VOLTEX DS BENTONITE GEOTEXTILE WATERPROOFING WITH INTEGRATED POLYETHYLENE LINER

Similar documents
A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

SHOTCRETE APPLICATION MANUAL

VOLTEX DS SHOTCRETE FOR FOUNDATION SHORING WALLS

PRODUCT DATA SHEET SikaProof Bentonite

Section Pre-Applied Sheet Membrane Waterproofing

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

A. The work of this section includes, but is not limited to, the following:

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

PRODUCT DATA SHEET. Product Description

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

Start the installation at one corner of the building. Unroll the first sheet of MiraPLY-H square/parallel to the building wall, starting at one corner

BENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES

Pulaski County, Virginia

PREPRUFE SCS Blindside waterproofing system for shotcrete foundation walls

METHOD STATEMENT Sika BentoShield Max LM

BENTOMAT ST GEOSYNTHETIC CLAY LINER GUIDE SPECIFICATION

PLATON FOUNDATION WRAP

WATERPROOFING. MiraPLYTM. -H with SeamLOCKSM. Technology SCIENCE. SERVICE. SOLUTIONS. Description. Typical Properties.

BUILDING CODES Presented by CORUM ENGINEERING

BACKFILL COMPACTION FOR VOLCLAY WATERPROOFING: An Essential Ingredient for a Successful Project

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

AVM Drain Board 2000/2020

The Bentonite Construction Waterproofing Manual

LANDSCAPE RETAINING WALLS

Installation Information 2016

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Master Specification SECTION 02621

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

ITEM 458 WATERPROOFING FOR STRUCTURES

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Pacific Polymers Elasto-Deck BT Guide Specification

Waterproofing Products for UNDERGROUND STRUCTURES

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

A Design Review of Waterproofing Codes

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

SECTION UTILITY MANHOLES AND STRUCTURES

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

J41 Reinforced bitumen membrane roof coverings

PLYWOOD FLOATING FLOOR

1 Firestone EPDM Roofing Systems

WATERPROOFING SikaProof FULLY BONDED MEMBRANE SYSTEMS FOR WATERTIGHT BASEMENTS TECHNOLOGY & SYSTEMS

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

FLUID APPLIED WATERPROOFING

Gas Protection System Components

Redi Rock Specification and Installation Manual

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

Construction. Method Statement SikaProof A GREENSTREAK 02/09/2012 1/20

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SPECIFICATION FOR REINFORCED SOIL WALL

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

Light-Metal Roof Edge, Raised

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

Section ( ) SPECIFICATION FOR SEGMENTAL CONCRETE UNIT RETAINING WALL

Desmopol Application Guide onto Ply/OSB Deck

Project Address: Name of Person Completing Form:

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

KIM Best Practices Guide for Shotcrete Nov 2013

Sika KAB combination joint waterbars waterstopping systems

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

Concrete Slab-on-Ground

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

J41 Reinforced bitumen membrane roof coverings

Minimum Guidelines for the Design and Use of Underpins When Performing Foundation Stabilization and/or Supplementation UP-08

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

AVM System 500. Aussie Membrane 500

STEGO WRAP CLASS C VAPOR RETARDER A STEGO INDUSTRIES, LLC INNOVATION VAPOR RETARDERS , VERSION: JAN 5, 2018


WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

Specification. Project Name: Project reference: Written: by: Cathal Quinn Tel:

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

Floor Insulation Underlayment Section Sound Control Matting

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

GEOMEMBRANE INSTALLATION GUIDELINES RUFCO 20, 30 & 40 MIL UNREINFORCED DURA SKRIM 30, 36 & 45 MIL REINFORCED

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

1.02 RELATED WORK: Refer to the following sections for related work:

Application Specification:

Transcription:

