HIGH RESISTANCE GROUNDING THE ONLY TECHNOLOGY THAT PREVENTS ARC FLASH

Similar documents
Electrical Protection Methods and Devices SAMPLE. Learner Workbook Version 1. Training and Education Support Industry Skills Unit Meadowbank

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

Information Document Protection System Information ID# R

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

SECTION AUTOMATIC TRANSFER SWITCH

High Energy Arcing Faults (HEAF) and Their Impact on PRA for a Nuclear Power Plant Latest International Operating Experience and Research Activities

OSHA s Enforcement and Significant Changes in 2015 NFPA 70E. Presented by Doug Tellin Electrical Safety Specialists LLC.

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

REFINERY POWER OUTAGES:

Implementing and Managing Electrical Safety Programs

Grounding Principles. The need to ground! Definitions. Introduction. Grounding Codes and Standards. 2 Ph:

NZQA registered unit standard version 6 Page 1 of 5

General Electrical Safety Awareness Course: E100

Automating LV Distribution networks using sensor technologies

2018 PRICE LIST POWER*TOOLS. The Leader in Electrical Engineering Software Chosen by the top 40 Electrical Engineering firms in the world.

Service plans enhance the benefits of preventive maintenance programs

Use of Locally Fabricated or Modified Equipment. DROPS Forum July

Narayan Group. Supplying to in countries. Blue- Manufacturing units Green- Supply countries. Export business & Total Business

Electrical Safety. ESWP and NFPA 70E Electrical Safe Work Practice

Standard of Practice - Campus Electrical Distribution System

LA Engineering Academy

Hazards. Hazards. Hazards. Effects on the Body. GA Tech Electrical Safety Presentation

Facility Interconnection Requirements

Analysis of distribution system reliability and outage rates

Committee on 99 M E M O R A N D U M. NFPA Technical Committee on Electrical Systems

Friday, May 29, Update on Testing Medium Voltage Cable and Switchgear Systems

Grounding and Bonding in Boats and Marinas A Vital Link to Safety Capt. David E. Rifkin and James D. Shafer

roduct Scope: Substation

NFPA 70E Compliance: A Systems Approach

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study

CUSP Base Exams and T&D Endorsement Exam Sample Questions and Format

2017 NEC Changes for Renewable Energy Systems Session one by Christopher LaForge

Transmission Interconnection Requirements. Table of Contents

Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System

IT S ALL ABOUT PROTECTING PEOPLE

Ruby Installation Manual

HotSwap MBP Maintenance Bypass

Microturbine Energy Solutions in the CHP Industry

SECTION HEAT TRACING FOR PLUMBING PIPING

Earthing of Utility and Industrial Distribution Systems

Impacts of the Decentralized Wind Energy Resources on the Grid

Pick-up Limits to to to to to to to 6.9

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

ADDENDUM. ADDENDUM # 1 DATE: February 16, 2017

ABB AG - EPDS. FC-Protector Innovative fault current limiter for indoor and outdoor applications

UNS 5kA Arrester. Certified Test Report IEC

Overview of Common Mode Outages In Power Systems

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PowerEnergy MCC. Designed by the specialist for accidental arc fault protection!

Transient Stability Analysis of an Industrial Cogeneration System

Low Maintenance AC Powered Security Gate

COMMERCIAL & INDUSTRIAL AMI METER TESTING SUMMARY

Evaluation of CSST Gas Piping Subjected to Electrical Insult

Substation Grounding. Presented by: Bruce Kayser, PE Assisted by Danny Seele

DISTRIBUTION STATEMENT A:

Years of experience, customized for you.

Standard TPL Transmission System Planning Performance Requirements

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

METERING GUIDE PART 1 METERING GENERAL

EPS 7000 and EPS 8000

SPECIFICATIONS - DETAILED PROVISIONS Section General Electrical Requirements C O N T E N T S

The Value of Customer Reliability to the Utility

Earthing of Utility and Industrial Distribution Systems

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Delaney to Colorado River 2014

Is Your Electric Utility Prepared for the New Arc Flash Safety Regulation?

Public Utility District Number 1 of Snohomish County

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Proposals and Process 2017 National Electrical Code

Medium Voltage Service Maintenance and refurbishment

Power Quality Assessment of Large Motor Starting and Loading for the Integrated Steel-Making Cogeneration Facility

PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Electrical Safety ESWP and NFPA 70E Electrical Safe Work Practice

PDM16 & PDM32 User Manual

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM UNDER METAL ROOFING

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

Electrical Safe Work Practices Program

Nuheat Mat FLOOR HEATING SYSTEM. Installation Guide TILE, STONE & MARBLE LAMINATE & ENGINEERED WOOD

Standard Development Timeline

nicrom e l e c t r o n i c

GROUNDING AND BONDING

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer

Dissolved Gas Analysis of Transformer Oils: Effects of electric arc

Member Service Electric Wiring Guidelines

Impact Assessment in Safety Testing of Lithium-Ion

Posistor for over current protection PRG SERIES BC-E0273H PRG21BC***MM1RA SERIES

Emergency, Legally Required, and Optional Standby Power Systems

POTOMAC ELECTRIC POWER COMPANY

BULK ELECTRIC SYSTEM PLANNING CRITERIA

Avoiding the Pitfalls of Generators and Large Motors

Electrical Systems: Theory and Operation

U7242A USB3.0 Test Fixture

Since the beginning, scientists based

Novel Solutions for ESD Sensitive Devices

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

Substation Bus Design: Current Methods Compared with Field Results

Transcription:

HIGH RESISTANCE GROUNDING THE ONLY TECHNOLOGY THAT PREVENTS ARC FLASH

What is an Arc Flash? According to NFPA 70E: A dangerous condition associated with the release of energy caused by an electric arc. A hazard beyond shock and electrocution.

