TECHNICAL NOTE HEADER DESIGN. On Cold-Formed Steel Construction INTRODUCTION BOX HEADERS $5.00

Similar documents
TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Structural vs Nonstructural Members. Roger LaBoube, Ph.D., P.E. Wei-Wen Yu Center for Cold-Formed Steel Structures

COFS Mission. AISI Standards Hierarchy. North American Standards for Cold-Formed Steel Framing. Member versus System Design. Specification 10/21/2016

Standard for Cold-Formed Steel Framing - Header Design

TECHNICAL NOTE On Cold-Formed Steel Construction

Product Designation As specified in the AISI standard for cold formed steel framing General provisions A5.2.

INTRODUCTION DISCLAIMER

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Arc Spot Welds in Sheetto-Sheet RESEARCH REPORT RP01-6 JUNE 2001 REVISION 2006

Web Crippling and Combined Bending and Web Crippling of Cold-formed Steel Box-beam Headers

SUGGESTED COST-EFFECTIVE COLD-FORMED STEEL FIRE AND ACOUSTIC-RATED WALL AND FLOOR/ CEILING ASSEMBLIES FOR MULTI-UNIT STRUCTURES

MECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS. Paul E. Lackey, EIT Nabil A. Rahman, Ph.D.

Cold-Formed Steel Design Support

TECHNICAL NOTE On Cold-Formed Steel Construction

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS

Top Arc Seam Weld Shear Strength and Stiffness for Sheet-to-sheet Connections

VERTICAL AND HORIZONTAL LATERAL LOAD SYSTEMS

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

TECHNICAL NOTE. On Cold-Formed Steel Construction DESIGN CONSIDERATIONS FOR FLEXURAL AND LATERAL-TORSIONAL BRACING

Web Crippling of Cold Formed Steel C-and Z- Sections

HSS section calculations are based on the AISC Steel Construction Manual, 13 th edition (ASD only).

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

REPORT HOLDER: STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) 35 EAST WACKER DRIVE, SUITE 850 CHICAGO, ILLINOIS EVALUATION SUBJECT:

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

AIA St. Louis January 4 th, 2017 Phillip Shinn, PE Jacobs Engineering Washington University in St. Louis, Sam Fox School of Design and Visual Arts

Copyright. magazine. CFS Load Bearing Construction

Lightweight Steel Framing. Composite DeltaStud Load Tables

research report Cold-Formed Steel Walls with Fiberboard Sheathing Shear Wall Testing RESEARCH REPORT RP REVISION 2006

Monotonic Tests of Cold-Formed Steel Shear Walls with Openings

An Update on AISI Standards for Cold-Formed Steel Framing

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

Effective Width Method Based Design for Distortional Buckling

Originally Issued: 03/10/2017 Revised: 03/30/2019 Valid Through: 03/31/ Design

ESR-2961 Reissued September 1, 2011 This report is subject to renewal in two years.

research report Estimating the Response of Cold-Formed Steel Frame Shear Walls RESEARCH REPORT RP REVISION 2006

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Light Steel Framing Members. Table of Contents

Spacing of Connections in Compression Flanges of Built-up Cold-formed Steel Beams

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

COMBINED ADHESIVE-STEEL PIN APPLICATIONS FOR CFS FRAME SHEAR WALLS

research report Performance of Cold-Formed Steel-Framed Shear Walls: Alternative Configurations RESEARCH REPORT RP REVISION 2006

ANALYSIS AND DESIGN OF MOMENT RESISTING MIDWALL BY THE STEEL NETWORK, INC.

