TRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS

Similar documents
PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION Solar Control Film WINDOW FILM. Copyright ARCAT, Inc. - All rights reserved

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Guide Specifications Section

Guide Specifications Section

Guide Specifications Section

Guide Specifications Section

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Guide Specifications Section

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

3M TM Decorative Radiant Film 76929SR

ACOUSTICAL WALL TREATMENT SECTION 09840

Guideline Specifications

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Alply CLASSIC WALL Architectural Insulated Panel Wall System

PRODUCT SPECIFICATIONS

GUIDE SPECIFICATION

GUIDE SPECIFICATION

Thermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)

Section Wood Grille Ceiling Panels

***********************************************************************************

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Rust-Oleum Industrial Brands Specification

SECTION BRICK FACED ARCHITECTURAL PRECAST CONCRETE. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

CSI GUIDE Countertops

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION ATHLETIC AND RECREATIONAL SURFACING. A. ASTM C 67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile.

Repair Maintenance Hangar Phase II August 2010

OptiLiner Banded Liner System, Thermal, Metal Building

SECTION IMPACT RESISTANT WALL PROTECTION

Architectural Specifications, Section Phenolic Lockers

Florock Seamless Flooring Systems

Note: Any verbiage written in red needs to be specified. All other options should be deleted

SECTION EPOXY TERRAZZO

3M Decorative Polyester Glass Film

Page 1 of 5

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

3 Specification 3.1 Dimensions Lites of overall dimensions ( x ) inches / mm.

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

Section Pre-Applied Sheet Membrane Waterproofing

Section PANEL SIGNAGE

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

A. This Section includes resinous flooring systems with epoxy body coat(s).

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.


Ash Brook Golf Course Scotch Plains, New Jersey

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

CS-100 Guide Specifications

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

A. Section includes glazing for the following products and applications and of the following types:

GUIDE SPECIFICATION: DUCT LINER

SECTION STILE AND RAIL WOOD DOORS

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION PRE-ENGINEERED BUILDING INSULATION

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

by Rollfab Metal Products

Service Bulletin. ATA 51-20: Processes Leading Edge Protective Tape Installation

SECTION BRICK MASONRY ASSEMBLIES

A. Submit product data sheets and literature verifying physical properties of materials.

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

ALL-ALUMINUM DOOR & WINDOW FRAMING

Engineering Branch Assets Delivery Group

ASTEC Re-Ply Roof System for AGED SINGLE PLY MEMBRANE (PVC, EPDM, THERMOPLASTIC) ROOFS

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

***************************************************************************************************************

B. Samples: Submit, for verification purposes, samples of the following:

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

CENTRIA FORMABOND II Metal Composite Wall System

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION SPECIAL FUNCTION GLAZING

Broadcast Parking Garage System

Specifications for FL-100 Soffit Panel

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Transcription:

TRIDENT SEC 04 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS A. Section 08 41 13 Aluminum-Framed Entrances and Storefronts: Glazing system to receive safety and security control film. B. Section 08 81 00 Glass Glazing: Glass and glazing materials to receive safety and security control film. 1.3 REFERENCES A. Code of Federal Regulations: 1. 16 CFR 1201 -Safety Standard for Architectural Glazing Materials. B. American National Standards Institute (ANSI): 1. Z97.1 - Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test. C. American Society for Testing and Materials (ASTM), latest edition: 1. D635 - Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position 2. D882 - Standard Test Method for Tensile Properties of Thin Plastic Sheeting. 3. D1044 - Standard Test Method for Resistance of Transparent Plastics to Surface Abrasion. 4. D1922 / 1004 - Standard Test Method for Propagation Tear Resistance of Plastic Film and Thin Sheeting by Pendulum Method 5. D1929 - Standard Test Method for Determining Ignition Temperature of Plastics 6. D2582 - Standard Test Method for Puncture-Propagation Tear Resistance of Plastic Film and Thin Sheeting 7. D3330 -Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape 8. D4830 - Standard Test Methods for Characterizing Thermoplastic Fabrics Used in Roofing and Waterproofing 9. E84 - Standard Test Method for Surface Burning Characteristics of Building Materials 10. E162 - Standard Test Method for Surface Flammability of Materials Using a Radiant Heat Energy Source 11. E662 - Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials. 08 87 23-1

