FLOOR CEILING ASSEMBLY DIRECT FIX TO I JOIST FCW-ATI-E6968.08 CONSTRUCTION Sheet Vinyl Ecore Forest FX Plywood 5/8" Waterproof Membrane (15lb Felt) Plywood 5/8" I Joist 12" Deep @ 24" OC Insulation Nominal 6" RSIC-1 Installed @ 16" x 48" OC 2 Layers 5/8" Fire Code X Gypsum Board FCW-ATI-E6968.08 STC STC 61 http://pac-intl.com/ fire_ratings_list.html IIC IIC 56 PAC International, LLC. All Rights Reserved. (866) 774-2100 Fax (866) 649-2710 RSIC is a registered Trade Mark of PAC International, LLC.
ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to PAC INTERNATIONAL, LLC Series/Model: RSIC-1 Classic Spaced 16" x 48" OC Traditional Layout Specimen Type: Weyerhauser TJI Assembly - 302 mm Overall Size: 3023 mm by 3632 mm STC 61 IIC 56 Test Specimen Identification: Floor Topping: 6.9 mm ECORE International Forest rx Rubber Back Sheet Vinyl Subfloor: 18.8 mm Oriented Strand Board Sheathing Subfloor: 18.8 mm Oriented Strand Board Sheathing Insulation: 88.9 mm CertainTeed R-11 Fiberglass Insulation Joist: 301.63 mm Weyerhaeuser TrusJoist 360 TJI Joist Ceiling Isolation: 28 mm PAC International RSIC-1 Classic Isolation Clips Ceiling Isolation: 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel Ceiling: 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Ceiling: 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Reference should be made to Intertek-ATI Report E6968.08-113-11 for complete test specimen description. This page alone is not a complete report. 130 Derry Courtaa York, PA 17406aa www.archtest.com www.intertek.com/building p. 717.764.7700 f. 717.764.4129
Page 1 of 5 Acoustical Performance Test Report PAC INTERNATIONAL, LLC 6585 Whispering Sands Drive Las Vegas, Nevada 89131 Report E6968.08-113-11 Test Date 04/30/15 Report Date 06/17/15 Project Scope Architectural Testing, Inc., a subsidiary of Intertek (Intertek-ATI), was contracted to conduct airborne sound transmission loss and impact sound transmission tests. The complete test data is included as attachments to this report. The client provided the test specimen. The specimen was constructed on the date of testing. Test Methods The acoustical tests were conducted in accordance with the following standards. The equipment listed in the attachments meets the requirements of the following standards. ASTM E 90-09, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions ASTM E 413-10, Classification for Rating Sound Insulation ASTM E 492-09, Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine ASTM E 989-06 (2012), Classification for Determination of Impact Insulation Class (IIC) ASTM E 2235-04 (2012) Standard Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods Test Procedure All testing was conducted in the VT test chambers at Intertek-ATI located in York, Pennsylvania. The microphones were calibrated before conducting the tests. The airborne transmission loss test was conducted in accordance with the ASTM E 90 test method using the single direction method. Two background noise sound pressure level and twenty sound absorption measurements were conducted at each of five microphone positions. Four sound pressure level measurements were made simultaneously in both rooms, at each of five microphone positions. 130 Derry Courtaa York, PA 17406aa www.archtest.com www.intertek.com/building p. 717.764.7700 f. 717.764.4129
Page 2 of 5 Test Procedure (Continued) The impact sound transmission test was conducted in accordance with the ASTM E 492 test method. Two background noise sound pressure level, two sound pressure level measurements with the tapping machine operating at each position specified by ASTM E 492, and twenty sound absorption measurements were conducted at each of five microphone positions. The air temperature and relative humidity conditions were monitored and recorded during all measurements. Test Conditions Source Room Receive Room Average Temperature 20.6 C Average Temperature 19.7 C Average Relative Humidity 49% Average Relative Humidity 48% Test Calculations The STC (Sound Transmission Class) and IIC (Impact Insulation Class) ratings were calculated in accordance with ASTM E 413 and ASTM E 989, respectively. Test Specimen Materials and Installation Details Material Dimensions (mm) Thickness (mm) Manufacturer and Series Quantity Average Weight Rubber Back Sheet Vinyl 3023 by 1829 6.9 Note: Loose laid onto the subfloor ECORE International Forest rx 10.98 m² 6.6 kg/m² Oriented Strand Board Sheathing Oriented Strand Board Sheathing Fiberglass Insulation TJI Joist 1219 by 2438 18.8 301.6 10.98 m² 10.25 kg/m² Note: Fastened to the additional sheathing layer with 25.4 mm screws on 203 mm centers along perimeter and 305 mm centers in the field. 