A Case Study of ARCH 685 for ARCH 631 given by Keith Wilson - Summer 2003

Similar documents
Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

North Mountain IMS Medical Office Building

Structural Redesign Gravity System

January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options

William W. Wilkins Professional Building

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

Types of Foundations

Salt lake city Public Safety Building. Case Study CS 2. Grounded in strength.

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

111 MORGAN ST. Ryan Friis

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

Earthquake Design of Flexible Soil Retaining Structures

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

Foundation/Site Work Code Requirements

THE FORENSIC MEDICAL CENTER

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

UNDERPINNING A CRANE FOUNDATION

October 3, Section 1.2 Scope and Section 6.6 were revised to clarify interior and exterior construction types allowed.

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

Hilton Baltimore Convention Center Hotel Western Podium

S T R U C T U R. Technology. magazine. Software for the Structural Design of Masonry. The Design Basis. Copyright

Structural Design Challenges for Plaza 66 Tower 2

THE FORENSIC MEDICAL CENTER

Franklin Square Hospital Center Patient Tower

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

Suspended Metal lath and Cement Plaster. Coverings Rigid Insulation, 1/2 - in 0.75 psf. Floor Fill Lightweight Concrete, per inch 8 psf

Loads and Load Paths. "Architecture is inhabited sculpture." -Constantin Brancusi

Design of Semi gravity Retaining Walls

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

North Mountain IMS Medical Office Building

Global Village Rochester Institute of Technology Rochester, New York

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980)

Low Maintenance Slabs Supports Are Needed for Long-Term Performance of Welded Wire Reinforcement In Slabs-On-Grade

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

Structural Renovation of Fallingwater. Spring 2004 Arch 631 By: Kayvan Madani Nejad Instructor: Dr. Anne Nichols

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

SOILS AND FOUNDATIONS

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

SOILS AND FOUNDATIONS

Concrete Block Machines Typical Fixed Block Machine

The. Guthrie. Theater. Tina Chanady Scott Kapczynski Winnie Lam David Pearce. Photo: Yoshio F.

Structural Technical Report #2 By Robert Whitaker

Technical Assignment 1 10/8/03

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Structural Requirements

[Neherkar, 7(1): January-March 2017] ISSN Impact Factor

2 1. In cracked external corners place wooden planks across the crack and then support the planks with wooden members.

Performance of Buildings During the January 26, 2001 Bhuj Earthquake. Abstract

Learning Objectives. A Brief History

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Structural Option April 7 th, 2010

CONSTRUCTION PROCEDURES. AWWA D110 Type I Prestressed Concrete Tanks

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

The NWX Prairie Style

RETAINING WALL LEVEL BACKFILL

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari January 13 th, 2012

SITE WORK II: Footings, Cisterns

MEMORIAL SLOAN-KETTERING CANCER CENTER

APPENDIX "B" November 5, 2002 Page 1 of 6 BOILERSMITH LTD. STACKS AND BREECHING

SOILS AND FOUNDATIONS

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

Asia & Australasia: A Selection of Written Works on the World's Tall Building Forefront

Totaling approximately 617,000

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

LPI 56 Technical Guide

Tech Tips SidePlate Connections FAQ 09/30/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

Structural Technical Report 1 Structural Concepts / Existing Conditions

1 of :06

(b) Discuss in brief shaft spillway with neat sketches. Marks 04. OR Q (2) Explain in brief USBR stilling basin. Marks 08

Highway Drainage 1- Storm Frequency and Runoff 1.1- Runoff Determination

The designer shall also submit additional information required by the University as described and underlined below.

Executive Summary Thesis Proposal

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

City of Richmond Zoning Ordinance Page 12-1

one structural behavior, systems and design Course Description Course Description Syllabus & Student Understandings statics mechanics of materials

Proposed Modification to the Florida Building Code

Sri Rama Krishna Institute of Technology Basic civil engineering Unit-2(BUILDING COMPONENTS AND STRUCTURES) 2 mark questions

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

UNIT III Earthwork Estimation & Reinforcement Estimation

1 Exam Prep Concrete Masonry Handbook Questions and Answers

Pro-Con Structural Study for Alternative Floor Systems October 27, 2004

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Structural Inspection

Technical Notes 39A - Testing for Engineered Brick Masonry - Determination of Allowable Design Stresses [July/Aug. 1981] (Reissued December 1987)

Hilton Baltimore Convention Center Hotel Western Podium

BUILDING INTEGRITY SUMMARY REPORT

Transcription:

A Case Study of ARCH 685 for ARCH 631 given by Keith Wilson - Summer 2003

Reasons for the Imperial Hotel as a Case Study : Survived the great Kanto earthquake of 1923 while many other buildings perished. A rare example of a designer s thorough attempt to integrate architecture and engineering into a comprehensive seismic design strategy. Created the beginnings of many features for seismic design in buildings which are state-of-the-art today. The building was also a forerunner in the development of radiant heating, forced air ventilation, and indirect lighting. A famed and landmark status building

The Designer of the Imperial Hotel : The Imperial Hotel was designed by great American architect Frank Lloyd Wright. The hotel was first commissioned by FLW in 1915 and construction was finished in 1922. One of the main driving forces of the design was how the building was to withstand the dreaded temblor as well as the fire that ensues. Frank Lloyd Wright The terror of the temblor never left me while I planned the building nor while, for more than four years, I worked upon it. - FLW

The Design of the Foundation : The general method of resisting earthquakes in foundation design during the time the Imperial was built was thought to be along the lines of a rigid structure; generally, the more rigid the better. 8 ft of soft soil 75 ft alluvium General foundation design before the Imperial

The Design of the Foundation : The general method of resisting earthquakes in foundation design during the time the Imperial was built was thought to be along the lines of a rigid structure; generally, the more rigid the better. The soil of the site consisted of a top layer of soft soil at a depth of about 8 feet. Below that was softer alluvium soil and ground water to a depth of about 75 feet. Because of this, the method of using long piles was a common foundation design. 8 ft of soft soil The long piles were used to transfer the load of the building down directly to the solid earth. The problem with long piles during an earthquake is that they create a plastic hinge (a point where the pile can no longer take the bending moment and so begins to yield.) 75 ft alluvium General foundation design before the Imperial (Red shows the failure)

The Design of the Foundation : FLW and Julius Hoto (the Structural Engineer) both believed that because of the wave movements through the earth and based on the soil type, deep foundations like long piles would oscillate and rock the structure. Therefore the foundation should be short and shallow. The main theory was that the deep level of mud that underlies the surface soil would act like a good cushion to relieve terrible shocks. It was believed that the building should float upon it as a battleship floats on salt water. The solution that they came up with for transferring the load is quite novel: Nine inch diameter tapering concrete piles Only eight feet in length Set about every two feet along the length of the walls in pairs or threes side by side Cu = 100psf Assume?c = 145 pcf Assume?s= 100 pcf L = 8-0 pile d = 0-9 e = 1-0 Based on Chart for Ultimate Lateral Resistance Hu / Cu d² : Hult / Cu d² 23 when e = 1-0 Working Load Value for H = 12,938 / 2 = 6,469 lbs fc = equating horizontal forces fc = Hult / 9Cu d² = 12,938/9(1,000)(.75)= 1.92 ft Mult = Maximum Resisting Moment = Mult = Hult[e+1.5d+fc/2] = The piles were friction piles. The building was computed pound for pound and distributed equally so that it was uniformly loaded. Here is a typical calculation for the lateral load for one pile: Typical tapering concrete pile (12,938)[1+1.125+.96]= 39,914 Ft-lb Working Load Value for M = 39,914/2 = 19,957 Ft-lbs

Flexure : Why fight with the quake? Why not sympathize with it and outwit it? FLW Schematic layout of joints from floor plan Main Floor Plan of the Imperial To make the flexible structure instead of the foolish rigid one, FLW divide the building into parts. The parts that were necessarily more than 60 feet long were jointed clear through the floors, walls, lootings and all. Where ever part met part were through joints as well. Through careful calculation of a uniform load, the building became able to ride the waves of the temblor. Close up of Schematic Piles

The Waiter s Tray : A good construction was needed where floors would not be carried between walls, because subterranean disturbances might move the walls and drop the floors. Why not carry the floors as waiter carries his tray on upraised arm and fingers at the center- balancing the load. This meant the cantilever, as I had found by now. - FLW Cross Section of the Imperial Schematic of wall with floors connected at edges into wall What Wright was saying was instead of supporting the floors at their edges, which was common practice, support the floors from their center. Connections Disturbances may move the walls and drop the floors

