Hourly Analysis Program v.4.1 Page 1 of 1

Similar documents
Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

Ceiling Radiant Cooling Panels

Great Ocean Rd Ice Creamery

Report SEG W / March 2014 Right-Sized Residence Manual J Street, Oak Park, IL Prepared by: Tracy Savoy

RESIDENTIAL HVAC SYSTEM DESIGN REPORT

Underf loor For Schools

ENERGY RECOVERY, CALCULATION METHODS

Air Conditioning Inspections for Buildings Assessing Equipment Sizing

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

Ventilative Cooling potential tool

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

Energy modeling in IDA ICE according to ASHRAE , app. G

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

Product Data. (Unit shown with optional economizer.)

Canada Published online: 28 Feb 2011.

Application of Advanced Energy Technologies

Sustainable Chilled Beam Design

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

Proceedings of BS2015: 14th Conference of International Building Performance Simulation Association, Hyderabad, India, Dec. 7-9, 2015.

ABSTRACT I. INTRODUCTION II. METHODS AND MATERIAL

Load Estimating for Air Conditioning using Computer Software Approach

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

DesignTools Software Energy Analyzer User Manual

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Principles of Ventilation and Air Conditioning Design & Installation

M 158 DEPOSITED. April 7, 2017 B.C.REG.

2012 Fiscal Impact International Mechanical Code

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

15 th NATIONAL CERTIFICATION EXAMINATION FOR ENERGY AUDITORS August, 2014

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

The Mirenda Center for Sports, Spirituality, and Character Development

Available online at ScienceDirect. Energy Procedia 101 (2016 )

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

AIRCOOL VENTILATORS FURTHER INFORMATION

50KC Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

Design and development of a residential gas-fired heat pump

Guide to Heating and Cooling Load Calculations in High Performance Homes

16 th NATIONAL CERTIFICATION EXAMINATION FOR ENERGY MANAGERS & ENERGY AUDITORS September, 2016

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

Milwaukee, WI. Darron Rempel

Green Building Guideline of Jordan

The optimization of the mechanical night cooling system in the office building

Green Building Guideline of Jordan

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Chilled Beams. The new system of choice?

Sub Wet-Bulb Evaporative Chiller

ENERGY CALCULATOR & MODELLING PROTOCOL

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics

Evaluation of natural ventilation systems in a landscaped office.

Moisture and temperature conditions in cold lofts and risk of mould growth

The pros and cons of chilled beams

Model Based Building Chilled Water Loop Delta-T Fault Diagnosis

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.) C09248

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.

Asset Energy Calculator Guidance

McCarran International Airport Terminal 3

UC Berkeley HVAC Systems

The Present and Future of Refrigeration, Power Generation and Energy Storage. R.Z. Wang Shanghai Jiao Tong University

THERMAL STORAGE FEASIBILITY STUDY

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

PERFORMANCE EVALUATION FOR INDIRECT EVAPORATIVE COOLING ON CELLULAR SITES

Introduction of the latest Technology of Energy Conservation

MODELLING THE IMPACTS OF NEW UK FUTURE WEATHER DATA ON A SCHOOL BUILDING

Advanced Variable Air Volume Control Sequences. Steven T. Taylor, PE Taylor Engineering Alameda, CA

Performance evaluation of an actual building airconditioning

Modeling the Performance of ECM and SCR Series Fan-Powered Terminal Units in Single-Duct VAV Systems

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

Dyno Test Rooms Professional Chassis, Engine & Specialty Test Rooms for the PowerSports & Product Testing Market

Technical Report #1 ASHRAE Standard 62: Ventilation Compliance Evaluation

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

Assignment 3 Integrated Energy Design

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Parameters of the Atmospheric Air in the Dimensioning of Industrial Cooling Tower

St. Monica Food Pantry Testing, Adjusting, & Balancing for HVAC sys-tek No

I S O. Eco-Smart Energy Recovery Ventilator

Chilled Water Plant Redesign

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

Module 15. Country Specific Legislation

The Centre for Sustainable Building (ZUB) * A Case Study

Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

AHU Models Using Whole Building Cooling and Heating Energy Consumption Data

Evaluation of Underfloor Air Distribution

DESIGN OF A GREEN DEMO BUILDING IN A HOT AND HUMID CITY IN CHINA. Ana Bacall Sebesta Blomberg & Associates Woburn, MA

ApacheView user guide

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

CLIMATE ENERGY INDEX AND BUILDING ENERGY INDEX: NEW INDICES TO ASSESS AND BENCHMARK BUILDING ENERGY PERFORMANCE

Building & Ductwork Airtightness Standards

Energy Recovery Ventilation Equipment

Integration of Mechanical System Redesign. Geothermal Heat Pumps with DOAS

I. Khoo, BEng(Hons), G.J. Levermore, BSc, ARCS, PhD, DIC, CEng, FCIBSE, MASHRAE, MInstE, K.M. Letherman, BSc, MSc, PhD, CEng, FIEE, FCIBSE.

