Single cell isolating for downstream DNA and RNA analysis

Similar documents
DEPArray Technology. Sorting and Recovery of Rare Cells

FemINDICAtor qpcr Plant Gender Detection Kit on the BIO-RAD CFX96 Touch Real- Time PCR Detection System Page 1 of 11

Tissue Microarray Catalog

LiquidBiopsy LIQUIDBIOPSY. Automated Rare Template Isolation Platform

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

Using ULS24 CMOS Bio-imager as a Readout Sensor for Chemiluminescence Immunoassay and DNA Hybridization Assay

Real-time RT-PCR Protocol for the Detection of A(H7N9) Influenza Virus

QIAGEN GeneRead QIAact Panel Cleanup Kit Handbook

QIAcube Pure Efficiency

Ampli1 WGA Kit. Whole Genome Amplification for Single Cells. USER MANUAL y Version 01 Content version: July I WG R01 50 reactions

FemINDICAtor qpcr Plant Gender Detection Kit on the Agilent AriaMX Real-Time PCR Detection System Page 1 of 10

scgem Workflow Experimental Design Single cell DNA methylation primer design

QIAcube HT Your Purification Expert

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Innovations To Meet Your Needs

RealLine Food Kit Turkey Detect

Axygen AxyPrep Magnetic Bead Purification Kits. A Corning Brand

Welcome to the NGS webinar series

PreAnalytiX Supplementary Protocol

QIAsymphony SP Protocol Sheet

Illumina TruSeq RNA Access Library Prep Kit Automated on the Biomek FX P Dual-Hybrid Liquid Handler

Georgia Bureau of Investigation - Division of Forensic Sciences DNA Procedures Manual DNA QUANTIFICATION USING QUANTIFILER HUMAN / Y HUMAN MALE KIT

QIAGEN Supplementary Protocol

Multiplex Assay Design

NRAS Codon 61 Mutation Analysis Reagents

Accurate and Automated cell confluence assessment in microplates

QIAGEN Whole Genome Amplification REPLI-g Eliminating Sample Limitations, Potential Use for Reference Material

Axiom 2.0 Assay Mini 96-Array Format

DNA Workflow. Marine Biological Laboratory. Mark Bratz Applications Scientist, Promega Corporation. August 2016

Varicella Zoster Virus Real Time PCR Kit

PERFORMANCE MADE EASY REAL-TIME PCR

PathogINDICAtor qpcr Microbial Detection Assay on the AriaMX Real-Time PCR System Optional Decontamination Step Page 1 of 12.

Using the C 1 Single-Cell Auto Prep System to Capture Cells from Cell Culture and Perform Preamplification Using TaqMan Assays.

AmoyDx TM JAK2 V617F Mutation Detection Kit

AmoyDx JAK2 Mutation Detection Kit

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

Performance characteristics of the High Sensitivity DNA kit for the Agilent 2100 Bioanalyzer

NRAS Mutation Analysis Reagents (Codons 12 and 13)

Systematic Analysis of single cells by PCR

Entry Level Assessment Blueprint Biotechnology

Standard Operating Procedure

Agilent s Mx3000P and Mx3005P

Introducing: 3Zomy Aneuploidity Test

Enteroinvasive E. Coil(EIEC) Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Implementation of Automated Sample Quality Control in Whole Exome Sequencing

AmoyDx TM PIK3CA Five Mutations Detection Kit

ab Plant Chromatin Extraction Kit

Before You Begin. Calibration Protocols

Taura Syndrome Virus (TSV) RT-PCR Kit

AmoyDx JAK2 Mutation Detection Kit

QuantiTect Primer Assay Handbook

Single Cell 3 Reagent Kits v2 Quick Reference Cards

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Transfusion-transmitted Virus(TTV) Real Time PCR Kit

TIME IT S PRIME. chemagic TM Prime TM instrument Streamlined Walk-away Automation. For all Human Sample Materials. Primary Sample Handling

Tamiflu resistance detection kit

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

SOLiD Total RNA-Seq Kit SOLiD RNA Barcoding Kit

Code: IDK-006 Ver: 1 MTHFR A1298C. Detection system of the A1298C mutation in the human Methylen-tetraydrofolate reductase gene. Reg.