D. British Standards Institution (BSI): 1. BS 6206 - Specification for Impact Performance Requirements for Flat Safety Glass. 2. EN 12600 - Glass in building. Pendulum test. Impact test method and classification for flat glass 3. EN 356 - Glass in building. Security glazing. Testing and classification of resistance against manual attack. E. GSA:US General Services Administration Explosion Resistant Standard Class 3A F. ISO 16933, Glass in building Explosion resistant security glazing Test and classification for arena air blast loading. 1.4 ACTION SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit manufacturer s product data for each type of window film specified. C. Samples: Submit 12-inch square sample of each window film [and color] specified for verification purposes. 1.5 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: Submit manufacturer s maintenance data for each safety and security control film installed for inclusion in Operation and Maintenance Manuals. 1.6 QUALITY ASSURANCE A. Abrasion resistance test results: 1. ASTM D1044: CS10 abrasive wheels, 500 gram weight, 50 cycles, increase in haze is less than 5%. B. Mock Ups: Build mockups to verify selections made under sample submittals and to evaluate surface preparation techniques and application workmanship. 1. Construct mockups in the location and of the size indicated or, if not indicated, as directed by Architect. 2. Approved mock ups may remain as a part of the completed Work if undisturbed at time of Substantial Completion. C. Preinstallation Conference: Conduct conference at project site to discuss methods and procedures relating to the installation of safety and security control films. 08 87 23-2

1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver safety and security control films to Project Site in manufacturer s unopened packaging. B. Store and protect safety and security control films in compliance with manufacturer's directions and as required to prevent damage to materials from condensation, temperature changes, direct exposure to sun, or other causes. 1.8 FIELD CONDITIONS A. Environmental Conditions: Do not proceed with application of safety and security control films when ambient and substrate temperature conditions are outside the limits permitted by film manufacturer or when substrates are wet from rain, frost, condensation, or other causes.. 1.9 WARRANTY A. Manufacturer s Warranty: Manufacturer s standard limited warranty in which manufacturer agrees to repair or replace materials that do not comply with requirements or fail in materials or workmanship within the specified warranty period. 1. Warranty Period: 12 Year (Interior Film applications) Limited Warranty against cracking, peeling, bubbling, delamination, or demetallization when properly installed and maintained on suitable substrates. B. Installer s Warranty: Installer's standard form in which installer agrees to repair or replace safety and security control films that do not comply with requirements or fail in workmanship within the specified warranty period and shall be included with the contract for installation. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Johnson Laminating & Coating Inc.; 20701 Annalee, Carson, CA 90746; (310) 635-4929; www.johnsonlaminating.com. B. Substitutions: Not allowed. 2.2 DESCRIPTION A. Trident: Optically clear, anti-fragmentation protective polymeric film, with an abrasion resistant coating on one side and a mounting adhesive on the other. 1. Uniformity: No noticeable visual defects, such as pinholes, streaks, thin spots, scratches, or banding In accordance with the IWFA visual acceptance standard, after installation. 2. Variation in Solar Specifications across Width: +/- 3 % average at any portion of the length. 3. Thickness: Nominal 4 mils (101.6 microns) with no evidence of coating voids, after the removal of the release liner. 4. Identification: Labeled in accordance with manufacturer s specifications. 08 87 23-3