BENTONITE GEOTEXTILE WATERPROOFING WITH INTEGRATED POLYETHYLENE LINER DESCRIPTION is a highly effective waterproofing composite of high strength geotextiles, 4.8 kg/sqm of sodium bentonite per square m, and a integrally bonded polyethylene liner. The high swelling, low permeable sodium bentonite is encapsulated between the two geotextiles. A proprietary needlepunch process interlocks the geotextiles together forg an extremely strong composite that maintains the equal coverage of bentonite, as well as, protects it from inclement weather and construction related damage. Once backfilled, hydrates and forms a monolithic waterproofing membrane. contains zero VOC, can be installed in almost any weather condition to green concrete, and most importantly, has proven effective on both new and remedial waterproofing projects worldwide. works by forg a low permeability membrane upon contact with water. When wetted, unconfined bentonite can swell up to 15 times its dry volume. When confined under pressure the swell is controlled, forg a dense, impervious waterproofing membrane. The swelling action of can self-seal small concrete racks caused by ground settlement, concrete shrinkage, or seismic action. forms a strong mechanical bond to concrete when the geotextile fibres are encapsulated into the surface of cast-in-place concrete. APPLICATIONS is designed for below-ground structural foundation surfaces. Typical castin-place concrete applications include backfilled concrete walls, earth-covered roofs, structural slabs, tunnels, and property line construction. Property line construction applications include soldier pile and lagging, steel sheet piling, secant/contiguous piling, shotcrete and stabilized earth retention walls. Applications may include structures under continuous or intermittent hydrostatic pressure. Where contaated ground-water conditions exist, use VOLTEX DSCR with contaant resistant sodium bentonite. VOLTEX DSCR resists higher levels of the following contaants: nitrates, phosphates, chlorides, sulfates, lime and organic solvents. Verify suitability of product by submitting a site water sample to CETCO for Water Compatibility Testing prior to installation. INSTALLATION General: Installation guidelines herein are for cast-in-place concrete applications. For shotcrete, precast concrete, and other applications not covered herein, refer to specific literature or contact CETCO for applicable installation guidelines. Install in strict accordance with the manufacturer s installation guidelines using accessory products as required. Also, use VOLTEX DSCR as required for contaated conditions. Install with the dark grey (woven) geotextile toward the concrete to be waterproofed. Install WATERSTOP-RX in all applicable horizontal and vertical concrete construction joints. Schedule waterproofing material installation to permit prompt placement of concrete or compacted backfill. STORAGE: Keep and all accessory products dry prior to backfill or concrete placement. Preparatory Work: Under Slab: Substrate should be smooth and compacted to a imum of 85% Modified Proctor density. Concrete Walls: Concrete should be free of voids and projections. Surface irregularities should be removed before installation. Apply BENTOSEAL over filled tie-bolt holes and to honeycombed concrete and surface voids. Tie-bolt holes extending through the wall should be completely filled with nonshrink cementitious grout and a piece of WATERSTOP-RX centred in the wall. Property Line Shoring Walls: Install only after proper substrate preparation has been completed and is suitable to receive the waterproofing. UNDER CONCRETE FLOOR SLABS is recommended for use under structural reinforced concrete slabs 100 mm thick or greater on a compacted earth/ gravel substrate. A imum 150 mm thick reinforced slab, if installed over a concrete blinding. Where hydrostatic conditions exist, install under footings and ground beams. Place over the properly prepared substrate with the dark grey (woven) geotextile side up. Overlap all adjoining edges a imum 100 mm and stagger sheet ends a imum 300 mm. Staple or nail edges together as required to prevent any displacement before and during concrete placement. Cut to closely fit around penetrations and pile caps. Install VOLCLAY GRANULES under cut edge at detailing and then apply a imum 19 mm thick fillet of BENTOSEAL to top of cut edge at penetrations, pile caps, ground beams, and other detailing. Extend BENTOSEAL onto and detail a imum of 50 mm. For hydrostatic conditions, should be installed under ground beams and footings. Extend VOL- TEX DS onto footing a imum 150 mm when required to tie into vertical wall waterproofing. Where property line retaining walls, such as secant/contiguous piling, steel sheet piling, soldier pile and lagging, are used as the outside concrete form, install a transition course at the base of the wall per Shoring Wall Transition instructions within the Property Line Construction section herein. Continue the underslab installation to the retaining wall overlapping the transition course a imum 300 mm. BACKFILLED CAST-IN-PLACE CONSTRUCTION Before installing the first course of, install BENTOSEAL fillet ( 38 x 38 mm) at the wall / footing transition corner. Trowel apply the BENTOSEAL to form a continuous line.