What does an Arc Flash Do? What does it do? It hurts people! It destroys equipment! It Results in Penalties from OSHA It Causes outages! It Affects morale!

O.2.2 Design option decisions should facilitate the ability to eliminate hazards or reduce risk by doing the following: (1)Reducing the likelihood of exposure (2) Reducing the magnitude or severity of exposure (3) Enabling achievement of an electrically safe work condition

(3) High-resistance grounding. A great majority of electrical faults are of the phase-to-ground type. Highresistance grounding will insert an impedance in the ground return path and below (at 5 kv nominal or below), leaving insufficient fault energy and thereby helping reduce the arc flash hazard level. Highresistance grounding will not affect arc flash energy for line-to-line or line-toline arcs.

Reducing the Likelihood of Exposure High Resistance Grounding IEEE Std 141-1993 Recommended Practice for Electric Power Distribution for Industrial Plants 7.2.2 (High Resistance Grounding) There is no arc flash hazard, as there is with solidly grounded systems, since the fault current is limited to approximately 5A. Another benefit of high-resistance grounded systems is the limitation of ground fault current to prevent damage to equipment. High values of ground faults on solidly grounded systems can destroy the magnetic core of rotating machinery. IEEE Std 142 1991 Recommended Practice for Grounding of Industrial and Commercial Power Systems 1.4.3 The reasons for limiting the current by resistance grounding may be one or more of the following. 1. To reduce burning and melting effects 2. To reduce mechanical stresses. 3. To reduce electric-shock hazards to personnel 4. To reduce the arc blast or flash hazard to personnel 5. To reduce the momentary line-voltage dip.. 6. To secure control of transient over-voltages while at the same time avoiding the shutdown of a faulty circuit

Likelihood of Exposure Solidly Grounding 480V Wye Source 3Ø Load AØ BØ HRG CØ I r C a c I c c I b c I a I f I = V / R Resistance of the ground fault current path is very low Ground Fault Current is very HIGH (> 1,000 A)

Reducing the Likelihood of Exposure High Resistance Grounding 480V Wye Source 3Ø Load AØ BØ HRG CØ 55.4 Ohms I r C a c I c c I b c I a I f I = V / R I = 277 / 55.4 = 5 Amps Ground Fault Current is very low

Reducing the Likelihood of Exposure High Resistance Grounding How Does HRG reduce Arc Flash? According to Industrial Power System Grounding Design Handbook - 95% of all electrical faults are phase to ground faults. By limiting the fault current to a low level, 10 amps or less, there is insufficient current for the arc to re-strike and it self-extinguishes. Source (Wye) AØ BØ N HRG CØ HRG reduces LIKELIHOOD

Reducing the Likelihood of Exposure High Resistance Grounding

(2) Arc flash relay. An arc flash relay typically uses light sensors to detect the light produced by an arc flash event. Once a certain level of light is detected the relay will issue a trip signal to an upstream overcurrent device.

Reducing the Magnitude of Exposure Arc Flash Relay Current (ka) Surface Smoke Surface Damage Burn Through An arc is developed within milli-seconds and leads to the discharge of enormous amounts of destructive energy. The energy in the arc is directly proportional to the square of the shortcircuit current and the time the arc takes to develop. Reduce the Time, Reduce the Damage, Reduce the Incident Energy. Arc damage curve showing arc current versus arc time

Reducing the Magnitude of Exposure Arc Flash Relay Protection at the Speed of Light ARC-i-TEC: Optical Sensing Technology o Sense and initiate trip in 1ms o Use current and light inputs 12 optical sensors o Simultaneously trip up to 4 breakers o ModBus Communication o BIT: Built in tester checking integrity at all times SENTRi :Optical Sensing Technology o Arc flash 1ms speed o 3 light sensors with optional pressure sensors o Simultaneously trip up to 3 breakers o ModBus Communication

Reducing the Magnitude of Exposure Arc Flash Relay Incident Energy Comparison Arc Flash Relays lower Magnitude

Who is I-Gard Eh! Founded in 1982, all manufacturing and engineering conducted in North America For over thirty years, I-Gard has been committed to quality. ISO registered since 1994, I-Gard, is currently the only resistor company in North America registered to ISO 9000:2008. This acknowledges the high level of in-house design capabilities in addition to manufacturing expertise and custom focus. All Low Voltage products are CE approved and all products are CSA certified and UL recognized and listed. Active on various UL, IEEE and NFPA committees. Industry s most extensive and advanced line of High Resistance Grounding Products.