Intumescent Pipewrap Roll

Similar documents
FIREPRO FIRESTOP PIPE COLLARS. Firestop solution for plastic pipework penetrations

Ductslab and Ductwrap

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

HP Partial Fill. Robust, long-lasting protection

ROCKWOOL Tapered Roofing

Technical Data Sheet. Astro HPE Sealant. UIC of product-type: AFHPE

PRODUCT TECHNICAL DATA SHEET WEATHER PRO TM INSULATION JACKET

Builders Merchants Price List 2017

Technical Data Sheet. Hilti Firestop cable collar CFS-CC. European technical approval ETA N o 13 / Issue 10 / 2013

Firestop and Fire Protection Systems

Section 11 FIRE STOPPING

DECLARATION OF PERFORMANCE

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

Marine Fire Wrap General Installation Instructions Cable Penetrations through A0-A60 and B0-B30 Bulkheads and Decks

SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

Republic of Ireland Price List Prices effective from 1st January 2018

FIREPRO DELIVERING TOTAL FIRE PROTECTION

Assembly Instruction. FLAMRO Variant N II A / N II KS

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

K-FLEX K-FONIK INDUSTRIAL

FIRE STOP PRODUCTS. As innovative manufacturers, we are continuously adding to our range, meeting the needs of a highly demanding market.

For inhibiting the spread of fire and smoke in concealed spaces

European Technical Assessment. ETA-16/0320 of Member of. General part

CERTIFICATE OF APPROVAL No CF 517 FSI LIMITED

FIRESTOPPING. The Hidden Solution that Compartmentalizes. Vic Wootton A/T Firestop and Fireproofing Solutions

European Technical Assessment ETA-16/0952 of 06/01/2017

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

FIRESTOP 101: An Introduction to Firestopping

Hilti Firestop Single Board Seal Hilti Firestop Single Board Seal. Hilti AG Feldkircherstrasse Schaan Liechtenstein

LABORATORY MEASUREMENTS OF THE SOUND REDUCTION INDEX ROCKWOOL ABLATIVE COATED BATTS

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

United Kingdom Price List Prices effective from 1st March 2018

HILTI CP 601S Elastomeric Firestop Sealant

U L - E U C E R T I F I C A T E

European Technical Assessment. ETA-11/0372 of Member of. General part

BICSI March 19 th, 2009 Canadian Regional Meeting NBCC Moncton, New Brunswick. Firestop, it s not Magic It s understanding!

SECTION HVAC INSULATION

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED

Assembly Instruction. Fire protection collars

Property of Cooks Plumbing Supplies

Product Information High Performance Building Dow Corning Firestop 700 Silicone Sealant

St. Monica Food Pantry

CERTIFICATE OF APPROVAL No CF 513 FSI LIMITED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

SOUND SOLUTIONS TO MEET THE APPROVED DOCUMENT E (2003 EDITION) August 2008

ROCKWOOL Blanket (and Batt) Insulation Section Master Guide Specification Page 1 Jan 2017

RECOMMENDED APPLICATION INSTRUCTIONS FIRE RETARDANT COATINGS FOR CABLES AND FIRE RESISTANT BARRIERS FOR SERVICE PENETRATION SEALS

CERTIFICATE OF APPROVAL No CF 355

The extra strong, extra durable, sound resistant system that you can direct fix to

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Applications USES FIRESTOP SYSTEM. Fire Barrier Caulk. Smoke and Acoustic Sealant. Moldable Firestop Putty. Putty Pads.

CERTIFICATE OF APPROVAL No CF 816 BIP GMBH

PASSIVE FIRE PROTECTION PRODUCTS

European Technical Assessment ETA-17/0741 of 29/08/2017

UL Design System HW-D-1012 continued

FIRESTOP SUBMITTAL PACKAGE

Kent, DA1 4FT. appended hereto:

CLASSIFICATION OF FIRE RESISTANCE IN ACCORDANCE WITH BS EN : A1:2009

DECEMBER Phone: Fax:

SUBMITTAL INDEX. Product Datasheets: Product Approvals:

PITCHED ROOF SOLUTIONS

CERTIFICATE OF APPROVAL No CF 5363 NULLIFIRE LIMITED

EDITION: EXPORT - PUBLISHED: 11/2013 NEW PRODUCT NAMES. ProRox. Product catalogue. Industrial insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Innovative Fire Protection Systems ETA CATALOG

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

RMF Intercell. NBS Specification 2013 K41

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

L'ISOLANTE K-FLEX. LNG applications Manual

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

European Technical Assessment. ETA-12/0101 of Member of. General part

REGULATORY INFORMATION REPORT

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

EZ-PATH FIRE STOPPING DEVICES

External Thermal Insulation Composite System Insulation below ground level

HILTI CP 606 Flexible Firestop Sealant

Luka Quality Assurance Manual (Eng)

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

Assembly Instruction. FLAMRO KSL Combi seal according to ETA-16/0320. Content

3M Fire Protection Products. Confidence. Even Under Fire. Principal Products Ltd I Ph: I

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

SECTION THROUGH-PENETRATION FIRESTOPPING

Light-Metal Roof Edge, Raised

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

FIRESTOP TECHNICAL PACK TEL: (888) 721-SEAL (7325) FAX: (888) 921-SEAL (7325)

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

3M CS-195+ Composite Sheet Product Description

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

Tehnical Data Sheet Astro HS FM Compound. UIC of product-type: HSFMC CPR-JA5013 ETA-14/0047. ETAG 026-Part 1 ETAG 026-Part 2

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

CERTIFICATE OF APPROVAL No CF 663 HILTI AG

The Passive Fire Protection Handbook

Construction. Sikadur -Combiflex SG System High performance joint sealing system. Positioning. Product Data

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

Pipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

Transcription:

FIRESTOPPING December 2016 Intumescent Pipewrap Roll ROCKWOOL FirePro Intumescent Pipewrap Roll offers a simple and more economical alternative to Firestop Collars and avoids the need to carry a wide range of individually sized Intumescent pipe wraps. Wrap on a roll is suitable for firestopping a variety of combustible pipes and metallic pipes insulated with combustible insulation in both walls and floors.

