Comparison of BS 5308, PAS 5308 and BS EN

Similar documents
Construction guideline

Instrumentation Cables

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

7. EXTENSION LEADS AND COMPENSATING CABLE

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

INTERNATIONAL STANDARD

Armoured Instrumentation Cables to BS7917

INTERNATIONAL STANDARD

U.V resistance UL Sunlight Resistance. Flame retardant IEC

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0


*** Supercedes: BECO E and COM , , & ***

Technical Specification for Plastic-Insulated Low Voltage Cables

The Company by Peter Bröckskes sen. an independent, middle sized company

NPS/001/007 Technical Specification for Overhead Line Conductors

P.V.C. INSULATED UNARMOURED COPPER CABLES

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

NPS/002/023 Technical Specification for 132kV Power Cables.

Cables for Railway Signalling Applications General Requirements

Cable Jointing Manual. Jointing Procedures. Module 18. Concentric Cables

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

SECTION WIRES AND CABLES

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

SECTION INSULATED WIRE AND CABLE

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

Una e mpre sa Vi akab l e GLOSSARY.

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Single core conductor BETAtherm 145

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

TS 804 CABLES TABLE OF CONTENTS TRAFFIC SIGNAL EQUIPMENT POLE WIRING DIAGRAM LOCATIONS WITH CENTRE MEDIANS


ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

NPS/002/001 Technical Specification for Earthing Materials

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

PART 7 Technical Specification for Overhead and Underground Service Connection works for the Year

Cable solutions for Automation & Drives

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

Cables for Drag Chains

EI INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

catalog Copper Wires

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

CONTENTS INSTRUCTIONS. UK POWER NETWORKS LV JOINTING MANUAL I Version Section Index I Page 1

A-5 CABLE TECHNOLOGIES

Proven Capabilities. Features and Benefits. Watlow provides:

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TECHNICAL SPECIFICATIONS

History of Cable Systems HISTORICAL OVERVIEW OF MEDIUM & HIGH VOLTAGE CABLES. Nigel Hampton

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Introduction. Railway Cables

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

BS 476: Part 6: Method Of Test For Fire Propagation For Products. WF Additional Report Number: Date: 18 th February 2008.

XLPE CABLE (11KV - Aluminium)

Flat polyvinyl chloride sheathed flexible cables

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

«CABLE T 92» WORKSHOP BALI, INDONESIA JUNE, 1992 POWER CABLES IN TROPICAL ENVIRONMENTS : SYNTHESIS. By L. DESCHAMPS SEE / EDF (France)

ABOUT US. Unit II: Halol, Gujarat. (Semi conductive compounds) (HFFR Halogen Free Flame Retardant)

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

1. General regulations

THERMOCOUPLES and THERMORESISTANCES - Temperature measurement sensors for industrial use Figure 1: Standard Thermocouples

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

Standing Seam Systems. NBS Specification. KingZip SF Standing Seam Roofing System

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

Version: 1.1 Date of Issue: March 2017 Page: 1 of 23

Thermocouple Accuracies Tolerance classes for thermocouples to IEC : 1982.

High-Tech Copper Products for Solar Systems

Fibre optic cables CTC LSZH 1,2kN

15 kv EPR Insulated, Jacketed, URD Cable

Serv. Low-Voltage Cable Insulated Conductors for Overhead and Underground Distribution

ELE-3COP-256 Title Hand Cable Laying.

SECTION HVAC INSULATION

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

PASSIVE FIRE PROTECTION PRODUCTS

CHAPTER 11 CONDUITS AND FITTINGS

Type II Environmental Declaration according ISO 14021:2001/A1:2011


COPPER ALUMINUM PARTS AND SUB-ASSEMBLIES

Transcription:

Comparison of BS 5308, PAS 5308 and BS EN 50288

Scope BS 5308 Part 1: 1986- Instrumentation Cables Part 1. Specification for Polyethylene Insulated Cables (withdraw, superseded by BS EN 50288-7) BS 5308 Part 2: 1986- Instrumentation Cables Part 2. Specification for PVC Insulated Cables (withdraw, superseded by BS EN 50288-7) PAS 5308-1:2009- Control and Instrumentation Cables Part 1: Specification for Polyethylene Insulated Cables (current, based on BS 5308-1:1986, has been developed to incorporate additional aspects not covered in the European standard for control and instrumentation cables, BS EN 50288-7) PAS 5308-2:2009- Control and Instrumentation Cables Part 2: Specification for PVC Insulated Cables (current, based on BS 5308-2:1986, has been developed to incorporate additional aspects not covered in the European standard for control and instrumentation cables, BS EN 50288-7) BS EN 50288-7:2005- Multi-element Metallic Cables Used in Analogue and Digital Communication and Control- Part 7: Sectional Specification for Instrumentation and Control Cables (Current)

