B22-SUB Manual 1.2 en

Similar documents
B B6-SUBManual 1.2 en

xs 4S/5SManual 1.4 en

General information Keep this manual with the product or in a safe place so that it is available for future reference.

J J8/J12Manual 2.2 en

Z5386 V Stack adapter Rigging manual (1.1 EN)

Z5377 E6 Swivel bracket Mounting instructions (1.2 EN)

Z5378 E6 Horizontal bracket Mounting instructions (1.0 EN)

Z5017 TV spigot HD Mounting instructions (4.0EN)

Z5352 E12 Flying bracket Mounting instructions (1.0 EN)

Z5043 MAX Horizontal bracket Mounting instructions

Z5033 E3 Ball joint adapter Mounting instructions

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

CELLO, LTD. SERAFIN ACTIVE SPEAKERS OWNER'S MANUAL

2 Ohm Nominal Component Speaker System OWNER S MANUAL

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Installation booklet

Adjustable Fused Power Supply

AN-S2 MOVING COIL STEP UP TRANSFORMER OWNER S INFORMATION

Accordion Doors / Zone 2. Woodfold Accordion Door Guide for Commercial and Residential Installations Detailed Architectural Shop Drawings Available

HotSwap MBP Maintenance Bypass

Studio Series. Installation Manual

CM-BHA Beltpack Headphone Amplifier with Limiter & Loudspeaker. User Handbook

Dual Port isolated USB Charger

Enclosure Installation Manual

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

Documentation. Transient voltage suppressor - AX2090- TS Version: Date:

RapID Raw Materials Verification System

SAFETECH 3.2K ST v1.0. User s manual. Opale-Parachutes.com. Please read this manual before first use.

2-finger angular gripper SGB 32-50

S-60-TO : 1 ton tower system

ENGINEERED SOLUTIONS SAFETY INSTRUCTIONS FOR STRUCTURAL PLATE PRODUCTS

U7242A USB3.0 Test Fixture

Sensor unit MC2 for toxic gases and oxygen with analog output

Sure-EarsTM. Wi Sure-Ears In-Ear Reference Monitors Optimized for Bass, Drums & Keyboards

Recommended Hole Pattern: [mm]

USER'S GUIDE TO OPERATION

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

AXIS T91G61 Wall Mount

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Agilent 16047D Test Fixture

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

Installation Instructions

Owner's manual SAX-1200D SAZ-1500D SAZ-2500D SAZ-3500D

UIW RCS II. Reference Series In-Ceiling Speaker. Congratulations. Owner s Manual

VBC Manual MManualManual. Installation and user manual for the VBC

KLIPSCH HOME SERIES A R C H I T E C T U R A L L O U D S P E A K E R S O w n e r s M a n u a l a n d W a r r a n t y

Years. Sound to behold. d&b ArrayCalc simulation software V8 featuring ArrayProcessing. Welcome to System reality.

MD Power Supply -48Vdc +Bias Tee

Section 5 Roller Chain Drive Components

DT 23 DT 24 DT 32 DT 33 DT 34 DT 44

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

ARC STUD WELDING SYSTEMS

! CAUTION: Read and follow these instructions.

About ebm-papst. Six reasons that make us the ideal partner:

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

Extended-Frequency SMA Connectors

S-60-MI2 : 500kg mini tower system v.2

VPL-3200B Residential Vertical Platform Lift Technical Specifications

USER MANUAL FOR MORE INFORMATION

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

2-Finger-Parallel-Gripper RH

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description

Cavity wall & Ceiling Installation guide for Amina Edge Invisible loudspeakers

Energy & Data Transmission Systems for Underground Applications

44XT Titanium Compression Driver (patented)

Product Manual (Revision A) Original Instructions. Digital Frequency Control. Installation and Operation Manual

Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

NCE Energy saving circulating pumps

HEAVY DUTY WELDING CART

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

ifix INSTALLATION MANUAL PV flat roof installation system Version

Shackles. Applications. Range. Design. CAD drawings. Finish

SPEAKER SC-COBRA

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

LSA 53.2 Low Voltage Alternator - 4 pole

ASSEMBLY INSTRUCTIONS for DATASAFE TM HX and HX FRONT TERMINAL UBC BATTERY RACKS

USER S MANUAL 400W and 600W

PD662 Loop-Powered Meter Instruction Manual

WE-CMBNC Common Mode Power Line Choke Nanocrystalline

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

AHP WELDS USER MANUAL

PRODUCT CONFORMITY CERTIFICATE

Installation and Operation Manual

Drag Chain Conveyor Installation and Operation Manual

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Gerber M Series Site Requirements

