Data Sheet 110kV TD123II dry type outdoor termination

Similar documents
3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

PRY-MOULD. High Voltage Accessories for Extruded Cables

Product Information. Stress Control Element Insulation. 3M QS 2000E 24kV I DN A

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

INSULATORS NEW. See page J-4 for more information.

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

Brugg Cables High Voltage Accessories. Swiss solutions for independent applications.

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

NPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS

Resin impregnated paper bushings. Product information

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

PILC Replacement: Getting the Lead Out

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

CCC Services for oil-filled- and XLPE-Cable Systems

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

U.V resistance UL Sunlight Resistance. Flame retardant IEC

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

ROLINX Laminated Busbar. Design Rules Version 01 (12/2015)

Energy Division Insulators

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Technical Specification for LV ABC Fuse Switch Disconnectors

TURKISH ELECTRICITY DISTRIBUTION CO. TECHNICAL SPECIFICATION FOR POST (SUPPORT) INSULATORS FOR MEDIUM VOLTAGE SYSTEMS

General Requirements. Technical Specifications for Insulators of Transmission Lines

Details of technical leaflets/write-up on various pieces of equipment.

Armoured Instrumentation Cables to BS7917

Electrical Insulating Tapes

Polymer Station Post Insulators for 69 to 345 kv Applications

NPS/002/023 Technical Specification for 132kV Power Cables.

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Single core conductor BETAtherm 145

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

NARROW PITCH (0.4mm) CONNECTORS P4S SERIES

INTERNATIONAL STANDARD

3M Thermally Conductive Adhesive Tape 8940

Gas-insulated medium-voltage switchgear. for wind parks. Answers for energy.

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

Property Thickness Units Value Test Method Test Conditions μm MD* TD* N/mm² % 170. Shrinkage % DIN C, 15 min.

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

COASTAL INDIA. Supply & Application of: Epsilon Midsun 570 Gen-4 RTV HVIC (High Voltage Insulator Coating) and

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES

Cable junction boxes with intrinsic fire resistance and insulation integrity

Performance Analysis of 33 kv Polymer and Porcelain Insulators under Various Pollution Conditions at Costal Regions

Cast resin joint for paper- and plastic insulated cables for low voltage applications till 0,6/1 (1,2) kv.

Pins Insulator. Composite/Polymers Insulators

INTERNATIONAL STANDARD

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

Polymer Suspension Insulators 69kV to 765kV

Artificial Accelerated Ageing Test of Silicone Rubber Housing Material for Lightning Arrester

Surge arrester 3EB4. with polymeric composite housing for operating aboard traction units

Accelerated Aging Tests for MV Cables

Investigation of leakage current flow through wooden poles structures on overhead distribution system

Polymer Post Insulators for 46 to 500kV Applications

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

V. Design, Application, Maintenance & Operation Technical Requirements

LINDSEY EMERGENCY RESTORATION SYSTEM

an ISO9001 company TECHNICAL INFORMATION FOR TGS2600 Technical Information for Air Quality Control Sensors

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

P.V.C. INSULATED UNARMOURED COPPER CABLES

Instruction guide Medium Voltage equipment on sites exposed to high humidity and/or heavy pollution. Recommendations for installation and use

ISO INTERNATIONAL STANDARD

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

Engineering Data for Copper and Aluminum Conductor Electrical Cables

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

VPL-3200B Residential Vertical Platform Lift Technical Specifications

curamik CERAMIC SUBSTRATES AMB technology Design Rules Version #04 (09/2015)

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

Industrial flue gas probes. Instruction manual

2 of 13 pages Directory 1. Outline Drawing 3/13 2. Features 3/13 3. Typical Applications 3/13 4. Specifications 3/13 5. Capacitor series code informat

Bonded Neo Magnetization Guide

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

MMP - Metal Film MELF

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

DATA SHEET. EM1000 Fine Ribbed Electrical Safety Matting, rated to IEC61111:2009 Class 0

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 66 kv LIGHTNING ARRESTORS

TECHNICAL SPECIFICATION FOR 11 POST INSULATORS, 11 KV & 33 KV PIN INSULATORS AND 11 KV, B&S TYPE 45 KN & 70 KN DISC INSULATORS.

