Module 2, Add on Lesson Turbidity Sensor. Teacher. 90 minutes

Similar documents
Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes

Transparency A Water Clarity Measure

Total Dissolved Solids

CHEMICAL MONITORING & MANAGEMENT LESSON 6: WATER QUALITY 1 SAMPLE RESOURCES

Evaluation copy. Total Dissolved Solids. Computer INTRODUCTION

Measuring Turbidity with Filters

Activity 1: Using the Level of Oxygen- Saturation Chart graph Dissolved Oxygen vs. Temperature at 100% saturation. Start by making a 2 column table.

Dirty Water. Adapted from: Dirty Water in Living in Water. National Aquarium in Baltimore, Grade Level: all. Duration: 1-2 class periods

Factsheet: Town of Deep River Water Quality and Stormwater Summary

Eutrophication: Too Much of a Good Thing?

Rev Experiment 10

OPERATING INSTRUCTIONS

Methods: Record the date and time in the data book.

Water Quality Lab Packet Environmental Science

) and it s ideal van t Hoff factor is 4. Note that polyatomic ions do not break up into their constituent elements.

To whom it may concern, February 21, 2011

FOR 3457 Forest Watershed & Water Quality Watershed Management Tools & Methods. Water Quality Lab

Filtering Out Pollution Lowering Turbidity to Increase Water Quality

Photo tour of the monitoring activities found in the Stream Side Science manual

Parts Per Million. Vocabulary: MCL, MCLG, ppm (parts per million), dilution

Salinity in Seawater

Engineering with Renewable Energy: Solar Water Pumping

The determination of copper in brass

TREATMENT PLANT OPERATOR TRAINEE Examination Study Guide

Outer Cove Brook Network

Name Honors Chemistry / /

CTD (CONDUCTIVITY-TEMPERATURE-DEPTH)

Eutrophication Using Up Oxygen In Water

It is not essential for students to conduct an investigation for every question they generate or generate questions based on prior investigations.

SOLAR ENERGY. SolarEnergy,Kit#6B: EfficiencyofSolarCels. SolarExtensionActivities INSTITUTEFORSCHOOLPARTNERSHIP PARC

Water Pollution: Sediment

Acid Rain. Evaluation copy. Figure 1: Typical rain ph in United States.

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

Simple Field Tests for Water Quality

I ~ b.thedependentvariable: Title:

4THE UNIVERSITY OF THE STATE OF NEW YORK

Water Temperature Protocol

R = kc Eqn 5.1. R = k C Eqn 5.2. R = kc + B Eqn 5.3

Nickel Electroplating

Water Chemistry. Water 101

Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

COMPOSITION OF SEAWATER

Checkpoint Science Scheme of Work. Physics Year 3. Topic: Electric Charge

INTERMEDIATE BMI ASSESSMENT TIER 2 FIELD SHEET

Temperature: Air vs. Water vs. More Water

Characteristic and efficiency of PEM fuel cell and PEM electrolyser

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

Water Quality Temperature

S-0163 Revision B. C-sense pco 2 Sensor

Heating Earth Surfaces

Fish Tank Project Overview ME 121 Mechanical Engineering Freshman Curriculum Portland State University

Measuring Manganese Concentration Using Spectrophotometry

Global Warming and Sea Level Rise

Sci-Tech. Connections. The Heat's On. Hot Potatoes Grade 7 Sampler

solvent diffusion dissolving soluble

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

Electricity. Characteristic and efficiency of PEM fuel cell and PEM electrolyser Stationary currents. What you need:

Solar Cooker Lab Instructor s Guide Motivation:

Introduction to Water Quality Parameters

Standard Operating Procedure for:

Reporting Period: 01/01/2010 to 12/31/2010. Understanding the Level 2 Stream Monitoring Data Report

Measuring Ocean Color: The Basics

cooling pond: a pond where hot water from factories and power plants is stored until it is the same temperature as nearby bodies of water.

Electrolysis, electrode polarisation, decomposition voltage, galvanic elements, Faraday s law.