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

1. GENERAL INFORMATION CAUTIONS AND GENERAL NORMS DESCRIPTION AND INTENDED USE MARKING OF DTW WEIGHBRIDGES...

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

TECHNICAL SPECIFICATION

HOBO Plug Load Logger (UX ) Manual

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

P a c k a g i n g s o l u t i o n s f o r e l e c t r o n i c s

Transcription:

B B22-SUB Manual 1.2 en

General information B22-SUB Manual Version: 1.2 en, 03/2016, D2729.EN.01 Copyright 2016 by d&b audiotechnik GmbH; all rights reserved. Keep this manual with the product or in a safe place so that it is available for future reference. When reselling this product, hand over this manual to the new owner. If you supply d&b products, please draw the attention of your customers to this manual. Enclose the relevant manuals with the systems. If you require additional manuals for this purpose, you can order them from d&b. d&b audiotechnik GmbH Eugen-Adolff-Strasse 134, D-71522 Backnang, Germany T +49-7191-9669-0, F +49-7191-95 00 00 docadmin@dbaudio.com, www.dbaudio.com

Contents 1. Safety precautions... 4 1.1. Information regarding the use of loudspeakers... 4 2. B22-SUB loudspeaker... 5 2.1. Product description... 5 2.2. Connections... 5 2.3. Operation... 6 2.3.1. Controller settings... 6 2.4. Technical specifications... 7 3. Manufacturer's declarations... 8 3.1. EU conformity of loudspeakers (CE symbol)... 8 3.1.1. WEEE Declaration (Disposal)... 8 d&b B22-SUB Manual 1.2 en 3

1. Safety precautions 1.1. Information regarding the use of loudspeakers Potential risk of personal injury Never stand in the immediate vicinity of loudspeakers driven at a high level. Professional loudspeaker systems are capable of causing a sound pressure level detrimental to human health. Seemingly non-critical sound levels (from approx. 95 db SPL) can cause hearing damage if people are exposed to it over a long period. In order to prevent accidents when deploying loudspeakers on the ground or when flown, please take note of the following: When setting up the loudspeakers or loudspeaker stands, make sure they are standing on a firm surface. If you place several systems on top of one another, use straps to secure them against movement. Only use accessories which have been tested and approved by d&b for assembly and mobile deployment. Pay attention to the correct application and maximum load capacity of the accessories as detailed in our specific "Mounting instructions" or in our "Flying system and Rigging manuals". Ensure that all additional hardware, fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor. Pay attention to the manufacturers' instructions and to the relevant safety guidelines. Regularly check the loudspeaker housings and accessories for visible signs of wear and tear, and replace them when necessary. Regularly check all load bearing bolts in the mounting devices. Potential risk of material damage Loudspeakers produce a static magnetic field even if they are not connected or are not in use. Therefore make sure when erecting and transporting loudspeakers that they are nowhere near equipment and objects which may be impaired or damaged by an external magnetic field. Generally speaking, a distance of 0.5 m (1.5 ft) from magnetic data carriers (floppy disks, audio and video tapes, bank cards, etc.) is sufficient; a distance of more than 1 m (3 ft) may be necessary with computer and video monitors. 4 d&b B22-SUB Manual 1.2 en

