Similar documents
ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

Sliding Patio Doors Brickmould Vinyl

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Vinyl Windows and Doors

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

Fusion Welded, Maintenance Free, All Vinyl Frame and Sash Construction Energy Efficient ¾ Insulated Glass Standard Available Sizes: (Tip to Tip Frame

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

OSHA (e) (8) Impact Performance Testing to show compliance with OSHA (a) (4) & OSHA 29 CFR (b)(4)(i)

6110 Horizontal Sliding Windows

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

Series Heavy Commercial Projected Window

Milgard Double Bypass Horizontal Sliding Windows SERIES QUIET LINE VINYL JANUARY Min Max

Engineered Specifically for New Construction Applications

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

Series 510-I Thermal Heavy Commercial Projected Window

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

Awning Windows Montecito New Construction Window

VINYL SINGLE HUNG WINDOW

Maximize your security, protection and energy efficiency

Casement Windows Montecito New Construction Window

SECTION ALUMINUM STORM WINDOWS

7520 Casement Windows

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

WINDOW TECH SYSTEMS, INC. 3 ¼ HORIZONTAL SLIDING & FIXED ALUMINUM WINDOWS SPECIFICATIONS

WINDOW TECH SYSTEMS, INC.

Picture/Radius Windows Montecito New Construction Window

Vinyl Replacement Windows and Doors

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

New Construction Windows and Doors

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Veka Evolutions Commercial Window Program

Exceed Your Expectations Today And Well Into the Future.

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

En e r g e x El i t e Window Systems

ARCHITECTURAL SPECIFICATIONS. Section Master Format Section

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

Model 4000-IM Single Hung H-C x 2300 (56 x 91 )

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

SWING DOOR SPECIFICATION

Richlin 500 Casement. Hayfield Window & Door HAYFIELD, MN 55940

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Georgetown Series windows and doors are designed not only for beauty, comfort, and energy-efficiency they re also virtually maintenance-free.

NORTH TONAWANDA CSD Capital Projects 2015

TMS 114 XT TECHNICAL MANUAL

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

SERIES 8520 AW-PG80-AP PROJECT-OUT AWNING WINDOW

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

MikronWood Thermal Advantage Composite Window System Ideal for new construction and replacement applications in colder temperature climates

PREMIUM VINYL WINDOWS AND DOORS FOR REPLACEMENT

THE ULTIMATE HIGH PERFORMANCE NEW CONSTRUCTION WINDOWS AND PATIO DOORS

Model 8000 Double Hung H-C x 2311 (56 x 91 )

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

System WV410 Storefront Window System

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS)

WESTECK WINDOWS and DOORS

Impact-Resistant Windows and Doors. impact-resistant package

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

CLEARVIEW CATALOG PARTS AND ACCESSORIES MASON CORPORATION

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

Quality. Care. Commitment. series 8000 doors supreme quality

BUT THEN AGAIN, SO DO WE.

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

The Alternative to Storefront. Gerkin Model 58F

opus II efficiency weather tightness durability lity energy efficiency weather tightness er tightness durability energy efficiency royalplast.

SERIES 5500 H-HC60 DOUBLE-HUNG TILT WINDOW

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

Embrace the long shadows of the late afternoon. Embrace your sense of style. Embrace the compliments with just a touch of humility.

DIVISION 8 OPENINGS SECTION ALUMINUM WINDOWS

Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

VINYL CLASSICS NORTHERN CLASSICS

THERMALLY BROKEN STEEL WINDOWS STEEL WINDOW INSTITUTE A STANDARD OF EXCELLENCE

SECTION ALUMINUM WINDOWS

REBCO ALUMINUM WINDOWS

Series x Thermal Triple Set Storefront Framing

Refurbishing vs. Replacing Commercial Windows: Why, When, and How

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Window Installation Instructions: Sliding Window Systems with Frame Master Receptor

Double Hung. The Window Nation Story

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

HomeMaker3 Windows and Doors

Designing windows that deliver both structural strength and thermal protection is our job. Doing it with style is our pleasure.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Transcription:

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 TABLE OF CONTENTS 1. PROJECT DATA...1 2. SUMMARY...1 3. TEST SPECIMEN...1 4. IMPACT ACCEPTANCE CRITERIA...3 5. PERFORMANCE RESULTS...3 6. DISCLAIMER.....4 APPENDIX APPENDIX A: DECEUNINCK NORTH AMERICA 142.094 SH - 003 PVC SINGLE HUNG TILT WINDOW DRAWINGS Refer to Appendix A. This report is not complete unless these drawings are stamped and initialed by CCLI as illustrated below. DRAWING/DETAIL SHEET DATE STAMPED AS ILLUSTRATED BOM / Layout Main Frame 10008675_SH 06/03/99 Head Frame 10008676_SH 06/07/99 Sill Frame 10008672_SH 06/18/02 Lift Rail 10008882_SH 08/04/97 Lock Rail 10008895_SH 02/08/94 Meeting Rail 10008511_SH 08/27/03 Glazing Bead 10005470_SH 06/01/93 Bulb Seal 10008206_SH 06/12/97 Sash Reinforcement 10300082 08/24/06 Meeting Rail Reinforcement 10300084 04/21/05 Sill Reinforcement 10300096 08/14/06 S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 1. PROJECT DATA Page 1 of 5 Project: ASTM E 1886-1996 Date of Testing: June 8, 2011 Tested For: Deceuninck North America 351 North Garver Road Monroe, OH 45050 Witnessed By Deceuninck North America Construction Consulting Laboratory, International (All or Partial Viewing) Jonathan Morton Chevis Wilson 2. SUMMARY Series Product Type Test Size Positive DP Negative DP 142.094 SH - 003 Single Hung 3'-8" x 7'-0" 3120 Pa (65.0 Psf) 3120 Pa (65.0 Psf) 3. TEST SPECIMEN Product Type: PVC Single Hung Tilt Window, Product Drawings, Appendix A Series Model: Series 142.094 SH - 003 Single Hung Tilt Window Specification 1886-05 1996-05B Test Methods: 1996-05b Wind-Zone 4 ASTM E 1886-05 +/-3120Pa (+/-65.0 Psf) Frame Size: 1119 x 2134 (3'-8 1 /16" x 7'-0") (44.0625" x 84") Sash Size: 860 x 892 (3'-4 13 /16" x 2'-11 1 /8") (40.8125" x 35.125") Fixed DLO: 984 x 1130 (3'-2¾" x 3'-8½") (38.750" x 44.500") Sash DLO: 962 x 826 (3'-1 7 /8" x 2'-8½") (37.875" x 32.500") Configuration: O/X Weather-Stripping: Pile weather strip with plastic center fin 4.75mm x 7.36mm (0.187" x.290" backed) at the exterior face of sash top rail and stiles pile also located at the lateral face of sash stiles. Pile weather strip with plastic center fin 4.75mm x 7.36mm (0.187" x.290" backed) at the interior face of frame sill interior leg. Foam bulb (.375" x.300") located at sash bottom rail. S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 Page 2 of 5 Weep Arrangement: Screen track weeped by 9.53mm x 3.175mm (1" x 1 /8") slot spaced 39.69mm (1 9 /16") from each end. Sash glass pocket weeped with one (1) 9.53mm x 4.76mm ( 3 /8" x 3 /16") punched weep through both legs spaced 82.55mm (3¼") from each end. Fixed meeting rail weeped with one (1) 2.38mm ( 3 /32") weep hole punched through both legs spaced 82.55mm (3¼") from each end. Hardware: Metallic cam action locks 203.2mm (8") from each end of sash top rail, attached by two (2) #8 x 19.05mm (¾") PFH screws with keepers at fixed interlock attached with two (2) #8 x 12.7mm (½") PFH screws. Metallic spring loaded tilt latch at each end of sash top rail. Metallic pivot bar at each end of sash bottom rail attached with one (1) #8 x 9.52mm ( 3 /8") screw per bar. Metal snubbers located at the underside of bottom rail and frame sill 381mm (15") from each end, attached with #8 x 12.7mm (½"). Reinforcement: 6005-T5 aluminum extrusion part #10300082 located at sash stiles, lift rail and lock rail. 6005-T5 aluminum extrusion part #10300084 located at fixed meeting rail. Reinforcement part #10300096 located at frame sill. Impact Glass: Sealed insulating glass: One piece, 3.17mm ( 1 /8") DSB annealed glass at the exterior with 7.24mm (.285") airspace, two pieces 3.17mm ( 1 /8") DSB annealed glass with 2.286mm (.090") Solutia PVB laminate at interior, 19.05mm (¾") overall thickness. Glass insulated with warm edge air spacer. Glazing: Sash lite is exterior glazed with Sika 552 polyurethane back bedding compound at interior, full perimeter and rigid vinyl snap-in glazing bead at exterior of glass. Fixed lite is interior glazed with Sika 552 polyurethane back bedding compound at exterior, full perimeter and rigid vinyl snap-in glazing bead at interior of glass. Installation Features: Frame nail fin was attached to SPF, nominal 50.8mm x 101.6mm (2" x 4") test buck w/silicone and (2") 6d penny nails through fin spaced 152.4mm (6") from each end and approximately on 152.4mm (6") centers, full perimeter. Other Features: Frame and sash corners are mitered and welded. Frame sill also attached to frame jambs with one (1) #8 x 19.05 ( ¾") PPH per corner. Fixed interlock rail reinforcement attached to jambs with one (1) #8 x 76.2mm (3") truss head screw at each end. Fixed interlock rail anchor part #79543 w/gasket attached to jambs with #8 x 25.4mm (1") PFH. S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 Page 3 of 5 4. IMPACT ACCEPTANCE CRITERIA The test specimen shall resist the large missile impact with no tear formed longer than 5" (130mm) and wider than 1mm ( 1 /16") through which air can pass or no opening formed through which a 3" (76mm) diameter solid sphere can freely pass when evaluated upon completion of missile impacts and test loading program. 