FIELD PERFORMANCE FOR UP FLOW FILTRATION DEVICE

Similar documents
High-Rate Stormwater Treatment with Up-Flow Filtration

WEFTEC 2006, Dallas, Texas FULL SCALE EVALUATION OF THE UPFLO TM FILTER - A CATCHBASIN INSERT FOR THE TREATMENT OF STORMWATER AT CRITICAL SOURCE AREAS

Wet Detention Ponds, MCTTs, and other Options for Critical Area Stormwater Control. Robert Pitt University of Alabama, Tuscaloosa, AL

NJCAT TECHNOLOGY VERIFICATION. Up-Flo Filter Hydro International

Errors associated with sampling and measurement of solids: Application to the evaluation of stormwater treatment devices

VERIFICATION STATEMENT

Turning Water Around. August 27, Robert Cooper Virginia Department of Environmental Quality 629 Main Street Richmond, VA 23219

Urban runoff takes many forms and has highly variable characteristics

Need to Verify Model TSS Reduction Estimates

STORMWATER MANAGEMENT

SmartDrain TM for Enhanced Biofiltration Controls

Field Verification of Performance of an Engineered Phosphorus Removal Media Deployed in a Flow Based Stormwater Filter

Construction Site Erosion Control and Phase II of the Stormwater Permit Program

CHALLENGING URBAN BMP ASSUMMPTIONS. John Moll, CEO

Monitoring. Stormwater NPDES Data Collection and Evaluation Project. Communities Included in NSQD version 3

Permeable Pavement for Stormwater Management Porous Pavement

Chapter 15 Catch Basin Inserts

SAFL Baffle Research Summary

FILTRATION FOR METALS REMOVAL FROM STORMWATER

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

TOTAL SUSPENDED SOLIDS REMOVAL TEST OF A HIGH DENSITY POLYETHYLENE WATER QUALITY UNIT. By James T. Mailloux Dean K. White

VERIFICATION STATEMENT

NJCAT TECHNOLOGY VERIFICATION. First Defense HC Stormwater Treatment Device. Hydro International

Model Results Operation and Maintenance (O& M) Results Cost-Benefit Analysis Results Conclusions

Don t Throw the Baby Out with the Bathwater Sample Collection and Processing Issues Associated with Particulate Solids in Stormwater

A. Manufactured Treatment Device Characteristics

Presented at the Water Environment Federation Technical Exposition and Conference, Orlando, FL, 1998.

2733 Kanasita Drive, Suite 111 Chattanooga, TN Phone (423) June 20, 2014

9-1. Wet-weather high-speed wastewater filtration system

BMP #: Water Quality Inserts

NJCAT TECHNOLOGY VERIFICATION

Water Quality Design Storms for Stormwater Hydrodynamic Separators

Vortex Separator. May be more cost-effective pre-treatment devices than traditional wet or dry basins.

NJCAT TECHNOLOGY VERIFICATION. Filterra Bioretention System. Americast Inc.

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

NJCAT TECHNOLOGY VERIFICATION. HydroStorm Hydrodynamic Separator. Hydroworks, LLC

STORMWATER INFILTRATION TRENCH RETROFIT UPDATE

Section [ ] Storm Water Treatment Device

Technology Review: Ultra-Urban Stormwater Treatment Technologies

Conditional Interim Certification Findings

Operation and Maintenance Manual

Wisconsin Dept. of Natural Resources. Department of Civil and Environmental Engineering. Wisconsin Dept. of Natural Resources, Madison, WI

Module 4a: The Role of Street Cleaning in Stormwater Management

Complying with the Edwards Aquifer Rules Technical Guidance on Best Management Practices

March 15, Mark B. Miller, Research Scientist AquaShield TM, Inc Kanasita Drive, Suite 111 Chattanooga, Tennessee 37343

Structural BMPs for Stormwater Treatment Control a Performance Based Design Method for Urban Drainage System

01719; PH (978) ; FAX (978) ; PH (503) ; FAX (503) ;

