Eurocode 8 Timber and Masonry structures

Similar documents
Seismic Behaviour of RC Shear Walls

4.6 Procedures for Connections

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

EN DK NA:2007

Cement grouted steel bars in glulam

mortarless masonry Design Manual Part 1 (BS 5628:2005) Section 1 Page 1 BS 5628:2005 CODE OF PRACTICE FOR THE USE OF MASONRY

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

Contents. 1.1 Introduction 1

A new ductile approach design of joints assembled with screw connectors

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

EXPERIMENTAL RESULTS

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Structural Dynamics and Earthquake Engineering

DUCTILITY REQUIREMENTS FOR BUILDINGS

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

CYCLIC BEHAVIOUR OF TRUSS TYPE REINFORCED CONCRETE MASONRY WALLS

Design for earthquake-resistent reinforced concrete structural walls

NON ENGINEERED REINFORCED CONCRETE BUILDINGSS

In-plane testing of precast concrete wall panels with grouted sleeve

HILTI HY 150 REBAR DESIGN GUIDE

Chapter. Masonry Design

Interaction between ductile RC perimeter frames and floor slabs containing precast units

Displacement Based Assessment and Improvement of a Typical New Zealand Building by an Average Engineer

New ICC/ACI Design Concept for Post-Installed Reinforcement Bars Kelly Chua, B.Eng (Civil and Structural)

Cyclic behaviour of a full scale RC structural wall

HRC T-Headed Bars Advantages for the user

COST C26. Urban Habitat Constructions under Catastrophic Events EARTHQUAKE RESISTANCE WG 2 Session, March 30th

Design Guide Handbook for EN 1996 Design of Masonry Structures

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Modelling of RC moment resisting frames with precast-prestressed flooring system

Case Studies in Structural Engineering

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Renovation of Buildings using Steel Technologies (ROBUST)

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Infill Precast Panels as Retrofit System of Reinforced Concrete Frames

Evaluation of Earthquake Risk Buildings with Masonry Infill Panels

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

DS/EN DK NA:2013

E TA TECHNICAL REPORT. Design of Metal Anchors For Use In Concrete Under Seismic Actions. TR 45 Edition February 2013

CONCRETE BLOCK MASONRY

Technical Guidance Document TGD-021-6

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

EXPERIMENTAL STUDY OF THE DEFORMATION CAPACITY OF STRUCTURAL MASONRY

Product overview:

R-Group Finland Oy. REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

DIAPHRAGM BEHAVIOR OF DECONSTRUCTABLE COMPOSITE FLOOR SYSTEMS

The following excerpt are pages from the Hilti North America Post- Installed Reinforcing Bar Guide.

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

Seismic Detailing of RC Structures (IS: )

Introduction to Earthquake Engineering Behaviour of structures under earthquakes

This final draft of the fib MC2010 has not been published; it is intended only for the purpose of voting by the General Assembly.

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

pren : Redraft 9A

SHEAR BEHAVIOR OF RC BEAMS USING U-SHAPED UFC PERMANENT FORMWORK WITH SHEAR KEYS OR BOLTS

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS

Plan Check No. Checked by: An Appointment Is Required for Verification

Support Action for Strengthening PAlestine capabilities for seismic Risk Mitigation SASPARM 2.0 Deliverable D.C.1

HIGH PERFORMANCE REINFORCEMENT PRODUCTS. Product Catalogue.

NONLINEAR FINITE ELEMENT ANALYSIS OF NON- SEISMICALLY DETAILED INTERIOR RC BEAM-COLUMN CONNECTION UNDER REVERSED CYCLIC LOAD

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

0331 Brick and block construction

SECTION 1. AS MASONRY STRUCTURES CODE

Council on Tall Buildings

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

1. INTRODUCTION. Fig.1 Dimension of test specimen

Modelling the seismic response of light-timber-framed buildings

Eurocode 9: Design of aluminium structures

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

5.4 Analysis for Torsion

Survey and Testing of Pre-1988 Braced Frame Structures From The West Coast of the United States

EARTHQUAKE DESIGN CONSIDERATIONS OF BUILDINGS. By Ir. Heng Tang Hai

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

HOLLOW CORE FLOORS SPEED AND STRENGTH

Strengthening of infilled RC frames by CFRP

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

CVEN 483. Structural System Overview

SEISMIC RETROFIT OF REINFORCED CONCRETE BUILDINGS - A REVIEW AND CASE STUDY

> 0. 1 f, they are treated as beam-columns.

