OPACI-COAT Water-base Silicone Glass Coating

Similar documents
Section Glass Wall Cladding

S P A N D R E L SPECIFICATION GUIDE

SECTION SPECIAL FUNCTION GLAZING

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

Repair Maintenance Hangar Phase II August 2010

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

ICD High Performance Coatings. Contractor Manual

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Spandrel Glass Types and Recommendations

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

First Class Building Products, Inc.

Guideline Specifications

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

Note: Any verbiage written in red needs to be specified. All other options should be deleted

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION WOOD WINDOWS (ANDERSEN 200 SERIES GLIDING AND PICTURE WINDOWS)

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

A. Section includes glazing for the following products and applications and of the following types:

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

GLASS DESIGN GUIDELINES

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

GENERAL REVELATION FOR SHIPPING CONTAINERS

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION STILE AND RAIL WOOD DOORS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

ADDENDUM #1. INVITATION FOR BIDS: NT North Macon Park Renovation of the Building

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

CERAMIC FRIT SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

SL150 Guide Specification

SPECIFICATION GUIDELINE

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SPECIFICATIONS: Architectural Aluminum Railings

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

A typical structural glazing system is composed of a number of essential components:

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

Section Sliding Aluminum Framed Glass Doors (2500 Model Specifications)

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

CS-100 Guide Specifications

SECTION FOOD DISPENSING EQUIPMENT- SNEEZE GUARDS AND PARTITION POSTS

SECTION ALUMINUM STORM WINDOWS

SPECIFICATION GUIDELINE

SECTION CONCRETE PAVING SLABS SET IN MORTAR

OPACI-COAT 300 SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

TILE TILE


SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

Corium Brick Rainscreen System Specifications

SECTION ALUMINUM WINDOWS

SECTION EXPANSION CONTROL

Guide Specifications Section

LUX Specifications. Section S - Preformed Steel Siding

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

SECTION EXPANSION CONTROL

SECTION DECORATIVE METAL AND GLASS RAILING

RAY-CORE Structural Insulated Roof and Wall Panels

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Guide Specifications Section

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

SECTION GLASS AND GLAZING PART 1 - GENERAL

WESTECK WINDOWS and DOORS

1.3 REFERENCE STANDARDS

Advance NG (6mm) Technical Specification Sheet

A. Submit product data sheets and literature verifying physical properties of materials.

Guide Specifications Section

General Glazing Guidelines

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

Section PANEL SIGNAGE

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

BITUMEN-SET PRECAST CONCRETE PAVING SLABS

Page 1 of 5

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

PPG Guide Specification

Transcription:

www.icdcoatings.com 1.360.546.2286 DIVISION 08 00 00 SECTION 08 00 00 GLASS WALL CLADDING Please note that this specification is not complete until reviewed by a specification professional. Certain parts may need to be deleted or added for this to be complete. This specification guide only speaks to parts pertaining to the spandrel portion of monolithic glazing and insulated glass unit glazing and it s pertinence to spandrel glass. Important parts pertaining to the overall glass and glazing portion of a specification have been omitted, please ensure your specification is complete. This is a guide only. As well, much of this specification contains information or will need to have information added in respect to the glass fabricator and must be checked for accuracy in respect to the manufacture of the glass and not just the opacifier. PART 1 - GENERAL 1.01 DESCRIPTION/SUMMARY A. General Information 1. Section includes: OPACI-COAT-300 glass glazing for wall cladding applications. 2. Other contract documents and requirements of Division 1 & 2 apply to work of this Section. B. Work Included Include all labor, materials, equipment, transportation and services to complete installation of silicone opacifying coated WALL CLADDING GLASS as shown on the drawings and herein specified. 1. Related Sections: a. Sealants - Section 08 44 00 b. Glazing - Section 08 00 00 c. Gypsum Wall Board - Section 09 21 00 d. Painting - Section 09 00 00. 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 1

OPACI-COAT-300 Glass Wall Cladding 1.02 REFERENCES A. United States 1. ASTM C162 - Standard Terminology of Glass and Glass Products 2. ASTM C1036 - Standard Specification for Flat Glass 3. ASTM C1048 - Standard Specification for Heat-Treated Flat Glass -- Kind HS, Kind FT, Coated and Uncoated Glass 4. CPSC 16 CFR 1201 - Safety Standard for Architectural Glazing Materials B. Canada 1. CAN/CGSB - 12.1-M Tempered or Laminated Safety Glass 2. CAN/CGSB - 12.2-M Flat Clear Sheet Glass 3. CAN/CGSB - 12.3-M Flat Clear Flat Glass C. United States & Canada 1.03 DEFINITIONS 4. GANA Glazing Manual A. Monolithic glass & coating orientation 1. Surface 1:.Exterior surface (surface facing room) 2. Surface 2:.Interior surface (surface facing wall) B. OPACI-COAT-300 wall cladding glass: Glass that has been rendered opaque with a water-based silicone elastomeric coating. 1.04 DESIGN REQUIREMENTS Items in this part of the specification will depend on building requirements such as: wind load, thermal movements, impact loads, failures, as well as possible tempered glass breakage limits. Please ensure this section is completed by a design professional. 1.05 SUBMITTALS A. Submit 12 x12 (300mm x 300mm) samples of each glass type indicated, with each color required for the wall cladding glass. Architect or designer approval must be sought before manufacture. B. Submit opacifier manufacturer s Product Data Sheet and glazing instructions. C. Glazing contractor shall obtain compatibility reports from component manufacturers (such as opacifier, sealants, gaskets, setting blocks, etc), ensuring that the glazing materials were tested for compatibility. Please note that other submittal requirements may be added, such as reports and assurances on: security glazing, safety glazing, IGU requirements and testing. 1.06 QUALITY ASSURANCE A. Comply with published recommendations of glass product manufacturers and organizations below, except where more stringent requirements are indicated. Refer to these publications for glazing terms not otherwise defined in this section or referenced standards. 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 2