PROOF COPY [EE/2007/024823] QEE

Aqua-Swirl Stormwater Treatment System

INTRODUCTION BMP DATABASE PROJECTS IN PA

CHAPTER 10 PRELIMINARY TREATMENT

Hydrodynamic Separator Sediment Retention Testing

April 19, Mark B. Miller, Research Scientist AquaShield, Inc Kanasita Drive, Suite 111 Chattanooga, Tennessee 37343

Tolin Hessell 4/21/2010. Literature Review on Stormwater Management Basin Retrofits. I. Introduction

Oregon s Stormwater Technology Testing Center (STTC)

2005 Data Report University of New Hampshire Stormwater Center Dedicated to the protection of water resources through effective stormwater management

Purification of Stormwater Using Sand Filter

Performance Assessment of an Iron-Enhanced Sand Filtration Trench for Capturing Dissolved Phosphorus

Vehicle and Equipment Cleaning

Operation & Maintenance (OM) Manual v01. Bioretention Systems ENGINEERED SOLUTIONS

A Summary of the International Stormwater BMP Database

CE 370. Filtration. Overview of the Process Location in the Treatment Plant

Biofiltration and Downspout Filter Media Evaluation for BMP Decision-Making at the Port of Vancouver, WA

BIOPOD TM BIOFILTER WITH STORMMIX BIOFILTRATION MEDIA. Inspection and Maintenance Guide

Storm Drain Inlet Protection for Construction Sites (1060)

SAFL Baffle Improves Standard Sump as a Stormwater Treatment BMP

6 STOREY CONDOMINIUM 7480 DERRY ROAD WEST, MILTON

Monitoring Stormwater Best Management Practices: Why Is It Important and What To Monitor

Stormwater Sediment Sampling Project Report Project ID: SUNTREE_SED_001

SECTION DOWNSTREAM DEFENDER

Hydrodynamic Separation Product Calculator

Measuring solids concentrations in urban runoff: Methods of analysis

Gross Pollutant Traps as a Stormwater Management Practice

Use of Passive Stormwater Samplers in Water Sensitive Urban Design

Introduction. * This document was originally presented at the 9th International Conference on Urban Drainage,

9-2. Wet-weather high-speed wastewater filtration system (primary treatment of untreated wastewater)

BayFilter Design Manual

SUBSURFACE INFILTRATION SYSTEM DESCRIPTION. Alternative Names: Sump, Drywell, Infiltration Trench, Infiltration Galleries, Leach Fields

Amendments to Filtration for Improving Water Quality Treatment. Andy Erickson, Research Fellow St. Anthony Falls Laboratory September 13, 2012

This information can be obtained from good aerial photographs for existing areas, or from project. This area is entered into the main land use screen,

ENGINEERED SOLUTIONS

Stormwater Runoff Water Quality Characteristics From Highways in Lake Tahoe, California

Operation and Maintenance Manual

Mechanism of filtration : 1- Straining action: strain particles that has a big size on the sand surface.

Construction Best Management Practices Handbook BEST MANAGEMENT PRACTICES

Stabilized Construction Entrance/Exit TC-1

KriStar Perk Filter Stormwater Treatment System Performance Monitoring

Module 1: Construction Site Erosion Control

Concrete Waste Management

Leila Talebi and Robert Pitt. Department of Civil, Construction, and Environmental Engineering, The University of Alabama, P.O. Box , Tuscaloosa

Dual Media Filtration System for Reducing Pollutants in Storm Water Runoff

Sandy loam TSS removal efficiency of a stormwater BMP: Coarse perlite StormFilter cartridge at 57 L/min (15 gpm)

Using Innovative Technologies to Mitigate Phosphorus Impacts from Urban and Ag Runoff

NUTRIENT SEPARATING BAFFLE BOX: LEAF AND NUTRIENT REMOVAL SYNOPSIS

Tampa Bay Water (TBW) is a regional

What is the largest source of water pollution in the nation?

