DECISION TO ACCREDIT

Similar documents
ISTA Accreditation Standard for Seed Testing and Seed Sampling

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

ISO General Requirements for Competence of Testing Laboratories Procedure

ISO GUIDE 34: 2009 WORKING DOCUMENT

TECHNICAL REQUIREMENTS (CLAUSE 5)

Overview of Good Food Laboratory Practices

ISO/IEC 17025:2017 Working Document Instruction Page

0. 0 TABLE OF CONTENTS

IECEE OPERATIONAL DOCUMENT

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

ISO/IEC CHECKLIST FOR VERIFICATION LABORATORIES

Association of American Railroads Quality Assurance System Evaluation (QASE) Checklist Rev. 1/12/2017

QUALITY MANUAL. This document defines the requirements, processes, structure and documentation for the Teledyne DGO Quality Management System.

Quality Assurance Manual January 2008 Revision M Revision date of 04/03/17. Pi Tape Texas, LLC

Application for Accreditation General Laboratories ISO/IEC 17025

ISO/IEC FDIS INTERNATIONAL STANDARD FINAL DRAFT. General requirements for the competence of testing and calibration laboratories

Handbook ISO/IEC 17025:2017

A2LA. R104 - General Requirements - ISO-IEC Accreditation of Field Testing and Field Calibration Laboratories

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 5/06/08

QUALITY SYSTEM MANUAL

UPGRADE ASSESSMENT CHECKLIST

Document Number: QM001 Page 1 of 19. Rev Date: 10/16/2009 Rev Num: 1. Quality Manual. Quality Manual. Controlled Copy

PRESENTATION OVERVIEW

The new ISO/IEC 17025:2017

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

Vendor Qualification Survey

ISO 9001: 2000 (December 13, 2000) QUALITY MANAGEMENT SYSTEM DOCUMENTATION OVERVIEW MATRIX

CORPORATE QUALITY MANUAL

Accreditation of Reference Material Producers

ISO 22000:2005 Standard INTERNATIONAL STANDARDS REGISTRATIONS

APS Cleaning Quality Management System Scope of Certification The provision of commercial and industrial cleaning services throughout Queensland.

INTERNATIONAL STANDARD

General Requirements for the Competence of Testing and Calibration Laboratories

Quality Management System

SANAS Accr. No/s. F Date/s of evaluation

Air Monitoring Directive Chapter 5: Quality System

General requirements for the competence of testing and calibration laboratories. In this presentation:

EPICOR, INCORPORATED QUALITY ASSURANCE MANUAL

EVANS CAPACITOR COMPANY

HACCPEUROPA PUBLICATIONS ISO 22000:2005 FOOD SAFETY QUALITY MANUAL. ISO 22000:2005 Quality Manual

SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE

AEROSPACE STANDARD. Quality Systems - Aerospace - Model for Quality Assurance in Design, Development, Production, Installation and Servicing

American Association for Laboratory Accreditation

Revision. Quality Manual. Multilayer Prototypes. Compliant to ISO / AS9100 Rev C

AAMI Quality Systems White Paper: Comparison of 21 CFR Part 820 to ISO 13485:2016 1

Humantech Environmental Management System Manual

Desk Audit of. Based on Federal Transit Administration (FTA) Quality Assurance and Quality Control Guidelines FTA-IT

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

Machined Integrations, LLC

MODULE 2A GENERAL MANAGEMENT SYSTEM REQUIREMENTS

VERTICAL ASSESSMENT INSPECTION ISO/IEC 17020:2012

25 D.L. Martin Drive Mercersburg, PA (717)

FEC QUALITY MANUAL. Federal Equipment Company River Rd. Cincinnati, Ohio

Quality Manual Revision: C Effective: 03/01/10

QMS Team: MR and all HODs (Internal Auditors) MR March 10. Quality policy Define quality policy The Steering committee Objectives and targets

ISO 9001:2008 Quality Management System QMS Manual

Reliance Aerospace Solutions

FO-5 PR-1, FO-1,2 PR-1 EM-6 PR-1, FE-1, NA-1 FO-10 FO-7, EM-2 EM-2. ISO Environmental Management Systems - Specification Yes.

Rules for accreditation of providers of proficiency testing/interlaboratory

Correspondence between ICMED criteria and ISO 13485: 2012

SRI RESEARCH/RATING QUALITY STANDARD

The following is an example systems manual from a low volume (TE, but not an automotive supplier) company.