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

Shake-table test on a four-storey structure with reinforced concrete and unreinforced masonry walls

Special Reinforced Concrete Structural Walls

On detailing of reinforced-concrete frame structures for robustness and for earthquake resistance

Schöck Isokorb type CV

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

R-Group Finland Oy. RTA, RWTL and RWTS Lifting anchors Design instructions

Investigation of the behavior of stiffened steel plate shear walls with Finite element method

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Eurocode 6 Design of masonry structures

Seismic Design and Behaviour of Confined Masonry Buildings

Lysaght Bondek. Structural steel decking system Design and Construction Manual

European Technical Assessment ETA-10/0422 of 08/01/2016

Feasibility and Detailing of Post-tensioned Timber Buildings for Seismic Areas

HOW CONFINED MASONRY BUILDINGS FAIL IN EARTHQUAKES

Transcription:

Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 8 Timber and Masonry structures E C Carvalho, Chairman TC250/SC8

Brussels, 18-20 February 2008 Dissemination of information workshop 2 EN 1998-1 Section 8 Specific rules for timber structures

Brussels, 18-20 February 2008 Dissemination of information workshop 3 Timber is generally considered to be a good structural material for construction in seismic areas due to its: Light weight Reasonable strength in tension and in compression both being relevant properties for the seismic performance of structures

Brussels, 18-20 February 2008 Dissemination of information workshop 4 Typical values of unit mass and strength for various structural materials and corresponding ratios Structural material Wood Structural steel Concrete Reinforced concrete Masonry Compression and tension Unit mass ρ (kg/m 3 ) Strength f Range of values (MPa) Ratio f/ρ (10-3 MPa / kg/m 3 ) 550 20 30 35 55 Compression and tension 7800 275-355 35-45 Compression 2400 25-80 10-30 Tension 2400 2 3,5 0,8-1,5 Bending 2500 10-25 4-10 Compression 2100 4-8 1,9 3,8 Tension 2100 0,3 0,5 0,1-02

Brussels, 18-20 February 2008 Dissemination of information workshop 5 The good performance of wood is reflect by its range of values f/ρ similar to structural steel but timber elements do not present large deformational ductility response of timber elements up to failure is approximately linear elastic collapse is sudden, mostly associated with defects inherent to the natural origin of timber

Brussels, 18-20 February 2008 Dissemination of information workshop 6 For timber structures EN 1998-1 distinguishes between dissipative and low-dissipative structural behaviour (as for concrete, steel and composite) However, in view of the limited ability of timber to behave nonlinearly: Energy dissipation should be mostly in connections Timber elements should respond linearly Some (little) NL behaviour in compression perpendicular to grain may be expected. Tension perpendicular to grain markedly brittle.

Brussels, 18-20 February 2008 Dissemination of information workshop 7 Distinction between dissipative and low-dissipative structures depends mostly on the Nature of the connections: Basic distinction in EN1998-1 between: Semi-rigid joints Rigid joints

Brussels, 18-20 February 2008 Dissemination of information workshop 8 Dissipation of energy in connections: Two main sources: 1. Cyclic yielding of metallic (normally steel) dowel type fasteners of the connections (nails, staples, screws, dowels or bolts) Stable mechanism with large hysteretic cycles 2. Crushing of the wood fibres bearing against the dowel Thin hysteretic loops with significant degradation (due to the cavity being formed in front of the dowel)

