Section 7 Waterproofing Roofing Standards

Similar documents
HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

Pattern-Design Modified Bitumen Cap Sheets

Centennial School District Section Material Specifications MATERIAL SPECIFICATIONS:

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Product Technical Bulletin SPM-4H-250

APPLICATION SAFETY TOOLS REQUIRED

Rubberized Asphalt Mastic and Coating

ROOF REPLACEMENT SPECIFICATIONS

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

Product Technical Bulletin APS-5T

SUBMITTALS Descriptive literature: Submit manufacturer's application instructions and technical data sheets or catalog cuts on materials.

SPECIFICATION SUBMITTAL

Modified Bitumen Roofing Systems Simplified Approach to Commercial Low Slope Roofing

TOPCOAT Product Catalog

Thermoplastic Single Ply & Multi-Ply Roofing Systems

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

ACFoam-II HCFC Free "Green" Polyiso Specification

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

PRODUCT CONTROL SECTION

2010 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

WATERPROOFING TAMKOWATERPROOFING.COM

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Non-Residential Cool Roof Cost Summary

TOPCOAT Restoration Specifications Structural Concrete

SECTION PVC SINGLE PLY ROOFING

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

Commercial Roof Systems

J41 Reinforced bitumen membrane roof coverings

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Sure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents

SECTION 07530CP EPDM MEMBRANE ROOFING

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

B.U.R., Modified & Shingle. Roofing Systems. Section 3 - Low Slope Roofing Installation Instructions

SECTION SELF-ADHERING SHEET WATERPROOFING

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

1.1 SECTION INCLUDES Verify Scope, including identification of plies and type of coating.

1 Exam Prep. Roofing Practice Exam 9

COMMERCIAL ROOFING SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION SBS MODIFIED BITUMEN SHEET ROOFING

SHEET METAL ROOF TEST REPORT

MAKE ROOFS LAST LONGER

CS-100 Guide Specifications

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

Application Specification:

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

ASSEMBLY DESIGN CRITERIA

A. Source Limitations: Obtain each type of building insulation through one source.

TOPCOAT System Specifications Corrugated Transite Panels

SECTION ROOF SPECIALTIES

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

GUIDE SPECIFICATION Cold Adhesive Application

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

The Cool Roofing Solution

Design & Construction Standards, Revised January

UL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat

Specification & Detail Guide

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

Sarnafil Adhered Single-Ply Roofing Systems

Thornbury Sewer Treatment Plant Roof Report 2016

1 Firestone EPDM Roofing Systems

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

(Project Location) (your firm's name)

.1 Provide submittals in accordance with Section Submittal Procedures.

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

1. Project Location: Phase II Roof Troughs and Aluminum Gutters at the Morial Convention Center.

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

GE SCM3500 High Solids Silicone Roof Coating

SECTION SBS-MODIFIED BITUMEN MEMBRANE ROOFING HEAT-WELDED

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Hot Mopped / Cold Applied Adhered (VersiFleece AC TPO) Mechanically Attached Roofing System (VersiFleece AC TPO/VersiFleece AC EPDM)

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

Department of Environmental Protection August 22, 2014 Attn: Katie Parrish 3900 Commonwealth Blvd MS520 Tallahassee, FL 32399

TAM-PRO CEMENTS & COATINGS

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

MID-STATES ASPHALT

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

A. Submit product data sheets and literature verifying physical properties of materials.

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SPECIFICATION AND DETAIL GUIDE

Pressure-Sensitive Adhesives in Roofing

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

Firestone Polyiso Boards

Master Guide Specification Page 1

FOAMULAR Insulation, PRMA, Horizontal Waterproofing

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

RESIDENTIAL ROOFING PRODUCT GUIDE

Transcription:

Section 7 Waterproofing Roofing Standards

Section 7 Waterproofing Roofing Standards... 1 Purpose... 3 Roofing Assemblies... 3 ASTM Standards... 4 Design considerations... 7

Purpose The purpose of this document is to establish the roofing standards for the University of Texas at El Paso. The University of Texas at El Paso has established these standards to decrease life cycle costing, reduce maintenance and ensure the bidding contractors submit competitive bids for apples-to-apples bidding. Roofing Assemblies The following is a good, better, best scenario of favored roofing assemblies by the University. Please use the performance requirements as established by ASTM to meet the University s needs. Good Field - Four (4) Type VI Fiberglass Felts and Fibered Aluminum Coating Flashing System - Underlayment and Flashing Membrane Warranty 20 NDL Year Warranty The Standard BUR is not a recommended roofing assembly with a high R-Value. The increase in insulation requires an increase in performance of membrane. The increase in R-Value prevents heat from entering the building. As a result, the heat is isolated at the top of the roofing assembly. The low performing standard BUR membrane will under perform in the hot El Paso sun. Please see article, Thermal Shock in Built Roofing Recommendation: Decrease the R-Value. Or specify a Type III modified membrane. Better Field Two (2) Type IV Fiberglass Felts and Modified Membrane Flashing System Underlayment and Flashing Membrane Warranty 25 Year NDL Warranty Recommendation: Great the way it is designed. Best Field One (1) Base Sheet, Two (2) Type IV Fiberglass Felts, Modified Membrane, Flood Coat and Gravel Flashing System Underlayment and Flashing Membrane Warranty 30 Year Partnership Warranty Recommendation: The Base Sheet is not needed.