The Waiter s Tray : A good construction was needed where floors would not be carried between walls, because subterranean disturbances might move the walls and drop the floors. Why not carry the floors as waiter carries his tray on upraised arm and fingers at the center- balancing the load. This meant the cantilever, as I had found by now. - FLW ads going to center support system Schematic of Cantilever Slab Cross Section of the Imperial And so concrete cantilever slabs continuous across the building from side to side became the structure for the Imperial Hotel at Tokyo. All of the slabs were in conformance with the Chicago code, but FLW disregarded it since early code provisions of reinforced concrete were sometimes unduly conservative. FLW called for much lighter sections to be used and the structural engineer notes that was entirely logical. Columns and connections supporting the floor slabs Close up of Waiter s Tray Slab

Exterior Wall Construction : Poured Concrete binding two Shells together The exterior wall structure was load-bearing masonry. The outer walls were spread wide, thick and heavy at the base growing thinner and lighter toward the top. In doing so, the center of gravity was kept low against the swinging movements, and the slopes made an aesthetic feature of the design. In addition to keeping a low center of gravity, the roof was topped with light hand-worked green copper instead of the heavy roof tiles that were typically used. Exterior Shell lim cunning brick tyle and size never made before) Typical Exterior Wall Construction Interior Shell Fluted hollow brick (the first in the Empire) thinner The whole structure was set up as a double shell - two shells, an exterior of slim cunning bricks and an interior of fluted hollow brick. These shells were poured solid with concrete to bind them together. THICKER Cross section showing exterior walls growing thinner toward top

Exterior Wall Construction : Poured Concrete binding two Shells together The exterior wall structure was load-bearing masonry. The outer walls were spread wide, thick and heavy at the base growing thinner and lighter toward the top. In doing so, the center of gravity was kept low against the swinging movements, and the slopes made an aesthetic feature of the design. In addition to keeping a low center of gravity, the roof was topped with light hand-worked green copper instead of the heavy roof tiles that were typically used. Exterior Shell lim cunning brick tyle and size never made before) Typical Exterior Wall Construction Interior Shell Fluted hollow brick (the first in the Empire) The whole structure was set up as a double shell - two shells, an exterior of slim cunning bricks and an interior of fluted hollow brick. These shells were poured solid with concrete to bind them together. Detail of exterior wall and brick

Piping, Wiring, and Water : Mains and all pipes were of lead with wiped joints. The pipe bends sweeping from the trenches to be hung free in vertical pipes shafts, from which the curved pipe branches were again taken off, curved, to the stacks of bathrooms. Thus, any disturbance might flex and rattle but not break the pipes or wiring. An immense pool as an architectural feature served also as a reservoir to use in case of fire that generally would follow a temblor. It was connected to the water system of the hotel and conserved the roof water. Earthquakes had always torn piping and wiring apart where laid in the structure and had flooded or charged the building. In the Imperial, all piping and wiring were laid free of construction in covered concrete trenches in the ground of the basements, independent of even the foundations. When the earthquake is violent, fire finishes the terrible work. - FLW Pool at entrance of the Imperial

The Great Kanto Earthquake : On 1 September 1923, a little over only one year after the Imperial s completion, the test of the hotel s structure came, as one of the worst earthquakes in history hit the Kanto plain destroying Tokyo, Yokohama and the surroundings. Over 140,000 people fell victim to this earthquake and the fires it caused. Although many other buildings did not, the Imperial survived. Through innovation and careful consideration of the structure, the hotel stood firm among the rubble of its surroundings. The hotel served as a shelter for many homeless Japanese. In came the cablegram from the owner of the Imperial Hotel to Wright:

Bibliography :

Bibliography : Futagawa, Yukio. Frank Lloyd Wright The Imperial Hotel, Tokyo, Japan. 1915-1922. Tokyo, Japan: A.D.A. Edita 1980. Hoto, Julius. Imperial Hotel, Tokyo, Japan. Architectural Record Jan-June 1924: 118-123. Reitherman, Robert King. Frank Lloyd Wright s Imperial Hotel: A Seismic Re-evaluation. NISEE National Information Service for Earthquake Engineering. <http://nisee.berkeley.edu/kanto/kanto.html> James, Charles. The 1923 Earthquake and Fire. NISEE National Information Service for Earthquake Engineering. <http://nisee.berkeley.edu/kanto/tokyo.html> Kengelbacher, August. Great Kanto Earthquake 1923. Schauwecker s Guide to Japan. <http://www.japan-guide.com/a/earthquake/> Watson, James. Seismic Foundation Design. Department of Civil Engineering Earthquake Engineering. Sept. 2003. <http://www.cen.bris.ac.uk/civil/students/eqteach97/design2.htm>