Brussels, 18-20 February 2008 Dissemination of information workshop 9 Response of the connections depends mostly on the interaction between the two mechanisms Achieve good dissipative behaviour with proper balance between: Wood crushing Dowel yielding More significant parameter: Slenderness of the dowel type element

Brussels, 18-20 February 2008 Dissemination of information workshop 10 Ductility Classes Dissipative structures Ductility Class Medium (DCM) Ductility Class High (DCH) Low-dissipative structures Ductility Class Low (DCL) Choice of the DCs left to the designer but National Authorities may limit the use of the various DCs

Brussels, 18-20 February 2008 Dissemination of information workshop 11 Ductility classification depends mostly on: Structural type/redundancy Nature of structural connections Determine properties of dissipative zones by testing (pren 12512) or Use deemed to satisfy rules (in EN 1998-1)

Brussels, 18-20 February 2008 Dissemination of information workshop 12 Materials and properties of dissipative zones: General requirements as in EN 1995-1-1 (and EN 1993-1 for steel elements) Additional requirements for DCM and DCH Glued joints may not be considered dissipative Density of particle board panels 650 kg/m 3 Thickness of particle board and fibre board panels 13 mm Thickness of plywood sheating 9 mm Nailed shear panel systems superior to conventional bracing Avoid pull out of nails under transverse loading (avoid smooth nails or apply provisions against withdrawal)

Brussels, 18-20 February 2008 Dissemination of information workshop 13 Behaviour factors DCM and DCH (q = 1,5 for DCL) Structural types DCM DCH Wall panels with glued diaphragms connected with nails and bolts Glued panels q = 2,0 Wall panels with nailed diaphragms connected with nails and bolts Trusses Mixed structures with timber framing and non-load bearing infills Hyperstatic portal frame with doweled and bolted joints - Doweled and bolted joints q = 2,0 Nailed panels q = 3,0 Nailed panels q = 5,0 (q = 4,0) Nailed joints q = 3,0 q = 2,0 - μ 4 q = 2,5 μ 6 q = 4,0 (q = 2,5) ( ) for lower slenderness dowels

Brussels, 18-20 February 2008 Dissemination of information workshop 14 Underlying requirements for the allowed q factors for timber structures: Buildings regular in elevation (if non-regular, reduce by 20% the values indicated for q) Dissipative zones able to sustain, without strength degradation larger than 20%, 3 fully reversed cycles at ductility demand of: μ = 4 for DCM μ = 6 for DCH Rotational ductility in portal frames or distortional displacement ductility in shear panels

Brussels, 18-20 February 2008 Dissemination of information workshop 15 Deemed to satisfy rules for dissipative zones Fasteners in doweled, bolted and nailed timberto-timber and steel-to-timber joints: Slenderness: t/d 10 (or 8) Diameter: d 12 mm In shear walls and diaphragms: Wood-based material Slenderness of nails: t/d 4 (or 3) Nail diameter: d 3,1 mm More demanding than EN 1995 (allows dowels and bolts up to 30 mm) Allowance for lower slenderness (values) with reduction of the q factor

Brussels, 18-20 February 2008 Dissemination of information workshop 16 Detailing for DCM and DCH Dissipative zones in parts of the structure not affecting its overall stability Connections Connections in compression members prevented from separating Tight fitted bolts and dowels in pre-drilled holes. Maximum diameter of bolts and dowels: 16 mm (larger diameters allowed with toothed ring connectors for confinement) Dowels, smooth nails and staples with provisions against withdrawal Provisions against splitting (metal or plywood plates)

Brussels, 18-20 February 2008 Dissemination of information workshop 17 Detailing for DCM and DCH Increase the effectiveness of the sheating material and edge connections Diaphragms (rules more demanding than EN 1995-1-1) Disregard allowance in EN1995-1-1 for increased resistance and increased spacing of edge connectors Continuity of beams Height-to-width ratio (slenderness) of beams: t/d 4 (in the absence of transverse blocking) Reduce spacing of fasteners if a g S 0,2 g (respect minimum spacing of EN 1995-1-1; provide «generous» size of timber elements to allow space for nailing)