Underwater Avalanche: Turbidity Currents Investigating Density Currents

Interpreting Lake Data

Name Date SEQL Student Pre/Post-Test-6 th Grade Science KEY

Materials. Materials. NOTE Delta Education Customer Service can be reached at

Electric and Magnetic Forces

Water Wonders. Purpose. Materials. Overview. Student Outcomes. Time. Level. Part 1: Part 2: Part 3 (optional):

A student investigated the efficiency of a motor using the equipment in Figure 1. Figure 1

SAMPLING YOUR ESTUARY Level IIB WHAT S IN THE WATER?

AP Lab 12--DISSOLVED OXYGEN & AQUATIC PRIMARY PRODUCTIVITY (LabBench)

Energy Content of Food

Zinc 17. Part 2 Practical work

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

CBSE QUESTION PAPER CLASS-X SCIENCE

Dissolved Oxygen and Aquatic Primary Productivity Analyzing Dissolved Oxygen in an Aquatic Ecosystem over Time

Environmental Inquiry p Rice Hall, Cornell University, Ithaca, NY (607)

Horizontal Borehole Study

One to two class periods depending on how much of the lab set-up is done before hand and the length of the pre-lab and follow-up discussions.

AP Environmental Science

Water Quality: The Basics

Experiment B-38 Monitoring Yeast Growth

Stoichiometry. Lab. FCJJ 16 - Solar Hydrogen Science Kit. Next Generation Science Standards. Initial Prep Time. Lesson Time. Assembly Requirements

DETERMINATION of the EMPIRICAL FORMULA

ATS430 turbidity and TSS Optimize your water discharge quality through accurate turbidity and suspended solids measurement

TEKS Lesson 7.8C: Effects of Human Activity on Surface Water and Groundwater

IDS 102 Answers for Specific Heat End of Module Questions

Bacterial Counts - Quantitative Analysis of Microbes

Summary. River. 5 th 8 th. about the. Chemical. anteceden. Grade Level: 5 th. 12 th. Objectives: instructions to. determine the. Chicago River Field

Primer on Pond & Lake Ecology & Watershed Dynamics

7.9.6 Magnetic Poles. 85 minutes. 117 marks. Page 1 of 37

March Chemistry Project v3. Chemistry Project

LAB. LAB BENCH DISSOLVED OXYGEN & AQUATIC PRIMARY PRODUCTIVITY

Science Supply List Earth Science

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Science Supply List

Density Answers to the End of module questions

Turbidity Colour Oil in Water Water in Oil Oil on Water Ultrasonic Particle Monitoring

Transcription:

Module 2, Add on Lesson Turbidity Sensor Teacher 90 minutes Purpose Construct a sensor to measure the turbidity of water Graph data and reason about curves and linear relationships Calibrate the turbidity sensor Write an NXT program to display and collect turbidity measurements Materials Copy of the lesson Liquid electrical tape 1 Half of an NXT cable electrical tape 1 NXT 1 Pencil Solder and soldering iron Paper clips 4 feet of Hook-up wire Plastic cups or beakers 1 6 inch length of PVC tubing Graph paper (or Excel) 1 LED Balance/scale 1 100Ω resistor clay 1 Photoresistor Solutions of known turbidity for calibrating and assessing sensors Background Turbidity refers to how clear or how cloudy the water is; clear water has a low turbidity level and cloudy or murky water has a high turbidity level. High levels of turbidity can be caused by suspended particles in the water such as soil, sediments, sewage, and plankton. Excess soil can enter a waterbody by erosion or runoff from nearby lands. Sediments can be stirred up by activity in the water, caused by organisms living in the water, humans, machinery, and powerful weather events. Turbidity is often measured to provide a quick estimate of the total suspended solids or sediments (TSS) concentration (in milligrams dry weight/l). If the turbidity level of the water is high, there will be many suspended particles in the water. These solid particles will block sunlight and can prevent aquatic plants from getting the sunlight they need for Turbidity Sensor 1

