BARN MAIN FLOOR PLAN. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By SDS-CAD Specialized Design Systems 12'-0" 3'-0" 4'-0" 1'-6" 3'-0" 1'-6" 20'-0"

Similar documents
Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

GARAGE MAIN FLOOR PLAN

14' x 24' Garage Plan

#G X With Bonus Storage By SDS-CAD Specialized Design Systems

Custom Home Design Plan #211 By SDS-CAD Specialized Design Systems

2x4 Construction 10' Ceilings 36" Brick. 28' x 30' Garage Plan. 28' x 30' Garage

Custom Home Design Plan #217 Cottage By SDS-CAD Specialized Design Systems

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

36 x 48 Barn. SDS-CAD Specialized Design Systems Copright Website 48'-0" 6'-0" 14'-9 13/16" 14'-9 13/16"

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Calculated Quantities and Details

Applying for Permits to build a new house in Linn County

Building Guide. Colorado Chapter of the International Code Council

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Administrative Changes

Residential Detached Garage Handout

Residential Building Inspections

POST FRAME BUILDING STANDARDS

Great Do you need it larger or would like to relocate windows and doors or do you need something completely different?

TYPICAL BEARING WALL FRAMING

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

The Homeowner s Building Application Checklist for Constructing a Residential Addition

RESIDENTIAL DETACHED GARAGE HANDOUT

BUILDING CODES Presented by CORUM ENGINEERING

2003 International Residential Building Code

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Detached Garages and Building Permits. 1 and 2 Family Dwellings

Attic. Bedroom 8'-11 5/8" 16'-5 5/8"

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

ABOVEGROUND HOME FALLOUT SHELTER H-12-2 / November 1983 (Supercedes H-12-2 dated June 1980)

Steps in Building a Shed

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

Table of Contents. Page Title

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

TOWN OF SOUTH KINGSTOWN REQUIREMENTS FOR BUILDING PERMITS RESIDENTIAL SINGLE FAMILY

FIGURE R502.2 FLOOR CONSTRUCTION

Formulating a Korea Industrial Standard for light-frame wood construction

RESIDENTIAL DETACHED STORAGE STRUCTURES (GARAGE)

One and Two Family Additions

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

ENGINEERED TRUSSES BY MANUFACTURER [14'-7 1/4"] SECOND FLOOR CONSTRUCTION

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Plan Check No. Checked by: An Appointment Is Required for Verification

HIGHLANDVIEW CEMETERY CHAPEL

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

1 AND 2 FAMILY DWELLING REQUIREMENTS

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

CHAPTER 5 FLOORS SECTION R501

Structural Inspection

RESIDENTIAL BUILDING PLAN REQUIREMENTS

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Inspection of New One- and Two- Family Dwellings

Plan #104. SDS-CAD Specialized Design Systems. Residential Design

10 EXTREME BASEMENT PANELS

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

Detached Residential Garage or Accessory Building ~ Includes Garage Conversion to Habitable Space ~

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Georgia State Amendments to the International Residential Code for One- and Two- Family Dwellings

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

BAND SHELLS Our versatile Band Shells perform in any community

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

The Inspection Process. Waxhaw N.C.

MID-RISE DESIGN & CONSTRUCTION

GETTING STARTED... 2 YOUR LIST OF PRODUCTS... 2 WHAT THAT LIST BECOMES... 2 PRODUCTS CREATED AS ENVISIONEER ELEMENTS... 3

Quality. 45 Years of. Construction and Over. Experience Makes a Difference. Family-Owned & Operated Since 1960

Chapter 7. Roof Framing

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

General Residential Code Requirements

Durisol: Insulated Concrete Form (ICF) Wall Forming System

The following preliminary issues may need to be addressed prior to an application for a building permit.

Light-Metal Roof Edge, Raised

FACT SHEET #2 DECK INFORMATION

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Typical Finished Basement Details

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Report: Total By Location Showing Takeoff Units $ 14, $ 85,622

Transcription:

3'-0" 12'-0" '-0" 3'-0" BWP 010 BWP BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SDSCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official. #G457a 12 x 20 x 8 Gentleman Bunkhouse Shed By 20'-0" 3'-0" 4'-0" 1'-" 3'-0" 1'-" 4'-0" 3'-0" 308 4' WIDE SHELF 7' HIGH 010 3'-0" '-0" 3'-0" 12'-0" 3'-0" 4'-0" '-0" 4'-0" 3'-0" 20'-0" Page 1 Page 2 Page 3 Page 4 Page 5 Page Title Main Floor Plan Elevation Views Foundation Plan & Pictorials Framing and Details Detail Page Materials List 30 year charcoal architectural shingles and cedar clapboard siding over structural panel. Nailing schedule is " on ends 12" on centers d nails. Framing is 2" x " on 1" centers. 8' ceiling height. SCALE 1/4"=1' BARN MAIN FLOOR PLAN 1

