Daniel Orifice Fittings and Meter Tubes

Similar documents
Daniel TM Ultrasonic Flow Meters

DANIEL MODEL 1760 BACK PRESSURE PILOT

DANIEL LIQUID TURBINE METER REMOTE MOUNTING BOX

Brooks Mass Flow Meter Model 5863 Mass Flow Controller Model 5853

TERMS AND CONDITIONS OF SALE

User Guide M Rev A 09/15

Agilent 16047D Test Fixture

Agilent 16034E Test Fixture

General Information. Southwest Office Edwards Road, Suite B105 Cerritos, CA (Main Phone)

4 rotary milling table

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Owner s Manual & Safety Instructions

CDM Network Programmer for CCT100x

Aero Tec Models 700 & 750 (115 vac)

Micro Motion, Inc Winchester Circle Boulder, CO (800)

OPERATION AND INSTALLATION MANUAL

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

MAINTENANCE AGREEMENT FOR RSA PRODUCTS ***IMPORTANT***

Installation, Operation & Maintenance Manual

Drag Chain Conveyor Installation and Operation Manual

Installation, Operation & Maintenance Manual

TAYLOR FORGE STAINLESS

Owner s Manual Shelf Lip Accessory

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

USER'S GUIDE TO OPERATION

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

AXIS T91G61 Wall Mount

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Low-Level Design Validation and Testing

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

General Conditions of Business (only applicable to U.S. Users) S.E.A. Science & Engineering Applications Datentechnik GmbH

Lithonia Lighting Terms and Conditions of Sale

Phase One Classic Warranty

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

Odoo Enterprise Subscription Agreement

Ordering & Shipping SECTION IN THIS SECTION: GENERAL INFO ORDERING INFO SHIPPING PAYMENT METHODS RETURN POLICIES

VISE MOUNTED. Model 97359

self level laser Model Set up And Operating Instructions

Adjustable Fused Power Supply

Stainless steel rolling cabinet

Installation. Basic Rack Power Distribution Units AP9560 AP9561

1.5 CONTRACT means the contract for the purchase, sale and rental of the Goods.

DRYWALL DOLLY 900 LB. CAPACITY

Instruction Manual TWO MAN QUAD POD ACCESSORY KIT FSGWSF2017. Compatible with FSGWSF2016, not compatible with other models.

Pneumatic PalletPal Level Loader

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Thermoelectric Cooler

BIN LINER INSTALLATION MANUAL IMPORTANT!

Ecologix Environmental Systems, LLC

RNA and DNA purification

Key-type Selector Switches

92831 TEL: (714) FAX:

Owner s Manual & Safety Instructions

1 TON PORTABLE GANTRY CRANE Model LB. PORTABLE GANTRY CRANE Model 94831

7 PIECE TUBE FLARING KIT

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

TERMS AND CONDITIONS

NVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL

Esco Purchase Order Terms And Conditions

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Universal Trocar Stability Sleeve. Reprocessed Device for Single Use.

Dual Port isolated USB Charger

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

Owner s Manual & Safety Instructions

Dealer & Distributor Account Requirements

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

NucleoMag SEP Magnetic Separator

No part of this manual may be reproduced in any form or by any means, without prior written permission of Darrera.

Carbon Forged Steel Fittings

GENERAL SERVICES ADMINISTRATION Federal Supply Service Authorized Federal Supply Schedule Price List

IF YOU DO NOT AGREE TO THESE TERMS, DO NOT DOWNLOAD, INSTALL OR USE BSS.

Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual

Instruction Manual Blind Bolt Removal Tool Kits. November 10, 2016 HK662

The Netherlands Tel: Tel: +1 (678) Tel: Tel: +61 (0)

Field Economy Unit Instruction Manual

Wash Down Duty Non-Contact Sensor

STEEL PIPE COUPLINGS

RNA and DNA purification

PVC WATER FITTINGS List Price Sheet

Consumer Basic Hardware Services

ViZion Wireless Monitoring System Instructions

Owner s Manual & Safety Instructions

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Dilating Tip Trocar with OPTIVIEW Technology

Instructions for Use Reprocessed Balloon Inflation Devices

Model M120 Mini Temperature/Humidity Meter

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

1(877) Quality Rd Bonita Springs, FL,

Bottom Hinged Flood Barrier Operation & Maintenance Manual

User s Guide RC-3 REMOTE VOLUME CONTROL.