photosynthesis. The plants will produce less oxygen thereby decreasing the dissolved oxygen levels. The plants could die and decompose in the water, which will further reduce the dissolved oxygen levels. Suspended particles in the water also absorb additional heat from sunlight which will result in warmer water. Warm water is not able to hold as much oxygen as cold water so dissolved oxygen levels will decrease. Suspended particles are also destructive to many aquatic organisms. Excessive amounts can clog the gills of fish and interfere with their ability to find food. They can also bury bottom dwelling creatures and eggs. Suspended particles can transport pollutants through the water. There are several methods to measure turbidity. One method is with a Secchi disk. This disk has a black and white pattern on it a Secchi pattern. The Secchi disk is slowly lowered into the water until it is no longer visible then the depth at which it disappears from view can be used as a measure of turbidity. This Secchi depth is inversely proportional to turbidity a large Secchi depth indicates a low turbidity and a small Secchi depth indicates a high turbidity. A Secchi disk is useful in deep water, but not very usefu in shallow water because you might not be able to lower it deep enough for it to disappear from view. For shallow waters it can be useful to measure turbidity with a transparency/turbidity tube. A turbidity or transparency tube is a graduated glass or plastic measuring cylinder, with a small black and white Secchi pattern at the bottom. Sample water is collected and added to the tube until the Secchi pattern on the bottom is no longer visible the depth of water in the tube can now be used as a measure of turbidity. The tube is calibrated so that the turbidity can be read off the side in appropriate units. Units of turbidity There are a variety of different units that can be used to measure turbidity. Secchi depth is often used in deep water. Turbidity tubes are sometimes calibrated in Jackson Turbidity Units (JTU)- originally defined as a measure of how much water is needed to obscure a candle flame viewed through a turbidity tube. Electronic turbidity meters are typically calibrated in Nephelometric Turbidity Units (NTUs) which are a measure of how much light is scattered or reflected off particles suspended in the water. Often the purpose of measuring turbidity is to estimate the total suspended solids (TSS) in the water. In such cases the turbidity sensor can simply be calibrated in units of grams of suspended solid per liter of water. This is the approach we will take in this lesson. Note that this method will not give you an accurate measure of the suspended solids in the actual lake or river you are measuring, unless you use the same kinds of solids when you calibrate your sensor in the laboratory. For example, for the same number grams of suspended solid, different kinds of solids (substance, particle size, etc) will cause different turbidities. A turbidity reading of 0-10 NTU is considered normal. A clear mountain stream might have a turbidity of around 1 NTU, whereas a large river like the Mississippi might have a dry-weather turbidity of around 10 NTUs. These values can jump into hundreds of NTUs during runoff events. Therefore, the turbidity meter to be used should be reliable over the range in which you will be working. A Secchi depth less of less than 1 meter indicates a high concentration of suspended solids. Turbidity Sensor 2

Electronic turbidity sensor In this lesson you will build an electronic sensor to measure turbidity. The sensor consists of two main components: a light source (light emitting diode or LED lamp) and a light sensitive device (photoresistor). The LED and the photoresistor are fixed a short distance apart in such a way that water can flow between them. The more turbid the water, the less light from the LED lamp will reach the photo-resistor. The photo-resistor is a device which changes its resistance depending how much light falls on it. Therefore, by measuring the resistance of the photoresistor, you can measure how much or how little light reached it from the LED lamp, and therefore turbidity. Procedure Part 1 Constructing a turbidity probe and connecting it to the NXT NXT computer Photoresistor Sensor port 1 LED Resistor Short leg Long leg Fig. 1. Connections between NXT and turbidity sensor components Turbidity Sensor 3