PAXgene Blood DNA PAXgene Blood DNA Tube (IVD) for clinical use PAXgene Blood DNA System (RUO) for research use. Explore more at

Scaling Up NGS Sample Preparation: Automation and Lab Preparation. Alicia Burt Sr. Product Manager

NEBNext. Multiplex Oligos for Illumina (Dual Index Primers Set 2)

NanoString Assay Sample Type Assay Input Amount Required Sample Amount/Concentration Total RNA 100ng no less than 150ng, normalized to 20ng/µl

Library Loading Bead Kit (EXP-LLB001) Agencourt AMPure XP beads Vortex mixer. Freshly prepared 70% ethanol in nucleasefree

NanoString Sample Submission Guidelines

Alt-R CRISPR-Cpf1 System:

Applied Biosystems TaqMan Array Microfluidic Cards

High-Resolution Oligonucleotide- Based acgh Analysis of Single Cells in Under 24 Hours

Symphony Genomics Workflow Management System Managing, Integrating, and Delivering Your NGS Data and Results

One Step SYBR PrimeScript RT-PCR Kit II (Perfect Real Time)

1D^2 Sequencing Kit (SQK-LSK308) Pipettes P2, P10, P20, P100, P200, P1000 Freshly prepared 70% ethanol in nucleasefree

Cellular UV-Induced DNA Damage Staining Kit (CPD)

MHC Region. MHC expression: Class I: All nucleated cells and platelets Class II: Antigen presenting cells

Freedom EVO - HSM Workstation

Protocol for DNA and RNA Isolation from the Same FFPE Sample

Isolation of Viral RNA, Viral DNA and Bacterial DNA from Animal Samples

SNP GENOTYPING WITH iplex REAGENTS AND THE MASSARRAY SYSTEM

Precision MULTIPLEX qpcr Master Mix. Instructions for use of Primerdesign Precision MULTIPLEX Master Mix for real-time PCR

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

Alt-R CRISPR-Cas9 system:

36 μl 90 μl 360 μl 20 C

TruePrime Single Cell WGA Kit

For in vitro Veterinary Diagnostics only. Real-Time PCR Detection Kit for detection of Histomonas meleagridis.

Ureaplasma Urealyticum Real Time PCR Kit

Lecture #1. Introduction to microarray technology

Reagent Kit Selection Guide

QIAGEN s NGS Solutions for Biomarkers NGS & Bioinformatics team QIAGEN (Suzhou) Translational Medicine Co.,Ltd

Job Ready Assessment Blueprint. Biotechnology. Test Code: 4075 / Version: 01. Copyright 2014 NOCTI. All Rights Reserved.

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Copy number standard curve. for absolute quantification by real-time PCR

Ligation Sequencing Kit 1D (SQK-LSK108) Ice bucket with ice NEBNext End repair / da-tailing Module (E7546)

Single Cell 3 Reagent Kits v2 Quick Reference Cards

Worm Genomic DNA Prep

SUPPLEMENTARY MATERIAL AND METHODS

Redefining Automation

FrameStar. 2-component plates & standard PCR plastic

MicroRNA Profiling with TaqMan OpenArray Plates

ab ChIP Kit Magnetic One-Step

Transcription:

Single cell isolating for downstream DNA and RNA analysis

Platform for single cell isolation and analysis VyCAP s single cell isolation and analysis platform delivers an unparalleled efficiency and simplicity that revolutionizes the way you select and isolate single cells. The platform is specially designed to enable the isolation of single cells that cannot be isolated by other technologies. For example, isolation of single cells from a sample that only contains a limited number of cells (1 10.000) in a sample volume of 100µl - 40 ml and isolation of single cells with a very low frequency of appearance, for example CTC and fetal trophoblasts. The Puncher platform solution comprises of two essential parts: 1. A single cell disposable, that contains a microwell chip that distributes single cells in individual wells 2. A Puncher system, to acquire fluorescence images of the single cells in the microwells and to transfer the selected cells from the microwells to the reaction tube or plate of choice, for example 0.2 ml Eppendorf PCR tubes or PCR well plates The innovative single cell disposable distributes single cells in individual microwells. After completion of the cell distribution the Puncher system acquires high quality multi-colored fluorescence images of the single cells in the microwells. Based on these images the user identifies the cells of interest and transfers the selected cells to the reaction tube or plate of choice in a fast, automatic and controlled manner with minimal cell losses. Unique Selling Points of the Puncher platform Short workflow (<1hr) to obtain single cells, for DNA and RNA analysis and clonal expansion Single cell isolation and transfer efficiency > 95% Validated protocols Single cell selection based on high quality immuno-fluorescence images Automated system