10/12 PITCH TRUSS RO Ridge Vent and Ridge Caps REAR ELEVATION Keystone trim over windows and at peak not shown see sample photo LEFT ELEVATION 30 Year Charcoal Architectural Asphalt Shingles Cedar Clapboard Siding 72 x 15 Transom Window Above Wall Plates 7" Overhang all 4 walls Pine Trim All Around 8'-0" 5'-8" 13'-8" FC Cedar Clapboard Siding Over Structural Panel all 4 Walls 7'-10" Tall 2 x Walls FF 8" 12 x 20 Slab Foundation SCALE 1/4"=1' FRONT ELEVATION RIGHT ELEVATION 2

12x20 Colonial Gentleman's Barn Design Notes 1) Built on 8" concrete slab 12'x20', with "J" anchors, 2) 2x Pressure treated bottom wall plates, 3) 2x kiln dried wall studs 1" on center, wall height 7'.10", 4) 10/12 Roof trusses,1" on center, 5) One, 72"x7" Door opening ( gable end wall for double rolling pine doors ), ) One, 72"W x 15"H, Transom window opening ( above top wall plates, over door, for true divided light transom ), 7) Four, 48"W x 24"H window openings ( two on each load bearing wall for tilt in sash windows ), 8) 7" roof overhand all four walls 9) Cedar Clapboard all four walls, 10) Keystone trim over windows and at roof peak, 11) Reproduced of old fashioned style antique horse shoe rolling / sliding door hardware, 12) 30yr Architectural roof shingles ( Charcoal ) 13) Ridge Vent and ridge caps, 14) Pine trim all around, 15) Interior storage loft, 4' x 12', ( across back wall, 7' off the floor ) Sample Keystone Trim Over Window Sample Sliding Door Hardware 8" Slab Foundation 12'-0" 20'-0" FOUNDATION PLAN SCALE 1/4"=1' PICTORIAL VIEW Concrete: 1. All slabs are to be min 8" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 301-, Type II cement, 2500 psi at 28 days, 5" maximum slump. 3. If required reinforcing to be ASTM A15-Bars with Fy=0 ksi lamp 30 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 1500 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-307 embedded 7" minimum into concrete or masonry grout. 3

010 Framing views are for basic reference only Optional 4' Wide 7' High Shelf 010 Optional 10/12 Pitch Scizzor Engineered Truss For Larger Storage General framing: (Douglas Fir) 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to 4'-0" Span 2-2x4's 4' + to '-0" Span 2-2x's ' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to 12'-0" Span 2-2x12's or as noted on plan 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 12 wall bracing with 3-1d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of 7/1 inch. 3. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs. 5. Exterior wall framing to be 2"x4" studs at 1" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 1" o.c. with double top plate.. Shear wall to be 7/1" Sheathing, see detail. 7. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. Roof Framing: 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details. 3. For spans and dimensions refer to floor plans. 4. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 5. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses.. Minimum header sizes shall be according to the header size table unless otherwise noted. 7. Basis of design roof live/snow load of 40 psf, and roof dead load of 15 psf. 8. Plywood roof decking to be Min ½" thick, 24/0, CDX or 5/8 wafer. 9. 4/12 Pitch Engineered Attic Scissor Trusses WALL FRAMING SECTIONS SCALE 1/4"=1' 4

SINGLE POUR CORNER INSTALLATION HPAHD straps for all () Alternate Braced Wall Panels See additional detail for all (BWP) Braced Wall Panels TYPICAL ALTERNATE BRACED WALL PANEL () GRADE 2 % MIN. SLOPE " MIN. THICKNESS CONCRETE WALL CORNER DISTANCE FROM EDGE STRAP TO CORNER Simpson Strong-Tie HPAHD 8" o o @32" MAX. SPACING. BOLTS SHALL BE EMBEDDED 7" MIN. 5" CONC. SLAB Footing and concrete wall option NOTE: TYPICAL DETAILS FOR CONSTRUCTION TO MEET BUILDING REQUIREMENTS. BARN TO BE BUILT AS PER LOCAL CODE REQUIREMENTS 4" COMPACTED GRAVEL ASPHALT SHINGLES OVER 30# FELT 5/8" SHEATHING SIMPSON H1 TRUSS CLIP CDX PLYWOOD SHEAR WALL INSTALLED W/ LONG DIMENSION ACROSS STUDS. STAGGER VERTICAL JOINTS PANEL SHEATHING USED AS CORNER BRACING W/ LONG DIMENSION PARALLEL TO STUDS SIDING MATERIAL STRUCTURAL PANEL CAN ACT AS SIDING IF EXTERIOR GRADE PRE-ENGINEERED TRUSSES @ 24" O.C. TYPICAL BRACED WALL PANEL (BWP) Vaulted Truss Not Shown LEAVE 1/4" GAP @ EDGES & 1/8" GAP @ ENDS UNLESS OTHERWISE REC- OMMENDED BY MANUFACTURER WALL FRAMING 10d NAILS @ " O.C. AT EDGES & SEAMS AND 10d NAILS @ 12" O.C. IN FIELD U.N.O. ON SHEAR WALL SCHEDULE 12 10 7" 1/2" ANCHOR BOLT 32" O.C. 1 x FASCIA 2 x STUD @ 1" O.C. 5" CONCRETE SLAB 7/1" MIN STRUCTURAL SHEATHING VAPOR BARRIER 4" GRAVEL BASE " MIN. GRADE 8" X 20" CONCRETE THICKENED EDGE SLAB MINIMUM 2 x 4 Bottom Plate 2 x TREATED MUDSILL 1/2" x 10" ANCHOR BOLT EMBEDDED 7" INTO CONC. 5" CONC. SLAB OVER 4" GRAVEL SLOPE TO OUTSIDE Monolithic slab foundation option BARN TYPICAL SECTION DETAILS 5