1219 by 2438 18.8 N/A 10.98 m² 10.25 kg/m² Note: Fastened to joists with 76 mm by 3 mm framing nails on 203 mm centers along perimeter and 305 mm centers in the field. 2962 by 584 88.9 N/A Note: Secured at the top of joist cavity 57.2 by 3023 CertainTeed R-11 Weyerhaeuser TrusJoist 360 Note: Fastened to perimeter frame on 610 mm centers 10.98 m² 21.16 lin m 1.25 kg/m² 4.46 kg/m Isolation Clips 76.9 by 35.6 28.0 PAC International RSIC-1 Classic Note: Fastened to joists in a 610 mm by 1220 mm traditional pattern. 36 clips 0.06 kg/clip
Page 3 of 5 Test Specimen Materials and Installation Details (Continued) Material Dimensions (mm) Thickness (mm) Manufacturer and Series Quantity Average Weight Furring/Hat Channel Gypsum Panel Gypsum Panel 3657.6 by 76.2 Note: Installed into the isolation clips. 22.3 ClarkDietrich 087F125-18 29.1 lin m 0.48 kg/m National Gypsum Gold Bond 1219 by 3023 15.9 10.98 m² 11.23 kg/m² Fire-Shield Type X Note: Fastened to furring channels with 25.4 mm type S screws. Seams and perimeter sealed with acoustical caulk. National Gypsum Gold Bond 1219 by 3023 15.9 10.98 m² 11.23 kg/m² Fire-Shield Type X Note: Fastened to furring channels with 25.4 mm type S screws. Seams and perimeter sealed with acoustical caulk. Seams and screws covered with foil tape. Comments The total weight of the floor/ceiling assembly was 668.6 kg. Intertek-ATI will store samples of the test specimen for four years. Photographs of the test specimen are included in the attachments. The client did not supply drawings of the test specimen.
Page 4 of 5 Intertek-ATI will service this report for the entire test record retention period. Test records, such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek-ATI for the entire test record retention period. The test record retention period ends four years after the test date. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen tested. This report is intended to help in the client s quality assurance program, but it does not represent a continuous or exhaustive evaluation of the specimen tested or of other products or materials that were not evaluated. The statements and data provided herein do not constitute approval, disapproval, certification, or acceptance of performance or materials. This report may not be reproduced, except in full, without the written approval of Intertek-ATI. FOR INTERTEK-ATI: Leeland S. Hoover Technician II - Acoustical Testing Bradlay D. Hunt Project Manager - Acoustical Testing Attachments (6 Pages): This report is complete only when all attachments are included. * Stated by Client/Manufacturer N/A - Non Applicable
Page 5 of 5 Revision Log Revision Date Page(s) Description R0 06/17/15 N/A Original Report Issue This report produced from controlled document template ATI 00629(d), Revised 02/09/15.
Attachments Instrumentation Instrument Manufacturer Model ATI Number Data Acquisition Unit National Instruments PXI-1033 63763 06/14 Microphone Calibrator Norsonic 1251 Y002919 06/14 Receive Room Microphone PCB Piezotronics 378B20 64340 04/14 Date of Calibration * Receive Room Microphone PCB Piezotronics 378B20 63744 04/14 Receive Room Microphone PCB Piezotronics 378B20 63745 04/14 Receive Room Microphone PCB Piezotronics 378B20 63746 04/14 Receive Room Microphone PCB Piezotronics 378B20 63747 04/14 Receive Room Environmental Indicator Comet T7510 63810 63811 09/14 Source Room Microphone PCB Piezotronics 378B20 63738 04/14 Source Room Microphone Source Room Microphone Source Room Microphone PCB Piezotronics 378B20 63739 04/14 PCB Piezotronics 378B20 63748 04/14 PCB Piezotronics 378B20 63742 04/14 Source Room Microphone PCB Piezotronics 378B20 63741 04/14 Source Room Environmental Indicator * The calibration frequency for this equipment is every two years per the manufacturer's recommendation. Test Chambers VT Receive Room Volume 157.31 m³ Comet T7510 63812 09/14 Tapping Machine Look Line s.r.l. EM50 (TM50) VT Source Room Volume 190 m³ 65351 11/14 Page 1 of 6
