SECTION RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS

Similar documents
Series - 1

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

Series - 1

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

C. Section Metal Fabrications: Steel frame and supports.

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

SECTION ACCORDION FOLDING PARTITIONS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

by Rollfab Metal Products

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

SECTION COMPOSITE EXTERIOR SHUTTERS AND ACCESSORIES

SECTION PRE-ENGINEERED BUILDING INSULATION

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Corium Brick Rainscreen System Specifications

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION HEAVY GLASS TOP HUNG SLIDING BI-FOLD DOOR SYSTEMS

SECTION SLIDING PATIO DOORS. Display hidden notes to specifier by using Tools/Options/View/Hidden Text

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

SECTION TURBINE VENTILATORS

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

A. Access doors and frames are part of an access door and frame allowance.

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION ALUMINUM STORM WINDOWS

SECTION WATERTIGHT FLOOD PLANKS. A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

SECTION STILE AND RAIL WOOD DOORS

University Apartments on Brooklyn PROJECT MANUAL

SECTION ALUMINUM WINDOWS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

Guideline Specifications

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

ALL-ALUMINUM DOOR & WINDOW FRAMING

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SECTION GUTTERS AND DOWNSPOUTS

Series 3000 Pocket Doors

American Metal Specialties, Inc.

SECTION LIGHT DUTY SLIDING AND STACKING GLASS DOOR SYSTEMS

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

SECTION EXTERIOR GRILLS AND SCREENS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

AMBICO Limited Section and RFI\EMI SHEILDED STEEL DOOR AND FRAME ASSEMBLIES Page 1

Sliding Patio Doors Brickmould Vinyl

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION EXPANSION CONTROL

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION IMPACT RESISTANT WALL PROTECTION

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Repair Maintenance Hangar Phase II August 2010

SECTION EXPANSION CONTROL

Section SECTIONAL INSULATED STEEL DOORS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SECTION DECORATIVE METAL FENCES AND GATES

SECTION Fiberglass Entry Doors (Pre-Hung)

Specifications for FL-100 Soffit Panel

Super 1 Foods New Supermarket Building Athol, Idaho March 13, 2017

SECTION ROOF ACCESSORIES

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS

SECTION RESILIENT SHEET FLOORING

SECTION GYPSUM BOARD

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

8300/8500. CLASSIC STEEL Offering the highest level of insulation in a variety of classic designs. Ranch panel, Black finish, Stockton II windows

SPECIFICATIONS SECTION FLOOD CONTROL GATES. A. ASTM C 39 - Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

ThermalShell Modular Insulated Pre-Cast Panels

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

BEARING METAL STUD FRAMING

Product Guide Specification

ACOUSTICAL WALL TREATMENT SECTION 09840

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems

PIPE AND TUBE RAILINGS

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator

Section PANEL SIGNAGE

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

PRODUCT SPECIFICATIONS

PREMIUM SERIES CLASSIC LINE

Transcription:

SECTION 08361 RESIDENTIAL OVERHEAD DOORS SIGNATURE COLLECTION WOOD GARAGE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES. A. Residential Wood Overhead Doors. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete: Prepared opening in concrete. Execution requirements for placement of anchors in concrete wall construction. B. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry. Execution requirements for placement of anchors in masonry wall construction. C. Section 05500 - Metal Fabrications: Steel frame and supports. D. Section 06100 - Wood Blocking and Curbing: Rough wood framing and blocking for door opening. E. Section 07900 - Joint Sealers: Perimeter sealant and backup materials. F. Section 08710 - Door Hardware: Cylinder locks. G. Section 09900 - Paints and Coatings: Field painting. H. Section 16130 - Raceway and Boxes: Empty conduit from control station to door operator. I. Section 16150 - Wiring Connections: Electrical service to door operator. 1.3 REFERENCES A. ANSI/DASMA 108 - Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference B. UL: Underwriters Laboratories, Inc. 08361-1

C. ULC: Underwriters Laboratories of Canada. 1.4 DESIGN / PERFORMANCE REQUIREMENTS A. Wind Loads: Design and size components to withstand loads caused by pressure and suction of wind acting normal to plane of wall as calculated in accordance with applicable code. 1. Design pressure of lb/sq ft ( kpa). B. Wiring Connections: Requirements for electrical characteristics. 1. 115 volts, single phase, 60 Hz. C. Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. acceptable to authority having jurisdiction as suitable for purpose specified. D. Single-Source Responsibility: Provide doors, tracks, motors, and accessories from one manufacturer for each type of door. Provide secondary components from source acceptable to manufacturer of primary components. 1.5 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Shop Drawings: Indicate plans and elevations including opening dimensions and required tolerances, connection details, anchorage spacing, hardware locations, and installation details. D. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns. E. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. F. Manufacturer's Certificates: Certify products meet or exceed specified requirements. G. Operation and Maintenance Data. 1.6 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with minimum five years documented experience. B. Installer Qualifications: Authorized representative of the manufacturer with minimum five years documented experience. C. Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories, Inc. acceptable to authority having jurisdiction as suitable for purpose specified. 08361-2