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

Heat-Shrinkable Tubing

Carbon film resistors

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

CIGRE C4 Colloquium on Lightning and Power System, Kuala Lumpur, May 2010

TECHNICAL SPECIFICATION FOR LT PIN/SHACKLE INSULATORS

HAM BAKER. Disc Diffusers. Overview GROUP

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

THE PERFORMANCE OF XLPE WATER TREE RESISTANT INSULATION SYSTEMS AGAINST THE REQUIREMENTS OF DIN VDE /A3

RBK-ILS-125 SCOPE. This Quality Assurance Specification establishes the quality standard for RBK-ILS-125.

Thermocouple for Flue Gas Temperature Measurements,

Transcription:

3 Data Sheet 110kV TD123II dry type outdoor termination 1. Product Description: 3M 110kV TD123II dry type outdoor termination meets requirement of test and product according to IEC60840 and GB11017.3, one piece, dry type termination made silicone rubber body. The termination is designed to 64/110kV, XLPE insulation, and metallic sheath cable. Product Feature: Designed for 64/110kV class, system voltage: 126kV. Meet requirement of IEC60840 and GB11017 standard. One piece design without parting line, no debonding. Easy to install and wide range of cable size. Compact termination body, benefit for installation and fixture space. Excellent performance of silicone materials, good creepage performance, UV, contamination and hydrophobic performance. Good outdoor performance of big/small skirt. Special design for stress cone surface to reduce high stress and optimize stress distribution with thinner insulation thickness. Cold shrink technology for top sealing. Current collection ring with silicone for creepage performance and bottom sealing. Optimized Product Design: TD123II dry type termination is designed with stress distribution analysis and material technology, the stress cone designed to minimize surface stress by uniformly redistributing the electrical field over the entire surface of the insulator, it will provide voltage of AC test and impulse test to meet operation requirement for long term and environment. Silicone Materials: TD123II dry type termination is use of liquid silicone materials for insulation and stress cone. Track resistance is up to 4.5kV/mm; shorten recover time for hydrophobic performance. Stress Distribution:

2. Physical & Electrical Properties: 2.1 Silicone Rubber for Insulation: Test Item Typical Value Test Method Tensile strength 550% ISO 37 Tear strength 9 N/mm 2 ISO 37 Hardness Shore A 40 ISO 868 Recover time for hydrophobic 5.0h 3M test method No.406 Dielectric constant 2.7 IEC 60250 Dissipation factor 0.003 IEC60250 Dielectric strength 28 kv/mm IEC60243 Track resistance (4.5kV) 6.0h IEC60587 2.2 Silicone Rubber for Semi-conductive: Test Item Typical Value Test Method Tensile Strength 650% DIN 53 504 S2 Tear Strength 7 N/mm 2 DIN 53 504 S2 Hardness shore A 40 DIN 53 505 Volume resistance 45 Ω cm DIN 53482 2.3 Electrical Properties: Electrical Properties Typical Value Rated voltage class U 0 /U Max. permissible system voltage U m Current carrying capability Permissible short-circuit current I s Max. conductor temperature 64/110kV 126kV According to cable According to cable Max:100kA a. operation 90 b. short-circuit 5s 250 With pole centre distance 1100mm Leakage path 4050 Flash over distance Position of installation Pollution layer class power frequency withstand voltage Upw Lightning impulse withstand voltage U ps 1.2/5.0 Typical test (according to IEC 60840) Conductor connection technique 1420mm Vertical/horizontally(Indoor) Ⅲ 192kV,6h,No breakdown and flashover 550kV Compression Weight(not including cable) Approx. 30kg Cable conductor cross section 240-630mm 2 Installation range 57-66.5mm

