Product catalogue A25s. Solar Cooling systems

Similar documents
Renewable technology. For low carbon space and water heating VOKERA RENEWABLE TECHNOLOGY PRODUCTS

SorTech package solution description

HIGH PERFORMANCE SOLAR THERMAL SOLUTIONS

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

EVASOLK. Evaluation of Solar Cooling in Comparison to Reference Technologies

Modeling and analyzing solar cooling systems in Polysun

VRF 50/60Hz V5 E Series

NEW! PLUS. Free. Hot. Water. Solcrafte COATING. The first compact hot water solar system

MV Product Specifications

Air-cooled Chillers with High Speed Centrifugal Compressors

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

Air Cooled Packaged Air Conditioning

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Energy Savers: Air-Source Heat Pumps

Investigation of a Solar active glass facade

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Solar Flat Plate Thermal Collector

Caribbean Hotel Energy Efficiency Action (CHENACT)

Refreshment Experts. FS Series. Combination. vending machine FS 2020 EC

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

Unit Coolers SKB. 4 kw 30,5 kw.

Hot water persons. Map section

Solar Thermal. Reducing Gas/Oil Separation Plant Running Costs & CO 2 Footprint with TVP High Efficiency Mirrorless Solar Thermal Panels.

northern ireland Renewable heat

Water-Cooled Screw Chillers and Water/Water Heat Pumps

Organic Rankine Cycle Technology

Absorption Chillers in Commerce

Condenser Water Heat Recovery"

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

VENTILATION AIR CONDITIONING AIR CLEANING HEATING

Solar Energy Technologies

DUBAL Energy Optimization Absorption Chiller Pilot Project

SWIMMING POOL HEATING CLIMEXEL LISTEN TO THE SILENCE... APPRECIATE THE PERFORMANCE... S ERIES HEAT/COOL PUMPS. P ool & Spa Equipment

!"#$%&"#'"$( (% +, -

MEASUREMENTS AND BENCHMARK OF PV-T COLLECTORS ACCORDING TO EN12975 AND DEVELOPMENT OF A STANDARDIZED MEASUREMENT PROCEDURE

GLAUNACH THE SILENCER HANDBOOK INSULATION SUPPLEMENTARY ACOUSTIC SHIELDING OF SILENCERS, PIPES & CO GLAUNACH GMBH ALL RIGHTS RESERVED -

ASHRAE s s Sustainable Roadmap. .meet the ASHRAE GreenGuide. Research Strategic Plan. Journal Articles

Microturbine Energy Solutions in the CHP Industry

Reliable Clean Initiatives

Experimental investigation of photovoltaic-thermal hybrid solar collector

Domes Pyramids Opening Rooflights Flatglass Rooflights

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.

Run On Sun Australia Ph

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

APPLICATION OF CUSTOMIZED ABSORPTION HEAT PUMPS WITH HEATING CAPACITIES ABOVE 500 kw PROJECT: ACKERMANNBOGEN, MUNICH

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

A New Absorption Machine for Both Cooling and Heating

YANMAR s 35 kw Combined Heat and Power System.

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, plc, All Rights Reserved

Solar Thermal. [Strategy]

Chromasun Micro-Concentrator

ACTIVE SOLAR SYSTEMS

24th World Gas Conference ARGENTINA WOC 5.1: Industrial Utilisation CHP - Sharing on Gas District Cooling (GDC) in Malaysia

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

Inventaire des installations de climatisation solaires en Europe Inventory of solar cooling installations in Europe

Sustainable Maintenance Best Practice: Energy Efficiency in the Carbon Free World. Michel Abi Saab. Team Leader, Energy Efficiency LEED AP, CEM, CMVP

Acoustic housing for whisper quiet heat pumps

Energy Efficiency. best in class

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor

ABSTRACT: VENTILATION The European Commission, Energy Performance of Buildings Directive, and its Ventilation Implications. Eric Curd.

Project summary. 2 MW project Schalkwijk Haarlem Netherlands

Optimizing the Features of a Customizable Air-Cooled Chiller

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Sullair Water Chillers. Precision Chilled Water

Solar Thermal Application in Industry

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

State of the art of new generation commercially available products

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

ZERO GREENHOUSE GAS EMISSIONS

All panels can be supplied in a range of styles, to suit the applications pictured below.

Sandwich Panel Production Line. Allbest Creative Development Ltd. (ALLBEST)

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Hotels: Water and Energy

Packaged AHR (Advanced Heat Recovery) Systems for Engines, Gas Turbines, & Industrial Waste Heat. Tom Pierson

Renewable Energy Based Active Cooling System

Regenerative heat exchanger with ceramic core; high thermal efficiency (up to 90%). Telescopic pipe adaptable to the wall thickness.

1/58 Components of solar systems

Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

Zoned Comfort Control

l i* \40 NOM 5,5 to 22 kw Compressed air at your service LR:I itc-1-1 L-Ms AIR COMPRESSORS 41k ir MANUEL GUEDES MARTINS, UNIPESSOAL, Mi...

