Microflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350

Similar documents
Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Agilent 6430 Triple Quadrupole LC/MS System

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Electron Capture Detector for GC-2010 Plus

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

ENHANCED MS WITH THE TURN OF A KEY

High Levels of Sensitivity and Robustness for Complex and Demanding Matrices SCIEX TRIPLE QUAD 5500 SYSTEM

Pharmacokinetic Analysis of the mab Adalimumab by ELISA and Hybrid LBA/LC/MS: A Comparison Study

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

TurboMass GC/MS Software

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Bioanalysis of Intact Therapeutic Monoclonal Antibodies from Non-Human Primates Using MSIA D.A.R.T. S Technology

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Application Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Genotoxicity is the property of a compound

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

ICP Expert software. Technical Overview. Introduction

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

LC/MS Application Note

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Application Note LCMS-87 Automated Acquisition and Analysis of Data for Monitoring Protein Conjugation by LC-MS Using BioPharma Compass

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Method Development Considerations for Reversed-Phase Protein Separations

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Bioanalytical LC-MS of monoclonal antibody therapeutics

On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

MultiQuant Software Version 3.0

MassPREP On-Line Desalting Cartridge

Accelerate mab Characterization Using Automated Sample Prep

Peptide Mapping: A Quality by Design (QbD) Approach

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

AppNote 5/2006 ABSTRACT

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Elute LC series. Innovation with Integrity. UHPLC Precision for MS applications LC-MS

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

Application Note 00394

DISCOVERY AND VALIDATION OF TARGETS AND BIOMARKERS BY MASS SPECTROMETRY-BASED PROTEOMICS. September, 2011

SMART Digest Kit User Manual. Version 2

Application Note. Abstract. Authors. Introduction. Environmental

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Development of an Immunoprecipitation and LC-MS/MS based Method for Quantifying the 105 kda Recombinant Protein SXN in Plasma.

Protein-Pak Hi Res HIC Column and HIC Protein Standard

SCION GC Series. The Gas Chromatographers Choice for Separations

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

CaptiveSpray nanobooster

Immunoassays and Mass Spectrometry: Transitioning Technology

Differential Scanning Calorimeter. DSC-60 Plus Series C160-E013A

Validation of a concentration assay using Biacore C

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Rapid Extraction of Therapeutic Oligonucleotides from Primary Tissues for LC/ MS Analysis Using Clarity OTX, an Oligonucleotide Extraction Cartridge

A universal chromatography method for aggregate analysis of monoclonal antibodies

Gas Chromatography Assignment Chem 543/443

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Improved Peptide Maps Using Core-Shell Media: Explaining Better Biopharmaceutical Applications With Kinetex C18 Columns

Increasing Sensitivity In LC-MS. Simplification and prefractionation of complex protein samples

HDX-MS at Waters Waters Corporation 1

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

SCION GC Series. The Gas Chromatographers Choice for Separations

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Userguide: SepFast Gel Filtration columns

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Transcription:

Microflow Liquid Chromatography Mass Spectrometry System Nexera Mikros C146-E35

Micro: Above and Beyond Nano The High Sensitivity You Expect from a Low Flow System with the Ruggedness of HPLC Covering the Complete Range from Micro to Semi-Micro

Improved Detection Limits with Microflow Monoclonal Antibody Bioanalysis Nexera Mikros and nsmol Antibody BA Kit nsmol (nano-surface and molecular orientation limited proteolysis) is a proprietary, ground-breaking process that enables selective proteolysis of the Fab region of antibodies using trypsin-immobilized nanoparticles. Fab-derived peptides are quantified via MRM measurement on a high-sensitivity mass spectrometer. The Nexera Mikros system achieved signal intensities 12 times higher than with conventional flow rates, with a corresponding lower limit of detection of.25 μg/ml and good linearity. The Nexera Mikros system is ideal for low-level quantitation of peptides by LCMS. Nanoparticle (FG beads Trypsin DART) Trypsin-immobilized Diameter: 2 nm LCMS Analysis Captured Antibody Fab Oriented toward Solution Antibody Fab IgG collection Limited Trypsin Access Collection of Fab-derived peptide Decreases sample complexity Prevents contamination from excess proteolysis Diameter: 1 nm Immunoglobulin collection resin The following is an example of antibody drug analysis in plasma. The plasma spiked with trastuzumab was pretreated using nsmol Antibody BA Kit. In the analysis of signature peptides deriving from trastuzumab, Nexera Mikros provides a dynamic range of.763 62.5 μg/ml, good linearity with R 2 >.99, and excellent accuracy of 11.% (average). 1 Blank.763 μg/ml Calculated Conc. [μg/ml] * 1 1 1.1.1 R 2 =.9998 8 6 4 2 8 6 4 2.1.1 1 1 1 Set Conc. [μg/ml] * 1 Linearity (.763 to 62.5 μg/ml) 3. 3.5 3. 3.5 Chromatogram (4 μl/min) The intra-day reproducibility of this trastuzumab-derived-peptide analysis is summarized in the table below. These results show an excellent reproducibility, with both of accuracy and precision within 2 % at LLOQ and within 15 % even at other concentrations. Concentration Setting (μg/ml).763.229 5.86 5. Accuracy 97.1% 12% 16% 94% QC set 1 * 2 Repeatability 5.69% 6.68% 2.67% 6.36% Accuracy 1% 11% 99.4% 91.7% QC set 2 * 2 Intra-Day Reproducibility Evaluation Results from QC Samples Repeatability 11.3% 2.84% 3.12% 7.23% *1: This curve is drawn on logarithmic scale. *2: QC sets 1 and 2 were analyzed over a 2-day period, with each set of concentrations analyzed five times.