Brian Hite. Research Assistant - CUW Environmental Science - UWT Civil and Environmental Engineering - UW

AN EXPERIMENTAL STUDY OF THE OPTIMAL THICKNESS OF A SAND LAYER IN A SAND FILTER WATER QUALITY STRUCTURE. July 1994

Operation and Maintenance Manual

Structural Stormwater Pollution Reduction Targeting Floatables, Gross-Pollutants, and Trash in Myrtle Beach

Transcription:

FIELD PERFORMANCE FOR UP FLOW FILTRATION DEVICE Noboru Togawa Robert Pitt Robert Andoh Kwabena Osei Department of Civil, Construction, and Environmental Engineering University of Alabama, AL 35487, USA Hydro International, Portland, ME 04102, USA Richard Field Anthony Tafuri U.S. Environmental Protection Agency, Edison, NJ, 08837, USA

Overview o Introduction and Significance of the Research o History o Up-Flo Proto-Type Filter o Location and Size of the Filter o Full Scale Up-Flow Filter Components o Installation of Filter o Treatment Flow Rate Requirements o Controlled Flow Test o Sediment o Methodology o Result o Future Research Subject

Introduction & Significance Many types of stormwater controls are available, but most are relatively large or insufficient in their treatment capacity. Adequate treatment of runoff requires the removal of many types of pollutants as well as large amounts of debris and floatable materials, over a wide range of flows. Traditional downflow filters, which can provide high levels of treatment, can quickly clog, reducing their treatment flow rate and overall treatment capacity. They also usually operate at a low treatment flow rate requiring a large area to treat substantial portions of the runoff from a site.

History This stormwater filtration device was developed by engineers at the University of Alabama through a Small Business Innovative Research (SBIR) grant from the U.S. Environmental Protection Agency. The Up-Flow Filter was commercialized by Hydro International as part of this project. Prototype Testing Installed in a 0.9ac parking lot. Maximum filtration rate at least 25 gal/min per sq ft of filter area. Proto-Type Up-Flow Filter

Up-Flo Proto-Type Filter Illustration from Hydro International Sump can collect the heavy debris Small objects are filtered by screen and media During prototype field tests, measured: 68-94% sediment removal 70-90% reduction of typical stormwater pollutants

Full Scale Up-Flow Filter Components Illustration from Hydro International Buoyant trash is captured by flotation in the chamber and retained by the floatables baffle during high-flow bypassing Coarse solids and debris are removed by sedimentation and settle into the sump Dissolved pollutants are removed by sorption and ion-exchange in the media

Current Full-Scale UpFlow Filter Testing A 7-foot tall 4-foot diameter standard inlet containing a six module filter unit. Installed at the Riverwalk parking lot near the Bama Belle on the Black Warrior River in Tuscaloosa, Alabama. Land Use Area (ft 2 ) Area (acre) % of Land Use Parking Area 11,800 0.27 30.5 Other Paved 1,300 0.03 3.4 Sidewalks 2,100 0.05 5.4 Entrance Road 10,990 0.25 28. 5 Green Space 12,400 0.29 32.2 Total 38,610 0.89 100.0 Filter Location

Installation of the Up Flow Filter

Treatment Flow Rate Requirements The 100 gal/min filtration capacity of the full-scale filter is expected to treat about 90 percent of the annual flow for a typical rain year, with about 10 percent of the annual flow bypassing filtration. Treatment flow rate requirements for typical southeastern US conditions (Atlanta, GA), based on continuous long-term simulations (Pitt and Khambhammettu 2006)

Controlled Flow Test for the CPZ Media Water flow rate was determined by measuring the time needed to fill a measured volume. This was also used to calibrate the flow sensor. Head (in) vs. Flow Rate for CPZ Media (gal/min) Flow Rate (gal/min) 140 120 100 80 60 40 20 0 Upper Confidence in 95% Lower Confidence in 95% Actual Data Linear (Actual Data) y = 6.9449x R 2 = 0.6918 0 5 10 15 20 Head (in)

Controlled Test Sediments The test sediment in the stormwater stimulant used a mixture SIL-CO- SIL 250, SIL-CO-SIL 106 (both from U.S. Silica Co.), and coarse and fine concrete sands. The mixture was made by mixing the four components with different ratios to obtain a relatively even particle size distribution representing the complete range from about 20 to 2,000μm. Mixture Particle Distribution PSD for the CPZ Media Flow Test 100.000 80.000 % Finer (%) 60.000 40.000 20.000 0.000 10 100 1000 10000 Sieve Size (μm) Sediment mixture was manually and consistently added to the influent water over the 30 minute test period.