Sabah Shawkat Cabinet of Structural Engineering 2017

PR-L274 Nordic Structures Revised April 16, 2017

Structural Redesign Gravity System

Light Steel Framing Members. Table of Contents

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Standard for Cold-Formed Steel Framing - Truss Design, 2004 Edition

Lateral Strength of Wind Load Bearing Wall Studto-track

AASHTOWare BrDR 6.8 Steel Tutorial STL6 Two Span Plate Girder Example

The New SDI Diaphragm Design Manual

fifteen steel construction: materials & beams ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2016 lecture

THE SITUATION WITH STEEL DECKS

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017

William W. Wilkins Professional Building

Finite Element Modeling of New Composite Floors Having Cold-Formed Steel and Concrete Slab

AISI Standard for Cold-Formed Steel Framing - Truss Design

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

research report Strength of Cold-Formed Steel Jamb Stud-To-Track Connections RESEARCH REPORT RP08-1 American Iron and Steel Institute

AISI Standards for Cold-formed Steel Framing

Proposed Modifications to the LRFD Design of U-Beam Bearings

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

Bjorhovde, R. Stub Girder Floor Systems Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press LLC, 1999

Design of Short Span Steel Bridges

Contents. 1.1 Introduction 1

Flexure Design Sequence

AASHTOWare BrR 6.8 Steel Tutorial Steel Plate Girder Using LRFR Engine

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised January 24, 2017

APPENDIX B ABC STRUCTURES DESIGN GUIDE

Subscribers of Fire Rated Floor, Floor-Ceiling and Beam Designs (UL Categories CERZ,

The 2013 AISI Cold-Formed Steel Design Manual

ADAPT Floor Pro 2009/2010 Tutorial Export Design Strip to ADAPT PT or ADAPT RC

AISI S E1 AISI STANDARD. Errata to North American Specification. for the Design of Cold-Formed. Steel Structural Members.

City of Republic Community Development Girder and Header Spans for Exterior Walls

LVL Product Guide 2.0E LVL 1.5E LVL

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT:

Analysis and Design of One-way Slab System (Part-I)

Figure: Grid or Waffle slab

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

Slab Bridge Designer 2.1 Help: Example Analysis

AISI STANDARD. Endorsed by:

Reinforced Concrete Tilt-Up Wall Panel Analysis and Design (ACI 551)

AASHTOWare BrR/BrD 6.8 Reinforced Concrete Structure Tutorial RC5 Schedule Based Tee Example

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

Joint Evaluation Report

111 MORGAN ST. Ryan Friis

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

BUILDING RETROFITS: BREATHING NEW LIFE INTO EXISTING BUILDING STRUCTURES

research report Experimental Evaluation of the Strength and Behaviour of 16- and 18-Gauge Cold Formed Steel Top Track Systems RESEARCH REPORT RP05-4

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

CH. 9 WOOD CONSTRUCTION

Precast Concrete Bearing Wall Panel Design (Alternative Analysis Method) (Using ACI )

80 Fy (ksi)= 50 2 nd Floor = 61. Length (ft) Plan View. Penthouse

W. Mark McGinley March 3, 2016 ISEA MEETINGS 1

Transcription:

TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 HEADER DESIGN Summary: The Standard for Cold-Formed Steel Framing - Header Design (AISI S212-07) is aimed at giving design professionals the tools they need to design headers over door and window openings in buildings. AISI S212-07 (Header) reflects the appropriate design procedures for back-to-back headers, box headers, and L-headers subject to gravity loads or wind uplift loads. This Technical Note provides additional recommendations and design examples intended to augment AISI S212-07 (Header). INTRODUCTION The Standard for Cold-Formed Steel Framing - Header Design (AISI S212-07) is aimed at giving design professionals the tools they need to design headers over door and window openings in buildings. AISI S212-07 (Header) reflects the appropriate design procedures for back-to-back headers, box headers, and L-headers subject to gravity loads or wind uplift loads. The design recommendations have been heavily influenced by research at the University of Missouri-Rolla and the National Association of Home Builders. A header is a flexural member spanning a wall opening. Therefore, the AISI S212-07 (Header) Standard establishes both design and installation requirements for: moment capacity, shear capacity, web crippling and combinations of bending and shear and bending and web crippling. AISI S212-07 (Header) does not provide design guidance for wind loads applied perpendicular to the wall, i.e. out-of-plane loads. For design guidance pertaining to out-of-plane loads and for additional example problems for gravity load applications the reader is referred to Cold-Formed Steel Framing Design Guide (AISI D110-07). Three header configurations are addressed by AISI S212-07 (Header): back-to-back, box and L-headers (Figures 1A, 1B, 1C and 1D). The stipulated design provisions are founded on the design requirements of the North American Specification for the Design of Cold-Formed Steel Structural Members (AISI S100-07) with modifications applicable to the respective header configurations. A key aspect of the design provisions is the recognition that these headers are assemblies and thus to achieve optimum strength and economy the headers should be designed as assemblies. BOX HEADERS AISI S212 includes provisions for all potential strength limit states pertaining to the box-header, i.e. bending, shear, web crippling and combinations of these limit states. Bending. The design provisions for bending alone stipulate that the moment capacity of the built-up section must be determined based on the moment capacity of the two C- sections alone. The interconnection of the track with the C- sections using a fastener spacing of 24 inches on center is inadequate to develop composite action. Thus, there is no modification to the provisions of Section C3.1.1 of AISI S100-07 (Specification). Shear. The design provisions for shear alone stipulate that the shear capacity of the built-up section must be determined based on the shear capacity of the two C-sections alone. The interconnection of the track with the C-sections does not develop an increase in the web shear capacity. Thus, there is no modification to the provisions of Section C3.2 of AISI S100-07 (Specification). Combined Bending and Shear. The design provisions of Section C3.3 of AISI S100-07 (Specification) are applicable to the box header. Web Crippling. Research has shown that the interior-oneflange loading capacity of the C-sections that form the box header is favorably influenced by the track section. Therefore, to evaluate the nominal strength for the interior-one-flange web crippling strength of a box-beam header, P n, which is for a single, unreinforced web, represents the increase in web crippling strength for the box-header assembly: P ' n t = 2. 3 t t c Pn Pn Where P n is determined by using Eq. C4.3-1 from the AISI S100 for the interior-one-flange loading condition, t c = thickness of C-section, and t t = thickness of top track taken Cold-Formed Steel Engineers Institute 1 TECH NOTE W200-09 February 2009

as 0.0346 in. The top track thickness is stipulated as 0.0346 inches because this was the track thickness used in the research study (Stephens and LaBoube, 2003). For design, the allowable web crippling strength is P a = P n / Ω where the safety factor Ω is1.80. AISI S212 also permits LRFD. At end supports for the end-one-flange loading, AISI S100 must be used. Combined Bending and Web Crippling. To provide a more accurate interaction of bending and web crippling, the following interaction equation is stipulated by AISI S212: P M + P n M n 1.5 / Ω Where nd re the required strengths, i.e. the unfactored or nominal load and moment. P n is computed by Section B2.3 of S212 and M n Fy based on Section C3.1.1 of the AISI S100. Both P n and M n are taken as the sum of the two C- sections that form the box header. The safety factor is 1.85. A similar interaction equation is provided by AISI S212 for LRFD. BACK-TO-BACK HEADERS The AISI S212-07 (Header) includes provisions for all potential limit states pertaining to the I-header, i.e. bending, shear, web crippling and combinations of these limit states. Based on a research study by Stephens and LaBoube (2003), the design strength of an I-beam header must be computed using the provisions given in the AISI S100-07 (Specification). Noteworthy is that the calculations for I-beam web crippling strength for the header may be taken as if the header is a built-up section even though the fastener spacing does not meet the specification definition of a built-up section. Web crippling strength alone is determined using the built-up section coefficients. PRACTICAL CONSIDERATIONS The selection of the header geometry is generally at the discretion of the design engineer. When considering the selection of the header geometry the design engineer may want to consider the following: For gravity loads lateral stability is an important design issue, especially for longer spans. A top of wall header will generally be more laterally stable than a top of opening header. The header is more stable because the joists or truss members being supported by the header will provide lateral support. If a box or back-to-back header is used as a top of wall header the header may not be capable of providing adequate out-ofplane stability for the wall. Attention must be given to the top of wall detail. For lateral stability for long spans, a box header is likely to be more stable than a back-to-back header. For wind loads a top of opening header may be required to provide adequate stability for the window and to transfer the wind loads. The back-to-back header is easier to inspect for the installation of the insulation. If joists or trusses frame into the header, the back-to-back header may be more likely to share the load between the two C-sections. However, a back-to-back header may be more difficult to attach joists or trusses framing into the side. The single and double L-header has little uplift capacity. Use of the L-header enables all king and jack studs to be the same length. Additional practical considerations are provided by SSMA on their website www.ssma.com, click on Tech Library. L-HEADERS The AISI S212-07 (Header) includes provisions for all potential limit states pertaining to the L-header, i.e. bending, shear, web crippling and combinations of these limit states. The single, double, and inverted L-headers are addressed by AISI S212. The design methodology is similar for single and double L-headers, except specific limitations are defined based on what has been tested. FIGURE 1A: SINGLE L-HEADER TECH NOTE W200-09 February 2009 2 Cold-Formed Steel Engineers Institute