1. GANA Publications Please note that other QA statements may need to be added that would pertain to the glass fabricator, such as marking of tempered products, safety glazing compliance, etc. 1.07 DELIVERY, STORAGE, AND HANDLING A. Comply with manufacturer s instruction for receiving, handling, storing and protecting glass & glazing materials. B. Delivery: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. C. Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperatures and humidity conditions recommended by the manufacturer. D. Exercise exceptional care to prevent edge damage to glass, and damage/deterioration to coating on glass. 1.08 PROJECT/SITE CONDITIONS 1.09 WARRANTY PART 2 D. The opacifying coating will not lose adhesion, flake, peel, chip or develop any.noticeable color change for a period of ten (10) years from date of installation. Please note that warranty statements need to be added for the glass product created at the fabricator level, such as the insulated glass. PRODUCTS 2.01 MANUFACTURERS A. Manufacturer is used in this section to refer to a firm that produces primary glass.or fabricated glass as defined in the referenced standards. 2.02 MATERIALS A. Monolithic OPACI-COAT-300 wall cladding glass. 1. The OPACI-COAT-300 opacifying coating shall have a minimum thickness of 6.5 mils dry (0.17mm). 2. Only Approved Factory Fabricators (AFF) are allowed to produce the OPACI-COAT-300 wall cladding glass, as AFF glass fabricators are certified and trained by ICD in the application and manufacture of the wall cladding glass. 3. For a list of Approved Factory Fabricators, please contact ICD at 1.360.546.2286 or www.icdcoatings.com. 4. Approved manufacturers of OPACI-COAT-300 : B. Glass type: C. Glass tint: a. ICD High Performance Coatings, 13911 NW 3rd CT, Vancouver, WA 98685, USA. 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 3

OPACI-COAT-300 Glass Wall Cladding D. Reflective Coating: E. Nominal thickness: F. Glass strength (Heat-Strengthened or Tempered): G. Spandrel Coating Orientation: Surface #2 H. OPACI-COAT-300 Color Name and Number: I. US & Canadian Requirements: 3.01 EXAMINATION A. Site Verification and Conditions 3.02. PREPARATION 1. Verify that site conditions are acceptable for installation of the glass. 2. Verify openings for glazing are correctly sized and within tolerances. 3. Verify that the minimum required face and edge clearances are being followed. 4. Do not proceed with glazing until unsatisfactory conditions have been corrected. A. Protection 1. Handle and store product according to GANA Glazing Manual recommendations as well as the recommendations of the manufacturer and fabricator. B. Surface Preparation 3.03 INSTALLATION 1. Clean and prepare glazing channels and other framing members to receive glass. A. Cut all glazing sheets square, assure edges are smooth and free of chips and hairline cracks. B. Cut glazing sheets to field measurements, allow for expansion clearances as recommended by manufacturer of materials. C. Follow all manufacturer s glazing recommendations as well as GANA Glazing Manual recommendations. D. On OPACI-COAT-300 coating, a non-acidic sealant should be used Sealants or bonding materials with acidic or hydrocarbon-based thinners cannot be used. Gaskets and setting blocks shall be made of silicone. See ICD High Performance Coatings for a complete list of approved sealants and glazing material. E. Depending upon the area of use, additional backup material may be required. Backing and reinforcing types of materials may be gypsum, plywood or safety films. F. Metal T or L section shall be securely fastened to wall material and capable of supporting the weight of the glazing sheet. 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 4

G. Surface to receive glass panels shall be smooth and thoroughly dry. A primer may be required. H. See attached drawings for application methods of sealant, different methods apply for size of glass as well as height of glass wall. 3.04. CLEANING A. Clean excess sealant or compound from glass and framing members immediately after application, using solvents or cleaners recommended by manufacturers. B. Glass to be cleaned according to: 1. GANA Glass Informational Bulletin GANA 01-0300 - Proper Procedures for Cleaning Architectural Glass Products. 2. GANA Glass Informational Bulletin GANA TD-02-0402 - Heat-Treated Glass Surfaces Are Different. C. Do not use scrapers or other metal tools to clean glass. D. If OPACI-COAT-300 becomes damaged by visible scratches, field repairs can be made to the coating, please contact ICD High Performance Coatings for specific instructions. **The following diagrams and drawings are meant to guide and aide in the use of ICD products and in no way should be considered complete or to code..please consult the GANA Glazing manual as well as any local and federal building codes and practices. 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 5

OPACI-COAT-300 Glass Wall Cladding 84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 6

84.W OC300 Suggested Architectural Specifications Wall Cladding.docx Page 7