Conductor solid (BS 6360 class Kind of 1) conductor stranded (BS 6360 class 2 or class 5) stranded (BS 6360 class 2 or class 5) solid (BS EN 60228 class 1) stranded (BS EN 60228 class 2 or class 5) stranded (BS EN 60228 class 2 or class 5) solid (HD383 class 1) stranded (HD383 class 2) flexible (HD383 class 5) (except for thermocouple extension and compensating cables, with conductors as described in Annex D) plain annealed Copper plain annealed copper copper plain annealed copper plain annealed copper plain annealed copper metal coated copper Size 0.5mm² 1.0mm² 1.5mm² 0.5mm² 0.75mm² 1.5 mm² 0.5mm² 1.0mm² 1.5mm² 2.5 mm² 0.5mm² 0.75mm² 1.5mm² 2.5 mm² 0.5mm² 0.75mm² 1.0mm² 1.5mm² 2.5 mm²

Insulation Materials PE type 03 acc. to BS 6234 PVC type TI1 acc. to BS 6746 thermoplastic PE to BS EN 50290-2-23:2002 grade L/MD XLPE to BS EN 50290-2-29. PVC to BS EN 50290-2- 21:2002, grade TI51. Range 300/500 V 300/500 V 300/500 V 300/500 V PVC acc. to EN 50290-2 21 PE acc. to EN 50290-2 23 PP acc. to EN 50290-2 25 Halogen free flame retardant compound acc. to EN 50290-2 26 XLPE acc. to EN 50290-2 29 temp. range from 70 C up to 105 C 90V 300V 500V Thickness Caledonian BS 5308 cable Caledonian BS 5308 cable Caledonian PAS 5308 cable Caledonian PAS 5308 cable Caledonian EN 50288-7 cable (LSZH Sheath) Caledonian EN 50288-7 cable (PVC Sheath)

Cable elements Kind of elements pair (twisted) quad (around a single dummy; only for 2 pair cables without individual pair screens) pair (twisted) quad (around a central dummy; only for 2 pair cables without individual pair screens) pair (twisted) quad (around a single dummy; only for 2 pair cables without individual pair screens) core pair (twisted) quad (around a single dummy; only for 2 pair cables without individual pair screens) core pair (twisted) triple (twisted) quad (twisted) Twisting of elements reverse layer or reciprocating lay technique 100mm reverse layer or reciprocating lay technique 100mm reverse layer or reciprocating lay technique 100mm reverse layer or reciprocating lay technique 100mm lay length 100mm( 1.5mm2) and 150mm(2.5mm2)

Individual pair screens laminated tape aluminium/pet aluminium thickness 8 µm PET thickness 10 µm (metallic side down, in contact with drain wire + wrapping consisting of one layer tape (50% overlap) or two layers of tape ( 23µm) (each 25% overlap).) laminated tape laminated tape aluminium/pet aluminium/pet aluminium thickness aluminium thickness 8 µm PET thickness 8 µm PET 10 µm thickness 10 µm (metallic side down, in (metallic side down, contact with drain wire in contact with drain + wrapping consisting wire + wrapping of one layer tape consisting of one (50% overlap) or two layer tape (50% layers of tape overlap) or two ( 23µm) (each 25% layers of tape overlap).) ( 23µm) (each 25% overlap).) laminated tape aluminium/pet aluminium thickness 8 µm PET thickness 10 µm (metallic side down, in contact with drain wire + wrapping consisting of one layer tape (50% overlap) or two layers of tape ( 23µm) (each 25% overlap).) a)a plain or coated metal braid with a minimum filling factor of 0.6 when calculated in accordance with Annex B b)a combination of a foil, and a plain or coated metal braid with a minimum filling factor of 0.3 when calculated in accordance with Annex B, optional drain wire c)a foil applied with a minimum overlap of 20% and drain wire Drain wire solid or stranded, solid or stranded, solid or stranded, solid or stranded, tinned annealed tinned annealed tinned annealed tinned annealed copper cross section copper cross section not defined copper cross section copper cross section 0.5mm² 0.5mm² 0.5mm² 0.5mm²

Colour code Pairs Colour code Colour code Colour code Colour code Unless otherwise specified e.g. by means of numbered cores or tapes, the coding for Triples Not defined Not defined Not defined Not defined Quads Not defined (exception: 2 pair is a 1 quad construction) Not defined (exception: 2 pair is a 1 quad construction) Not defined (exception: 2 pair is a 1 quad construction) Not defined (exception: 2 pair is a 1 quad construction) identification shall be as given in IEC 60189-2 or EN 60708, as appropriate. The colours shall meet the requirements of 4.4 of EN 50288-1 Remark differentiation of the pairs is defined through different colour codes for each pair; alternatively numbered PET foil around pairs differentiation of the pairs is defined through different colour codes for each pair; alternatively numbered PET foil around pairs differentiation of the pairs is defined through different colour codes for each pair; alternatively numbered PET foil around pairs differentiation of the pairs is defined through different colour codes for each pair; alternatively numbered PET foil around pairs

