Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For POWER-STRUT Mounting System only

Similar documents
For Silverback Solar

moment Engineering + Design Warwick Avenue, Suite #C5 Fairfax, VA Phone: Web:

Installation Guide EcoFoot5D High Density 5-Degree Ballasted Racking System Document No. ES10560

GroundTrac. Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

Permitting and Inspecting PV Systems. PV Codes and Standards 101. Photovoltaic System Basics

On-roof system Tau Installation manual

Conergy SunTop IV Price List. Made in. USA & Ontario, CANADA

Conergy SolarFamulus II

Ballasted Roof Mounting Installation Manual

SunModo PV Rack Mounting System UL2703 Compliant

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Fig. 1 - Standard Clevis Hanger

POWER RAIL TM CATALOG PV Solar Roof and Structure Mounting System

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Solar PV System Code Compliance Best Practices, 2017 NEC Updates, and Opportunities for Improvement

About Matt Piantedosi

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

A. Product Data shall be provided for each type of product indicated.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION SUBSTATION BUS ASSEMBLIES ERGLE SUBSTATION

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

SECTION GROUNDING AND BONDING

SnapNrackTM GROUND MOUNT CODE COMPLIANT INSTALLATION MANUAL

SWH Solar Racking Installation Guide

2016 V1 SERAPHIM ECLIPSE PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO. LTD. ADDRESS: JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

US Pool Lift Model #114 (Independence) Installation Guide

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SECTION CHAIN-LINK FENCES AND GATES 02821/1

The University of Texas at Austin September 30, 2011

PATHWAYS FOR COMMUNICATIONS SYSTEMS

INSTALLATION MANUAL ANNEX OF STANDARD. For professional use only

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

Com-Tray. Under Floor

SECTION OUTLET, PULL, AND JUNCTION BOXES

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT PHOTOVOLTAIC PERMITTING GUIDELINES

PV System Permitting and Inspection. PV Codes and Standards Uniform Solar Energy Code

UNDERGROUND SERVICES SECONDARY

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. S-Dome 2.0 System.

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00. Version 1.1

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

FLORIDA PHOTOVOLTAIC BUILDINGS PROGRAM

Product Portfolio 2016 v2. Trace the sun Capture the benefit

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: LINDAPTER

Public Works Division Lighting District Supplemental Specifications For Solar School Flashing Beacon Installation March 2007

Suspension System Data Center Ceiling Solutions

TRAPEZOIDAL SHEET METAL RAIL

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

Specification Lightning Protection Systems

ST-AK 1/12. Photovoltaic Mounting Systems. Assembly Instructions. Mounting system for roofing with trapezoidal sheet metal

INSTALLATION MANUAL UL

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

rec Peak energy modules

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. SpeedRail System.

SCAFFOLDING RUNWAY SYSTEM

Product Specifications MRI Trench Duct

YINGLI SOLAR PV MODULES Installation and User Manual

Fig Beam Clamp Retaining Strap (B-Line B3367)

ROOF MOUNT KIT OWNERS MANUAL

SWH Solar Racking Installation Guide

Model # 358H-PR. 4/8/2011 Page 1 of 12

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

Electrical Metallic Tubing (EMT) Fittings

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

AN INNOVATIVE DESIGN FOR PAVING USING VERTICALLY- INTERLOCKING ARTICULATED CONCRETE MATS

Welcome to Douglas County PUD

Installation Instructions

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

YINGLI SOLAR PANDA BIFACIAL MODULES Installation and User Manual

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

Electrical Metallic Tubing (EMT) Fittings

ifix INSTALLATION MANUAL PV flat roof installation system Version

Field Inspection Guideline for PV Systems

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

A-Series Aluminum Gantry Crane

SECTION METAL FLOOR PLATE STAIRS

Model # 922-S4. 12/18/2013 Page 1 of 8

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

Model # 158-P4. 12/12/2013 Page 1 of 11

TS 805 POLES TTS CONSTRUCTION SPECIFICATION FOR POLE INSTALLATION TTS MATERIAL SPECIFICATION FOR STEEL POLES BASE MOUNTED

ETALLODOMI S.A. Head Office: 12, Kastorias str Athens GREECE. Main Warehouse: 49, Agiou Orous str. GREECE

INSTALLATION INSTRUCTIONS

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Model # 338S-OP. 9/30/2011 Page 1 of 13

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

RS32 Multi-Section Skylight System under/over seam clip double diverter

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

TEMPORARY METER POLE INSTALLATION

Transcription:

Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For POWER-STRUT Mounting System only Please read carefully before installing. Burndy LLC recommends that the sufficient details of the installation be submitted to the AHJ for approval before any work is started. WEEB-WMC WEEB-Lug 6.7 Products are tested to UL 467, CAN/CSA-C22.2 No. 41 US/Canadian standards for safety grounding and bonding equipment Page 1 of 12 3098177