Improved Detection Limits with Microflow High Sensitivity Analysis of Lipid Mediators Lipid mediators are bioactive lipids produced in trace quantities in biological body. They are deeply involved in allergic reactions and inflammatory responses. In inflammatory processes, multiple lipid mediators are mutually correlated, and the inflammatory induction or regression reaction is facilitated by the induction or termination of their production. In these processes, a high sensitivity analysis is required in order to correctly evaluate lipid mediators, as their concentrations in biological body fluctuate significantly. The analysis data shown below is representative for five standard lipid mediators, including leukotriene and HETE. Micro-flow conditions produce a 1-fold increase in sensitivity compared to semi-micro flow rates in both positive and negative mode. Also presented are results for a) 2-HETE, b) 5,6-DiHETE, and c) LTD4, which were spiked in plasma from a trace quantity (5 fg) standard product, as well as d) intrinsic LTD4 in plasma. The lipid mediators a), b), and c) spiked in plasma were confirmed at micro flow rates. 1, 3. 2. 1. LTD4 LTB4 5,6-DiHETE 2-HETE 12-HETE 11.5 14.5 Height Improvement Ratio (Times) 4. 35. 3. 25. 2. 15. 1. 5.. 33.4 LTD4(+) 19.5 2-HETE( ) 12.2 12-HETE( ) 15.1 14.3 LTB4( ) 5,6-DiHETE( ) Chromatogram (1 ng/ml) Lipid Mediator Sensitivity Improvement Ratio 5, 1,5 4 μl/min 5, 1,5 4 μl/min 12.75 13.5 15.75 16.5 12.75 13.5 15.75 16.5 Red: 5 pg/ml Black: Blank Red: 5 pg/ml Black: Blank Red: 5 pg/ml Black: Blank Red: 5 pg/ml Black: Blank a) 2-HETE (Fortified in Plasma, 1 μl Injection) b) 5,6-DiHETE (Fortified in Plasma, 1 μl Injection) 1, 5 4 μl/min 1, 5 4 μl/min 11.5 12.5 12.5 13.5 11.5 12.5 12.5 13.5 Red: 5 pg/ml Black: Blank Red: 5 pg/ml Black: Blank c) LTD4 (Fortified in Plasma, 1 μl Injection) d) LTD4 (Endogenous, Blank 5 μl Injection) 4

Incomparable Microflow Ruggedness Realize the Benefits of Microflow While Enjoying the Ruggedness and Reliability of HPLC The Nexera Mikros system delivers the improvements you expect from a low-flow system with the ruggedness of HPLC. A plasma blank was protein precipitated, diluted (3x), and injected 1,5 times consecutively. During the consecutive injections, QC sample (4 ppt of nortriptyline) was injected once every 5 injections of plasma blank. Peak areas and retention times of QC sample are plotted below. With 4.38% RSD area repeatability and.25% RSD retention time stability, extremely stable operation was demonstrated, without loss of peak shape common in high-throughput analyses of complex matrices. *Results obtained under our application conditions. 7, 6, 5, Area Value: 4.38 %RSD Area Value 4, 3, 2, 1, 3 6 9 1,2 1,5 Number of Blood Plasma Injections Area Repeatability of QC Samples 5 Retention Time (min) 4 3 2 1 Retention Time:.25 %RSD 3 6 9 1,2 1,5 Number of Blood Plasma Injections Retention Time Reproducibility of QC Samples 1,5th injection 1..75 ( 1,) 1st injection 75th injection.5.25. 3.5 4. 4.5 min Chromatograms from 1st, 75th, and 1,5th Injections Nexera Mikros Microflow Liquid Chromatography Mass Spectrometry System 5