Overall screen Collective screen laminated tape aluminium/pet aluminium thickness 8 µm PET thickness 10 µm + drain wire consisting of solid or stranded, tinned annealed copper cross section 0.5mm² Wrapping layer of tape under collective screen laminated tape aluminium/pet laminated tape aluminium/pet aluminium thickness aluminium thickness 8 8 µm 8 µm plain or coated metal braid with µm PET thickness 10 µm PET thickness 10 µm a minimum filling factor of 0.3 PET thickness 10 µm + drain wire + drain wire (optional) when calculated in accordance + drain wire consisting consisting of solid or consisting of solid or with Annex B,optional drain wire of solid or stranded, stranded, tinned stranded, tinned c)a foil applied with a minimum tinned annealed copper annealed copper cross annealed copper cross overlap of 20% and drain wire cross section 0.5mm² section 0.5mm² section 0.5mm² Wrapping layer of tape Wrapping layer of tape under collective screen Wrapping layer of tape under collective screen laminated tape aluminium/pet aluminium thickness under collective screen a)a plain or coated metal braid with a minimum filling factor of 0.6 when calculated in accordance with Annex B b)a combination of a foil, and a screening over the cable core may also be in the form of a laminated sheath Metal braid not defined not defined not defined not defined

Inner sheath Bedding layer - - - - extruded bedding of type 2C or type 03 black PE compound in accordance with BS 6234(TYPE 2) extruded bedding of type TM1 or type 6 black PVC compound in accordance with BS 6746(TYPE 3) extruded bedding of type TM1 black PVC compound in accordance with BS 6746 (TYPE 2) extruded bedding of a PE compound conforming to BS EN 50290-2-24:2002, grade LD(TYPE 2) extruded bedding of a PVC compound conforming to BS EN 50290-2-22:2002, grade TM51(TYPE 3) extruded bedding of a PVC compound conforming to BS EN 50290-2- 22:2002, grade TM51 (TYPE 2) a)pvc to EN 50290-2-22 b)polyethylene to EN 50290-2-24 c)halogen free flame retardant compound to EN 50290-2-27 between a lead sheath and a metallic protection. This layer may be extruded or comprise helically applied tapes or tapes

Metallic protection/armouring Round steel wire SWA galvanized steel wire armour 0.9, 1.25, 1.6, 2.0' 2.5mm galvanized steel wire armour 0.9, 1.25, 1.6, 2.0, 2.5mm galvanized steel wire armour 0.9, 1.25, 1.6, 2.0' 2.5mm galvanized steel wire armour 0.9, 1.25, 1.6, 2.0, 2.5mm SWA Min. thickness of wires 0.8 mm Flat steel wires with counter helix not defined not defined not defined not defined Only applied to cables where overall diameter under armour > 15 mm Min. thickness of wires 0.8 mm Steel or brass tape not defined not defined not defined not defined min. thickness of tape; brass: 0.075 mm steel: 0.20 mm single or double layer Metal braid not defined not defined not defined not defined galvanised steel wires ( Q ) wire diameter 0.3 mm filling factor 0.57 mm

Outer sheath Material extruded bedding of type TM1 or type 6 black PVC compound in accordance with BS 6746(TYPE 1) extruded oversheath of type TM1 PVC compound in accordance with BS 6746(TYPE 2/TYPE 3) extruded bedding of type TM1 or type 6 black PVC compound in accordance with BS 6746(TYPE 1) extruded oversheath of type TM1 PVC compound in accordance with BS 6746(TYPE 2) extruded sheath of a PVC compound conforming to BS EN 50290-2- 22:2002, grade TM51 extruded sheath of a PVC compound conforming to BS EN 50290-2- 22:2002, grade TM51 PVC (EN 50290-2-22) Polyethylene (EN 50290-2- 24) Halogen free flame retardant compound LSZH (EN 50290-2-27) Thickness refer standard refer standard refer standard refer standard Calculated acc. to formular: without metallic protection SRT = 0.04 x D +0.7 (min. 0.8 mm) with metallic protection SRT = 0.028 x D +1.1 (min 1.3 mm) D = Diameter under outer sheath

Environmental and other protection Moisture barriers not defined not defined not defined not defined a)water swellable tapes b)water swellable non-toxic powder c)filling compound d)laminated sheath, consisting of a longitudinal overlapped metallic foil,bonded within the overlapping and to the inner surface of an extruded sheath. The foil shall be one or both sides plastic coated, but in the case of only one side being coated a tinned copper drain wire shall be applied in direct contact with the metallic surface of the foil. The thickness of the metallic part of the foil shall be atleast 0.15mm e)combinations of these four methods

Chemical and / or environmental protection (one of the follow methods) Multilayer sheath not defined not defined not defined not defined Multilayer sheath Laminated aluminium (Al) foil with an extruded layer of HDPE + layer of Polyamide (PA) Thickness of Al 15 µm Thickness of PA 0.3 mm (thickness at any point) Lead sheath Part 1 type 3 cables extruded sheath of lead alloy conforming to BS 801 none Part 1 type 3 cables extruded sheath of lead alloy conforming to BS EN 50307 none M (Lead sheath) complying with EN 50307 can be apllied The thickness is calculated in acc. to the diameter (D) underneath; Formular: LRT = 0.03 x D+0.7mm with a thickness at any point min. 0.66 mm