ASTM Standards The following standards are the minimum standard requirements for the roofing assemblies and coverage rates. Description ASTM Performance Standards Minimum Coverages Insulation Minimum R-Value 19.0 (Polyisocyanurate is preferred FM 1-90, 3.0 Sq. Ft. over Extruded Polystrene) Type and Thickness R-Value 3 Polyiscocyanurate 18.00 ½ Wood Fiber 1.39 BUR Membrane 0.24 1 fastener per 3 sq. ft. works out to 11 screws per 4 x 8 insulation board. Base Sheets Glass Felts Type IV Glass Felts Type VI Fibered Aluminum Coating Flashing Under Layment Modified Membrane and Flashing Membrane 3.0 polyisocyanurate fastened to deck with 0.5 perlite in hot asphalt. ASTM D4601, Type II asphalt coated fiberglass base sheet. ASTM D2178, Type IV glass fiber roofing felt bonded to the prepared substrate with hot Type IV bitumen. ASTM D2178, Type VI glass fiber roofing felt bonded to prepared substrate with hot bitumen. Fibered aluminum roof coating having the following characteristics: Flash Point 100 F (38 C) min. Weight/Gallon 8.2 lbs./gal. (1.0 g/cm3) Viscosity (75 F) 100-125 K.U. Thickness 60 mil minimum SBS modified membrane with woven fiberglass scrim reinforcement with the following minimum performance requirements according to ASTM D5147: Properties (Finished Membrane): Tensile Strength (ASTM D5147) 2 in/min. @73.4 ± 3.6 F MD 215 lbf/in Tear Strength (ASTM D5147) 2 in/min. @ 73.4 ± 3.6 F MD 275 lbf Elongation at Maximum Tensile (ASTM D5147) 2 in/min. @ 73.4 ± 3.6 F MD 4.5% ASTM D-6162, Type III, Grade G Minimum 135 mil thick SBS and SIS (Styrene-Butadiene-Styrene and Styrene- Isoprene-Styrene) mineral surfaced rubber modified roofing membrane with fire retardant characteristics and reinforced with a dual fiberglass scrim and polyester mat. 2 Gallons / Square

Flood Coat and Gravel Tensile Strength (ASTM D5147) 2 in/min. @ 73.4 ± 3.6 F MD 450 lbf/in Tear Strength (ASTM D5147) 2 in/min. @ 73.4 ± 3.6 F MD 900 lbf Elongation at Maximum Tensile (ASTM D5147) 2 in/min. @ 73.4 ± 3.6 F MD 6.0% Low Temperature Flexibility (ASTM D5147): Passes -30 F (-34 C) Modified Asphalt: Hot applied, SEBS (Styrene-Ethylene-Butadiene-Styrene) modified asphalt having the following characteristics: Penetration Point (ASTM D-36) 203-221 F Elongation (ASTM D-412) 1100% Recovery from 300% Elong. 50% Solubility (ASTM D-2042) 99% min 1. Roofing Aggregate: To conform to ASTM D-1863 a. Slag, Pea Gravel, or White Spar 60 lb per 100 ft² ± 25% Interply ASTM D312, Type IV special steep asphalt having the following characteristics: a. Softening Point 210 F - 225 F (99 C - 107 C) b. Flash Point 500 F (260 C) c. Penetration @ 77 F 15-25 units d. Ductility @ 77 F 1.5 cm 25 lb per 100 ft² ± 25% All roofing assemblies should meet a UL Class A fire rating. The reflectivity of the membrane should have a reflectivity of 60% or higher as rated by the Cool Roof Rating Council. To learn more, please visit http://www.coolroofs.org. All submittals will include: a. Product data, description of product(s) b. Sample(s) included/attached c. Roofing System Manufacturer s Certification Form, listing the following Underwriters Laboratories, or approved third party testing facility in accordance with ASTM E108, Class A for external fire and meets local or nationally recognized building codes. Certify that materials are manufactured in the United States and conform to requirements specified herein, are chemically and physically compatible with each other, and are suitable for inclusion within the total roof system specified herein. Written certification from the roofing system manufacturer certifying the applicator is currently authorized for the installation of the specified roof system.

Certify that the manufacturer is the parent company specializing in manufacturing the products specified in this section with minimum 10 years documented experience and has an ISO 9001 certification. d. FM 1-90 Certification e. UL Class A Certification f. ISO Certification Certificate g. Independent Test Data according to ASTM D5147 h. Unexecuted copy of specified Manufacturer's Required Warranty i. Written letter from a Company Executive stating that a manufacturer s representative will be on site a minimum of three (3) times a week from inception to completion of the project, monitoring the jobs ensuring proper installation and providing weekly status reports to the Owner. Also, provide annual inspections at the owner s request.

Design considerations When designing a roofing assembly, use the following design standards. It is the University best interest to obtain a low maintenance roofing assembly. Crickets behind every HVAC and Heavy Equipment unit that is greater than two feet. Use faced pitch pans around every penetration (i.e., Including gas lines, conduits, equipment stands and condenser unit pipes). Use reglet flashing system Interior walls should be covered with modified membrane and/or metal wall panels. Flashing laps should be sealed with a strip of torch grade membrane that extends 6 beyond center of the lap. Slope to have a minimum ½ :12. Preferably structured slope. Flashing height minimum 8 (including perimeter and base flashing).