Puncher system to select and isolate single cells Workflow

Single cell distribution in a microwell chip Pump-unit, single cell disposable and slide with microwell chip Fluorescence image of single cells in the microwells Principle of seeding. After a cell blocked the pore the next cell is diverted to the next availabale well Punching single cell isolation efficiencies of > 95%

Single cell analysis Single cell WGA with VyCAP Quality control kit Single cell isolation, followed by WGA using Silicon Biosystems AMPLI-1 and Qiagen Repli-G WGA kit. The quality of the obtained WGA product was determined using VyCAP s QC mix on 10 DNA fragment of 10 chromosomes. Maximum number of bands Ampli-1 = 7, Repli-G = 10 VyCAP has validated protocols available for single cell isolation followed by WGA. Single cell gene analysis Single SKBR-3, LnCaP and PC-3 cells were distributed in the microwells. The cells were identified by their fluorescence image and isolated. WGA was performed followed by VyCAP s WGA QC mix and Sanger sequencing. SKBR-3 : no mutations in PTEN and ROBO2 LNCaP: heterozygous mutation in the PTEN gene (CR450306.1:c.16,17 delaa) PC3: heterozygous mutation in the ROBO-2 gene (NM001128929.3:c. 508 C>T)

Software to select and isolate single cells The Puncher system is controlled by dedicated software which allows the user to select and isolate single cells in a simple and efficient manner. The software has the flexibility to adjust the scanning and imaging parameters to your needs but can as well be used in an automated mode where it uses fixed settings. The screenshot below displays a gallery of single cells in the microwells. The gallery is generated after the image acquisition is completed. The user transfer selected cells towards a specific tube or well. Define the corners of the microwell chip Set the image acquisition parameters Scan the microwell chip

s Puncher system Pump unit The VyCAP Puncher is based on a Nikon Ti-2 inverted fluorescence microscope. It is equipped with dedicated hardware to transfer a single cell from the microwells chip to the collection tube or plate of choice. It uses high end scanning stages, Lumencor LED excitation light source and a Hamamatsu CMOS scientific camera to acquire high quality images with a high fluorescence sensitivity. It comes with dedicated software that enables the user to acquire images of the single cells and next select and isolate the cells of interest from an gallery that is automatically generated. Puncher system Ti2-PS The pump-unit is used in combination with the single cell disposable. The pump creates a negative pressure at the waste side of the disposable. The system has an adjustable pressure from 0 250 mbar. Pump unit ( 0 250 mbar) PU-250 Single cell disposable The single cell disposable contains a slide with a microwell chip. This chip contains 6.400 microwells. Each microwell has a diameter of 70 µm and the bottom contains a single pore with a diameter of 5µm. Single cell disposable (24 units) FM- 510 Punch needle The Punch needle is an essential part of of the Puncher system to transfer cells from the Microwell chip towards the reaction tube. The tip of the Punch needle is shaped such that it punches out the bottom of the microwell without touching the cell. Punch needles (5 units) PN-70 WGA Quality Control mix The WGA Quality Control mix is a PCR-based assay to determine DNA integrity of the WGA product. The quality of the product is determined by the presence of 10 DNA fragments in the WGA product. WGA QC mix for 50 tests WGA QC-50

Contact VyCAP BV Hallenweg 23 7522NH Enschede The Netherlands info@vycap.com +31 6 14773442 Suzhou Junhui Biotech Co. Ltd, 3rd Floor, Building 3, No. 52 YinGang Road TaiCang, SuZhou, JiangSu Province 215434, China jonathan.yan@junhuibio.com +86 18621616172 www.junhuibio.com WeChat: JunHui-Bio