White lead Black lead Red lead Short leg Long leg Green lead Fig. 2. Circuit diagram of NXT and turbidity sensor components. How it works: The green and red leads supply 5V across the resistor and LED, which makes the LED light up this part of the circuit is just like connecting a battery across a light bulb. The resistor is included simply because it causes less current to flow through the circuit, preventing the LED from being damaged by too much current. The black and white leads connect the photoresistor across the NXT s internal voltmeter the same way as the thermistor across the NXT voltmeter. As water turbidity increases, less light will reach the photoresistor, and resistance increases. Similar to the thermistor, the photoresistor forms a potential divider circuit with the NXT s internal 10kΩ resistor and the NXT s internal 5V battery. The bigger the resistance of the photoresistor, the bigger the portion of the NXT s 5V will be divided across it, and increased raw values measured by the NXT s internal voltmeter. Construction: 1) Apply liquid tape to the LEDs and photoresistors as shown (make sure to leave the ends bare to solder hook-up wire). Try to coat the wire legs fully so that the wire is fully covered all the way up to the base of the component itself. The sensor will only work if the connections are fully waterproof. Be careful not to block the LED lens or the photoresistor surface. Turbidity Sensor 4

2) Solder each of the LED legs to a piece of hook-up wire. CHECK WHICH LED LEG IS LONGEST, AND LABEL THE HOOKUP WIRE CONNECTED TO IT (for example, you could use a blob of liquid tape, as shown). Later we will have to be careful to connect the LED across the NXT the right way round-it only works one way and not the other. 3) Solder the leads of the photoresistor to two more pieces of hook-up wire. Red blob as reminder Short leg Long leg 4) After soldering, coat the connections to both the LED and the photoresistor with liquid tape. Make sure no bare wire or solder is left unsealed. Your sensor may not work properly if any wire or connection is left exposed to the water. 5) Solder the resistor to the other end of the hook-up wire connected to the longer lead of the NXT (the one you marked with a red blob in step 1). (If you forgot to mark the wire and now you can t tell which lead is which, ask your teacher for help). Teachers: You can use the multimeter to check which lead is correct. Set the multimeter on the diode setting and touch the probes to the wires going to the LED. If the LED lights up, the wire you re touching with the red probe is the side they should connect the resistor to. If the LED doesn t light up, put the probe on the opposite wire. (If the LED still doesn t light up, either the students have a loose connection going to the LED or the multimeter has a bad battery or fuse.) 6) Take half of an NXT connector cable, strip off an inch of the black outer jacket, and strip the ends of black, white, red, and green leads which you find inside. The yellow and blue leads are not needed so they can be clipped off short or just folded out of the way. 7) See figure 1. Solder the free end of the resistor to the green lead. 8) See figure 1. Solder the red lead to the remaining end of hook up wire coming from the short leg of the LED. Turbidity Sensor 5

9) See figure 1. Solder the two hook up wires from the photoresistor to the white and black leads it doesn t matter which way round. 10) Coat any exposed wire or soldered connections with liquid electrical tape. 11) Wrap a pencil with black electrical tape, this will minimize light reflection. 12) Fold back a few inches of each of the four hookup wires and tape them to the black NXT connector cable. Place the LED and photoresistor 1 inch apart. The distance between the LED and photoresistor will alter results between sensors, so do not become overly concerned if your data does not exactly match with classmates data. 13) Place the LED and photoresistor toward one end of the pencil, not the center. To minimize the amount of water your sensor will require to collect data, the LED and photoresistor should be placed closer to the end of the tube you will submerge in the water, however not at the very end of the tube because that will allow too much light between the LED and photoresistor. 14) Secure all of the wires to the pencil wrapped with electrical tape - this will help prevent accidental strain on the solder connections. 15) Slide all of the wires and pencil into the PVC tube section and secure wires and pencil with paperclips to the end of the tube to prevent the sensor from moving too much within the tube. Experiment 1 variation of NXT raw values with turbidity NXT programming: Write and download the following program into the NXT. It measures the voltage across the photoresistor (as an NXT raw value) and displays it on the screen. Set sensor block to read from sensor port 1 This NXT code means: In an infinitely repeating loop: Read the raw sensor value (0-1023) Infinitely repeating loop keep on repeating anything inside this loop Convert the number into text Display text on screen Convert this number into text Display the text on the NXT screen Keep on repeating Read in raw sensor value Remember to set the Display icon to display text Turbidity Sensor 6