5. PERFORMANCE RESULTS Title of Test Test Method Measured Allowed 5.3.1.1 Operating Force Open 71N (16.0 lbs) 135N (30 lbs) Close 85N (19.0 lbs) 135N (30 lbs) 5.3.1.1.3 Latching Devices 22N (5.0 lbs) 100N (22.5 lbs) 5.3.4.3 Uniform Load Structural ASTM E 330-02 4680 Pa (97.5 psf) Positive Deflection 19.05mm (.75") No Damage 4680 Pa (97.5psf) Negative Deflection 15.24mm (.60") No Damage -Permanent Set.76mm (.03") 5.91mm (0.233") Specification: ASTM E 1996-05b Missile Level Type D (#2 yellow pine weighing 9 lbs 2 ozs and measured 8'-3" overall). Test Specimen 1 ASTM E 1996-05b Par No Speed Rotation Title of Test Measured Allowable 5.3.1.1 50.1 fps 0º Center of Sash Glass No Penetration No Penetration 5.3.2.1 50.3 fps 0º Upper Right Corner No Penetration No Penetration Test Specimen 2 Par No Speed Rotation Title of Test Measured Allowable 5.3.1.2 51.3 fps 0º Lower Left Corner No Penetration No Penetration 5.3.2.2 50.2 fps 0º Center of Sash Glass No Penetration No Penetration Test Specimen 3 Par No Speed Rotation Title of Test Measured Allowable 5.3.1.3 51.0 fps 0º Upper Right Corner No Penetration No Penetration 5.3.3.6 50.7 fps 0º Center of Interlock No Penetration No Penetration S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 Page 4 of 5 Test Specimen 1 Test Specimen 2 Test Specimen 3 - Indicates 2 nd impact to specimen. The laboratory temperature was recorded at 85ºF for the duration of testing. Test specimens were stored in the lab prior to testing and the skin temperature of the vinyl was recorded at 85ºF. Visual inspections performed on the test specimens revealed there were no penetrations through the laminate and no separation of vision-to-frame glazing at the conclusion of the large missile impact tests. Specification: ASTM E 1886-05 Load 3120 Pa 65 PSF Positive Load 3120 Pa 65 PSF Negative Sequence Range Cycle Time Cycles Average Deflection Cycle 1 0.2 P to 0.5 P < 3 seconds 3500 9.40mm (.37") Cycle 2 0 to 0.6 P < 3 seconds 300 9.90mm (.39") Cycle 3 0.5 P to 0.8 P < 3 seconds 600 13.71mm (.54") Cycle 4 0.3 P to 1.0 P < 3 seconds 100 17.78mm (.70") Sequence Range Cycle Time Cycles Average Deflection Cycle 1 0.3 P to 1.0 P < 3 seconds 50 14.73mm (.58") Cycle 2 0.5 to 0.8 P < 3 seconds 1050 12.19mm (.48") Cycle 3 0 to 0.6 P < 3 seconds 50 7.87mm (.31") Cycle 4 0.2 P to 0.5 P < 3 seconds 3350 6.85mm (.27") Visual inspections performed on the test specimens revealed there were no penetrations through the laminate and no separation of vision-to-frame glazing at the conclusion of the cyclic pressure differentials. S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 Page 5 of 5 Detailed extrusion and assembly drawings indicating measured wall thickness and corner construction are on file and were compared to the test sample submitted. These records will be retained at CCLI for a period of four years. 6. DISCLAIMER The above results were obtained by using the designated test methods and indicate compliance with the above specification. This report does not constitute certification of this product, which may only be granted by the program administrator. CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL JEFFREY CRUMP TESTING MANAGER WESLEY WILSON LABORATORY MANAGER S-UNITED, INC. A Quality Control Company

ASTM E 1886 & 1996-05B DECEUNINCK NORTH AMERICA 142.094 SH 003 Single Hung Window REPORT #CCLI-11-160 August 18, 2011 APPENDIX A PROJECT DRAWINGS DRAWING/DETAIL SHEET DATE BOM / Layout Main Frame 10008675_SH 06/03/99 Head Frame 10008676_SH 06/07/99 Sill Frame 10008672_SH 06/18/02 Lift Rail 10008882_SH 08/04/97 Lock Rail 10008895_SH 02/08/94 Meeting Rail 10008511_SH 08/27/03 Glazing Bead 10005470_SH 06/01/93 Bulb Seal 10008206_SH 06/12/97 Sash Reinforcement 10300082 08/24/06 Meeting Rail Reinforcement 10300084 04/21/05 Sill Reinforcement 10300096 08/14/06 - END OF REPORT - S-UNITED, INC. A Quality Control Company