a depth of 5 Testing by FTL (Fenestration Testing Laboratory Inc. Hialeah FL) Architectural Available Minimum Curving radius for architectural system is 20
Storefront System ES8000 Top view detail 2 Panel (LITE) configuration Top view detail 3 Panel (LITE) configuration
SPECIFICATIONS: *Mullions available 1 x 4 x 1/8 1 x 4 Custom 2 x 3 x 1/8 2 x 5 x 1/8 2 x 6 x 1/4 (Heavy Mullion) Other mullions approved on NOA: 1 x 3 x 1/8 1 x 3 Custom 2 x 4 x 1/8 2 x 6 x 1/8 *NOA No. 04-0712.01
951 NE 167 ST Suite 207 Miami, Florida 33162 Phone: 305 249 0840-41 Fax: 305 249 0842 www.eswllc.com customerservice@eswllc.com Avenida Circunvalar a 100 mts de la Vía 40 Barrio Las Flores Barranquilla - Colombia PBX: (5-75) 366 4600 Fax: (5-75) 3773189 www.energiasolarsa.com