Quality Manual DRAFT. Quality Management Plan Version A1 Date: <22/01/11> Page 1 of 17

SUPPLIER QUALITY REQUIREMENTS

Osprey Technologies, LLC. Quality Manual ISO9001:2008 Rev -

SADCAS POLICY ISO/IEC 17020:2012 TRANSITION

QUALITY SYSTEM MANUAL

EN39 TUBE ASSESSMENT REPORT. Assessment Summary

Quality management systems

CSA Group Products, Processes and Services Scheme

ISO 22000:2005 SYSTEMKARAN ADVISER & INFORMATION CENTER SYSTEM KARAN ADVISER & INFORMATION CENTER FOOD SAFETY MANAGEMENT SYSTEM ISO 22000:2005

INS QA Programme Requirements

FDA 21 CFR Part 820 vs. ISO 13485:2016 Comparison Table created by greenlight.guru

WHO Prequalification of In Vitro Diagnostics Programme

Quality Manual. Print Name Title Date Prepared by L Naughton QA Consultant 9 th April 09. Reviewed by Bernard Lennon Fire and Safety Officer

THE COMPLETE GUIDE TO ISO14001

SUPPLIER GUIDELINES MANUAL

AB. OUR ISO CONFORMANCE AUDIT QUESTIONNAIRES 8. ASSESS HOW WELL YOU CONFORM TO ISO S REMEDIAL REQUIREMENTS

Management System Manual International Compliance Group

Luminus Devices, Inc Quality Management Systems Manual ISO 9001:2008

MANUAL QUALITY CONTROL & QUALITY ASSURANCE

ISO 9001:2015. Quality Management System. Manual

ENVIRONMENTAL MANUAL Page 1 of 7. Section 4 - General Requirements of System (4.1)

General requirements for the competence of testing and calibration laboratories

REQUIREMENTS FOR ACCREDITATION OF INSPECTION BODIES

BROOKHAVEN NATIONAL LABORATORY SBMS Interim Procedure

Beaver Machine. Quality Manual

Quality Manual. This manual has been written to the ISO 9001:2000 International Quality Standard

INTERNATIONAL STANDARD

POLICY MANUAL FOR ISO 9001:2008. Document: PM-9001:2008 Date: April 7, Uncontrolled Copy

BS EN ISO 9001 QUALITY ASSURANCE MANUAL

OH&S MANAGEMENT SYSTEM CHECKLIST - AS 4801:2001 (STATUS A = Acceptable; N = Not Acceptable; N/A = Not Applicable)

TUV SUD BABT PRODUCTION QUALITY CERTIFICATION SCHEME

Guidelines for the assessment of the appropriateness of small interlaboratory comparisons within the process of laboratory accreditation

NR CHECKLIST Rev. 1. QAM IMP References NBIC Part 3, 1.8 Y N Y N a. Organization. Company Name/Certificate Number: Page 1 of 26

ANCHOR ISO9001:2008 RPR-004 MARINE SERVICES REQUIRED PROCEDURE NON-CONFORMING PRODUCTS

Correspondence Between ISO 13485:2016 and 21 CFR Part 820 QMS Requirements

QUALITY MANUAL. Number: M-001 Revision: C Page 1 of 18 THIS DOCUMENT IS CONSIDERED UNCONTROLLED UNLESS ISSUED IDENTIFIED AS CONTROLLED

Procedure 14 Internal Audits

Supplier Audit Procedure /2/17

Transcription:

DECISION TO ACCREDIT Determine the requirements of the regulator, legislation and customer s needs prior to deciding on the standard to implement. Process is based on the following: Top management s decision to be accredited Gap analysis Training of personnel Design the documentation ( incorporate the processes you follow and align to the standard) Implement the documentation ( ensure you comply to the procedures you write) Initiate contact with the accreditation body and start the application process. Monitor the process, perform an internal audit and determine gaps. Complete corrective action Continual implementation and maintenance of records Conduct another audit and management review Contact accreditation body to complete assessment. ISO 17025 - IN BRIEF Summary The ISO 17025 standard is comprised of 5 elements: 1. Scope 2. Normative References 3. Terms and Definitions 4. Management Requirements 5. Technical Requirements Elements 4 and 5 contain the actual accreditation requirements. 4. Management Requirements 4.1 Organisation 4.2 Management system 4.3 Document control 4.4 Review of requests, tenders and contracts 4.5 Subcontracting of tests and calibrations 4.6 Purchasing services and supplies 4.7 Service to client 4.8 Complaints 4.9 Control of nonconforming testing and/or calibration work 4.10 Improvement 4.11 Corrective action 4.12 Preventive action 4.13 Control of records 4.14 Internal audits 4.15 Management reviews 5 Technical Requirements Page 1 of 7