CI/SfB (57.7) 1st edition

Calculating the Efficiency of Energy Recovery Ventilation and its Effect on Efficiency and Sizing of Building HVAC Systems

Transcription:

Air System Design Load Summary for Zona 3 Project Name: Av. Cabildo 3067, 4 piso 02/13/2011 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1500 HEATING DATA AT DES HTG COOLING OA DB / WB 34.9 C / 23.8 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent Sensible Latent ZONE LOADS Details (W) (W) Details (W) (W) Window & Skylight Solar Loads 10 m² 1166-10 m² - - Wall Transmission 25 m² 485-25 m² 819 - Roof Transmission 18 m² 183-18 m² 223 - Window Transmission 10 m² 413-10 m² 1010 - Skylight Transmission 0 m² 0-0 m² 0 - Door Loads 0 m² 0-0 m² 0 - Floor Transmission 17 m² 0-17 m² 0 - Partitions 18 m² 0-18 m² 0 - Ceiling 0 m² 0-0 m² 0 - Overhead Lighting 367 W 342-0 0 - Task Lighting 0 W 0-0 0 - Electric Equipment 800 W 775-0 0 - People 6 394 360 0 0 0 Infiltration - 0 0-0 0 Miscellaneous - 0 0-0 0 Safety Factor 5% / 5% 188 18 5% 103 0 >> Total Zone Loads - 3946 379-2154 0 Zone Conditioning - 3763 379-2109 0 Plenum Wall Load 0% 0-0 0 - Plenum Roof Load 0% 0-0 0 - Plenum Lighting Load 0% 0-0 0 - Return Fan Load 362 L/s 0-362 L/s 0 - Ventilation Load 42 L/s 526 406 42 L/s 1102 0 Supply Fan Load 369 L/s 7-369 L/s -7 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 197-5% 108 - >> Total System Loads - 4494 785-3312 0 Central Cooling Coil - 4494 785-0 0 Central Heating Coil - 0 - - 3312 - >> Total Conditioning - 4494 785-3312 0 Key: Positive values are clg loads Positive values are htg loads Negative values are htg loads Negative values are clg loads

Psychrometric Analysis for Zona 3 Location: Buenos Aires, Argentina Altitude: 19.8 m. Data for: February DESIGN COOLING DAY, 1500 1. Outdoor Air 0.0200 2. Mixed Air 3. Central Cooling Coil Outlet 4. Supply Fan Outlet 5. Duct Heat 6. Room Air 7. Return Duct Outlet 4 35 2 76 1 0.0175 0.0150 0.0125 0.0100 0.0075 0.0050 Specific Humidity ( kg/kg ) 0.0025 0 5 10 15 20 25 30 35 Temperature ( C ) 0.0000

System Psychrometrics for Zona 3 February DESIGN COOLING DAY, 1500 TABLE 1: SYSTEM DATA Dry-Bulb Specific Sensible Latent Temp Humidity Airflow Heat Heat Component Location ( C) (kg/kg) (L/s) (W) (W) Ventilation Air Inlet 34.9 0.01400 42 526 406 Vent - Return Mixing Outlet 25.7 0.01112 369 - - Central Cooling Coil Outlet 15.6 0.01040 369 4494 785 Central Heating Coil Outlet 15.6 0.01040 369 0 - Supply Fan Outlet 15.6 0.01040 369 7 - Cold Supply Duct Outlet 16.1 0.01040 351 197 - Zone Air - 25.0 0.01076 344 3763 379 Zone Direct Exhaust Outlet 25.0 0.01076 7 - - Return Plenum Outlet 25.0 0.01076 344 0 - Duct Leakage Air Outlet 15.6 0.01040 18 - - Return Duct Outlet 24.5 0.01074 362 - - Return Fan Outlet 24.5 0.01074 362 0 - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.207; At site altitude = 1.204 W/(L/s-K) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 2947.6; At site altitude = 2940.6 W/(L/s) Site Altitude = 19.8 m TABLE 2: ZONE DATA Zone Terminal Zone Sensible Zone Zone Zone Heating Heating Load T-stat Cond Temp Airflow Coil Unit Zone Name (W) Mode (W) ( C) (L/s) (W) (W) Zone 3 3946 Cooling 3763 25.0 351 0 0