Ergonomic Kneeling Chair

AIR CHAMP PRODUCTS. Micro Clutch and Micro Brake FORM NO. L J-0110

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

SafeNet Authentication Service. Service Provider Role and Scope Guide

Multi-Purpose Scaffolding Instruction Manual

VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

LOAD RAMP 1000 LB. CAPACITY

Pedestrian Flood Door

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

Transcription:

Installation and Operating Instructions P/N 3-9008-002, Rev E November 2017 Daniel Orifice Fittings and Meter Tubes Specific to the Pressure Equipment Directive

Flow Lifecycle Services for Daniel products Location Telephone number Fax number North America/Latin America +1.713.467.6000 +1.713.827.4805 Flow Lifecycle Services for Daniel products +1.713.827.6314 +1.713.827.6312 USA (toll free) +1.888.356.9001 +1.713.827.3380 Asia Pacific (Republic of Singapore) +65.6777.8211 +65.6777.0947.0743 Europe (Stirling Scotland, UK) +44 (0)1786.433400 +44 (0)1786.433401 Middle East Africa (Dubai, UAE) +971 4 8118100 +971 4 8865465 Daniel Measurement and Control, Inc. (Headquarters) 11100 Brittmoore Park Drive Houston, TX 77041 USA http://www.emerson.com/en-us Email Customer Service: Daniel.SystemSales@Emerson.com Customer Support: Daniel.SystemSales@Emerson.com Asia-Pacific: danielap.support@emerson.com Europe: danielema.cst@emerson.com Return Material Authorization (RMA) A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason. Download the RMA form from the Support Services web page by selecting the link below. http://www.emerson.com/en-us/automation/daniel

Signal words and symbols Pay special attention to the following signal words, safety alert symbols and statements: Safety alert symbol This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER! Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING! Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Notice is used to address safety messages or practices not related to personal injury. Important Important is a statement the user needs to know and consider. Tip Tip provides information or suggestions for improved efficiency or best results. Note Note is general by-the-way content not essential to the main flow of information.

Important safety instructions Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions. Because these products are sophisticated technical instruments, it is important that the owner and operation personnel must strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation, operation, and maintenance. Daniel also urges you to integrate this manual into your training and safety program. BE SURE ALL PERSONNEL READ AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL AND ALL NOTICES AND PRODUCT WARNINGS. WARNING! Failure to follow the installation, operation or maintenance instructions for a Daniel product could lead to serious injury or death from explosion or exposure to dangerous substances. To reduce the risk: Comply with all information on the product, in this manual, and in any local and national codes that apply to this product. Do not allow untrained personnel to work with this product. Use Daniel parts and work procedures specified in this manual. Product owners (Purchasers): Use the correct product for the environment and pressures present. See technical data or product specifications for limitations. If you are unsure, discuss your needs with your Daniel representative. Inform and train all personnel in the proper installation, operation, and maintenance of this product. To ensure safe and proper performance, only informed and trained personnel should install, operate, repair and maintain this product. Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.emerson.com/en-us/automation/daniel. Save this instruction manual for future reference. If you resell or transfer this product, it is your responsibility to forward this instruction manual along with the product to the new owner or transferee. ALWAYS READ AND FOLLOW THE INSTALLATION, OPERATIONS, MAINTENANCE AND TROUBLESHOOTING MANUAL(S) AND ALL PRODUCT WARNINGS AND INSTRUCTIONS. Do not use this equipment for any purpose other than its intended service. This may result in property damage and/or serious personal injury or death.

Product operation (Personnel): To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the product. Follow all warnings, cautions, and notices marked on, and supplied with, this product. System should be designed to avoid over pressure conditions or exceeding maximum safe flow rate if meter losses measurement. Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.emerson.com/en-us/automation/daniel. Read and understand all instructions and operating procedures for this product. If you do not understand an instruction, or do not feel comfortable following the instructions, contact your Daniel representative for clarification or assistance. Install this product as specified in the INSTALLATION section of this manual per applicable local and national codes. Follow all instructions during the installation, operation, and maintenance of this product. Connect the product to the appropriate pressure and electrical sources when and where applicable. Never operate meter above the maximum working pressure stated on the nameplate. Ensure that all connections to pressure and electrical sources are secure prior to and during equipment operation. Use only replacement parts specified by Daniel. Unauthorized parts and procedures can affect this product's performance, safety, and invalidate the warranty. Look-a-like substitutions may result in deadly fire, explosion, release of toxic substances or improper operation. Save this instruction manual for future reference.