Standard Top Down Clamps WEEB COMPATIBILITY The WEEB family of products can be used to bond anodized aluminum, galvanized steel, steel and other electrically conductive metal structures. All installations shall be in accordance with NEC requirements in the USA and with CSA C22.1 in Canada. The WEEBs are for use with modules that have a maimum series fuse rating of less than 25A. The WEEBs used for bonding the PV modules to the mounting rails are compatible with various cross-sections of module frames. The following are eamples of module frames that are compatible. Notice that the WEEB teeth are positioned completely under the edge of the module frame. OK OK OK The following is an eample of a module frame that is incompatible with the WEEB. The WEEB teeth are positioned only partially under the edge of the module due to the lip on the top edge of the module frame. X Page 2 of 12

WEEB COMPATIBILITY Module frames like those shown here may have a ridge or lip on the bottom edge of the frame that would prevent the WEEB teeth from fully embedding. X Shown here is an eample of a groove that will prevent the WEEB teeth from properly penetrating the module frame. This type of frame is not compatible with the WEEB. X Important Note: Shown here is an eample of a lip that will prevent the WEEB teeth from properly penetrating the module frame. This type of frame is not compatible with the WEEB. Inspect each module frame used with a WEEB to ensure that the bottom mounting face of the frame is flat, and that there are no hinderances to embedding WEEB teeth. Do not use a module with a frame that prevents the WEEB teeth from embedding fully. Page 3 of 12

WEEB-WMC on Boed Module Frames Certain module frames do not have enough structural strength to withstand the force required to embed a WEEB. These frames will deform and therefore not allow sufficient penetration of the WEEB teeth. The general requirements for minimum module frame thickness of "boed" type module frames are illustrated below. OK NO LESS THAN 3mm NO GREATER THAN 8.5mm NO THINNER THAN 1.5mm Page 4 of 12

SYSTEM OVERVIEW Use WEEB-WMC to bond solar modules to module mounting rail. Use WEEB Bonding Jumper to electrically connect mechanically spliced rails. Important notes 1. 2. 3. Use one WEEBLug-6.7 assembly per rail to connect system to equipment ground conductor. Use general purpose anti-seize compound on fastener threads when installing WEEBs. The NEC section 690.43 states, "Eposed non-current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accordance with 250.134 or 250.136(A) regardless of voltage." WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. Page 5 of 12

1 WEEB-WMC ASSEMBLY Power-strut midclamp 5/16" He bolt WEEB-WMC Power-strut channel nut Pre-assemble WEEB-WMC to mid-clamp assembly as shown. Pre-assembling WEEB-WMC to mid-clamp assembly will contain the small individual parts, reducing the possibility of losing parts during installation. 2 Assemble end clamp to manufacturer's specification. Page 6 of 12

3 MIDCLAMP ASSEMBLY Slide pre-assembled WEEB-WMC and mid-clamp assembly into position. Slightly lift solar module and slide WEEB-WMC and midclamp assembly into position. WEEB teeth will automatically be aligned under the edge of the module when the mid-clamp assembly is correctly installed. Important note: To correctly install WEEB-WMC, ensure that both sides of the solar modules are completely positioned against the mid-clamp. Refer to WEEB compatibility page for illustrations. Visually check that WEEBs are properly positioned. Page 7 of 12

Important note: WEEBs are for SINGLE USE ONLY! Do not torque fasteners down if position of solar modules is not finalized. Only slightly tighten fasteners to keep modules in place. 4 When position of solar modules are finalized, torque fasteners to 12ft-lb / 16.3 N-m using general purpose anti-seize compound on threads. 5 Assemble end clamp to manufacturer's specification. Page 8 of 12

6 WEEB-WMC LAYOUT EVEN NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-WMC C X R = 4 X 1 WEEB-WMC NEEDED = C X R = 4 X 1 = 4 ODD NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-WMC C X R = 5 X 1 WEEB-WMC NEEDED = [C+1] X R = [5+1] X 1 = 6 Note: When replacing a single faulty module, also remove the adjacent module which contacts the same WEEBs as the faulty module. This will ensure that there are never ungrounded modules in the array. Page 9 of 12

7 WEEBLUG ASSEMBLY Drill bolt clearance hole 17/64 in / 7mm in vertical rail support. For best aesthetics, drill hole on least visible side of rail. WEEB teeth towards rail. Assemble WEEBLug-6.7 assembly and torque fasteners to 10ft-lb / 13.5 N-m using general purpose anti-seize compound on threads. Important note: 1. WEEB-6.7 that sits under the WEEBLug is for SINGLE USE ONLY! Ensure position is correct before tightening. 2. The WEEBLug-6.7 may be used with a maimum equipment ground wire of 6 AWG. Page 10 of 12

GROUND CONDUCTOR ASSEMBLY 8 Equipment ground conductor Lay in equipment ground conductor and torque bolt to 7ft-lb / 10 N-m. Page 11 of 12

SPLICE KIT ASSEMBLY 9 The WEEB Bonding Jumper 6.7 must be used in order to properly electrically bond spliced rails. WEEB Bonding Jumper 6.7 Torque fasteners to 10ft-lb / 13.5N-m using general purpose anti-seize compound on threads. Page 12 of 12