2.3 SAFETY AND SECURITY FILM PERFORMANCE CRITERIA A. General: Performance specifications represent film mounted to 1/4 inch (6mm) clear glass, unless noted otherwise. B. Trident SEC04: 1. Film Color: Clear. 2. Film Gauge: 0.004. 3. Plies: 1. 4. Visible Light Transmission: 88%. 5. UV Reduction: 98%. 6. Tensile at Break: ASTM D882, 100 pli. 7. Peel Strength: ASTM D3330, >5 lbs/inch. 8. Puncture Strength: ASTM D2582, > 65 lbs. 9. Haze Change: ASTM D1044, < 4.4%. 10. Impact Tests: a. 2004 Test: ANSI Z97.1, Class B. b. Standard Test: 16 CFR 1201 US Gov., CAT I. c. BS 6206; 1981: Class B. d. Pendulum Test: EN12600, Class 2B. 11. Combustion Tests: ASTM E84-98 Surface Burning Test a. Smoke Density: 20. b. Flame Spread Rating (NFPA Class A UBC Class 1): 5. c. Time to Ignite: 205 seconds. d. Flame Front: 1 foot maximum. e. Rate of Burning: 0.1 in/sec. PART 3 EXECUTION 3.1 EXAMINATION A. Examine glazing system for upgrade viability prior to installation of window film. B. Verify satisfactory glass quality, sufficient edge bite and spacing, and elasticity of gasket material. Glass substrate should be free of defects, imperfections or damage of any kind including broken, chipped, cracked, or abraded areas. C. Verify frame and gasket are of satisfactory condition so as to not interfere with installation or typical thermal expansion and contraction of glazing system. D. Any unsatisfactory conditions must be corrected prior to proceeding with installation. 08 87 23-4

3.2 PREPARATION A. Comply with manufacturer s instructions for recommended surface preparation, cleaning and protection of the entire fenestration system. B. Prior to installation, clean glass thoroughly. Use mounting solution (recommended content: one capful of baby shampoo to 1 gallon of water) along with tools such as; squeegees, scrub pads, lint free towels and scrapers to ensure the glass surface is clean and smooth. 1. Ensure surface is free of any decals, debris, and dirt. 2. Clean frames and gasket material with towels and solution. 3. Use a final spray and squeegee cleaning to control dust as needed. C. Protect window frames and adjacent surfaces to prevent damage from water used during cleaning and installation. Use towels, tape, drop cloths and any other means recommended by manufacturers of adjacent materials to protect floors, walls and frames. 3.3 SAFETY AND SECURITY FILM APPLICATION A. Install window film in accordance with manufacturer's instructions. B. Thoroughly clean and dry glazing system. C. Cut film neatly and square to a slightly larger size than the exposed glass area. D. Remove release liner and spray both adhesive and glass surface with mounting solution to permit positioning on glass. Place film with adhesive side on glass, ensuring entire glass surface is covered. E. Spray outside surface with solution and squeegee film into place working from the center outward and from the top down, stopping a few inches from the edges. F. For a daylight installation trim film to align with edges of exposed glazing, leaving approximately 1/16 to 1/8 gap from the edge of the film to the gasketing of the window system to permit edge lay down. Use sharp blades recommended for this purpose. Replace blade after approximately 4 cuts. G. If using an anchoring system, trim film to appropriate size, larger than glass surface, as specified by the manufacturer of the retention system. H. Repeat spraying and squeegee procedure, vigorously moving water from center to right and left edges working from top down to bottom. I. Bump edges by applying firm pressure to force water out the edge using a hard card wrapped with a paper towel to ensure anchorage of the film edges. J. Once installation is complete, clean work area thoroughly. K. While some water may remain between the film and glass surface for up to 30 days, excessive amounts must be addressed immediately according to manufacturer s instructions. 08 87 23-5

3.4 SITE QUALITY CONTROL A. After installation and dry out period, film shall meet the IWFA visual acceptance standard. In general, the film shall appear uniform and unobtrusive when viewed from 10 feet. The film shall be free of physical defects such as wrinkles, creases, cuts or pinholes. The edges shall be consistent and appropriately distanced from frame. B. If installed film does not meet visual acceptance standard criteria, remove and replace with new film. 3.5 CLEANING A. Dry and thoroughly clean work area. B. Window film may be cleaned with standard household glass cleaners following the 30 day dry out period. Do not use abrasives or chemicals not specifically intended for glass. The soap based mounting solution described above is recommended. 1. Soft cloths or synthetic sponges are recommended; use a squeegee for removing the solution. C. Construction Waste Management: Manage construction waste in accordance with provisions of Division 1 Section Construction Waste Management. D. Replace damaged safety and security film before Substantial Completion. END OF SECTION 2016 Johnson Laminating and Coating Inc. All Rights Reserved. A copyright license to reproduce this specification is hereby granted to non-manufacturing engineers, architects and specification writers. 08 87 23-6