ChemoLock. Setting a Whole New Standard for Hazardous Drug Safety. Don t you love it when everything just clicks? Introducing

Similar documents
Diana. Automated Drug Compounding System. Automated sterile compounding for the accurate, safe, and efficient preparation of hazardous drugs.

ChemoLock Needlefree Closed System Transfer Device

Automated compounding for intravenous chemotherapy

BD PhaSeal System. Product Catalog

Study Summary. Results: All tested media-filled vials were negative for growth of any microorganisms.

Completing. By the end of this chapter, you will be able to: Introduction. Chapter 16

Sterile Compounding elearning Course Curriculum 28 lessons with 33 hours of CE. Fundamentals of Sterile Compounding (8 lessons/8 hours CE)

Two part study simulated preparation and administration manipulations to determine containment of liquids, aerosols and vapors.

When it comes to managing the hazardous waste in your hospital, what you don t know you don t know can hurt you.

USP <800> A practical approach to compliance. Ryan W. Naseman, PharmD, MS, BCPS Michael Storey, PharmD, MS, BCPS

Insulin Syringes ACCU-SHOT TM ACCU-SHOT U40 & U100. (with Ultra Thin & Short Needle) Sizes. Colour Code of Top Cap ml U G 6 mm Red

Space Infusion System. Synchronized Intelligence Infusion Platform. Integrated Pumps

Sterile Compounding elearning Course Curriculum 28 lessons with 33 hours of CE. Fundamentals of Sterile Compounding (8 lessons/8 hours CE)

SapphirePlus TM. The Small, Simple Solution for Complex Healthcare. Infusion System

HAZARDOUS MATERIALS 7/7/2016 OR THE RIGHT-TO-KNOW HAZARD COMMUNICATION STANDARD (HCS) DISCLAIMER

with Nemera s extensive experience in developing and manufacturing parenteral drug delivery devices

DIFFERENTIATION WITHOUT DISRUPTION

Compounding Solutions. An advanced system for multi-ingredient solution compounding

Pharmacy Compounding: Infection Prevention

COMPLETE COMPLIANCE CHECKLIST

Why change is inevitable in aseptic manufacturing?

Compounding Questions and Answers

UNIVERSITY OF TOLEDO HEALTH SCIENCE CAMPUS

How will you take control of your sterile compounding strategy? i.v.station

Polychlorinated Biphenyls (PCBs)

INNOVATIVE PLASTIC CONTAINERS

LUNCH AND LEARN. October 14, CE Activity Information & Accreditation

THE SAFE DISPOSAL OF CLINICAL/DOMESTIC WASTE

FDA s Guidance for Industry

PhaSeal Evidence. A summary of the published evidence of the effectiveness of the PhaSeal closed-system drug transfer device

Eliminating Infusion Confusion

Product Catalog (US) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

HardyVal TM CSP MEDIUM-RISK LEVEL MEDIA-FILL CHALLENGE KITS

Guidelines for the use of blood warming devices(aabb) Reference: 2002 AABB

Pharmaceutical Waste Compliance Program Clinician Educators and Managers In-Service

LEARN. about. Please see Important Safety Information on pages 3-5 and enclosed full Prescribing Information.

MEDICAL WASTE MANAGEMENT STUDY NOTES

Pharmacy. Medication. Checks

Objectives Discuss the importance of proper data collection. Identify the types of data collected for clinical trials. List potential source documents

Welch Allyn Connex. Electronic Vitals Documentation (EVD) System

USP <797> Compliance Common Challenges and Potential Solutions

WEEKLY SAFETY MEETING All Euramax Subsidiaries. Safety Meeting Contents FLAMMABLE LIQUID SAFETY. Meeting Notice. Leaders Guide.

The safer system of sharps segregation

ICU Medical, Inc. Investor Presentation (NASDAQ:ICUI) March 2018

SPECIAL WASTE CONTAINERS

Next Review Date: Oct 2017 SWP Reference Number: Version: V3 Version Issue Date: Oct 2016

Hot Topics in Drug Product Process Validation: A Reviewer s Perspective

GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR

Microsphere Brachytherapy Sources and Devices

TEMPLE UNIVERSITY CEMS Chemical Environmental Management System

ANNEX 5 MANUFACTURE OF IMMUNOLOGICAL VETERINARY MEDICINAL PRODUCTS

Today, we re going to talk about the Occupational Safety and Health Administration s, or OSHA s, Hazard Communication Standard, or worker right to

Biomedical Waste Handling and Disposal

Product Catalog (Canada) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

BIOMEDICAL WASTE FACILITY INSPECTION REPORT* Facility name: Permit #: Date of Inspection:

Chemical Reactions. Lab. FCJJ 11 - Fuel Cell Car Science Kit. Next Generation Science Standards. Initial Prep Time. Lesson Time. Assembly Requirements

Slide 1. Welcome to the on-line training course for Waste Management!

