A Protocol to Determine the Performance of South Facing Double Glass Façade System

Similar documents
Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

A Solar Wall System Utilized in Rural Houses of Northeast China

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

Analysis 2: Alternative Thermal Window Design

Introduction to basics of energy efficient building design

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Solar Shading System Based on Daylight Directing Glass Lamellas

SOLAR ENGINEERING OF THERMAL PROCESSES

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Feasibility study of a roof top Solar room heater

AIRFLOW WINDOW: NUMERICAL STUDY AND SENSIBILITY ANALYSIS OF THERMAL PERFORMANCES. *Corresponding author:

5.0 Daylighting Analysis (Breathe Study)

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Stiffener Design for Beam-to-Column Connections. Michelle L. Holland

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Solar Flat Plate Thermal Collector

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

BEYOND ARROWS: ENERGY PERFORMANCE OF A NEW, NATURALLY VENTILATED DOUBLE-SKIN FACADE CONFIGURATION FOR A HIGH-RISE OFFICE BUILDING IN CHICAGO

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

Design of Experiment for Solar Water Heater Performance Analysis

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Exergy analysis of a flat plate solar collector

AIC TECH 2015 Sustainability in Practice Turning Ideas into Reality Jan 16, 2015 FUTURE & NET ZERO BUILDINGS

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

ASHRAE Standard 62.1 Ventilation Report

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

Compliance Evaluation: ASHRAE Standard Ventilation for Acceptable Indoor Air Quality

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Selecting Energy Efficient New Windows in Tennessee

Selecting Energy Efficient New Windows in Nevada

ARCH 5901 A02 Office Building Program FALL 2015

Selecting Energy Efficient New Windows in Illinois

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Selecting Energy Efficient Replacement Windows in Arizona

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

Italcementi Center for Research and Innovation

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

Integration of Energy Efficiency Through Architectural Design. Presentation by TERI. 10 th June,2010

CFD Simulation Methodology for Ground-Coupled Ventilation System

Daylight, Solar Gains and Overheating Studies in a Glazed Office Building

ART ECO, CHONGMING ISLAND, CHINA MONIKA THADHANI COLLEGE OF ARCHITECTURE

Student Modeling Competition

Great Homes Checklist - Passive Solar Design. Energy Center fact sheet 4/2006

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

PEARL RIVER TOWER GUANGZHOU, CHINA LUKE LEUNG

Extended pilot study of an energy efficient glazed office building during pre-design and design. Åke Blomsterberg (WSP och LTH)

Great Ocean Rd Ice Creamery

DISPLACEMENT VENTILATION

NASA Langley Research Center Administration Office Building One Hampton, VA. Project Proposal. Introduction to Proposed Design Alternatives Revision 1

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

ADJUSTABLE SOLAR SHADING AND HEAT CONSERVATION LOUVRES FOR TRANSPARENT, MULTI-LAYERED GLASS FACADES

Variants of shaping tall building construction and their impact on elevation energy functionality

Teaser Project Munich

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

Ventilative Cooling potential tool

EADQUARTERS. Thesis Revised Proposal. Stephanie Kunkel Mechanical Option

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Investigation of a Solar active glass facade

caused by subjective factors such as oversimplified modeling for simulation, nonuniform calculation methods, casual input parameters and boundary cond

The optimization of the mechanical night cooling system in the office building

UiTM Shah Alam. Architectual Design of Smart Micro-grid and Eco-Community. Natchais Srisukpornchai

Post Tower Bonn, Germany

Evaluation of efficiency and collector time constant of a solar flat plate collector

EXPERIMENTAL INVESTIGATION OF SOLAR AIR COLLECTOR BY COMPARING GLASS WOOL AND FOAM AS AN INSULATION MATERIAL

THERMAL ANALYSIS OF A FACADE-MOUNTED PV ARRAY

MODELLING THE URBAN MICROCLIMATE AND ITS INFLUENCE ON BUILDING ENERGY DEMANDS OF AN URBAN NEIGHBOURHOOD

Solar Hot Air Collectors. Rob Taisey Assured Solar Energy

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Daylight Efficiency Prediction of Courtyard vs. Conventional Building Models Using Simulation Tool under Specific Climate Conditions

JAKARTA GREEN BUILDING USER GUIDE VOL. 1 BUILDING ENVELOPE. The Government of the Province of Jakarta Capital Special Territory

Cost Benefits of SunGuard SN 54

Selection of Glass and its effect on Heat Load Estimation

Single and Double Skin Glazed Office Buildings

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 4, Issue 3, September 2014

C H A P T E R 3. Completing the Residential Analysis Worksheet STEP 1: WINDOWS AND OTHER GLASS AREAS