1.7 DELIVERY, STORAGE, AND HANDLING A. Store products in manufacturer's unopened labeled packaging until ready for installation. B. Protect materials from exposure to moisture until ready for installation. C. Store materials in a dry, ventilated weathertight location. D. Store and dispose of solvent-based materials, and materials used with solventbased materials, in accordance with requirements of local authorities having jurisdiction. 1.8 WARRANTY A. Provide manufacturers product warranty as follows: 1. Signature Collection Wood Garage Door. Warranty: 1 year for product and all components to be free from defects in materials and workmanship. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Overhead Door Corporation, 2501 S. State Hwy. 121 Bus., Suite 200, Lewisville, TX 75067. ASD. Tel. Toll Free: (800) 929-3667. Phone: (469) 549-7100. Fax: (972) 906-1499. Web Site: www.overheaddoor.com. E- mail: arcat@overheaddoor.com. B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 RESIDENTIAL WOOD OVERHEAD DOORS A. Wood Sectional Overhead Doors: Signature Carriage Collection 570 Series Wood Doors by Overhead Door Corporation. 1. Door Assembly: Wood door with panel inserts with finger jointed rail and stiles frame construction. a. Size: As indicated on the Drawings. b. Panel Thickness: 1-3/8 inches (34.93 mm). c. Panel Style: Ship lap panels. d. Panel Detail: Medium density overlay smooth plywood panels with square top section solid. 1) Interior: 1/4 inch (6 mm) smooth Mahogany plywood 2) Exterior: (a) 3/8 inch smooth medium density overlay plywood. (b) 3/8 inch smooth Mahogany plywood. (c) 3/8 inch grooved medium density overlay plywood, 6-3/8 inches (162 mm) on center). e. Trim Options: 1) Vertical trim overlay 2 inch (specify number of panels). 2) Single Buck (Diagonal In). 08361-3

3) Double Cross Bucks. f. Insulation: 1) Full cavity expanded polystyrene. 2) Thermal Values: R-value of 4.75. g. Windload Design: Provide to meet the Design/Performance requirements specified. h. Window Design: 1) Window Location: Top section. 2) Glass: (a) 1/8 inch (3 mm) DSB clear glass. (b) 1/8 inch (3 mm) Plexiglass. (c) 1/8 inch (3 mm) Gray tint. (d) 1/8 inch (3 mm) Bronze tint. (e) 1/8 inch (3 mm) Antique art (semi-obscure). 2. Finish/Color: Paint grade, factory primed white. Sanding is required prior to top coat. 3. Rail and Stile Finish: finger jointed, 1-3/8 inches (34.93 mm) thick. a. Paint grade. b. Stain grade Hemlock or Cedar. 4. Hardware: 14-gauge hinges. 5. Springs: torsion springs. a. 10,000 cycle. b. 25,000 cycle. c. 50,000 cycle. 6. Lock: Interior mounted slide lock. 7. Weatherstripping: Co-extruded PVC bulb-type strip at bottom. 8. Track: Provide track as recommended by manufacturer to suit loading required and clearances available. 9. Rollers: ball bearing nylon-coated. 10. Manual Operation. 11. Electric Openers. B. Wood Sectional Overhead Doors: Signature Carriage Collection 571 Series Wood Doors by Overhead Door Corporation. 1. Door Assembly: Wood door with panel inserts with finger jointed Hemlock rail and stiles frame construction. a. Size: As indicated on the Drawings. b. Panel Thickness: 1-3/8 inches (34.93 mm). c. Panel Style: Ship lap panels. 1) Edge glued Hemlock raised panels with 1/4 inch (6 mm) Luan Mahogany Plywood Interior (4 panel design). 2) Edge glued cedar raised panels with 1/4 inch (6 mm) Luan Mahogany Plywood Interior (4 panel design). 3) Prime paint over stain grade (complete door); Paint grade, factory primed white. Sanding is required prior to top coat. d. Insulation: 1) Full cavity expanded polystyrene. 2) Thermal Values: R-value of 4.75. e. Windload Design: Provide to meet the Design/Performance requirements specified. f. Window Design: 1) Window Location: Top section. 2) Glass: (a) 1/8 inch (3 mm) DSB clear glass. (b) 1/8 inch (3 mm) Plexiglass. (c) 1/8 inch (3 mm) Gray tint. 08361-4