Managing Hazardous Chemical Waste

BIP Central Venous Catheter

One such problem is blood residual inside the channels of a robotic arm.

BD Cato. medication workflow solutions. Elevating the standard of IV compounding

IV solutions that fit

MATERIAL SAFETY DATA SHEET General Finishes Corporation. SECTION 2: Composition/Information on Ingredients

SOP BIO-006 USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE

TITLE: Research Pharmacy Standard Policy SOP #: INV-100 Page: 1 of 5 Effective Date: 8/31/17

Arthrex Angel TM System. Indication-specific PRP and PRF gel preparations

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

Handling of high potency drugs: process and containment

MATERIAL SAFETY DATA SHEET 1. Product and Company Identification

Safe handling of cytotoxic drugs and cytotoxic waste ETLog GmbH Brunnenstraße Berlin Germany

Pain Full Drug Shortages

Does this topic relate to the work the crew is doing? If not, choose another topic.

TMElectronics, Inc. Specialists in Leak, Flow and Package Testers

Material Safety Data Sheet

Spill Response & Reporting Plan

Health Care Waste Management - To Reduce the Burden of Disease, Health- Care Waste Needs Sound Management, Including Alternatives to Incineration

NO 2 Gas Sterilization and Decontamination: Keeping Pace, from Start to Finish

EG-MC-125 EG-MC-850 EG-MC-350

Combination Products Workshop: CGMP and PMSR Requirements. GMP by the Sea August 28, Mark D. Kramer Regulatory Strategies, Inc.

ASTM D-4236 standard practice for labeling art materials for acute and chronic adverse health hazards.

USP CHAPTER <797> INTRODUCTION RISK LEVELS

THE CUTTING AMPOULE DESIGN INOVATION TO DEVELOP SAFETY AND HELATH PATIENT

A Profile of PVA Capabilities with Remote Time Location Systems (RTLS) Profile of PVA Capabilities

MATERIAL SAFETY DATA SHEET General Finishes Corporation. SECTION 2: Composition/Information on Ingredients

You are required to complete this course with a passing score of 85% or higher if you:

Standard Operating Procedure Title: Good laboratory practices (GLP) for microbiology and chemistry laboratories

Contact Information: Laboratory Supervisor: Denise Kind Laboratory Manager: Mat Ashby

HEALTHCARE ITEM INTELLIGENCE IMPROVE PATIENT OUTCOMES, INCREASE EFFICIENCY & DECREASE COST

Nuclear Power Plant Incidents

ASTM D-4236 standard practice for labeling art materials for acute and chronic adverse health hazards.

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes

GE Healthcare. OEC 9800 Plus. A Classic Choice

SCHOTT Pharmaceutical Packaging. Dedicated to quality pharmaceutical packaging

Material Safety Data Sheet according 91/155/EEC Product Name : Edge-Stick 8 cm Kö 135 Date: Revision date:

GPS III Platelet Separation System. Leadership through Technology

6/19/2015. This lecture provides an overview of some of the safety precautions you can practice in order to create a safe lab environment.

Transcription:

Introducing ChemoLock Needlefree Closed System Transfer Device The first and only needlefree CSTD to receive FDA 510(k) clearance for both pharmacy (ONB) and patient administration (FPA) applications. Setting a Whole New Standard for Hazardous Drug Safety > > Prevents the escape of hazardous drug or vapor concentrations outside the system > > Blocks the transfer of bacteria and other environmental contaminants into the system > > Eliminates needlestick injuries while keeping patients and clinicians safe from hazardous drug exposure Don t you love it when everything just clicks?

One Click Is All It Takes to minimize exposure to hazardous drugs and maintain the sterility of the patient mix. With the ChemoLock needlefree closed system transfer device (CSTD), it has never been easier to keep yourself safe from exposure to hazardous drugs. Treating cancer patients takes compassion it shouldn t take a toll on your health. But the fact is, while chemotherapy is the backbone of medical oncology, these powerful medications along with many others are extremely toxic to the clinicians who handle them. Prolonged exposure to hazardous drug vapors, drips, or spills has been shown to lead to hair loss, skin rashes, infertility, miscarriages, birth defects, and even forms of cancer. It doesn t have to be that way. The system s automatic self-sealing technology requires no cumbersome assembly, and the bonded components cannot be accidentally disconnected. In response to the well-documented risks associated with handling hazardous drugs, ICU Medical has developed ChemoLock to create a needlefree mechanically and microbiologically closed system for the safe handling of hazardous drugs. ChemoLock s intuitive and easy-to-use system locks with an audible click, ensuring a safe and secure connection has been made to minimize exposure to hazardous drugs and protect the patient preparation from external contamination. The ChemoLock system s easy-to-use needlefree click to lock technology maintains a closed system throughout the entire safe handling process to keep you in compliance with industry safe handling guidelines. Safely Prepare Stay safe and in compliance with recommended guidelines during the preparation of hazardous drugs thanks to the ChemoLock system s mechanically and microbiologically closed needlefree system. Safely Transport The ChemoLock system prevents leaks and spills during the transportation of hazardous drugs from pharmacy to nursing, while also protecting the sterility of the patient preparation.