Pre-applied Installation Apply to timber formwork, either horizontally or vertically, by nailing or stapling, following general application guidelines for lapping all adjacent edges 100 mm, and staggering adjacent roll ends no less than 300 mm (avoiding four-way laps), and additionally ensuring that laps face downwards, as applicable. The polyethylene liner should be installed against the formwork and the woven (grey) geotextile should face the concrete to be waterproofed. Extend the full depth of the formwork, so that the laps 100 mm over the already cast into the slab edge and wall kicker, and allow no less than 150 mm at the top of the formwork, to provide waterproofing continuity later, if required. Position formwork as required, and tie/space forms, penetrating as necessary. Normal concrete practice is sufficient in terms of striking times for formwork, but due care should be taken to ensure that VOLTEX DS remains bonded to green concrete. Where a slab toe exists, and underslab VOLT- EX DS has terated at the top edge of the slab, additional will be required to link underslab/edge of slab with the pre-applied wall. Install BENTOSEAL fillet ( 38 x 38 mm) at the internal wall/slab corner, and place additional over the slab toe lapping 100 mm over the edge of slab, and continue over the toe terating under the unbonded wall flap at the back of the kicker. Post-applied Installation Beginning at the bottom corner of the wall, install horizontally oriented with 1.5 m on one wall and the remainder around the corner on the other wall surface. Cut the bottom edge of at the corner a imum of 150 mm so that can be extended onto the footing. Fasten into position with washer headed fasteners a maximum of 600 mm on centre. Then cut and install a section over the uncovered footing corner area. Apply BENTOSEAL at the section to overlap at the corner. Install adjacent rolls of the bottom course horizontally oriented. Each roll should overlap the preceding roll a imum 100 mm and should extend onto the footing a imum 150 mm. At inside wall corners apply a continuous 19 mm fillet of BENTOSEAL directly in the corner prior to installing. Stagger all vertical overlap joints a imum of 300 mm. For hydrostatic conditions, the vertical wall VOL- TEX DS should cover the entire footing and overlap the underslab waterproofing a imum 150 mm. Tape all membrane overlap seams with CETCO Seamtape. Cut to closely fit around penetrations. After installing, trowel a imum 19 mm thick fillet of BENTOSE- AL around the penetrations to completely fill any space between the penetration and the edge. Extend BENTO- SEAL onto the penetration and over the edge 38 mm. In areas where multiple penetrations are close together, it may be impractical to cut to fit around each penetration. Therefore, apply a 19 mm thick fillet of BENTOSEAL around base of each penetration and cover the entire area between the penetrations. Extend BENTOSEAL 38 mm onto the penetrations. Terate membrane 300 mm below finished ground elevation with washerhead fasteners maximum 300 mm on centre. Install CETBIT 300 flashing to primed concrete substrate with bottom edge overlapping top edge of membrane imum 100 mm. Overlap all roll ends a imum 100 mm to form a continuous flashing. Height of flashing shall be as per project details and specifications. Install a rigid teration bar along top edge of CETBIT 300; fastened maximum 300 mm on centre. Complete ground teration detail with tooled bead of CETSEAL along the top edge, at all penetrations through the flashing, and all exposed overlap seams. Backfill shall be placed and compacted to imum 85% Modified Proctor density promptly after waterproofing installation. Backfill should consist of compactable soil or angular aggregate (19 mm or less) free of debris, sharp objects, and stones larger than 19 mm. NOTE: is not recommended for masonry block walls. Contact CETCO regarding products and installation guidelines for masonry block foundation walls. PROPERTY LINE CAST-IN-PLACE CONSTRUCTION Use to waterproof various types of cast-in-place property line construction, including: secant/contiguous piling, steel sheet piling, soldier pile and lagging, and stabilized earth shoring walls. Following guidelines outline the installation of on secant/contiguous piled walls. For other property line shoring wall applications refer to the Cast-In-Place Product Manual or consult CETCO. For Shotcrete applications refer to the Shotcrete Application Manual for installation guidelines. Secant/Contiguous Piled Wall Preparation: Substrates should be free of large voids or protrusions. Voids, pits, and cracks in excess of 20 mm, should be parged flush using cementitious grout or BENTOSEAL. Protrusions greater than 20 mm should be removed or smoothed flush. Generally, gradual undulating surfaces are acceptable, sudden changes in level, i.e. ridges and hollows, are not. On contiguous piling, ensure that soil columns between piles are cut back to no less than one third of the pile diameter, to create a fixing cleavage, and reduce the likelihood of soil dislodging behind. Where required, cast concrete backblinding or apply shotcrete to contiguous piled walls to provide a sound substrate, particularly where large voids occur between piles due to unstable soil loss. Shoring Wall Transition: At base of shoring wall, install sheet horizontally oriented (dark grey woven geotextile facing installer) with the bottom edge extending out onto the horizontal substrate a imum 300 mm and the top edge of the sheet extending a. 300 mm above the finished slab elevation. Secure sheet to shoring wall with washerhead fasteners maximum 600 mm on centre. Overlap edges of sheets a imum 100 mm.