Features of Controlled Tests Flow rates of 24, 50, and 100 gallons/minutes were tested. Each experiment conducted over 30 minutes. River water was used as the inflow water. Effluent samples collected using a dipper grab sampler every 1 minute. During these tests, four different influent sediment concentrations were tested at each flow rate: 50 mg/l, 100 mg/l, 250 mg/l, and 500 mg/l.

Initial Controlled Test Results These tests indicated a high level of treatment even for smaller particle sizes. 0.45~3 μm Solids (mg/l) 50 40 30 20 10 0 Performance Plot for Sand Media on 0.45~3 μm Suspended Solids for 150 gallon/min Flow Rate 50mg/L 100mg/L 250mg/L 500mg/L Influent Concentration Effluent Concentartion Performance Plot for Sand Media on Total Particulate Solids for 150 gallon/min Flow Rate Total Particulate Solids (mg/l) 800 600 400 200 0 50mg/L 100mg/L 250mg/L 500mg/L Influent Concentration Effluent Concentartion

Results Summary 150 gallon/min Flow Rate and 50 mg/l Concentration Particle Size (μm) Average Influent Concentration (mg/l) Average Effluent Concentration (mg/l) Average Reduction (%) < 0.45 160 140 13 0.45 to 3 4.9 1.5 70 3 to 12 17 3.2 81 12 to 30 21 3.3 84 30 to 120 12.4 2.9 80 120 to 1180 7.7 0.12 99 > 1180 3.1 0 100 sum >0.45 μm 65.9 11.1 81

Result Summary (cont.) 150 gallon/min Flow Rate and 500 mg/l Concentration Particle Size (μm) Average Influent Concentration (mg/l) Average Effluent Concentration (mg/l) Average Reduction (%) < 0.45 170 110 37 0.45 to 3 43 5.5 87 3 to 12 160 29 82 12 to 30 200 44 79 30 to 120 123 28 79 120 to 1180 77 0 100 > 1180 32 0 100 sum >0.45 μm 635 106 82

Current Full-Scale Tests Pollutant removal will be measured during actual storm events Rain gage triggers the two auto-sampler at the same time in order to collect influent and effluent water quality

Acknowledgements Funding provided by: Hydro International, Portland, ME Graduate Student Research Program, AL Commission on Higher Education Small Business Innovative Research program, US EPA

References Describing Earlier Tests Pitt, R. and Khambhammettu, U. (2006). Field Verification Report for the Up- Flo TM Filter. Small Business Innovative Research, Phase 2 (SBIR2) Report. U.S. Environmental Protection Agency, Edison, NJ. 275 pages. March 2006. Pitt, R., R. Andoh, S.E. Clark. Laboratory and field tests of the Up-Flo TM Filter, 11 th International Conference in Urban Drainage, Edinburgh, Scotland, August 31 to Sept. 5, 2008. Khambhammettu, U., S.E. Clark, R. Pitt. Protocols for quantifying solids removal performance during controlled testing of manufactured treatment devices. Presented at the World Environmental and Water Resources Congress 2007. ASCE/EWRI, Tampa, FL, May 15 19, 2007. Pratap, M.R., U. Khambhammettu, S.E. Clark, R. Pitt. Stormwater polishing: Upflow vs. downflow filters. Presented at the World Environmental and Water Resources Congress 2007. ASCE/EWRI, Tampa, FL, May 15 19, 2007. Andoh, R., R. Pitt, and L. Glennon. Upflow filtration system for stormwater treatment. Presented at the 2007 South Pacific Stormwater Conference. New Zealand Water and Waste Association. Auckland, New Zealand May 16 18, 2006.