Safely Administer The easy-to-use ChemoLock system helps you keep patients and clinicians safe without having to change standard nursing protocols. Safely Dispose The ChemoLock system remains mechanically and microbiologically closed all the way through disposal, to help eliminate potential drug exposure to you or the environment.

ChemoLock helps speed preparation times by eliminating the need to assemble multiple components. The system snaps together with an audible click to ensure a safe and secure connection. Every time. To maximize patient safety, ChemoLock maintains the sterility of the drug during transport from pharmacy to nursing.

Safe Handling Starts in the Pharmacy. ChemoLock helps you minimize hazardous drug exposure and maximize medication safety. With the ChemoLock system s breakthrough click to lock technology, you don t have to sacrifice efficiency for patient and clinician safety. In today s fast-paced pharmacy environment, every second counts and every preparation has to be right. ChemoLock can help. That s because ChemoLock s simple and intuitive needlefree design allows the system to be accessed and sealed with a single motion, reducing the potential for insecure or unsafe connections that may jeopardize clinician and patient safety. The needlefree, mechanically and microbiologically closed system fits seamlessly into your workflow to help you minimize exposure to hazardous medications during reconstitution and preparation, while simultaneously preventing any outside environmental contaminants from getting into the mix. ChemoLock is the first and only needlefree closed system transfer device to receive FDA 510(k) clearance under the ONB product code, keeping you and the drugs you mix safer. The ChemoLock product line includes an assortment of bag spikes, vial adapters, and other components designed to meet the specific needs of your pharmacy, including: Genie Closed Vial Spike (CL-77) ChemoLock Bag Spike (CL-10) Spinning ChemoLock (CL2000s)

Safely Administer Hazardous Drugs to Your Patients. ChemoLock is the simple and intuitive way to ensure compliance and improve patient and nurse safety. With the ChemoLock system, there is no complex assembly required at the point of care for the system to remain closed throughout administration. Keeping safe while administering hazardous drugs doesn t need to be complicated. The ChemoLock system s one-step, click to lock design ensures medication sterility, while eliminating the possibility of accidental disconnects that may result in dangerous exposure to hazardous drugs and increase the risk of central line associated bloodstream infections (CLABSI). This makes it easier to ensure compliance with safe handling guidelines while improving both nurse and patient safety in the process. ChemoLock is the first and only needlefree closed system transfer device to receive FDA 510(k) clearance under the FPA product code for patient administration, keeping you in compliance with needlefree policies. An audible click lets you know you ve made a safe and secure connection between the administration device and the patient line. The ChemoLock system s bonded components and locking mechanism help eliminate unsafe disconnects.

With the ChemoLock system s intuitive design, you can focus on caring for patients rather than assembling complex components. As a completely needlefree technology, the ChemoLock system ensures compliance with your facility s needlefree policies.

It s a Snap to Choose the ChemoLock Components that are Right for You. Since all ChemoLock components contain passive self-sealing mechanisms that cannot be deactivated by the user and remain protective from preparation through to disposal, it is easy for you to choose the combination of components that best meets your needs. Here are a few examples to choose from: Closed Vial Access Devices Bag Spikes Closed Male Injector Genie Closed Vial Spike (CL-77) Allows access to vials having 20 mm closures and automatically equalizes vial pressure with internal balloon ChemoLock Bag Spike (CL-10) For use on any solution container Spinning ChemoLock (CL2000S) For use on a syringe or IV tubing Administration Sets and Components Locking Universal Vented Vial Access Device (CL-70) Locking arms with large vent offers better flow rates and reliability Bag Spike with ChemoLock Additive Port and Dry Spike (CL-12) Dedicated lumen for direct access to solution bag 30 Secondary Set with Integrated ChemoLock Drip Chamber and Bonded Spinning ChemoLock (CL3511) 13mm Closed Vial Access Device (CL-62) Allows for access to small vials with 13mm closures Bag Spike with ChemoLock Additive Port (CL-13) For use on any solution container ChemoLock Port (CL2100) For use on patient IV line 2014 ICU Medical Inc. M1-1450 Rev. 02 800.824.7890 www.icumed.com