System Psychrometrics for Zona 3 WINTER DESIGN HEATING TABLE 1: SYSTEM DATA Dry-Bulb Specific Sensible Latent Temp Humidity Airflow Heat Heat Component Location ( C) (kg/kg) (L/s) (W) (W) Ventilation Air Inlet -0.6 0.00182 42-1102 0 Vent - Return Mixing Outlet 18.6 0.00182 369 - - Central Cooling Coil Outlet 18.6 0.00182 369 0 0 Central Heating Coil Outlet 26.0 0.00182 369 3312 - Supply Fan Outlet 26.0 0.00182 369 7 - Cold Supply Duct Outlet 25.8 0.00182 351-108 - Zone Air - 20.8 0.00182 344-2109 0 Zone Direct Exhaust Outlet 20.8 0.00182 7 - - Return Plenum Outlet 20.8 0.00182 344 0 - Duct Leakage Air Outlet 26.0 0.00182 18 - - Return Duct Outlet 21.0 0.00182 362 - - Return Fan Outlet 21.0 0.00182 362 0 - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.207; At site altitude = 1.204 W/(L/s-K) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 2947.6; At site altitude = 2940.6 W/(L/s) Site Altitude = 19.8 m TABLE 2: ZONE DATA Zone Terminal Zone Sensible Zone Zone Zone Heating Heating Load T-stat Cond Temp Airflow Coil Unit Zone Name (W) Mode (W) ( C) (L/s) (W) (W) Zone 3-2154 Heating -2109 20.8 351 0 0 Hourly Analysis Program v.4.1 Page 2 of 2

Air System Sizing Summary for Zona 3 Project Name: Av. cabildo 3067, 4 piso 02/13/2011 Air System Information Air System Name... Zona 3 Equipment Class... SPLT AHU Air System Type... SZCAV Number of zones... 1 Floor Area... 17.0 m² Sizing Calculation Information Zone and Space Sizing Method: Zone L/s... Peak zone sensible load Space L/s... Individual peak space loads Calculation Months... Jan to Dec Sizing Data... Calculated Central Cooling Coil Sizing Data Total coil load... 5.3 kw Sensible coil load... 4.5 kw Coil L/s at Feb 1500... 369 L/s Max block L/s at Jan 1600... 369 L/s Sum of peak zone L/s... 351 L/s Sensible heat ratio... 0.851 m²/kw... 3.2 W/m²... 310.5 Water flow @ 5.6 K rise...... N/A Load occurs at... Feb 1500 OA DB / WB... 34.9 / 23.8 C Entering DB / WB... 25.7 / 19.1 C Leaving DB / WB... 15.6 / 15.0 C Coil ADP... 14.5 C Bypass Factor... 0.100 Resulting RH... 54 % Design supply temp.... 14.4 C Zone T-stat Check... 1 of 1 OK Max zone temperature deviation... 0.0 K Central Heating Coil Sizing Data Max coil load... 3.3 kw Coil L/s at Des Htg... 369 L/s Max coil L/s... 369 L/s Water flow @ 11.1 K drop...... N/A Load occurs at... Des Htg W/m²... 194.8 Ent. DB / Lvg DB... 18.6 / 26.0 C Supply Fan Sizing Data Actual max L/s at Jan 1600... 369 L/s Standard L/s... 368 L/s Actual max L/(s-m²)... 21.70 L/(s-m²) Outdoor Ventilation Air Data Design airflow L/s... 42 L/s L/(s-m²)... 2.50 L/(s-m²) Fan motor BHP... 0.01 BHP Fan motor kw... 0.01 kw Fan static... 10 Pa l/s/person... 7.08 l/s/person

Zone Design Load Summary for Zona 3 Zone 3 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jan 1600 HEATING DATA AT DES HTG COOLING OA DB / WB 34.5 C / 23.7 C HEATING OA DB / WB -0.6 C / -3.2 C OCCUPIED T-STAT 23.9 C OCCUPIED T-STAT 21.1 C Sensible Latent Sensible Latent ZONE LOADS Details (W) (W) Details (W) (W) Window & Skylight Solar Loads 10 m² 1113-10 m² - - Wall Transmission 25 m² 523-25 m² 819 - Roof Transmission 18 m² 236-18 m² 223 - Window Transmission 10 m² 408-10 m² 1010 - Skylight Transmission 0 m² 0-0 m² 0 - Door Loads 0 m² 0-0 m² 0 - Floor Transmission 17 m² 0-17 m² 0 - Partitions 18 m² 0-18 m² 0 - Ceiling 0 m² 0-0 m² 0 - Overhead Lighting 367 W 344-0 0 - Task Lighting 0 W 0-0 0 - Electric Equipment 800 W 777-0 0 - People 6 396 360 0 0 0 Infiltration - 0 0-0 0 Miscellaneous - 0 0-0 0 Safety Factor 5% / 5% 190 18 5% 103 0 >> Total Zone Loads - 3987 379-2154 0

Zone Sizing Summary for Zona 3 Sizing Calculation Information Zone and Space Sizing Method: Zone L/s... Peak zone sensible load Space L/s... Individual peak space loads Calculation Months... Jan to Dec Sizing Data... Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (kw) (L/s) (L/s) Load (kw) (m²) L/(s-m²) Zone 3 4.0 351 351 Jan 1600 2.2 17.0 20.62 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name / Sensible of Flow Load Area Space Space Name Mult. (kw) Load (L/s) (kw) (m²) L/(s-m²) Zone 3 Zona 3 2 2.0 Jan 1600 175 1.1 8.5 20.62