James R. Kirby, AIA Associate Executive Director, Technical Communications National Roofing Contractors Association (NRCA)

Similar documents
November 10, 2015 Baltimore, MD. presented by

Chicago Roofing Contractors Association

KEEPING UP WITH I-CODES

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Intumescent Coatings and Spray Polyurethane Foam

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

The Building Envelope Solution. Mike Lowery A&D Products, LLC

SECTION PREPARATION FOR RE-ROOFING

Thermal Bridging in Residential Construction

2015 IECC Whole Building Air Leakage Compliance

(Project Location) (your firm's name)

Maximizing the Value From Commercial Roof Systems. An Industry Report

/ TABLE OF CONTENTS /

Roof System. and Considerations. Environment friendly e-library

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

2013 COMMERCIAL PRODUCTS

Commercial Air Barrier Systems

Proponent: Steven William Harris, Quality Auditing Institute, representing Cedar Shake and Shingle Bureau

Thermoplastic Single Ply & Multi-Ply Roofing Systems

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Inspection of New One- and Two- Family Dwellings

ROOF SUBSTRATE PREP MANUAL

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Closed-Cell Spray Foam Insulation. Performance in Residential and Commercial Buildings During Adverse Weather

J. Paul Guyer, P.E., R.A.

Open and Closed Cell Spray Foam Insulation

REFLECTIVE INSULATION, RADIANT BARRIERS, AND INTERIOR RADIATION CONTROL COATINGS FOR USE IN PRE-ENGINEERED METAL BUILDINGS

Building Enclosure Performance for Existing and New Buildings

Sarnafil Adhered Single-Ply Roofing Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

Photovoltaic System Inspector Job Task Analysis Guide April 2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Code Compliance with Insulated Concrete Form Foundations

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

Integrated Air & Water Barrier Systems

Hardin County Planning and Development Commission

REQUEST FOR QUALIFICATIONS AND PROPOSALS. On Behalf of the Crawford County Board of Commissioners. for

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

ACFoam-II HCFC Free "Green" Polyiso Specification

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

Integrated Wall Retrofit Solutions for Existing Masonry Construction for Commercial Buildings

Chicago & IL Energy Code, Green, Garden Roofs, Energy and Drainage / Water Retention

Privacy Policy Please visit for the CARE and GAF Privacy Policy.

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

UNIFIED FACILITIES CRITERIA (UFC) ROOFING

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good

SCOPE OF WORK PROJECT IDENTIFICATION

City of Santa Monica Building and Safety Division Submittal Requirements Expedited Solar Photovoltaic (10 kw or Less)

Passive House II, The Design Process. Ray Rebilas, AIA - Kitchen & Associates. Harry Moody - Pennrose Properties. Mike Ferguson - S.B.

Feature Zone IECC 2009 IECC

Sealing the Envelope with SPF Insulation

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

by Jason P. Wilen, AIA, CDT, RRO testing the integrity of a roof or waterproofing membrane. But since

CRC / Chicago Center for Green Technology June 7, Chicago & IL Energy Code, Green, Garden Roofs, Energy and Drainage / Water Retention

Section 7 Waterproofing Roofing Standards

FOAMULAR Commercial Roofing

Residential Cool Roof/ Roof Insulation Measures Stakeholder Meeting #2

SECTION G RELIEF VENTS A-0

2010 National Building Code Adoption and Associated Process Changes

Building Envelope Systems Exam Learning Objectives

CONTACT INFORMATION. PV System will require a separate Electrical Permit.

INSULATED METAL PANELS INSMP2A 1LU/HSW HOUR Prepared and presented by MBCI

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1

Application Specification:

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Why Control Heat flow? How to Control Heat Flow? Thermal Performance. Modes of heat transfer: Thermal Control: Insulation & Thermal Bridges

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Demystifying Testing Standards C t B ildi F d. Common to Building Facades. John Runkle, P.E. Architectural Testing, Inc. Learning Objectives

LIFE-CYCLE ASSESSMENT (LCA) FOR SPRAY POLYURETHANE FOAMS

HPW Protocol Reference Manual

YEARS SINCE Firestone UltraPly TM TPO Membranes EXPERIENCE THE ULTIMATE IN COOL ROOFING TECHNOLOGY.