If the slab thickness is greater than 600 mm, install a second full sheet or cut strip of on the shoring wall to meet the 300 mm requirement above of the top slab elevation. Overlap top edge of previous sheet and edges of adjacent sheets a. 100 mm. Secant/Contiguous/Steel Sheet Piled Wall Installation: Follow the Shoring Wall Transition instructions for installation of transition course at the base of the secant/contiguous/steel sheet piled wall, with the 300 mm base flap cut and splayed as necessary, to allow the material to lay flat and provide continuity with the under slab installation. Use washer-head fasteners to secure, following general application guidelines for lapping all adjacent edges 100 mm, and staggering adjacent roll ends no less than 300 mm (avoiding four-way laps), and additionally ensuring that laps face downwards, as applicable, ensure that closely contours the application surface. For secant and contiguous piling, locate fasteners close to cleavages. For steel sheet piling, locate fasteners close to sheet pile interlocks and along internal/external sheet pile corners. Penetrations: Install a cut collar of VOL- TEX DS tightly around the penetration; extending a imum 300 mm radius. Apply BENTOSEAL over collar around penetration; extending BENTOSEAL a imum 75 mm radius at 6 mm thickness. Then install main course of membrane tightly around the penetration. Finally, detail around penetration with 19 mm thick a imum 300 mm radius of BENTOSEAL. With sleeved pipes, fill the gap between the pipe and the sleeve with non-shrink cementitious grout and install WATERSTOP-RX to both sides of sleeve. Ground Teration: Terate VOLT- EX DS membrane 300 mm below finished ground elevation with washer-head fasteners maximum 300 mm on centre. Install CETBIT 300 flashing to primed concrete substrate with bottom edge overlapping top edge of membrane imum 100 mm. Overlap all roll ends a imum 100 mm to form a continuous flashing. Height of flashing shall be per project details and specifications. Install a rigid teration bar along top edge of CETBIT 300; fastened maximum 300 mm on centre. Complete ground teration detail with tooled bead of CETSEAL along the top edge, at all penetrations through the flashing, and all exposed overlap seams. Secure all excavated overlap seams with washer-head fasteners maximum 600 mm on centre and then install Seamtape centred along overlap seams. Backfill shall be placed and compacted to imum 85% Modified Proctor density promptly after waterproofing installation. Backfill should consist of compactable soil or angular aggregate (19 mm or less) free of debris, sharp objects, and stones larger than 19 mm. LIMITATIONS should only be installed after substrate preparation has been properly completed and is suitable to receive the waterproofing system. Concrete work should be cast-in-place with conventional forms that produce a smooth surface. is designed for below-ground waterproofing applications where the product is properly confined. should not be installed in standing water or over ice. If ground water contains strong acids, alkalies, or is of a conductivity of 2500 μmhos/ cm or greater, water samples should be submitted to the manufacturer for compatibility testing. ULTRASEAL XP may be required if contaated ground water or saltwater conditions exist. is designed for use under reinforced concrete slabs 100 mm thick or greater on a compacted earth/gravel substrate. requires a imum 150 mm thick reinforced concrete slab if installed over a concrete blinding. is not designed for split-slab plaza deck construction. is not intended to seal expansion joints; contact CETCO for expansion joint applications. Do not use on masonry block foundation walls. Consult CETCO for special installation guidelines that apply to shotcrete and precast concrete construction. installation guidelines contained herein are for cast-in-place concrete applications and do not cover shotcrete or precast concrete applications. Refer to Product Manuals for additional property line shoring wall construction technique applications. Consult CETCO for applicable products and installation guidelines for applications not covered herein. SIZE AND PACKAGING is available in 1.1 m x 5 m rolls. Typical roll weight is approximately 37 kg. is packaged 35 rolls per pallet (176 sqm). is also available in 2.5 m x 20 m and 5m x 40 m standard size rolls. ACCESSORY PRODUCTS Install using accessory products in strict accordance with the manufacturer s installation guidelines and details. Primary accessory products include BENTOSEAL, VOLCLAY GRANULES, CETSEAL, Seamtape and CETBIT 300 ground flashing. ASSOCIATED SYSTEM PRODUCTS AQUADRAIN subsurface drainage composite and WATERSTOP-RX expanding concrete joint waterstop. IMPORTANT NOTICE: CONTACT CETCO FOR VERIFICATION OF SPECIFICATION AND IN- STALLATION REQUIREMENTS TO COMPLY WITH ISSUANCE FOR ELIGIBILITY OF HY- DROSHIELD WARRANTY.