Design Considerations for Flat Plate Solar Water Heater System

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

ENERGY STAR WINDOWS PERFORMANCE AND ORIENTATION

PDHengineer.com Course M-3020

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Solar Energy Technologies

Energy equivalent R-value

The Performance of External Shading Devices and Daylighting Rule of Thumb for a Tropical Climate

Modeling the Brillhart House

The Teatinas of Lima: Energy Analysis and Possibilities of Contemporary Use

Ventilation and Airtightness, different relationship for different quality of buildings

Comparative Analysis of Retrofit Window Film to Replacement with High Performance Windows

BEST4 Conference April 13-15, 2015

THE USE OF SOLAR DESIGN DAYS IN A PASSIVE SOLAR HOUSE CONCEPTUAL DESIGN TOOL

Transcription:

A Protocol to Determine the Performance of South Facing Double Glass Façade System A Preliminary Study of Active/Passive Double Glass Façade Systems by Shang-Shiou Li Thesis Submitted to the Faculty of the Virginia Polytechnic Institute and State University In partial fulfillment of the requirements for the degree of the Master of Science in Architecture Dr. James Jones, Chair Dr. Yvan J. Beliveau Prof. Robert Schubert April 2001 Blacksburg, Virginia Keywords: double envelope, double glass façade, intelligent façade, energy efficiency

A Protocol to Determine the Performance of South Facing Double Glass Façade System A Preliminary Study of Active/Passive Double Glass Façade Systems by Shang-Shiou Li Abstract This project proposes a protocol for experimentally determining the performance of a double glass envelope system. As a proof of concept, the protocol was applied to an experimental study of a south-facing, single story double glazed ventilated wall system. Two modular full-scale double glazed window models with naturally or mechanically assisted ventilation were constructed and monitored for a range of weather conditions. The goals of this investigation were to develop and apply the test protocol and to monitor and analyze the thermal performance of these two systems and to improve our understanding of the double façade system. Using this test protocol preliminary results show the average cavity heat removal rate is approximately 25% higher for the active system when compared to the naturally ventilated system. Also, the passive system has a higher temperature difference between the indoor glass surface and the indoor air than the active system. This experimental protocol can be further applied to determine other performance issues of the double envelope system. ii

Acknowledgement I would like to express my deepest thanks to Dr. James Jones, my committee chairman, for his persistent guidance and encouragement over the past two years. I would also like to thank my committee members Professor Robert Schubert and Dr. Yvan Beliveau who provided their expert advices and supports in completing my thesis. Sincere thanks are also expressed to Aaron West and Jimmy Liao for their help in the experimental construction. iii

Table of Contents Abstract. Acknowledgement Table of Contents. List of Figures... List of Tables List of Variables... ii iii iv vi viii ix Chapter One Introduction. 1 1.1 The Double Façade System.. 1 1.2 Natural Ventilation vs. Mechanical Ventilation... 2 1.3 Objectives and Hypotheses... 3 Chapter Two Literature review 5 2.1 Buildings with Double Façade System.... 5 2.1.1 Occidental Chemical Center.... 5 2.1.2 The Lloyd s Building...... 6 2.1.3 Business Promotion Center. 8 2.1.4 RWE Headquarters Tower.. 9 2.1.5 Commerzbank Headquarters... 9 2.2 The Performance of Double Façade System 10 Chapter Three Development of the Test Protocol.. 12 3.1 Fenestration Energy Balance 12 3.1.1 Solar Heat Gain... 12 3.1.2 Double Envelope Heat Removal Rate. 14 3.2 System Design Parameters... 14 3.3 Developing the Test Protocol... 15 3.3.1 Data Measurement... 15 3.3.2 System Operation 18 Chapter Four Application of the Test Protocol... 19 4.1 Experimental Setup.. 19 4.1.1 Test Cells. 19 4.1.2 Windows.. 19 4.1.2.1 Active System.. 20 4.1.2.2 Passive System 20 4.1.3 HVAC Systems... 22 4.1.4 Recording Instruments 22 4.2 Experimental Operation 25 4.2.1 Data Collection 25 4.2.2 Active System Operation..... 27 4.2.3 Passive System Operation... 27 iv

Chapter Five Results and Analyses... 29 5.1 Data Analysis 29 5.2 Determination of Fraction of Transmitted Solar Radiation Removed. 30 5.3 Determine the Temperature Difference Between Indoor Glass Surface and Indoor Air. 31 Chapter Six Conclusions.... 33 6.1 Modification of the Test Protocol. 33 6.2 Application of the Test Protocol and Preliminary Findings. 33 6.3 Discussion of the Preliminary Results.. 35 6.4 Suggestion of Future Studies 37 6.5 Summary.. 37 References 39 Appendix A.. 42 Appendix B.. 43 Appendix C.. 44 Appendix D.. 45 Appendix E.. 49 Appendix F... 53 Appendix G.. 56 Appendix H.. 61 VITA. 66 v