AIRBORNE SOUND TRANSMISSION LOSS ASTM E 90 Test Date 04/30/15 Data File No. E6968.08 Client Description PAC International, LLC 6.9 mm ECORE International Forest rx Rubber Back Sheet Vinyl, 18.8 mm Oriented Strand Board Sheathing, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm CertainTeed R-11 Fiberglass Insulation, 301.63 mm Weyerhaeuser TrusJoist 360 TJI Joist, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Specimen Area 10.98 m² Technician Leeland S. Hoover Freq Background Source Receive Specimen 95% Number Absorption SPL SPL SPL TL Confidence of (Hz) (db) (m²) (db) (db) (db) Limit Deficiencies 80 65.9 18.0 108 69 39 2.90-100 46.9 13.6 107 69 39 2.30-125 38.3 10.3 105 66 41 0.90 4 160 36.2 9.6 107 66 43 1.10 5 200 30.8 11.2 106 59 48 1.20 3 250 28.9 11.1 106 54 53 0.80 1 315 29.2 10.6 106 53 54 0.80 3 400 27.3 9.3 105 52 56 0.40 4 500 24.5 8.9 105 50 57 0.70 4 630 26.3 8.9 106 50 59 0.60 3 800 27.7 8.6 106 47 61 0.40 2 1000 25.7 8.6 105 44 63 0.30 1 1250 25.1 9.0 106 43 65 0.60 0 1600 21.3 8.8 106 41 67 0.30 0 2000 14.6 9.9 106 40 68 0.30 0 2500 9.7 10.7 105 39 68 0.30 0 3150 8.2 11.5 105 34 71 0.30 0 4000 6.6 13.3 105 31 73 0.60 0 5000 5.8 15.8 104 28 75 0.70-6300 5.9 19.9 98 19 78 0.90-8000 6.1 26.7 97 14 10000 6.2 32.3 92 8 81 80 1.10-0.90 - STC Rating Deficiencies 61 30 (Sound Transmission Class) (Sum of Deficiencies) Notes: 1) Receive Room levels less than 5 db above the Background levels are highlighted in yellow. 2) Specimen TL levels listed in red indicate the lower limit of the transmission loss. 3) Specimen TL levels listed in green indicate that there has been a filler wall correction applied ATI 00614 Revised 02/09/15 Page 2 of 6
AIRBORNE SOUND TRANSMISSION LOSS ASTM E 90 Test Date 04/30/15 Data File No. E6968.08 Client Description PAC International, LLC 6.9 mm ECORE International Forest rx Rubber Back Sheet Vinyl, 18.8 mm Oriented Strand Board Sheathing, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm CertainTeed R-11 Fiberglass Insulation, 301.63 mm Weyerhaeuser TrusJoist 360 TJI Joist, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Specimen Area 10.98 m² Technician Leeland S. Hoover 100 Airborne Sound Transmission Loss 90 80 Sound Transmission Loss (db) 70 60 50 40 30 20 10 Specimen TL Contour Curve 0 63 125 250 500 1000 2000 4000 8000 Frequency (Hz) ATI 00614 Revised 02/09/15 Page 3 of 6
IMPACT SOUND TRANSMISSION ASTM E 492 Test Date 04/30/15 Data File No. E6968.08 Client Description PAC International, LLC 6.9 mm ECORE International Forest rx Rubber Back Sheet Vinyl, 18.8 mm Oriented Strand Board Sheathing, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm CertainTeed R-11 Fiberglass Insulation, 301.63 mm Weyerhaeuser TrusJoist 360 TJI Joist, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Specimen Area 10.98 m² Technician Leeland S. Hoover Freq Background SPL Absorption Normalized Impact SPL 95% Number Confidence (Hz) (db) (m²) (db) Limit Deficiencies 80 66.0 18.2 67 3.1-100 48.1 12.2 64 1.9 8 125 39.1 9.4 63 2.5 7 160 37.5 9.3 60 0.6 4 200 33.1 10.6 60 1.0 4 250 31.7 11.3 56 1.1 0 315 31.9 10.8 54 0.9 0 400 29.7 9.6 49 1.0 0 500 28.8 8.9 44 1.1 0 630 29.1 8.9 41 0.8 0 800 29.1 8.6 36 1.0 0 1000 28.0 8.8 30 0.3 0 1250 28.7 9.1 27 0.9 0 1600 23.4 8.9 22 0.4 0 2000 15.6 9.8 18 0.5 0 2500 10.2 10.7 13 0.4 0 3150 8.3 11.6 10 0.7 0 4000 6.9 13.3 9 0.5-5000 6.2 15.8 8 0.7-6300 6.4 19.9 8 0.9-8000 7.0 26.3 9 0.9-10000 6.4 32.5 9 0.9 - of IIC Rating Deficiencies 56 23 (Impact Insulation Class) (Sum of Deficiencies) Note: Receive Room levels less than 5 db above the Background levels are highlighted in yellow. ATI 00615 Revised 02/09/15 Page 4 of 6
IMPACT SOUND TRANSMISSION ASTM E 492 Test Date 04/30/15 Data File No. E6968.08 Client Description PAC International, LLC 6.9 mm ECORE International Forest rx Rubber Back Sheet Vinyl, 18.8 mm Oriented Strand Board Sheathing, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm CertainTeed R-11 Fiberglass Insulation, 301.63 mm Weyerhaeuser TrusJoist 360 TJI Joist, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel, 15.9 mm National Gypsum Gold Bond Fire-Shield Type X Gypsum Panel Specimen Area 10.98 m² Technician Leeland S. Hoover Impact Sound Transmission 100 10 90 20 80 30 Sound Pressure Level (db) 70 60 50 40 30 40 50 60 70 80 Impact Insulation Class (IIC) 20 90 10 Normalized Impact SPL 100 0 110 63 125 250 500 1000 2000 4000 8000 Contour Curve Frequency (Hz) ATI 00615 Revised 02/09/15 Page 5 of 6
Photographs Source Room View of Test Specimen Installation Receive Room View of Test Specimen Installation Page 6 of 6