Brussels, 18-20 February 2008 Dissemination of information workshop 18 Safety verifications Resistance models in accordance with EN 1995-1-1 with k mod values for instantaneous loading DCL Partial factors γ M as for the fundamental load combination DCM and DCH Partial factors γ M = 1,0 as for the accidental load combination (important difference from concrete, steel and timber) Provide sufficient overstrength to elements connected to dissipative zones Increase partial factors by 1,3 in carpenter joints (to avoid brittle failures)

Brussels, 18-20 February 2008 Dissemination of information workshop 19 EN 1998-1 Section 9 Specific rules for masonry structures

Brussels, 18-20 February 2008 Dissemination of information workshop 20 Masonry is generally considered to present specific problems for construction in seismic areas due to its: Weight Poor strength in tension Brittle response in tension and compression all being relevant properties for the seismic performance of structures

Brussels, 18-20 February 2008 Dissemination of information workshop 21 Typical values of unit mass and strength for various structural materials and corresponding ratios Structural material Wood Structural steel Concrete Reinforced concrete Masonry Compression and tension Unit mass ρ (kg/m 3 ) Strength f Range of values (MPa) Ratio f/ρ (10-3 MPa / kg/m 3 ) 550 20 30 35 55 Compression and tension 7800 275-355 35-45 Compression 2400 25-80 10-30 Tension 2400 2 3,5 0,8-1,5 Bending 2500 10-25 4-10 Compression 2100 4-8 1,9 3,8 Tension 2100 0,3 0,5 0,1-02

Brussels, 18-20 February 2008 Dissemination of information workshop 22 The specific problems of the seismic performance of masonry is reflect by the low of values f/ρ both in compression and tension however Masonry structures may present: Densely distributed walls Good robustness (if all elements are appropriately tied together) Dissipation of energy in a distributed fashion by widespread cracking (which has to be controlled either by tying or by distributed reinforcement) Hence the seismic behaviour of masonry structures may be very much influenced by design

Brussels, 18-20 February 2008 Dissemination of information workshop 23 For masonry structures EN 1998-1 distinguishes between: Unreinforced masonry construction Confined masonry construction Reinforced masonry construction Unreinforced masonry akin to the concept of Low-Dissipative structures Use of unreinforced masonry (EN1996) is recommended only for Low seismicity cases (recommended NDP) Unreinforced masonry (EN1998-1) may not be used if a g S > 0,20 g (recommended NDP that should depend on the requirements for materials properties)

Brussels, 18-20 February 2008 Dissemination of information workshop 24 Materials and bonding patterns General requirements as in EN 1996-1-1 Additional requirements (all recommended NDPs) Minimum strength of units Normal to bed face: f b 5 N/mm 2 Parallel to bed face: f b 2 N/mm 2 Minimum strength of mortar Unreinforced and confined: f m 5 N/mm 2 Reinforced: f m 10 N/mm 2 Masonry bond for perpend joints Fully grouted joints with mortar Ungrouted joints Ungrouted with mechanical interlocking Large number of NDPs reflect and is intended to accommodate the large variety of materials and construction practices for masonry across Europe

Brussels, 18-20 February 2008 Dissemination of information workshop 25 Upper limits of behaviour factors (recommended NDPs) Type of construction Q Unreinforced masonry in accordance with EN 1996 alone 1,5 Unreinforced masonry in accordance with EN 1998 1,5 2,5 Confined masonry 2,0 3,0 Reinforced masonry 2,5 3,0

Brussels, 18-20 February 2008 Dissemination of information workshop 26 Structural analysis Uncracked or cracked (recommended) stiffness Cracked stiffness approx. 50% If appropriate (existance of coupling beams/spandrels) a frame analysis may be used Redistribution of base shear among walls