(d) 1/8 inch (3 mm) Bronze tint. (e) 1/8 inch (3 mm) Antique art (semi-obscure). 2. Rail and Stile Finish: finger jointed, 1-3/8 inches (34.93 mm) thick. a. Stain grade Hemlock. b. Stain grade Clear Cedar. c. Wire brush. 3. Hardware: 14-gauge hinges. 4. Springs: torsion springs. a. 10,000 cycle. b. 25,000 cycle. c. 50,000 cycle. 5. Lock: Interior mounted slide lock. 6. Weatherstripping: Co-extruded PVC bulb-type strip at bottom. 7. Track: Provide track as recommended by manufacturer to suit loading required and clearances available. 8. Rollers: ball bearing nylon-coated. 9. Manual Operation. 10. Electric Openers. C. Insulated Wood Sectional Overhead Doors: Signature Carriage Collection 580 Series Insulated Wood Doors by Overhead Door Corporation. 1. Door Assembly: Two sided smooth flush wood panels with insulated core with 1/2 inch (12.5 mm) smooth Extira overlays. 1-1/8 inch (28.57 mm) finger jointed rail and stile frame construction. a. Size: As indicated on the Drawings. b. Panel Thickness: Overall section thickness will vary depending on the exterior face and overlay material specified. c. Panel Style: Ship lap panels. d. Panel Detail: Medium density overlay smooth plywood panels with square top section solid. 1) Interior: 1/4 inch (6 mm) smooth Mahogany plywood 2) Exterior and Trim Options: (a) 3/8 inch (9.5 mm) smooth medium density overlay face material, 1/4 inch (6 mm) Mahogany plywood interior, with 1/2 inch (12.5 mm) smooth Extira overlays. (b) T1-11 plywood (4 inch or 8 inch on center) with Western Red Cedar Clear Trim. (c) 3/8 inch (9.5 mm) textured Mahogany plywood with (d) 3/8 inch (9.5 mm) smooth Mahogany plywood with (e) 1/2 inch (12.5 mm) smooth Marine Mahogany with (f) Western Red Cedar Clear, Tongue and Groove)with (g) Hemlock (Tongue and Groove) Exterior with Hemlock Trim. (h) African Mahogany, Tongue and Groove Exterior with African Mahogany Trim. (i) Color match Exterior and Overlay Material, Tongue and Groove. 3) Trim Design Elements: (a) Vertical trim overlay 4 inch (101 mm) (specify number of panels, up to 5). (b) Single buck (diagonal in). (c) Double cross bucks. 08361-5

(d) Watertable. 4) Panel Treatments: Wire brush texturing. 2. Insulation: Full cavity expanded polystyrene. 3. Thermal Values: R-value of 4.75. 4. Windload Design: Provide to meet the Design/Performance requirements specified. 5. Window Design: a. Window Location: Top section. b. Glass: 1) 1/8 inch (3 mm) DSB clear glass. 2) 1/8 inch (3 mm) Plexiglass. 3) 1/8 inch (3 mm) Gray tint. 4) 1/8 inch (3 mm) Bronze tint. 5) 1/8 inch (3 mm) Antique art (semi-obscure). 6) 1/2 inch (12.5 mm) Insulated divided (square top only). 7) 1/2 inch (12.5 mm) Insulated full pane. 6. Finish/Color: a. Paint grade: factory primed white - sanding is required prior to top coat; available on medium density overlay plywood panels. b. Stain grade: Available on Mahogany plywood panels. 7. Hardware: 14-gauge hinges. 8. Springs: torsion springs. a. 10,000 cycle. b. 25,000 cycle. c. 50,000 cycle. 9. Lock: Interior mounted slide lock. 10. Weatherstripping: Co-extruded PVC bulb-type strip at bottom. 11. Track: Provide track as recommended by manufacturer to suit loading required and clearances available. 12. Rollers: ball bearing nylon-coated. 13. Manual Operation. 14. Electric Openers. PART 3 EXECUTION 3.1 EXAMINATION A. Do not begin installation until openings and substrates have been properly prepared. B. Verify wall openings are ready to receive work and opening dimensions and tolerances are within specified limits. C. Verify electric power is available and of correct characteristics. D. If preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. 08361-6

3.3 INSTALLATION A. Install overhead doors, track and openers in accordance with approved shop drawings and the manufacturer's printed instructions. B. Coordinate installation with adjacent work to ensure proper clearances and allow for maintenance. C. Anchor assembly to wall construction and building framing without distortion or stress. D. Securely brace door tracks suspended from structure. Secure tracks to structural members only. E. Fit and align door assembly including hardware. F. Coordinate installation of electrical service with Section 16150. 3.4 CLEANING AND ADJUSTING A. Adjust door assembly to smooth operation and in full contact with weatherstripping. B. Clean doors, frames and glass. C. Remove temporary labels and visible markings. 3.5 PROTECTION A. Do not permit construction traffic through overhead door openings after adjustment and cleaning. B. Protect installed products until completion of project. C. Touch-up, damaged coatings and finishes and repair minor damage before Substantial Completion. END OF SECTION 08361-7