2. B22-SUB loudspeaker 2.1. Product description The B22-SUB is an actively driven subwoofer housing a pair of 18" long excursion neodymium LF drivers built into a bandpass horn cabinet. Its frequency response extends from 32 Hz to 90 Hz. The cabinet is constructed from marine plywood and has an impact resistant paint finish. The front of the loudspeaker cabinet is protected by a rigid metal grill backed by an acoustically transparent foam. Each side panel incorporates four handles and mounted on the rear panel are four heavy duty wheels. The enclosure features two runners recessed in the bottom panel to protect the bottom panel from scratching. Two correspondingly shaped recesses are incorporated into the top panel of each B22-SUB cabinet to accept these runners, preventing cabinet movement when stacked. 2.2. Connections The cabinet is fitted with NLT4 F/M connectors. All four pins of both connectors are wired in parallel. The B22-SUB uses the pin assignments 2+/2. Pins 1+/1 are designated to TOP cabinets. In Mix TOP/SUB mode, when one connector is used as the input, the second connector allows for direct connection (link) to a TOP cabinet. Note: Only one B22-SUB may be connected. The second connector socket must not be used to link another B22-SUB cabinet. The cabinet can be supplied with EP5 connectors as an option. Pin equivalents of the connector options are listed in the table below. NLT4 F/M 1+ 1 2+ 2 n.a. EP5 1 2 3 4 5 (SenseDrive) NLT4 F/M and EP5 connector wiring d&b SenseDrive The SenseDrive feature within D12 amplifiers enables electrical compensation for the properties of the loudspeaker cable used. SenseDrive requires an additional sense wire. SenseDrive is therefore only available with EP5 connectors and 5-wire cabling for applicable loudspeakers. Note: When the D12 is operated in "Mix TOP/SUB mode", the SenseDrive function is only available at the output B connector. d&b LoadMatch Starting with the D80 amplifier platform, the LoadMatch function enables the amplifier to electrically compensate for the properties of the loudspeaker cable used without the need for an additional sense wire. For applicable loudspeakers, LoadMatch is therefore independent of the connector type used. d&b B22-SUB Manual 1.2 en 5

2.3. Operation NOTICE! Only operate d&b loudspeakers with a correctly configured d&b amplifier, otherwise there is a risk of damaging the loudspeaker components. Applicable d&b amplifiers: D80/D20/D12/30D. Application Setup Cabinets per channel B22-SUB B22-SUB 1 Within applicable d&b amplifiers, the controller setup is available in Dual Channel or Mix TOP/SUB mode. 2.3.1. Controller settings For acoustic adjustment the INFRA and CSA function can be selected. INFRA circuit Selecting the INFRA circuit restricts the frequency response to a narrow 32 Hz 68 Hz range ( 5 db). This transforms the B22-SUB into an infrabass system. CSA mode The CSA (Cardioid Subwoofer Array) mode enables the combination of three or multiples of three subwoofer cabinets into an array which produces exceptional low frequency directivity control. CSA Stack (example) The amplifier channel for the center subwoofer of the array, which is physically pointed to the rear, has CSA selected. The forward facing cabinets are driven with an amplifier channel set to standard mode. The resulting cardioid behavior of the array will significantly reduce the energy radiated to the rear. For further information, please refer to the d&b TI 330 Cardioid Subwoofer Array, which is available for download at www.dbaudio.com. 6 d&b B22-SUB Manual 1.2 en

2.4. Technical specifications B22-SUB system data Frequency response ( 5 db standard) Frequency response ( 5 db INFRA mode) Max. sound pressure (1 m, free field) with D12/D20/30D with D80 37 Hz - 90 Hz 32 Hz - 68 Hz 140 db 143 db (SPLmax peak, pink noise test signal with crest factor of 4) B22-SUB frequency response, standard and INFRA modes B22-SUB loudspeaker Nominal impedance Power handling capacity (RMS/peak 10 ms) Components Connections 4 ohms 1000/4000 W 2 x 18" driver with neodymium magnet 2 x NLT4 F/M optional 2 x EP5 Pin assignment NLT4 F/M: 2+/2 Weight EP5: 3:+ / 4: 106 kg (234 lb) B22-SUB cabinet dimensions in mm [inch] d&b B22-SUB Manual 1.2 en 7

3. Manufacturer's declarations 3.1. EU conformity of loudspeakers (CE symbol) This declaration applies to: d&b B22-SUB loudspeaker, Z0057 manufactured by d&b audiotechnik GmbH. All production versions of these types are included, provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications. We herewith declare that said products are in conformity with the provisions of the respective EC directives including all applicable amendments. A detailed declaration is available on request and can be ordered from d&b or downloaded from the d&b website at www.dbaudio.com. 3.1.1. WEEE Declaration (Disposal) Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime. Please dispose of this product according to the respective national regulations or contractual agreements. If there are any further questions concerning the disposal of this product, please contact d&b audiotechnik. 8 d&b B22-SUB Manual 1.2 en

www.dbaudio.com D2729.EN.01, 03/2016 d&b audiotechnik GmbH