List of Figures 1.1 The heat flow condition in the natural ventilation system: Commerzbank Headquarters 2 1.2 The heat flow condition of the Business Promotion Center 3 2.1 The section view of the Occidental Chemical Center..... 6 2.2 The section view of the Lloyd s Building... 7 2.3 The heat flow condition of the Lloyd s Building.... 7 2.4 The section view of the Business Promotion Center... 8 2.5 The section view of the RWE Headquarters Tower 9 2.6 The section view of the Commerzbank Headquarters 10 3.1 Instantaneous heat balance for sunlit glazing material 12 4.1 Outside the test cells 19 4.2 The section drawing of the test cell. 19 4.3 The test cells 19 4.4 Active system section.. 20 4.5 Passive system section.... 20 4.6 Active system layouts.. 21 4.7 Passive system layouts 21 4.8 Ceiling Fan and Heater and Thermostat.. 22 4.9 The ventilation fans at rear corridor.... 22 4.10 Thermocouples are attached to or suspended from glass surface... 23 4.11 Thermocouples placement in the active system.. 24 4.12 Thermocouples placement in the passive system.... 24 4.13 Anemometer for wind speed and direction measurement... 26 4.14 Vertical and horizontal pyranometer... 26 4.15 Installation of the air flow transducer. 26 4.16 Installation of air flow transducer in ventilation cavity.. 26 4.17 Air outlet slot connects to ducts.. 27 4.18 Returning air intake. 27 4.19 The experimental operation modes. 28 6.1 Percentage of people expressing discomfort due to asymmetric radiation. 35 6.2 Contamination in passive system: dust collection on the air inlet.. 37 6.3 Contamination in passive system: spider net at the air outlet. 37 A1 Regression results for the active system: A- Fhr vs. Ev.. 45 A2 Regression results for the active system: A- Fhr vs. OAT.. 46 A3 Regression results for the active system: A- Fhr vs. WS.... 47 A4 Regression results for the active system: A- Fhr vs. WD... 48 A5 Regression results for the passive system: P- Fhr vs. Ev.... 49 A6 Regression results for the passive system: P- Fhr vs. OAT 50 A7 Regression results for the passive system: P- Fhr vs. WS... 51 A8 Regression results for the passive system: P- Fhr vs. WD.. 52 A9 Regression results for the active system: A- Fhr vs. Ev (Ev > 0.25).. 53 A10 Regression results for the active system: A- Fhr vs. Ev^2 (Ev > 0.25).. 54 A11 Regression results for the passive system: P- Fhr vs. Ev (Ev > 0.25)..... 55 A12 Regression results for the active system: fraction of solar heat removed vs. 5 vi

independent variables.. 58 A13 Regression results for passive system: fraction of heat removed vs. 4 independent variables.. 59 A14 The regression results for active system: upper Tga vs. 4 independent variables... 61 A15 The regression results for active system: lower Tga vs. 4 independent variables... 63 A16 The regression results for passive system: upper Tga vs. 4 independent variables... 64 A17 The regression results for passive system: lower Tga vs. 4 independent variables... 65 vii

List of Tables 3.1 Development of the data measurement... 15 3.2 The optical value for different incident sun angle from The Window 4.1 User s Manual.. 16 4.1 Placement of thermocouples.... 23 5.1 The results for fraction of solar heat removed from cavity. 31 5.2 The fraction of solar heat removed in different cavity air flow rate 31 5.3 The descriptive statistics for the Tga 31 6.1 Frequency Distribution for wind direction.. 36 viii

List of Variables q A Total heat admission through glass E DτD Direct solar radiation transmitted through glass E dτd Diffuse solar radiation transmitted through glass q RCi The rate of heat flux inward by radiation and convection Et Total solar radiation τ Transmittance Ni Heat transfer factor, inward flow fraction α Absorptance U U-value t0 Outdoor (cavity air outlet) temperature ti Indoor (cavity air inlet) temperature F The dimensionless ratio of the solar heat gains to the incident solar raditaion Q Air flow rate required to remove heat, cfm H Heat to be removed, Btu/min c p Specific heat of air, Btu/lb m F (about 0.24) ρ Air density, lb m /ft 3 (about 0.075) A Active double façade system P Passive double façade system Fhr Fraction of cavity solar heat removed Qc Cavity air flow rate OAT Outdoor air temperature Ev Vertical solar radiation WS Wind speed WD Wind direction T Temperature difference between air inlet and outlet ix