Total: REVISIONS Verify Before Construction General GN1 1 9 high wall Siding- 23 0 ft GN2 1 98 1/4 high wall Siding- 39 0 ft GN3 1 heated floor area 240.00 0.00 sq ft GN4 1 heated roof area 20.00 0.00 sq ft GN5 2 57 1/4 high wall Siding- 21 0 ft Foundation FO1 1 240 sq ft concrete slab 2.9 0.00 cu yd FO2 1 240 sq ft steel mesh for slab 240.00 0.00 sq ft FO3 1 1/2x" foam sill seal 4 0 ft FO4 1 foundation bolts 12 0 FO5 1 20x"h concrete footing 1.77 0.00 cu yd FO 1 no. 4 rebar (footing) 119 0 ft Subfloor SF1 1 2x"-22' ceiling joists - lumber 1 0 Framing F1 1 2x11-1ft+ header - lumber 25 0 ft F2 1 2x-1ft+ fir plate 228 0 ft F3 1 2x-1ft+ fir stud stock 427 0 ft F4 1 2x7-1ft+ header - lumber 41 0 ft F5 1 2x"-91 1/2" fir stud 29 0 F 1 2x"-4 3/4" fir stud 3 0 F7 2 2x-1ft+ fir stud stock 54 0 ft F8 2 2x-1ft+ fir plate 4 0 ft Siding S1 1 11 1/2" wide Siding Wood Pine 507 0 ft S2 1 4'x8'x5/8" Sheet Plywood-hrz 1 0 S3 1 house wrap 508.00 0.00 sq ft S4 2 11 1/2" wide Siding Wood Pine 2 0 ft S5 2 4'x8'x5/8" Sheet Plywood-hrz 2 0 Ext Trim EX1 0 4" thick - concrete grey 5.91 0.00 cu yd EX2 1 1x4-1ft+ exterior sill - framing fir stock std. 32 0 ft EX3 1 1x4-1ft+ ext. window casing - framing fir stock 55 0 ft EX4 1 1x7-3" door threshold 1 0 EX5 1 1x4-1ft+ ext. door casing 17 0 ft EX 1 7 in ext. door jamb 17 0 ft EX7 1 1x in (2) corner board - framing fir stock std. + 32 0 ft Roofing R1 1 155" roof truss 11 0 R2 1 2x8"-1'+ ridge board - lumber 21 0 ft R3 1 2x"-22' rafters - lumber 2 0 R4 1 2x"-10' rafters - lumber 4 0 R5 1 2x4"-1'+ rafters - lumber 19 0 ft R 1 ridge vent 41 0 ft R7 1 ridge cap 41 0 ft R8 1 Roofing Dimensional Comp. 05.00 0.00 sq ft R9 1 4x8' sheets roof sheathing 19 0 R10 1 2x" gable fascia 58 0 ft R11 1 2x" eave fascia 83 0 ft R12 1 metal drip edge 141 0 ft Insulation IN1 1 12x1x48" batts floor insulation 45 0 IN2 1 12x1x48" batts roof insulation 48 0 Wall Brd WB1 1 4'x8'x1/2" Sheet Sheetrock 1 0 WB2 2 4'x8'x1/2" Sheet Sheetrock 2 0 Windows W1 1 72x12 fixed glass 2 0 W2 1 48x24 hopper 4 0 Doors D1 1 3x80x1 3/4R ext. -Panel 1 0 D2 1 handle: Lever (decorative) 1 0 D3 1 handle: Exterior Handle (ext.) 1 0 D4 1 lock: Dead Bolt (interior) 1 0 D5 1 lock: Dead Bolt (exterior) 1 0 D 1 hinge: hidden 3 0 Int Trim T1 1 1x4-1ft+ window apron 32 0 ft T2 1 1x4-1ft+ sill 32 0 ft T3 1 1x4-1ft+ interior casing 72 0 ft Electrical E1 1 wall mount Duplex 7 0 E2 1 wall mount Caged Lantern 2 0 E3 1 ceiling mount Half Dome Light - lighting grey 2 0 Computer Generated Materials List From the 3D CAD Model