PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

Similar documents
PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

BUILDING PERMIT APPLICATION

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

One and Two Family Additions

2003 International Residential Building Code

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

CONSTRUCTION CODE PERMIT INFORMATION

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

RESIDENTIAL BUILDING PLAN REQUIREMENTS

Residential Building Permit Application

Applying for Permits to build a new house in Linn County

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Building Guide. Colorado Chapter of the International Code Council

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

BUILDING PERMIT PROCEDURE PLEASE READ CAREFULLY AND FILL OUT COMPLETELY TO ASSURE QUICK AND ACCURATE SERVICE

General Residential Code Requirements

Administrative Changes

City of Donnelly. Permit Application Information and Instructions

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

BUILDING PERMIT APPLICATION

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

BYRON TOWNSHIP BUILDING PERMIT APPLICATION 8085 Byron Center Ave SW., Byron Center, MI /Fax

City of Owatonna Residential Plan Submittal Checklist

City Planning & Development - Development Services (CPD-DS) 414 E. 12th Street 5 th Floor Kansas City, Missouri Telephone (816)

CITY OF GLASGOW BUILDING PERMIT APPLICATION 126 E. Public Square Glasgow, KY Phone: (270) Fax: (270)

Commercial Remodel Permit

Application for Commercial Plan Review and Building Permit. Address:

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Fast Track Re-Roof Permit Checklist

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

DECK PLANS City Of Grand Rapids Building Safety Division

Each proposed project will be reviewed for compliance with the following codes as applicable.

The Homeowner s Building Application Checklist for Constructing a Residential Addition

District of Barriere A GUIDE TO BUILDING PERMITS

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

City of of Dauphin WOOD DECKS. Zoning and construction requirements for non-sheltered wood decks for residential dwellings.

Town of Pittstown. Office of the Building Inspector / Code Enforcement Officer

Building Permit Application Instructions INFORMATION REQUIRED FOR ISSUANCE OF A BUILDING PERMIT

The following materials and documents are required in order for you to obtain a Building Permit:

Job Site Address. Lot/Parcel# Permit To: New Addition Alter/Remodel Code Compliance

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

FACT SHEET #2 DECK INFORMATION

BUILDING CODES & DESIGN CRITERIA

BUILDING PERMIT APPLICATION

An Applicants Guide to Residential Building Permits City of Galt Building Department

RESIDENTIAL BUILDING PERMIT INFORMATION

RESIDENTIAL BUILDING REQUIREMENTS

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

1 AND 2 FAMILY DWELLING REQUIREMENTS

APPLICATION FOR PORCH / DECK PERMIT

Residential Accessory Structures & Room Additions

DECK INFORMATION SHEET

CITY OF CRANSTON RESIDENTIAL PERMIT PROCEDURE BASEMENT RENOVATION

All new construction, mobile home placement & additions.

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

TYPICAL BEARING WALL FRAMING

TOWN OF DEWITT PLANNING AND ZONING PERMIT REQUIREMENTS FOR DECKS

R vertical and horizontal.

CITY OF COEUR D'ALENE Residential Permit Application

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

Single Family Detached home submittal Workbook

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Requirement checklist to obtain a building permit for a: RESIDENTIAL POLE BUILDING

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

Required Information for Permit Issuance

REGULATIONS FOR RESIDENTIAL OPEN WOOD DECKS

Village of Glencoe 675 Village Court, Glencoe, Illinois

Wood Decks. Zoning and Construction requirements for open non-sheltered wood decks for residential dwellings.

Last Updated March 15, 2016

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

HOW TO OBTAIN A BUILDING PERMIT

Residential Building Inspections

4. Number of drawings required: ( ) Locations of nearest streets

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS COMMERCIAL AND MULTI-FAMILY

Residential Plan Checklist

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

II. IDENTIFICATION A. OWNER OR LESSEE ADDRESS (number, street, P. O. Box, Apt., etc.)

Formulating a Korea Industrial Standard for light-frame wood construction

BUILDING PERMIT APPLICATION PACKAGE

A homeowners/applicants guide to understanding and making application for a building permit.

City of Republic Community Development Girder and Header Spans for Exterior Walls

BUILDING PERMIT BASICS

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings

Code Inspections, Inc.