Brussels, 18-20 February 2008 Dissemination of information workshop 27 Construction rules and geometric conditions General Connections between floors and walls Floor continuity and effective diaphragm effect Shear walls in two orthogonal directions Shear walls Minimum effective thickness t ef,min Maximum height to thickness ratio (h ef /t ef ) max Minimum length to height ratio (l/h) min

Brussels, 18-20 February 2008 Dissemination of information workshop 28 Geometric requirements for shear walls Masonry type t ef,min (mm) (h ef /t ef ) max (l/h) min Unreinforced, with natural stone 350 9 0,5 units Unreinforced, with any other type 240 12 0,4 of units Unreinforced, with any other type of units, in cases of low 170 15 0,35 seismicity Confined masonry 240 15 0,3 Reinforced masonry 240 15 No restriction t ef thickness of the wall (EN 1996-1-1); h ef effective height of the wall (EN 1996-1-1); h l greater clear height of the openings adjacent to the wall; length of the wall.

Brussels, 18-20 February 2008 Dissemination of information workshop 29 Additional requirements for unreinforced masonry Horizontal concrete beams or steel ties at floor levels in all walls Concrete beams reinforcement with at least 2 cm 2 All beams (or ties) interconnected Peripheral beams essential

Brussels, 18-20 February 2008 Dissemination of information workshop 30 Additional requirements for confined masonry Horizontal and vertical confining elements bonded together and cast against the masonry Confining elements larger than 150 mm (interconnect the two masonry leaves in case of double-leaf masonry) Longitudinal reinforcement of confining elements with at least 3 cm 2 or 1% of cross sectional area Stirrups d 5 mm spaced 150 mm Reinforcing steel Class B or C (EN 1992-1-1) Lap splices longer than 60 diameters

Brussels, 18-20 February 2008 Dissemination of information workshop 31 Additional requirements for confined masonry (cont.) Vertical confining elements: At both edges of walls At both sides of openings larger than 1,5 m 2 Within wall spaced, at most, 5 m At wall intersections more than 1,5 from other confining element Horizontal confining elements: At every floor level With vertical spacing not larger than 4 m

Brussels, 18-20 February 2008 Dissemination of information workshop 32 Additional requirements for reinforced masonry Horizontal reinforcement in bed joints spaced not more than 600 mm Reinforcing steel not less than 4 mm in diameter, bent around bars at edges of walls Horizontal reinforcement not less than 0,05% of cross sectional area of wall Vertical reinforcement (in pockets or holes in the units) not less than 0,08% of cross sectional area of wall Reinforcing steel Class B or C (EN 1992-1-1) Lap splices longer than 60 diameters

Brussels, 18-20 February 2008 Dissemination of information workshop 33 Additional requirements for reinforced masonry (cont.) Vertical reinforcement not less than 200 mm 2 and provided with 5 mm stirrups at 150 mm spacing: At both free edges of all walls At every wall intersection Within wall spaced, at most, 5 m

Brussels, 18-20 February 2008 Dissemination of information workshop 34 Safety verifications Resistance models in accordance with EN 1996-1-1 Specific partial factor γ m for masonry and γ s for steel to be defined as NDPs Recommended values: For masonry: γ m = 2/3 of the value from EN 1996-1-1, but not less than 1,5 For steel: γ s = 1,0

Brussels, 18-20 February 2008 Dissemination of information workshop 35 Simple masonry buildings Concept applicable only for Importance Classes I and II Explicit safety verification not mandatory Safety verification implicit with the fulfilment of some geometrical conditions

Brussels, 18-20 February 2008 Dissemination of information workshop 36 Simple masonry buildings conditions: Maximum number of storeys and minimum relative area of walls depending on a g S and type of masonry Regularity in plan Compact in plan shape Shear walls in both orthogonal directions and approximately symmetrical Two parallel walls in both orthogonal directions, placed close to the edges of the building 75% of weight supported by shear walls Variation of mass and wall area between adjacent storeys limited to 20% (recommended NDP)