Notice THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE GOVERNED BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST. WE RESERVE THE RIGHT TO MODIFY OR IMPROVE THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS AT ANY TIME. DANIEL DOES NOT ASSUME RESPONSIBILITY FOR THE SELECTION, USE OR MAINTENANCE OF ANY PRODUCT. RESPONSIBILITY FOR PROPER SELECTION, USE AND MAINTENANCE OF ANY DANIEL PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END-USER. TO THE BEST OF DANIEL'S KNOWLEDGE THE INFORMATION HEREIN IS COMPLETE AND ACCURATE. DANIEL MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN NO EVENT, SHALL DANIEL BE LIABLE FOR ANY INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS, LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL, FUEL AND POWER, AND CLAIMS OF THIRD PARTIES. PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY AND MAY BE TRADEMARKS/ REGISTERED TRADEMARKS OF THESE COMPANIES.

Warranty and Limitations 1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. ( Daniel ) warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and that the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and Services will be performed by trained personnel using proper equipment and instrumentation for the particular Service provided. The foregoing warranties will apply until the expiration of the applicable warranty period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Daniel, whichever period expires first. Consumables and Services are warranted for a period of 90 days from the date of shipment or completion of the Services. Products purchased by Daniel from a third party for resale to Buyer ( Resale Products ) shall carry only the warranty extended by the original manufacturer. Buyer agrees that Daniel has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Daniel thereof in writing during the applicable warranty period, Daniel shall, at its option, correct any errors that are found by Daniel in the firmware or Services or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Daniel to be defective, or refund the purchase price of the defective portion of the Goods/Services. All replacements or repairs necessitated by inadequate maintenance, normal wear and usage, unsuitable power sources or environmental conditions, accident, misuse, improper installation, modification, repair, use of unauthorized replacement parts, storage or handling, or any other cause not the fault of Daniel are not covered by this limited warranty, and shall be at Buyer's expense. Daniel shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by Daniel. All costs of dismantling, reinstallation and freight and the time and expenses of Daniel's personnel and representatives for site travel and diagnosis under this warranty clause shall be borne by Buyer unless accepted in writing by Daniel. Goods repaired and parts replaced by Daniel during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Daniel and can be amended only in a writing signed by Daniel. THE WARRANTIES AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE. THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES. Buyer acknowledges and agrees that corrosion or erosion of materials is not covered by this warranty. 2. LIMITATION OF REMEDY AND LIABILITY: Daniel shall not be liable for damages caused by delay in performance. The remedies of Buyer set forth in this agreement are exclusive. In no event, regardless of the form of the claim or cause of action (whether based in contract, infringement, negligence, strict liability, other tort or otherwise), shall Daniel's liability to Buyer and/or its customers exceed the price to Buyer of the specific goods manufactured or services provided by Daniel giving rise to the claim or cause of action. Buyer agrees that in no event shall Daniel's liability to Buyer and/or its customers extend to include incidental, consequential or punitive damages. The term consequential damages shall include, but not be limited to, loss of anticipated profits, revenue or use and costs incurred including without limitation for capital, fuel and power, and claims of Buyer's customers.

Contents Contents Part I Plan Chapter 1 Introduction... 3 1.1 Purpose of this manual... 3 1.2 Scope... 3 Part II Install Chapter 2 Installation procedure... 7 2.1 Installation... 7 2.2 Compliance and requirements... 7 Installation and Operating Instructions i

Contents ii Orifice Fittings Instructions for PED

Plan Part I Plan Installation and Operating Instructions 1

Plan 2 Orifice Fittings Instructions for PED

Introduction 1 Introduction Topics covered in this chapter: Purpose of this manual Scope 1.1 Purpose of this manual This document shall identify specific installation and operation instructions necessary to ensure compliance with the Essential Safety Requirements (ESR) of the European Economic Area Pressure Equipment Directive (PED) 2014/68/EU and the UK Pressure Equipment Regulations 1999 (SI 1999/2001). 1.2 Scope This document applies to Daniel Orifice Fittings and Orifice Meter Tubes designed by Daniel Measurement and Control, Inc. (Daniel) of Houston, Texas, USA., and manufactured by Daniel or an authorized agent. Installation and Operating Instructions 3