FIGURE 1B: BACK-TO-BACK HEADER FIGURE 1C: BOX HEADER Example Problems FIGURE 1D: DOUBLE L-HEADER FIGURE 2: LOADBEARING OPENING ELEVATION Cold-Formed Steel Engineers Institute 3 TECH NOTE W200-09 February 2009

Design a box header for the 4 ft window opening (Figure 2). The header is assumed to be a simple span beam supporting the two cripple studs (Figure 3). Using Allowable Strength Design size the header C-sections as follows: 1. Use the AISI Specification, S100 2. Use the Header Standard, S212 Applied forces (total on both C-sections): Applied P = 2.79 kips Applied M = 44.6 in.-kips Using the AISI Specification BOX HEADER DESIGN Try 800S162-68 ( = 50 ksi) for the C-sections., per Section C3.1.1 of the Specification = 99.64 in.-kips (without punchout) Applied M = 44.6 in.-kips, flexure alone is okay Using AISI Specification Section C3.4 for the interior-one-flange load condition = 2.151 kips/web x 2 webs = 4.30 kips > 2.79 kips Bending and Web Crippling: Using AISI Specification Section C3.5with P = 2.79 kips, M = 44.6 in-kips, P n = 1.65 x 4.30 kips, M n = 1.67x99.64 in-kips Interaction Eq. C3.5.1-1 = 0.63 < 0.78 = 4.220 kips/web x 2 webs = 8.44 kips < 2.79 kips Conclusion: 2-800S162-68 are okay for the header! Try 800S162-54 (Fy = 50 ksi) for the C-sections., per Section C3.1.1 of the Specification = 73.68 in.-kips (without punchout) Applied M = 44.6 in.-kips, flexure alone is okay Using AISI Specification Section C3.4 = 1.40 kips/web x 2 webs = 2.80 kips > 2.79 kips Bending and Web Crippling: Using AISI Specification Section C3.5 Interaction Eq. C3.5.1-1 = 1.80 > 1.5, No Good! FIGURE 3: HEADER FREE BODY DIAGRAM Using the Header Standard Try 800S162-54 ( = 50 ksi) for the C-sections. Is the same as when using the AISI Specification: = 73.68 in.-kips (without punchout) Applied M = 44.6 in.-kips, flexure alone is okay! Using Header Standard Section B2.3 α = 2.3 (t t /t c ) > 1.0 = 2.3 (0.0346 /0.0566 ) = 1.41 P n = 2.80 kips x 1.65 = 4.62 kips (two webs, where 1.65 is the safety factor per the AISI Specification Section C3.4) = α P n /Ω = 1.41 (4.62 kips /1.80) = 3.62 kips (for 2 webs) 3.37 kips > 2.79 kips, Bending and Using Header Standard Section B2.5 and Interaction Eq. B2.5-1 P/P n + M/M n < 1.5/Ω, where Ω= 1.85 2.79/(1.41x4.62) + 44.6/(73.68 x 1.67)= 0.791 < 0.81 = 2.091 kips/web x 2 webs = 4.18 kips < 2.79 kips Conclusion: 2-800S162-54are okay for the header design! Design Summary For the above strength based design the following C- sections and track sections may be used. Neither AISI S212 nor AISI S100 provide specific design requirements for serviceability. However, the header must be designed to perform its intended function without damaging attached finish materials. Therefore, an acceptable service limit state should be considered. TECH NOTE W200-09 February 2009 4 Cold-Formed Steel Engineers Institute