5.1 General 5.2 Personnel 5.3 Accommodation and environmental conditions 5.4 Test and calibration methods and method validation 5.5 Equipment 5.6 Measurement traceability 5.7 Sampling 5.8 Handling of test and calibration items 5.9 Assuring the quality of test and calibration results 5.10 Reporting the results ISO 17025 is not an easy read for anyone. The following pages summarize the key ideas in each element of the standard. 4.0 Management Requirements 4.1 Organisation Laboratory must be legally identifiable Identify permanent site, temporary sites or mobile facility Identify and outline the approach to eliminate potential conflicts of interest within the overall organization. Protect confidential and proprietary information pertaining to the customer and organisation Outline the manner/approach taken to avoid activities that would diminish confidence in the laboratory. Compile the organogram outlining the flow of responsibility, accountability and the interrelationships within the laboratory, with the focus from the parent organisation Discuss the roles and responsibilities of technical personnel and management. Appoint a quality manager for the laboratory. Appoint deputies for key managerial personnel. 4.2 Management System Establish a quality management system and document all policies, procedures, working instructions and forms/records. Create a Quality Manual, to include: a quality policy statement (management commitment to good professional practice, standards of service, objectives, personnel requirements, management commitment to comply with ISO 17025); structure of documentation ( outline the tiers); management roles and responsibilities. Ensure records are kept of all activities supporting your quality system. Top management has an imperative role within the QMS and as such there should be proper channels of communication and ensure that there are records of communication pertaining to ensuring the awareness and improvement to the QMS to the personnel 4.3 Document Control Write procedures that are valuable to the end user. Control all procedures and identify and track all documents( internal and external source) Create and maintain a Master List and distribution list of documents. Page 2 of 7

Ensure that only authorized documents are in use. Periodically review all documents and revise as necessary. Remove invalid or obsolete documents from use immediately. Uniquely identify each quality system document. Define and control the document revision process. 4.4 Review of Requests, Tenders, and Contracts Clearly understand customer requirements. Keep records of review. Review sub-contracted work. Notify customer of any deviations from the contract. Amend contracts as necessary, repeat the review process, and ensure that amendments are communicated to all affected personnel. 4.5 Subcontracting of Tests and Calibrations Choose competent subcontractors who comply with ISO 17025 or provide a description of the process followed to audit the companies Notify the customer that subcontractors are being used. Subcontractors must be approved by the customer, preferably in writing whenever possible. Maintain the register of sub contractors and the evaluation documentation 4.6 Purchasing Services and Supplies Evaluate suppliers of goods and services that are critical to the quality of testing and calibration. Maintain records of the evaluation and approved suppliers list Inspect/verify goods and services before use. 4.7 Service to the Client Understand the customer's needs and keep them informed of delays or deviations. Seek feedback from the customer and utilize customer surveys. In most instances the decision to accredit is voluntary based on the requirements of the customer and if one of the key objectives of an organization is to ensure excellent service delivery then the process of evaluation must be designed to ensure that the organization is able to meet/exceed to the client s needs. 4.8 Complaints Have a procedure for resolving complaints. Record all complaints, investigations and responsible persons and actions taken. 4.9 Control of non-conforming testing/calibration work Page 3 of 7

Assign responsibility and authority for handling nonconforming work. Evaluate the significance of the non-conformity. Take timely corrective action. Notify the customer of non-conforming work if necessary. 4.10 Improvement Based on the evaluation of all the critical areas to allow for the enhancement of the QMS and continuing suitability 4.11 Corrective Action Find the "root cause" of all non-conforming work produced by the laboratory. Root cause analysis is complex and must be conducted with the aim of identifying the root cause and not superficially such as labeling the incident as negligence Select and implement the action most likely to eliminate the cause of the problem. Corrective action should be appropriate to the magnitude and risk of the problem. Monitor progress of the corrective action to ensure effectiveness. Document and implement any changes indicated by the corrective action. Evaluate the seriousness of the non conformity and schedule an audit of the laboratory if the nonconformity brings laboratory integrity into question. 4.12 Preventive Action Identify and record needed improvements and potential non-conformities identified during the course of work. Plan and implement action plans for preventive action. Ensure effectiveness of the preventive action and monitor process. 4.13 Control of Records Keep records of the quality management system and of technical activity. Store, access and dispose the records suitably. Establish retention times. Mistakes in recording results will be crossed out and initialed, but not erased or colored over 4.14 Internal Audits Audit the laboratory's activities at least annually. Ensure that all the clauses/elements of the standard are addressed. Create the audit schedule If possible auditors should be independent of the audited facility. Ensure that trained and competent auditors are used. Keep records Ensure that the internal audit is conducted internally and is focused. Plan, prepare and conduct the audit to ensure that you identify gaps and correct accordingly. Take timely corrective action if problems are found. Follow up on corrective action to ensure its effectiveness. Page 4 of 7