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

To order copies of this publication, call and request SPI Stock Number AY 112

Airspace R-Values. Educational Overview. Revised 12/6/2016

The Role of Control Layers in Building Enclosure Design

Lock In Energy Savings For Life

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF

Introducing TJ Insulated Structural Framing Components

IRC 2012 Key Changes

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

CSI Boston Technical Paper No. 1: Specifying Air Barriers Air Barriers

TOPCOAT System Specifications Corrugated Transite Panels

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

ACRYLIC-URETHANE ROOF COATING SYSTEMS SOPREMA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Primers: Why, When and How to Use Them In spray polyurethane and/or elastomeric coating systems

Transcription:

NRCA s 2012 SPF Manual and Technical Updates James R. Kirby, AIA Associate Executive Director, Technical Communications National Roofing Contractors Association (NRCA) SPFA Convention & Expo February 2, 2011

Today NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 A few technical topics Emerging technologies and issues (PV) Where is energy efficiency headed?

The NRCA Roofing Manual SPF (and metal) updated in 2012 Reformatted Still includes reroofing details New system configurations

The NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 Reformatted for 2012 Roof Decks Other SPF Substrates SPF Protective Surfacings Roof Accessories Roof System Configurations Roof Re covering Construction Details

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012

The NRCA Roofing Manual Series

Technical Issues and Comments White membrane over one layer insulation Vapor retarder/air retarder (barrier?) Concrete dryness NRCA proposing new dryness test See Mark Graham, AED Technical Services article from January 2012 Professional Roofing

Concrete Deck Dryness

Technical Issues and Comments TPO activity at ASTM (heat vs UV) Increasing aging requirements 2011 NRCA recommendations 60 mil minimum TPO Polyisocyanurate R value 5.0 in heating climates 5.6 in cooling climates PV temperatures, Parallel Rack PV panel fire concerns

Emerging technologies and issues NRCA is affecting building codes to ensure consistent requirements for vegetative, PV and new technologies Roof mounted PV system code compliance Fire, wind, impact, labeling NEC/NFPA 70 IFC 2012 PV temperatures, Parallel Rack PV panel fire concerns

Solar American Board for Codes and Standards

NRCA and PV

NRCA Guidelines for Roof mounted Photovoltaic System Installations This document provides NRCA s technical information for attachment and roof system enhancements.

NRCA Building Owners Guide to Roof mounted Photovoltaic Systems This document provides an overview of non technical information and should be used as a leave behind for building owners who are researching roof mounted PV systems.

Credentials CSRP Certified Solar Roofing Professional Presented by RISE www.riseprofessional.org NABCEP: Solar Photovoltaic Installer Certification

Rooftop Photovoltaic Systems: Energizing Your Business presented by February 21, 2012 Orlando

Where are we headed, energy wise?? Roofs and Walls are what we use to build. It s mostly still used, but it s going away. Give it a couple building code cycles. We are headed to Building Envelope and that includes Roof, Walls and Junctures. Junctures become important because of the need for continuity of the air barrier.

International Energy Conservation Code, 2012 Edition...is following ASHRAE 189.1 s lead to now include air barrier requirements for the entire building.

IECC 2012, Chapter 4 Commercial and residential air barriers are mandated by adoption of IECC 2012

IECC 2012, Chapter 4 C402.4.1 Air barriers Exception: not required in Climate Zones 1, 2 and 3. Table R402.4.1.1 Air Barrier and Insulation Installation Continuous sealed joints Access opening, drop down stairs shall be sealed

IECC 2012, Chapter 4 Air barrier compliance paths: Material Assembly Building

SPF and Energy Efficiency SPF: air barrier and insulation Inherently minimizes thermal bridges Used in roofs and walls, of course Roof surfacings and reflectivity For building or environment? aka, the owner versus Stephen Chu? The best way to conserve energy is to not use energy, that is, use less energy. Then, energy production is a way to reduce your energy use?

Additional NRCA SPF Documents Manual for Inspection and Maintenance of Sprayed Polyurethane Foambased Roof Systems: A Guide for Building Owners (NRCA / SPFD, 1998) Quality Control Guidelines for the Application of Sprayed Polyurethane Foam Roofing (NRCA / SPFA, 2003) A Field and Laboratory Assessment of Sprayed Polyurethane Foambased Roof Systems (R. Dupuis, 1998) Performance of Sprayed Polyurethane Foam Flashings on CD ROM (R. Dupuis, 2003)

Today NRCA Roofing Manual: Metal Panel and SPF Roof Systems 2012 A few technical topics Emerging technologies and issues (PV) Where is energy efficiency headed?

Thank you! James Kirby, AIA AED, Technical Communications National Roofing Contractors Association 10255 W. Higgins Road, Suite 600 Rosemont, IL 60018 (800) 323 9545 (847) 493 7570 jkirby@nrca.net @JamesKirbyNRCA