Easy, Familiar Operation Robust and Easy-to-Use Microflow ESI Source Micro-ESI 86 + CTO-Mikros Shimadzu s Micro-ESI LCMS source has been designed for optimal sensitivity and ease of use. An X Y adjustable stage and viewing camera allow for easy ESI spray needle adjustment. The column oven is mounted on the LCMS to minimize the volume between the exit of the column and the ESI needle. The Micro-ESI probe also features an ESI spray angle optimized for micro flow rates, and is compatible with LCMS-845/85/86 systems. Mounted to the Micro-ESI source is the CTO-Mikros column oven. Stable column temperature, essential to retention time reproducibility, is ensured and columns up to 15 mm in length can be accommodated. To preserve the optimal source adjustment, the CTO-Mikros features an innovative snap-in column locking system, the UF-Link. UF-Link : Easy, Dependable Column Installation When using microflow rates, even the smallest of dead volumes can cause significant diffusion and lead to loss of peak shape and sensitivity. Shimadzu s UF-Link allows any user to correctly install a microflow column without disrupting the ESI spray needle position. A sure-sealing adapter allows the column to lock into the oven and make a zero-dead volume connection with the ESI needle. Any column up to 15 mm in length with standard fittings can be accommodated. Existing Ferrule Seal Method Male nut Ferrule Zero Dead Volume Seal Adapter Dead volume Sealing part Sealing part Connection Procedure (1) Attach the adapter to the column. Standard threads on the adapter make it compatible with a wide variety of columns. (2) Place the column in the UF-Link mechanism inside the oven. (3) Complete the connection by swinging over the lever. 6

LC-Mikros: Innovative Microflow Pump Design Shimadzu LC pumps are the industry standard for long life and high performance. The LC-Mikros solvent delivery pump has completely new direct-drive engineering to deliver micro to semi-micro flow rates ranging from 1 to 5 μl/min. UHPLC system pressure tolerance of 8 MPa (11,6 psi) allows the use of every column type. The LC-Mikros pump is designed for microflow gradient elution, even at low percentages. In the example below, excellent gradient stability is shown using mobile phase compositions ranging from 1% to 9%. The LC-Mikros delivers stable retention times essential to the chromatographer. Gly-Tyr Val-Tyr-Val Angiotensin II Leu enkephalin Met enkephalin Average Retention Time 5.31 7.97 9.32 9.71 1.5 Standard Deviation.9.6.15.11.12 RSD.16%.7%.16%.11%.11% Flowrate: 5 μl/min Column: Shim-pack MC C18 (.3 mm I.D. 15 mm) *Obtained under our specified conditions. Time (min) Concentration B 1 1% 11 4% 11.1 9% 13 9% 13.1 1% 25 1% SIL-3AC: Low-Volume Direct Injection Autosampler The SIL-3AC autosampler delivers you excellent accuracy and reproducibility as well as extremely low carry-over. Its injection volume ranges from.1 to 5 μl and your precious sample has never wasted due to the total injection method SIL-3AC adapted. It contributes to produce highly accurate results even if you had to use low injection volume (less than 1 μl). In case of micro flow rate with narrow column, optimum injection volume also gets lowered. It is also difficult to increase the injection volume, especially, if you would use a sample solvent with high elution power. In this case, sample must be diluted to weaken the sample solvents. Highly accurate micro volume injection capability of SIL-3AC allows you to use samples with high organic solvent contents without dilution. System volume and gradient delay are minimized with the newly developed programmable loop cut-off mechanism, which automatically diverts the sample loop from the flow line using a high-pressure valve as soon as the sample in needle is drained. This is extremely important in minimizing microflow analysis run times. Area Value 2,5, R 2 =.999795 2,, 1,5, 1,, 5,. 1. 2. 3. 4. 5. 6. Injection Volume (μl).1.2.5.7 1 Repeatability (n = 6).67%.32%.26%.14%.11% Injection Volume (μl) 2 5 1 2 5 Repeatability (n = 6).9%.5%.5%.4%.3% Injection Volume (μl) Injection Repeatability (Actual Values) Nexera Mikros Microflow Liquid Chromatography Mass Spectrometry System 7

System Configuration Options Nexera Mikros Direct Injection System Ideal for sample volume-limited analyses. This system provides rapid and highly sensitive micro LCMS analysis without sample loss. Trap and Elute System Ideal for analyses with larger injection volumes or when some degree of sample cleanup is desirable. Make-Up Flow System The addition of a post-column make-up flow pump allows mobile phase modifiers to be added to ensure the highest ionization efficiency in the MS source. Nexera, nsmol, LCMS, UF-Link and Shim-pack are trademarks of Shimadzu Corporation. FG beads is a registered trademark of Tamagawa Seiki Co., Ltd. and National University Corporation Tokyo Institute of Technology. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol TM or. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 218 First Edition: January 218, Printed in Japan 3655-1174-2ANS