4.15 Management Reviews Top management had set the objectives of the organization. Thus top management will periodically review the laboratory's quality system and activity. This will be conducted by reviewing all the critical areas which will allow one to determine if the objectives were met and to conclude on the effectiveness of the QMS and design action plans from the identified areas for improvements. 5.0 Technical Requirements 5.1 General Many factors contribute to the correctness and reliability of tests and/or calibrations. The laboratory must account for these factors. These factors include contributions from: human factors accommodation and environmental conditions test and calibration methods and method validation equipment measurement traceability sampling the handling of test and calibration items 5.2 Personnel Only competent, qualified personnel can execute procedures. Ensure all personnel are declared competent Formulate goals for the education, training, and skills of personnel. Identify training needs and provide training. Keep records of authorization, competence, qualifications, training, and experience of personnel. Maintain updated cv s, job descriptions for all personnel involved in tests or calibrations. 5.3 Accommodation and environmental conditions Provide proper power, lighting, and environment to facilitate work. Maintain the specified environment for testing. Monitor, control and record environmental conditions Prevent cross-contamination by separation of activities. Control the access to testing areas. Ensure good housekeeping. 5.4 Test and Calibration Methods and Method Validation 5.4.1 General Use appropriate test and calibration methods. Estimate the uncertainty of measurement where appropriate. Keep instructions for the use of all equipment up-to-date and readily available. Page 5 of 7

Deviation from established methods shall be documented and justified. 5.4.2 Selection of Methods Use validated test methods that are suitable for the task and which meet the needs of the customer. Methods published in international standards are preferred. Laboratory-developed methods may be used if they are validated. 5.4.3 Laboratory-developed methods The introduction of laboratory-developed methods will be planned and effective communication will be ensured. 5.4.4 Non-standard methods Non-standard methods will be approved by the customer and appropriately validated before use. 5.4.5 Validation of methods Validation requires objective evidence that the selected method meets the requirements. All test and calibration methods must be validated. Record the results of validation and the procedure used for validation. The range and accuracy of values obtainable from validated methods shall be relevant to the customer's needs. 5.4.6 Estimation of uncertainty of measurement Calibration and testing laboratories will estimate the uncertainty of all measurements. Where rigorous uncertainty analysis cannot be done, all relevant uncertainty components will be identified and a reasonable estimation of their magnitude will be made. 5.4.7 Control of data Calculations and data transfers shall be systematically checked. Validate and document all software written by laboratory personnel. Protect the data generated in the laboratory. Maintain the computers to ensure the integrity of test and calibration data. 5.5 Equipment Provide equipment that is capable of achieving the required accuracy. Calibrate equipment before use. Only authorized personnel will operate equipment. Maintain a calibration record for each piece of equipment. Protect and maintain equipment. Remove defective or questionable equipment from use. Examine the effect of having used defective or questionable equipment. Update software to reflect changes in equipment parameters or correction factors. Calibration status will be displayed on all equipment. Prevent unauthorized adjustment of equipment. Maintain the list of equipment and calibration program 5.6 Measurement Traceability Calibrate equipment before use. All equipment must have traceability to national standards. Page 6 of 7

Reference standards shall be calibrated by a suitable agency. 5.7 Sampling If sampling is employed, the sampling plan must be statistically justified. Document requests by the customer for deviations from the sampling plan. Follow procedures for sampling and record the results. 5.8 Handling of Test and Calibration Items Ensure that the procedure describes the transportation, receipt and handling, protection, storage, retention and disposal of items Identify all items, ensure unique markings/labeling On receipt of an item, inspect it for damage, abnormality, and suitability for testing. Provide safe storage facilities. 5.9 Assuring Quality of Test and Calibration Results Monitor and ensure the validity of tests/calibrations through: regular use of certified reference materials and/or internal quality control using secondary reference materials participation in inter-laboratory comparisons or proficiency testing programs replicate tests or calibrations using the same or different methods re-testing or re-calibration of retained items correlation of results for different characteristics of an item Quality control data should be analysed and trends identified, where there are out of limits, investigations and planned actions must be implemented to prevent incorrect results from being reported 5.10 Reporting Results Identify the process to follow for internal and/or external customers. For internal customers you may report in a simplified manner. Report the results of each test or calibration, note the relevant disclaimer. Test reports and calibration certificates shall include a list of the items tested. Calibration certificates shall include test conditions, measurement uncertainty and traceability. Page 7 of 7