3. Application: Product: This termination is used for 64/110kV class, meets requirement for long term performance of indoor and outdoor application. It could connect with equipment or line, for example, switchgear, transformer, bushing, overhead line etc; the termination also could be used in power station and on power tower, the actual application about fixture should be determined by actual design and requirement to environment, termination must be straight and no bending, normally is installed vertically in power station, also could be lean installation like on tower(max. lean angle: 45 0 ), it could be applied for connection with wire and transformer; some environments without heavy pollution and humidity, horizontal installation could be used. The operation temperature is 90, temperature during short circuit is 250. The installation should be handled by operators who have intelligence and had been trained and certificated by 3M; the installation should be followed by 3M drawing and instruction and installed on suitable cable. Selection Table: Termination Selection: Product Conductor cross section mm 2 Insulation OD. mm TD123-Ⅱ 240-630 57 66.5 Note:the selection is based on cable insulation OD. and cross section is reference. Selection for connection bolt: OD. for compression (A) mm Inner diameter (B)mm Hole depth (C) mm Connection OD. (D) mm Cross Section mm 2 Cu Al Cu Al Cu Al Cu Al 240 32 32 21 21 300 32 36 23.5 23.5 400 36 42 26 26 500 42 44 28 28 116 116 30 30 630 44 / 34 / / /

Product Drawing:(Typical Value)

4. Typical Test: Test standard:gb/t 11017.3-2002 IEC60840 Test Item Test Requirement Test Result Partial Discharge No detectable discharge from the test object at 96kV 1.2pC Heating cycle voltage test As per clause 3.2 of this report Partial discharge test at high temperature Partial discharge test at ambient temperature Lightning impulse withstand test Power frequency voltage test after impulse voltage test Power frequency voltage wet withstand test Radio influence voltage test No detectable discharge from the test object at 96kV No detectable discharge from the test object at 96kV No breakdown or flashover should occur at 10 positive and 10 negative impulses of 550kV No breakdown or flashover should occur at 160kV for 15min No breakdown or flashover should occur at 185kV for 1min Radio influence voltage should not exceed 450 μv at 1MHz and 81kV 1.2pC 1.2pC 110μV 5. Installation: The installation drawing is in package. Installation workflow as below, detail please read instruction: Remove outer sheath Wiping and soldering Cable Preparation Cable Heating and Straight Peeling and Sanding Insulation Install leakage current collector Sealing for termination bottom Cleaning insulation Apply semi-cond. Spray graphite Termination Installation Push on termination body Compressing connection bolt Installing end cap Installing PST sealing tube

Typical Application: 1. Application in Power Station: 1. TD123II 2. Arrester 3. Hard pole 2. Application on Tower: 1. Arrester 2. TD123II 3. Insulator Note: 1. The fixture of termination is designed according to the height of tower, see above figure, it could be fixed together with arrester and insulator, the end of termination should be also fixed on tower. 2. After fixing on tower, the termination should be straight and no bending, it could be leaned, but no less than 45 0, the bottom of termination should be fixed following cable line. 3. Termination must be connected with hard pole and more short connection wire will be better.

Installation Tools: Adapter Connection bolt I Connection bolt II Push part Position ring Ball screw I Handle Ball screw III Drive part Installation Tools List: Item Part Description Pic 1 Ball screw Ⅰ 1 2 Ball screw Ⅲ 1 3 Drive part 1 4 Push part 1 5 Adapter 1 6 Connection bolt Ⅰ 1 7 Connection bolt Ⅱ 1 8 Handle 1 9 Position ring 1 6. Maintenance: The components of TD123IItermination are not impaired by freezing or heating up to 43 due to ambient temperatures found in storage or shipping. Normal storage and stock rotation are recommended. The manufacture date could be found in certificate in package. The termination can be used before following date: 1. Termination body: 5 years. 2. Tape and others: 3 years IMPORTANT NOTICE TO PURCHASER: All statement, technical information and recommendations related to the Seller s products are based on information believed to be reliable but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. 3M China Limited R&D Center 222 Tian Lin Road, Shanghai 200233 P. R. China, Fax: (86-21)2205173, Tel: (86-21)22105335