COMFORT AIR QUALITY ENERGY OPTIMISATION

Alternative Sources of Energy

The Sun from SOLution Solartechnik GmbH Solar domestic hot water, heating, cooling and electricity DERBI International Conference 11th-13th of June

THE XZIEX INDUSTRIAL / COMMERCIAL ATMOSPHERIC WATER GENERATOR

Absorption Chillers in Industry

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

Making a difference to your environment. Suncool conference LIFE11 ENV/SE/ SUNCOOL

B. System Design and Performance Requirements

STERLING. Construction & Development Corporation MODULAR BUILD. Cost Competitive System

Experiences from design studies, simulation studies and installations

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

ClimaGuard Neutral 70

Reminder: Solar and Terrestrial Radiation

SOLAR COOLING FOR ENERGY SAVING. CAN WE AFFORD NOT TO USE THE HEAT OF THE SUN?

Transcription:

Product catalogue A25s Solar Cooling systems

COOLING POWERED BY NATURE FLEXIBLE DESIGN The Purix Solar Cooling system helps you building a green tomorrow without compromising the basic needs for a comfortable and healthy indoor environment - where and when you need it. The patented system design is ideal for replacing traditional split cooling and air conditioners in a wide range of applications, e.g. retail, offices, households, clinics, hospitals, sports facilities, institutions, hotels, restaurants and bars, schools, storages or data & telecom installations. Powered by solar heating and designed for water as natural refrigerant, PURIX systems provides cooling and air conditioning from natural resources. Applying conventional absorption cooling technology for replacing expensive electricity with solar heating, a PURIX solar cooling system is a great opportunity for reducing costs,environmental impact and greenhouse gas emissions. A flexible product design recognizes the need for integration with the interior design and architecture, and supports various types of indoor units. Depending on the building layout and cooling demand, the systems support mono- and multi split installations, and may be configured into systems with increased capacity. PRODUCT FEATURES Low electricity consumption reduces energy costs. Applies pure water as natural refrigerant. Cooling based on low temperature thermal energy sources instead of electricity (solar thermal energy, district heating, waste heat etc.) Flexible design for match with interior design and architecture - various fan coil types, - mono & multi split design. Low noise level. Gently heats and cools without drying out the indoor environment.

2 1 OUTDOOR INDOOR 3 Backup thermal energy source (optional). A PURIX Solar cooling system consists of three main parts: 1 - Solar thermal collector 2 - Outdoor unit (Chiller) 3 - Indoor unit (Fan coil)

SPECIFICATION PURIX Chiller A25s Type Chiller for mono- & multi split installation (up to 3 indoor units) Technology Refrigerant Chilled Water 1-stage absorption chiller (LiBr-H2O), air cooled Fluid Capacity Temperature Pressure, max. Connections R718 (water) [kw] [ C] [BarG] Chilled water (freeze protected) 2,5 (nominal at 35 C outdoor temperature) 13 / 18 (supply/return) 0,5 G1/2 Backup heat supply Power Temperature Pressure, max. Connections [kw] [ C] [BarG] Electricity demand [W] [db(a)] Noise level <150 <45 energy source, supply temperature requirements Minimum temperature [ C] *Thermal 3,1 (at 35 C outdoor temperature, T = 5 C) Varies with outdoor temperature* 3 G1/2 Outdoor temperature [ C]

SPECIFICATION * Fan coils Cooling capacity High Wall Cassette Floor/ceiling 2,5 2,5 2,5 <50 <110 <80 [kw] Electricity consumption [W] Air flow [m³/h] 500/410/360 600/560/530 1000/750/500 Noise level [db(a)] <48 <47 <47 Dimensions (LxWxH) [cm] 94x20x30 84x84x19 130x19x60 Weight [kg] 13 27 34 1/2" / 12,7 3/4" / 19,05 3/4" / 19,05 15,6 33 33 Connections - Chilled water [Inch/mm] - Drain [mm] User interface, std./optional Remote / wired controller PRODUCT FEATURES Silent mode Multi speed fan Auto cleaning Washable filter Condensate pump *Other fan coil types an and capacities are available upon request. High Wall mounted Cassette Floor/Ceiling

SPECIFICATION Solar Collectors Type Gross aea Absorber area Aperture area LxWxH Weight Material, frame Absorber Absorption Emission Glass, thickness Transmission Insulation Stagnation temperature Certificates Warranty Flat plate collector [m²] 2,51 [m²] 2,3 [m²] 2,39 [mm] 2150 x 1170 x 83 [kg] 42 Aluminium Meander, Al high selectiv vacuum coating [%] 95 [%] 5 [mm] 3,2 (tempered) [%] 90 [mm] 40 (mineral wool) [ C] max. 234 EN12975-1 / EN12975-2 / CEN Keymark [years] 5 Collector mounting kits Flat roof/ground On-roof In-roof

DIMENSIONS 2420mm 1720mm 1750mm 35 CONNECTIONS Optional Backup heat, supply Chilled water, supply Backup heat, return Chilled water, return Electricity, 230VAC, 50Hz Working solution, supply Working solution, return

About PURIX We believe that people should experience a comfortable and healthy indoor environment, without compromising sustainability. PURIX provides attractive solutions supporting consumers and organisations in building a Green tomorrow. Langogade 17 2100 Copenhagen O DENMARK t: +45 7734 2280 e: info@purix.com w: www.purix.com PURIX Catalogue A25s EN ver01c PURIX ApS