Contiguous piled wall fastened to face of piled wall Reinforced concrete wall ( 150 mm thick) WATERSTOP-RX 101 ( 75 mm cover) BENTOSEAL fillet (38 mm x 38 mm) Concrete blinding INSTALL WITH DARK GREY (WOVEN) GEOTEXTILE FACING INSTALLER Property Line Contiguous Piled Wall Detail Retained earth 100 mm 300 mm PROPERTY LINE CONSTRUCTION 300 mm Cast-in-place concrete wall base wall course installed horizontally oriented Voids filled see technical data sheets for guidelines WATERSTOP-RX 75 mm coverage 100 mm Cast-in-place concrete wall Tooled bead of CETSEAL Finished ground Metal teration bar fastened 300 mm on centre (max) CETBIT 300 flashing membrane Top edge of fastened 300 mm on centre (max) corner transition under slab sheet installed horizontally oriented INSTALL WITH DARK GREY (WOVEN) GEOTEXTILE FACING INSTALLER Property Line Transition Ground Teration

TECHNICAL DATA MATERIAL PROPERTIES TEST METHOD NOMINAL VALUE BENTONITE Bentonite Free Swell ASTM D 5890 24 ml / 2 g Bentonite Fluid Loss ASTM D 5891 18 ml max. Bentonite mass / unit area EN 14196 4.8 kg/m² MEMBRANE COMPOSITE Hydrostatic Pressure Resistance ASTM D 5385 (mod) 70 m Peel Adhesion to Concrete ASTM D 903 (mod) 2.6 kn / m Hydraulic Conductivity ASTM D 5084 1.0 x 10 10 cm/s Tensile Strength (MD / CD) EN ISO 10319 10.0 kn/m / 10.0 kn/m Thickness @ 2 kpa EN ISO 9863-1 7.0 mm typical Puncture Resistance EN ISO 12236 1.8 kn Low Temperature Flexibility ASTM D 1970 unaffected @ 32 C 86/1650 1488-CPR-0030/Z 1035-CPD-018658 EN 13491:2004 + EN 13491:2004/A1:2006 contact@cetco.com UPDATED: JUNE 2016 IMPORTANT: The information contained herein supersedes all previous printed versions, and is believed to be accurate and reliable. For the most up-to-date information, please contact CETCO sales team. CETCO accepts no responsibility for the results obtained through application of this product. CETCO reserves the right to update information without notice. FORM: TDS_VOLTEX_DS_EMEA_EN_201606_V11