CLAY TOWNSHIP BUILDING DEPARTMENT

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

Transcription:

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal Roof Size: Width: Length: Roof Type: Gable: Hip: Shed: Roof Pitch: (check one) Trusses: Rafters: Spacing of Trusses or Rafters: Rafter Size and Span: Ridge Beam: Size: Span: Roof Sheathing: Roof Covering: Roof Header Beam: Size: Span: Deck Size: Width: Length: Footer Size: Width: Length: Carrier Beam: Size: Span: Type of Floor Joist: Floor Joist: Size: Span: Decking Material: Number of Steps: Riser Height: Tread Depth:

PENNSAFE BUILDING INSPECTION SERVICES LLC RESIDENTIAL DECK AND PORCH ROOF PROJECT SUBMITTAL HANDOUT Every item below should be checked as completed (if applicable), or marked n/a (if not applicable), for your project. This form must be completed in its entirety then returned with attached drawings. Application Municipal Prior Approval Form Site Plan showing setbacks Two sets of plans (All dimensions must be indicated, be in ink and drawn to scale) **The following items are required to be included on the Building Plan Drawings:** Floorplan drawing looking down at deck/porch. Provide locations of all posts and beam locations and indicate spans. Top, front and side views of deck. Complete cross section (provided) Size, thickness and depth (below grade) of footings. Size, type and spacing of support columns. Type of wood to be used. (Specify species and grade) Size of floor joist, span and distance between joists. Size, type and span of all girder beams. Height of wood joist, girder and floor above finish grade. Type and thickness of floor sheathing. (Decking) Stair riser height and depth/width of tread. Handrail height and ballister spacing. Guardrail height and ballister spacing. Ledger fastening method, i.e. - bolt spacing. Deck flashing method Roof construction details (see cross section) **THIS COMPLETED FORM MUST BE SUBMITTED WITH PROJECT PLANS**

PENNSAFE BUILDING INSPECTION SERVICES LLC House and Addition Cross Section Submittal Roof info: Type: Check one: Gable Shed Hip Combo Slope of roof: Roof sheathing: Roof rafters: Yes No Roof rafters span: Rafter size and spacing: Trusses: Yes No Truss spacing: Ridge vent: Yes No Type of insulation: R-value: Floor System info: Type of floor joist: Floor joist span: Floor joist spacing: Floor sheathing: Type of support beam: Support beam span: Interior Finish info: Wall finish: Vapor Barrier: Ceiling Finish: Exterior walls info: Type of walls: Spacing of studs: Wall sheathing: sheathing: Type of insulation: R-value Header spans: Height of walls: Type of finish: Type of air barriers: Foundation info Type of foundation: Block ICF Concrete Other Type of footer: Footer dimensions: Thickness and Depth Frost protection depth: Below final grade Type of sillplate: Sillplate Anchoring method: Anchoring spacing: Basement floor thickness: Basement Design info: Insulation Method: Walls or Ceiling Type of insulation: R-value: Type of finish: Floor to ceiling height

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION P. O. Box 486 - DuBois, PA. 15801 Phone: 814-375-1111 Fax: 375-1117 Toll free: 855-PENNSAFE Permit No. LOCATION OF PROPOSED WORK OR IMPROVEMENT Municipality: Tax Parcel # Site Address: Lot#_ Subdivision/Land Development: Phase: Section:_ Owner: Phone# _Fax#_ Mailing Address: Email: Principal Contractor: Phone#_ Fax# Mailing Address: Architect:_ Phone# _ Fax# Mailing Address: Email:_ TYPE OF WORK OR IMPROVEMENT (Circle all that apply) New Building Addition Alteration Repair Demolition Relocation Change of Use Plumbing Electrical Mechanical Other Describe the Proposed work:_ ESTIMATED COST OF CONSTRUCTION (Reasonable fair market value) DESCRIPTION OF BUILDING USE (Check one then complete applicable info) RESIDENTIAL NON-RESIDENTIAL (Commercial) Single Family Dwelling Specific Use_ Duplex Use Group:_ Construction Type: Townhouse Change of Use (indicate former and proposed): Total Sq. ft. of finished living space Maximum Occupant Load:_ Maximum Live Load:_ (Page 1)

Sprinkler system to be installed: (Check one) Yes No BUILDING DIMENSIONS Existing Building Area: sq. ft. Number of Stories:_ Proposed Building Area: _sq. ft. Height Above Grade: ft. Total Building Area:_ sq. ft. Area of Largest Floor: sq. ft. FLOODPLAIN INFORMATION Is the site located within an identified flood plan area? (Check one) Yes No Note: All proposed development shall be in accordance with the requirements of the National Flood Insurance Program and the Pennsylvania Flood Plain Management Act. HISTORIC DISTRICT INFORMATION Is the site located within a Historical District? (Check one) Yes_ No Note: If yes, you must provide proper Historical District certification per the UCC Law. The applicant certifies that all information on this application is correct and the work will be completed in accordance with the approved construction documents and PA Act 45 Uniform Construction Code and any additional approved building code requirements adopted by the Municipality. The property owner and applicant assumes the responsibility of locating all property lines, setback lines, easements, right of ways, flood areas, etc. Issuance of a permit and approval of construction documents shall not be construed as authority to violate, cancel or set aside any provisions of the codes or ordinances of the Municipality or any other governing body. The applicant hereby certifies he/she understands all applicable codes, ordinances and regulations. Application for a permit shall be made by the owner or lessee of the building or structure, or authorized agent of either, or by the authorized registered Design Professional employed in connection with the proposed work. I certify that the Code Administrator or the Code Administrator s authorized representative shall have the authority to enter areas covered by such permit at any reasonable hour to enforce the provisions of the applicable codes to such permit. Signature of Owner or Authorized Agent Address: Print Name of Owner or Authorized Agent Date:_ Directions to Worksite: OFFICE USE ONLY below Permit Fee: $_ Plan Submittal Checklist Attached: yes no Plan Review Approval Date: (Page 2)