Experimental procedure: 1) FIND AND READ THE INSTRUCTIONS AT THE END OF THIS LESSON FOR MAKING SOLUTIONS OF KNOWN TURBIDITY. Follow these instructions when making up solutions of turbidities. Begin with a 750ml cup of pure tap water, i.e. zero Total Suspended Solids, or a turbidity of zero mg/l TSS. 2) Submerge your turbidity sensor in the water and read the corresponding NXT raw value from your NXT screen. Record your values in table 1. 3) Repeat this procedure for several successive dilutions. Each time you put your sensor in a cup, you MUST do three things: Rinse your sensor in the rinse water. Stir the cup very well (and right down to the bottom) right before you put your sensor in. Try to take your measurement within 10 seconds or so after stirring. Note to teachers: Time permitting, you may want students to measure each container two or three times (stirring before each trial), and average the results. Table 1 Turbidity TSS (mg/l) 0 NXT Raw Value 6) Plot a graph of your results. Use the horizontal (x) axis for NXT raw value, and the vertical (y) axis for turbidity. Turbidity Sensor 7

Graph should look something like this: If you leave a lot of space in this region of your graph, then you can use a ruler to extrapolate your graph to find the y axis intercept. More accurately, you could spread your data points over as much of the graph paper as possible, and then use a calculation involving the gradient to figure out the y intercept. If you use excel for graphing then excel can calculate gradient and y intercept for you. Turbidity Sensor 8

Experiment 2 calibrating and testing your turbidity sensor Modify your NXT program to output turbidity in correct units of TSS mg/l instead of raw NXT values. To do this, you must first find a mathematical equation which describes the relationship between NXT raw values and turbidity in mg/l, and then program this equation into the NXT so that it can convert from NXT raw values to TSS mg/l. 1) Using a ruler (or Excel), plot a best fit straight line through the points that you plotted on your graph in experiment 1. 2) Find the equation of this straight line in the form of y = mx + b i.e. use your graph to find correct values for the constants m and b, where m is the gradient of the line, and b is the y-intercept. You now have a relation of the form: turbidity = m NXT-raw-value + b equation 1 compare: y = m x + b This equation converts NXT-raw-values into turbidities. 3) Add more program blocks to your NXT program use equation 1 to make your NXT output turbidity in units of mg/l TSS. Your program needs to do the following: In an infinitely repeating loop: Read the raw sensor value (0-1023) Multiply raw sensor value by gradient value m Add the y-intercept value b Convert the resulting number into text Display the text on the NXT screen Keep repeating Your program should look something like this (see next page): Turbidity Sensor 9

m value goes here Your NXT should now display turbidity in units of mg/l TSS. b value goes here. Note in example b is negative, so we use subtraction. 4) Test your sensor by re-measuring the solutions of known turbidities. Does your NXT display the correct turbidity values in mg/l TSS? 5) Ask your teacher for samples of unknown turbidity and use you sensor to measure the turbidity. Record your results below. Turbidity Sensor 10

Assessment 1) In steps 4 and 5 above, what was the error in each case, and what was the average error? 2) If you were going to market the turbidity sensor, what would you advertise as its accuracy? 3) What are the possible sources of error? 4) List two improvements you could make to create a more accurate turbidity sensor. Turbidity Sensor 11

End-note: generating test samples of known turbidity One measure of turbidity is the units of suspended solids concentration of a test sample. This concentration is given as the amount of mass of particles that are present in a certain volume of solution. The higher the particle concentration, the cloudier the water will be, and the higher the turbidity. To make test samples, start with the following: 200 mg (x) = 750x = 200,000 = x = 266.7 mg 750 ml (1000 ml) 750 750 Liter Turbidity Sample 200 mg 750 ml 350 mg 750 ml 600 mg 750 ml 700 mg 750 ml Per Liter 266.7 mg/l 466.7 mg/l 800 mg/l 933.3 mg/l Place a pencil in each cup, and stir each sample well. Also, fill a rinse large container with water to rinse for the sensor with in between samples. Turbidity Sensor 12