C-Sections: Using the AISI Specification: 800S162-68 or 800S162-54 with bearing stiffeners Using the Header Design Standard: 800S162-54 Track Sections: Although common practice is to use matching wall stud and track thicknesses, based on the design for web crippling the track section thickness may be 0.0346 inches. However, the track must be designed for the applied lateral loads in which case 0.0346 inches is the minimum thickness that may be used. Note: The header assembly details must adhere to details illustrated by Figure 1C taken from Section A1.1.1 of the AISI S212. BACK-TO-BACK HEADER DESIGN Design a back-to-back header for the 4 ft window opening (Figure 2). The header is assumed to be a simple span beam supporting the two cripple studs (Figure 3). Using Allowable Strength Design size the header C-sections as follows: 3. Use the AISI Specification, S100 4. Use the Header Standard, S212 Applied forces (total on both C-sections): Applied P = 2.79 kips Applied M = 44.6 in.-kips Using the AISI Specification Try 800S162-68 (Fy = 50 ksi) for the C-sections., per Section C3.1.1 of the Specification = 99.64 in.-kips (without punchout) Applied M = 44.6 in.-kips, flexure alone is okay! Use AISI Specification Section C3.4 as single unreinforced webs. Although the Specification provides web crippling design for a built-up sections, the back-to-back header does not have sufficient web connectors to qualify as a built-up section in the Specification. = 1.903 kips/web x 2 webs = 3.81 kips > 2.79 kips Bending and Web Crippling: Using AISI Specification Section C3..5, Equation C3.5.1-2 Interaction Eq. C3.5.1-2 = 1.340 < 1.5 = 4.220 kips/web x 2 webs = 8.44 kips < 2.79 kips Conclusion: 2-800S162-68 are okay for the header! Using the Header Standard Try 800S162-54 ( = 50 ksi) for the C-sections. Is the same as when using the AISI Specification: = 73.68 in.-kips (without punchout) Applied M = 44.6 in.-kips, flexure alone is okay! = 4.67 kips for both webs (built-up section, AISI Specification Section C3.4) 4.67 kips > 2.79 kips, Using the Specification Section C3.5.1 and Interaction Eq. C3.5-2 0.88P/P n + M/M nxo < 1.46/Ω where Ω = 1.70 0.88x2.79/(4.67x1.65) + 44.6/(73.68 x 1.67)= 0.681 < 0.81 = 2.091 kips/web x 2 webs = 4.18 kips < 2.79 kips Conclusion: 2-800S162-54 are okay for the header! Design Summary C-Sections: Using the AISI Specification: 800S162-68 Using the Header Design Standard: 800S162-54 Track Sections: Although common practice is to use matching wall stud and track thicknesses, based on the research that serves as the basis for the web crippling design methodology the track section thickness may be 0.0346 inches. Note: The header assembly details must adhere to details illustrated by Figure 2 taken from Section A1.1.1 of the AISI S212. Cold-Formed Steel Engineers Institute 5 TECH NOTE W200-09 February 2009