MUNICIPAL PRIOR APPROVAL CHECKLIST Name of Municipality Name of Applicant Parcel# Lot# This Section below to be completed by the Authorized Municipal Representative CHECKLIST ITEMS Is the project site located in a Flood Area? (Check one) yes no (Circle one)---------------------------------residential Project or Commercial Project Description of Work: Zoning or Land Use Permit Approved Not applicable Stormwater Management Approved Not applicable Street cut/ Driveway Approved Not applicable Sewage/Onlot Permit Approved Not applicable Water Permit Approved Not applicable PennDot Highway Occupancy Approved Not applicable Floodplain Permit Approved Not applicable Other Approved Not applicable I certify that all required Municipal Codes, Ordinances and Regulations have been met and approval thereby is granted to issue the requested Permit. Authorized Municipal Representative signature: Date: **NOTE THAT THIS PERMIT APPLICATION PACKAGE MUST BE COMPLETED AND THEN SUBMITTED WITH THE PROJECT CONSTRUCTION PLANS AND THE CORRESPONDING SUBMITTAL CHECKLIST** (Page 3)

PENNSAFE BUILDING INSPECTION SERVICES LLC RESIDENTIAL STICK BUILT HOUSE SUBMITTAL HANDOUT Every item below must be checked as completed (if applicable), or marked n/a (if not applicable), for your project. This form must be completed in its entirety then returned with attached drawings. Permit Application Municipal Prior Approval Form Two full sets of plans. All dimensions must be indicated and drawn to scale. **The following items are required to be included on the building plans** Site plan indicating all setbacks Exterior elevation of all sides Floorplan with overview of each floor level, with all rooms labeled and all sizes indicated. Complete cross-section view of structure (provided with form) Size and depth of footings. Include all pads and columns. Foundation details: indicate type such as masonry cinder block, ICF or superior wall, Type of sillplates to be used and fastening method. Size, location and type of support columns. Structural support beams show sizes and how they are supported. Species and grade of all framing lumber. Floorjoists type, size and spacing. Indicate type, size and thickness of floor sheathing. Interior and exterior wall stud sizes, grade and spacing. Provide header schedule showing spans and sizes. Interior wall finish. Exterior wall covering. Provide window schedule: including manufacturer, locations with corresponding numbers. Roof framing: denote trusses or rafters. Indicate spans, sizes and spacing. Roof sheathing: type and thickness Roof covering and ventilation method. Indicate Attic access size and locations. Indicate basement means of egress method. Provide porch and deck drawings. Indicate concrete floor material and thickness. If garage is attached to house, indicate method of fire separation include doors. Submit heat-loss/gain calculations. Indicate type of heating system and equipment location. All electrical work to conform to UCC adopted version of National Electric Code (NEC)

Provide stairway details: Minimum width is 3 ; Maximum stair rise is 8-1/4 ; Minimum tread depth is 9 with ¾ to 1-1/4 nosing; Minimum headroom is 6 8. Provide guardrail detail: Required for porches, balconies, open sides of stairs, or raised floor surfaces greater than 30 above floor or grade below; Minimum 36 above finished floor at horizontal locations; Minimum 34 above the leading edge of nosing measured vertically at stairs; Opening limitations = < 4 and < 6 at triangle formed by the rise and run of stairs and bottom of guardrail. Smoke detectors: show locations (one on each floor, one in each sleeping room and in the vicinity of each sleeping room); Interconnected and hardwired with battery back-up provided. Carbon monoxide detectors: show type and locations. Submit Energy Code Compliance Path. Provide approval certificate at electric service panel. Chimneys and fireplaces: indicate type, location and footing details. Basement: (Check one) Finished Unfinished If Finished must provide locations of finished areas total square footage to be finished is sq. ft. If Unfinished notate on plan. **Always remember you are required to contact PA One Call at 800-242-1776 before you dig** **THIS COMPLETED FORM IS REQUIRED TO BE SUBMITTED WITH THE PROJECT PLANS** BUILDING INSPECTIONS FOR SAFER COMMUNITIES