ROCKWOOL FirePro Intumescent Pipewrap Roll comprises an intumescent material made from elastomeric thermoplastic polymers combined with active components that provide a high volume expansion and pressure seal in the event of a fire. Description ROCKWOOL FirePro Intumescent Pipewrap Roll is supplied on 25m roll. The product is 40mm wide and 2mm thick, with integral adhesive tape for securing around the pipe. Depending on the service to be protected and the fire resistance required, multiple layers may be required, the exact number and positioning of the product is detailed in the performance section of this data sheet. Advantages: Simple to Install No mechanical fixings required Water resistant Maintenance free Supplied as a 25m long roll in box dispenser Available to suit pipes up to 200mm o.d. Comprehensively tested Available from stock Handling / Installation The product is intended to be wrapped around the outside diameter of combustible pipework or the outside diameter of insulation on pipework and is secured by means of the integral self-adhesive strip. 1) check that pipe surface and substrate are clean and clear of any debris. 2) Install the correct number s for the service type and ensure the correct number of layers as detailed in the performance section of this data sheet. 3) Install the wrap into the wall or floor recessed by 5mm from the face of the wall or floor. 4) Fill the annular space with Rockwool FirePro Acoustic Intumescent Sealant to seal off the 5mm gap to the edge of the substrate. 5) maintain a record of the installation. Under fire conditions, the intumescent material expands against the structure and fills the void left by the burnt out plastic and/or insulation. Maintenance During normal use, no maintenance is required. Specification Install ROCKWOOL FirePro Intumescent Pipewrap Roll to provide up to 4 hours fire protection to all plastic pipework and insulated pipes where they pass through fire rated walls and floors. Installation to be fully in accordance with manufacturer s instructions. 2

Table 1 - Pipes through flexible wall (Ø) and / Floor Supports Capping Classification PVC 200 9.6 N/A N/A PP 200 18.2 N/A N/A E120, PE 200 18.4 N/A N/A PE 50 4.6 N/A N/A PE 200 18.4 N/A N/A 3

Table 2 - Pipes in Rigid Floor (Ø) and /Floor Supports Capping Classification PVC 200 9.6 N/A N/A 150mm PP 50 2.9 N/A N/A 150mm PP 200 18.2 N/A N/A 150mm E120, PE 200 11.4 N/A N/A 150mm PVC 200 9.6 N/A N/A 150mm PVC 200 9.6 N/A N/A 150mm E240, EI180 PVC 50 3.7 N/A N/A 150mm E240, EI180 PVC 50 2.4 N/A N/A 150mm PP 200 18.2 N/A N/A 150mm PP 50 6.9 N/A N/A 150mm PP 200 4.9 N/A N/A 150mm PE 200 18.2 N/A N/A 150mm 4

Table 3 - Pipes in using pattress installation of 50mm FirePro ACB (Ø) and / Floor Supports Capping Classification 159 14.2 Elastomeric E120, 108 14.2 Phenolic 25-40 42 1 Phenolic 25-40 108 14.2 Phenolic 40 42 1 Elastomeric 159 14.2 Elastomeric 25 PVC 200 9.6 N/A N/A PP 200 18.2 N/A N/A PE 200 18.4 N/A N/A 42 1 Mineral wool 159 14.2 Mineral wool 108 14.2 Mineral wool 5

Table 4 - Pipes in installed in Double Layer 50mm FirePro ACB (Ø) and /Floor Supports Capping Classification 159 14.2 Elastomeric 108 14.2 Phenolic 25-40 E120, 42 1 Elastomeric E120, 42 1 Phenolic 25-40 E120, PVC 110 6.6 Phenolic 20-25 PVC 110 6.6 Elastomeric 159 14.2 Mineral wool Table 5 - Wrap configuration by size Pipe O.D. No. of of Wrap Total wrap thickness 40 1 2 55 2 4 63 2 4 75 2 4 82 2 4 90 3 6 110 3 6 125 4 8 160 4 8 200 5 10 Table 6 - Physical Properties Width Length Density Volume Expansion at 300 c Shelf Life 40mm 25m 2mm 1.3Kg/m³ 25 times 60 months Key to tables ACB = Ablative Coated Batt = Continuous Sustained Φ = applied to both faces of seal Ϯ = applied to upper face only = Upcapped / Capped ROCKWOOL Limited Pencoed Bridgend CF35 6NY info rockwool.co.uk www.rockwool.co.uk ROCKWOOL Limited reserves the right to alter or amend the specification of products without notice as our policy is one of constant improvement. The information contained in this data sheet is believed to be correct at the date of publication. Whilst ROCKWOOL will endeavour to keep its publications up to date,readers will appreciate that between publications there may be pertinent changes in the law, or other developments affecting the accuracy of the information contained in this data sheet. The above applications do not necessarily represent an exhaustive list of applications for FIREPRO Intumescent Pipewrap Roll. ROCKWOOL Limited does not accept responsibility for the consequences of using FIREPRO Intumescent Pipewrap Roll in applications different from those described within this data sheet. Expert advice should be sought where such different applications are contemplated, or where the extent of any listed application is in doubt. 6