Introduction 4 Orifice Fittings Instructions for PED

Install Part II Install Installation and Operating Instructions 5

Install 6 Orifice Fittings Instructions for PED

Installation procedure 2 Installation procedure Topics covered in this chapter: Installation Compliance and requirements 2.1 Installation The end user of the equipment shall be responsible for the following actions during the installation of the equipment to ensure compliance with the Essential Safety Requirements of the Directive and Regulations quoted in Section 1.1 of this document. Relevant parts of the directive ESR are listed below. 2.2 Compliance and requirements Table 2-1: Compliance and requirements information PED ESR Ref ESR requirement Compliance requirement 2.3 Provisions to ensure safe handling and operation The method of operation specified for pressure equipment shall be such as to preclude any reasonably foreseen risk in operation of the equipment. Particular attention must be paid, where appropriate, to the following. Closures and opening During removal and replacement of the orifice carrier the operator must comply strictly with the instructions given in the unpacking, installing, operating and maintaining manual supplied with each fitting.these instructions are also given on the operating instruction plate attached to each fitting. It is the end user s responsibility to ensure that all operatives are aware of the instructions and sufficiently trained to carry them out. Installation and Operating Instructions 7

Installation procedure Table 2-1: Compliance and requirements information (continued) PED ESR Ref ESR requirement Compliance requirement Devices to prevent physical access while pressure or a vacuum exists Surface temperatur Decomposition of unstable fluids 2.4 Means of examination Pressure equipment shall be designed and constructed so that all necessary examinations to ensure safety can be carried out. 2.5 Means of draining and venting To avoid harmful effects such as water hammer, vacuum collapse, corrosion and uncontrolled chemical reactions 2.6 Corrosion or other chemical attack The end user shall ensure that the orifice fittings and any associted meter tubes are installed in a properly designed system with access limitation in place if required. It is the responsibility of the end user to assess the expected surface temperature in service, and if necessary, take the necessary precautions to avoid personnel coming into contact with the equipment. It is not envisaged that, for the designed service, the equipment shall come into contact with unstable fluids. However, the end user should assess the risk and take any steps considered necessary. The Daniel Orifice Fittings and associated meter tubes are designed so that all critical parts can be examined without the need to remove the unit from service. The end user should refer to the operations and maintenance instructions supplied with each fitting. It is not expected that the process medium for which the equipment is designed will give rise to severe corrosion/erosion problems. It is the end user's responsibility to monitor any change in the process medium that may cause concern. It is the responsibility of the end user to ensure that the equipment is installed in a well-designed piping system to avoid such hazards. It is not expected that the process medium for which the equipment is designed will give rise to severe corrosion problems. It is the end user's responsibility to monitor any change in the process medium that may cause concern. 8 Orifice Fittings Instructions for PED

Installation procedure Table 2-1: Compliance and requirements information (continued) PED ESR Ref ESR requirement Compliance requirement 2.7 Wear It is not expected that the use of the fitting and any associated meter tube for fluid metering will give rise to any abnormal wear problems. It is the responsibility of the end user to install any necessary filtration upstream of the fitting to maintain the condition of the process medium. 2.10 Protection against exceeding the allowable limits of the pressure equipment. The fitting and any associated meter tube must be installed in a well-designed piping system with adequate protection against excessive pressure. 2.12 External fire The fitting and any associated meter tube have no special accessories for fire damage limitation. It is the responsibility of the end user to provide adequate fire-fighting facilities on site. 7.3 Pressure limiting devices, particularly for pressure vessels The fitting and any associated meter tube are not a pressure vessel and has no integral pressure limiting devices. It is the responsibility of the end user to ensure that the fitting and any associated meter tube are installed in a welldesigned system so that momentary pressure surges are limited to under 10% of the fitting's and any associated meter tube's maximum allowable pressure. Installation and Operating Instructions 9

Installation procedure 10 Orifice Fittings Instructions for PED

Installation procedure Installation and Operating Instructions 11

P/N 3-9008-002 Rev E 2017 Emerson Process Management Daniel Measurement and Control, Inc. North America / Latin America: Headquarters USA - Houston, Texas T +1.713.467.6000 USA Toll Free 1.888.FLOW.001 www.emersonprocess.com/daniel Europe: Stirling, Scotland, UK T +44.1786.433400 Middle East, Africa: Dubai, UAE T +971.4.811.8100 Asia Pacific: Singapore T +65.6777.8211 2017 Daniel Measurement and Control, Inc. All rights reserved. Unauthorized duplication in whole or part is prohibited. Printed in the USA. Daniel Measurement and Control, Inc. ("Daniel") is an Emerson Process Management business unit. The Daniel name and logo are trademarks of Daniel Industries, Inc. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other trademarks are the property of their respective companies.