L-HEADER Design a double L-header for a door opening of 3 ft. The stud spacing is 24 in. on center. The top flange bearing length, N, is 1.625 in. The L-header is assumed to be a simple span assembly. For a 3 ft span with studs 24 inches on center, the worst loading condition will be the cripple stud located at midspan of the L-header. Steel properties are taken as follows for the L-header: sheet thickness < 43 mil, = 33 ksi; sheet thickness > 43 mil, = 50 ksi. Based on the nominal gravity load and wind load, the following summarizes the cripple stud forces that will be applied to the L-header: Upper Floor Load: 1.2 k (gravity) and 0.69 k (uplift) Lower Floor Load: 3.12 k (gravity) and 0.40 k (uplift) The L-header is analyzed as a simple span beam with a concentrated load applied at midspan of the 3 ft. header span. Nominal moment, M = PL/4 is summarized as follows, where L = 3 ft. and the loads are defined above for the upper and lower floors M M Floor Gravity Uplift (in.-kips) (in.-kips) Upper 10.80 6.21 Lower 28.08 3.60 Using Section B3.1 of the header standard, = M ng /Ω where M n = S xc and S xc = the elastic section modulus of the effective section calculated at f = in the extreme compression fibers. Lower Floor Double L-Header: Try 600L150-54 Gravity Allowable Strength = 31.90 in.-kips > 28.08 in.-kips Uplift Allowable Strength = 0.25 x 31.90 in.-kips = 7.98 in.-kips > 6.21 in.-kips Upper Floor Double L-Header: Try 600L150-43 Gravity Allowable Strength = 23.78 in.-kips > 10.80 in.-kips Uplift Allowable Strength = 0.25 x 23.78 in.-kips = 5.95 in.-kips < 6.21 in.-kips No Good! Use 2-600L150-54 for both the upper and lower floor headers. The header standard does not provide a design methodology for a single L-header subjected to a wind uplift load. Therefore only the double L-header can be used in this application. References 1. Standard for Cold-Formed Steel Framing - Header Design (AISI S212-07), American Iron and Steel Institute, Washington, DC, 2007. 2. North American Specification for the Design of Cold-Formed Steel Structural Members (AISI S100-07), American Iron and Steel Institute, Washington, DC, 2007. 3. Cold-Formed Steel Framing Design Guide (AISI D110-07), American Iron and Steel Institute, Washington, DC, 2007. 4. Stephens, S.F., and LaBoube, R.A, Web Crippling and Combined Bending and Web Crippling of Cold-Formed Steel Beam and Headers, Thin-Walled Structures, 41, Elsevier Ltd, 2003. Primary Author of this Technical Note: Roger LaBoube, Ph.D., P.E., Wei-Wen Yu Center for Cold- Formed Steel Structures CFSEI Technical Review Committee: Rob Madsen, P.E., Devco Engineering, Inc., chairman. This Technical Note on Cold-Formed Steel Construction is published by the Cold-Formed Steel Engineers Institute ( CFSEI ). The information provided in this publication shall not constitute any representation or warranty, express or implied, on the part of CFSEI or any individual that the information is suitable for any general or specific purpose, and should not be used without consulting with a qualified engineer, architect, or building designer. ANY INDIVIDUAL OR ENTITY MAKING USE OF THE INFORMATION PROVIDED IN THIS PUBLICATION ASSUMES ALL RISKS AND LIABILITIES ARISING OR RESULTING FROM SUCH USE. CFSEI believes that the information contained within this publication is in conformance with prevailing engineering standards of practice. However, none of the information provided in this publication is intended to represent any official position of the CFSEI or to exclude the use and implementation of any other design or construction technique. TECH NOTE W200-09 February 2009 6 Cold-Formed Steel Engineers Institute